CS Paper Radar

LeCor: Learning to Be Corrected by Meta-Learned Test-Time Training for Interactive 3D Lung-Tumour Segmentation

Yi Luo, Yike Guo, Wenxuan Li, Zongwei Zhou, Rui Zhang, Kai Ding

cs.CV cs.LG ·submitted 2026-09-08 21:49 UTC · v1

Abstract

Delineating lung tumours on computed tomography (CT) takes a considerable share of the time spent on radiotherapy planning, and a contour proposed by a model can be refined interactively by the clinician. Promptable foundation models such as SAM 3 support this workflow by writing each correction into a session memory that conditions the remaining slices, while the model weights stay fixed. On 690 test cases from five public CT cohorts, fine-tuning SAM 3 on lung tumours raises the Dice obtained from a single point prompt from 0.298 to 0.757, and seven rounds of corrections raise it further to 0.765, but under memory conditioning alone the accuracy on slices the annotator has not touched stops improving after six rounds. We therefore treat each correction as a training signal and propose LeCor, which performs test-time training on a small set of case adapters that are reset for every case and meta-learned such that a single gradient step driven by a click improves the slices that were not clicked. On the 133 test cases that span at least eight slices, LeCor raises the Dice reached after seven correction rounds from 0.787 with the fine-tuned model to 0.827, reduces the number of cases that never reach a Dice of 0.80 from 47 to 27, and reaches in three correction rounds the accuracy that the fine-tuned model attains in seven.

Comment
18 pages, 4 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Prompt-Guided Interactive Segmentation of Interstitial Lung Disease in Thoracic CT

cs.CV ·2026-08-28 ·Vasilis Dedousis, Lubnaa Abdur Rahman, Lorenzo Brigatο, Ethan Dack, Andreas Christe +6 more
code/data similarity 0.68
Abstract

Accurate segmentation of interstitial lung disease (ILD) patterns is essential for quantitative disease assessment and longitudinal monitoring. However, existing approaches remain limited by relying on dense annotations and producing static predictions that cannot be refined, motivating interactive approaches. While promptable models show promise in interactive segmentation, their adaptation to ILDs remains largely unexplored. To address this gap, we investigate prompt-guided foundation models for ILD refinement and present, to the best of our knowledge, the first adaptation of MedSAM2 for interactive 3D ILD segmentation on thoracic CT. We investigate three fine-tuning strategies and multiple clinically motivated prompts: bounding-boxes (BBox), point, lasso, and scribble. On a dataset spanning seven ILD patterns and healthy lung tissue, full model fine-tuning performed best, improving the average Dice score by 4.7 percentage points over MedSAM2.While BBox prompts achieve the strongest performance, non-native MedSAM2 interactions such as lasso and scribble prompts also prove effective. Finally, we present and evaluate a proof-of-concept end-to-end workflow in which MedSAM2 is initialized from an automatic segmentation prior and subsequently refined using radiologist prompts. Model weights and plug-ins made available at: https://github.com/AIHNlab/ILD-SemiSegTool.

0.21

From Slices to Volumes: Comparing 2D, 2.5D, and 3D Residual Networks for Pulmonary Nodule Malignancy-Risk Classification

cs.LG cs.CV ·2026-10-25 ·Bahodir Nazarov, Zineb Gharib, Fatima Zazoul
code/data similarity 0.67
Abstract

Purpose: To compare 2D, 2.5D, and 3D residual networks for pulmonary nodule malignancy-risk classification and evaluate momentum-contrast pretraining, mild augmentation, and exclusion of indeterminate ratings. Methods: A retrospectively prepared LIDC-IDRI cohort contained 2,654 nodules labeled benign, indeterminate, or malignant using median radiologist ratings. Patient-disjoint splits comprised 1,876 training, 382 validation, and 396 test nodules. Representations included one axial slice, five neighboring slices, and a local CT volume. Each track evaluated a randomly initialized baseline, momentum-contrast pretraining followed by fine-tuning, and supervised training with mild augmentation. Checkpoints were selected by validation Macro-F1. The 2D experiments used three seeds; 2.5D and 3D results were single-run estimates. A separate binary experiment excluded indeterminate nodules. Results: Augmented models achieved test Macro-F1 values of $0.6134\pm0.0075$ for 2D, $0.6537$ for 2.5D, and $0.5403$ for 3D; the 2D uncertainty denotes population standard deviation across seeds. Corresponding accuracies were $0.6128$, $0.6869$, and $0.5455$. Augmentation improved Macro-F1 within every track, whereas the tested pretraining recipes reduced it. Binary Macro-F1 values were $0.8227$, $0.8664$, and $0.7554$, respectively. Conclusion: Augmented 2.5D achieved the highest observed performance. Differences in preprocessing, optimization, capacity, and replication limit attribution to dimensionality. Labels reflect radiologist-assessed malignancy risk rather than pathology-confirmed cancer. Code and experimental results are available at https://github.com/CT-DeepLearning-Team/CT-2D-2.5D-3D-DeepLearning.

0.18

From Vision to Context: A Review of Prompt-Driven Target Volume Segmentation in Radiotherapy

eess.IV ·2026-11-04 ·Bakpen Kombat, Guus Grimbergen, Maarten L. Terpstra, Gert J. Meijer, Lois +1 more
survey similarity 0.65
Abstract · Submitted to Computerized Medical Imaging and Graphics

Accurate target volume (TV) segmentation is essential for radiotherapy (RT) planning but remains time-consuming. Moreover, the final contour depends on the expertise of the radiation oncologist. Although deep learning has improved medical image segmentation, image-only models cannot encode the clinical reasoning that governs TV delineation, particularly for the clinical target volume (CTV), where boundaries are defined by clinical knowledge rather than imaging features alone. Prompt-driven segmentation has recently emerged as a strategy to address this limitation. This work aims to review these approaches for RT TV segmentation with four objectives: (1) compare the different prompting techniques used; (2) compare their performance against image-only baselines; (3) assess how they are evaluated against standard metrics, including the Dice similarity coefficient (DSC), 95th Hausdorff distance, sensitivity, precision, and clinical assessment; and (4) identify the gaps needed for clinical translation. We systematically searched PubMed, Embase, and arXiv for studies incorporating geometric, clinical text, or interactive prompts into deep learning models for RT TV delineation. Thirteen studies met the inclusion criteria, spanning head and neck, breast, prostate, lung, cervix, and rectal cancers. Seven studies used clinical text prompting, four used geometric prompting, and two used interactive prompting; three combined modalities. Reported DSC ranged from 0.67 to 0.93, compared to 0.65 to 0.91 for image-only baselines. None reported sensitivity or precision. Clinical text prompting appears well suited to CTV delineation. Evidence remains limited, and standardized prompt engineering and clinical validation are needed before these approaches can be translated into routine RT practice.

0.23

Personalising Deformable Image Registration with Clinical Context and Deformation History for Adaptive Radiotherapy

eess.IV cs.AI ·2026-10-13 ·Caiwen Jiang, Songlin Zhao, Yuzhen Ding, Jia Mi, Samir H. Patel +21 more
benchmark similarity 0.65
Abstract · 27 pages, 7 figures and 6 tables. The submission includes Supplementary Information

Adaptive radiotherapy must account for anatomical changes during treatment, but doing so depends on reliably mapping targets, organs at risk and dose across serial images. Existing registration methods treat each image pair independently, without using radiotherapy-specific context or the patient's preceding anatomical trajectory. We developed Clinical-context-Aware and Patient-adaptive Deformable Image Registration (CAP-DIR), integrating source contours, dose, clinical text and prior-registration features. We evaluated 16,361 CT examinations from 3,473 patients across four institutional cohorts and five public benchmarks. CAP-DIR increased internal-test organ-at-risk-region normalized cross-correlation from 84.76% to 96.92% relative to the strongest learning-based comparator, with low deformation folding, and remained superior across seven external cohorts. In a blinded review of 20 longitudinal cases, clinically acceptable contours increased from 45.0% to 82.5% for clinical target volumes and from 22.5% to 62.5% for organs at risk, while estimated editing time decreased. In a controlled benchmark, CAP-DIR reduced global dose-mapping error by 34.5% relative to the strongest comparator. These findings show that clinically informed, longitudinal registration can improve contour usability and dose mapping for adaptive radiotherapy.

0.37

Anatomy-Aware Prediction of Bronchoscopic Accessibility from 3D CT

cs.CV ·2026-09-29 ·Linkai Peng, Cuiling Sun, Bin Wang, Jamie Rowell, Catherine Gao +8 more
top venuebenchmark similarity 0.64
Abstract · Accepted in MICCAI 2026

Pre-operative planning for bronchoscopy is critical for the diagnosis of lung lesions. Current accessibility assessment relies on subjective manual inspection of CT scans, which is time-consuming and prone to inter-observer variability. In this paper, we formalize bronchoscopy accessibility prediction as a novel supervised learning task and present the first end-to-end framework to address it. We propose an Anatomy-Aware Mixture-of-Experts (MoE) model that integrates specialized modules: a CT Expert for local morphological features, a Lobe Expert for anatomical priors, and a Path Geometry Expert that encodes the sequential constraints of the bronchial tree. To support this task, we curated the first clinical dataset of 438 cases with pre-operative CT scans and documented procedural outcomes. Experimental results demonstrate that our method achieves an AUROC of 0.8052, significantly outperforming both state-of-the-art baselines and experienced human experts. This work establishes a new benchmark for computer-aided interventional planning in pulmonary medicine. Our data and code will be publicly available at https://nubagcilab.github.io/BronchoAccess/.

0.37

BagShift: Measuring How Patch Selection Changes the Evidence Seen by Whole-Slide MIL

cs.CV ·2026-08-16 ·Ruicheng Yuan, Zhenxuan Zhang, Liwei Hu, Anbang Wang, Haijie Xu +2 more
similarity 0.64
Abstract · 18 pages include Supplementary Material. 8 figures

Whole-slide multiple-instance learning (MIL) observes only the patches admitted by its selector. Deployment can alter this selector through compute limits, tissue masking, or regional workflows, even when the patch count is unchanged. We introduce BagShift, a paired protocol that changes the selector for the same case while holding its features and predictor fixed, thereby isolating selector response from case mix. With equal 128-patch budgets, sampling across the tissue or concentrating around one coordinate exposes markedly different evidence: on PANDA, the two views reduce quadratic weighted kappa by 1.57 and 17.96 points, respectively (QWK reported on the $\times100$ scale). On CAMELYON16, lesion annotations withheld from model development show that localized views retain tumor in only 10.0\% of micrometastatic observations, and matched exposure does not consistently recover the loss. The same fixed-count stressor produces a much smaller response on external lung subtyping, although differences in relative coverage make cross-task severity descriptive. When repeated localized observations are available, unioning their patches before one nonlinear MIL pass improves PANDA QWK by 7.87 points over averaging regional predictions. Patch count specifies computation, not observed evidence; deployment evaluations should report both what a selector preserves and how repeated observations are aggregated.

0.10

BRACHIO: Broad Representations Across Centres for Head-and-neck Imaging Oncology (HECKTOR 2026)

cs.CV ·2026-10-29 ·Roxanne De Maeyer, Ine Dirks, Yannick Brackenier, Simon DeKeyser, Jef Vandemeulebroucke +1 more
published similarity 0.64
Abstract · HECKTOR Challenge 2026, MICCAI, head and neck cancer, PET imaging

The HECKTOR 2026 challenge benchmarks machine learning for head and neck cancer, where teams delineate primary and nodal tumour volumes, perform TN staging, and predict recurrence-free survival (RFS). This report describes the submissions for the HECKTOR challenge of team nucli. As the three tasks span both dense and global information from multicentric PET/CT scans, we utilise self-supervised pre-trained encoders, training a 2D DINOv2 encoder (PET-DINOv2-MIPs) on HECKTOR 2026's PET scans. Our final test submission ensembles a DynUNet trained from scratch with a SwinUNETR whose Swin trunk was initialised from a SimMIM-pre-trained checkpoint for segmentation, reaching a mean Dice of 0.5409. For TN staging, GTVp/GTVn geometric features from the segmentation masks are fit to stage probabilities by logistic regression (LR) and fused with PET-DINOv2-MIPs deep features (PCA + LR) via a second-level LR, reaching balanced accuracies of 0.3962 (T-stage) and 0.6432 (N-stage). For the RFS prognosis task, we fine-tune the last two blocks of the PET-DINOv2-MIPs ViT-S encoder jointly with an MLP head under a CoxPH loss, concatenating clinical covariates with the imaging features, reaching a test Harrell's C-index of 0.6577 and a weighted challenge score of 0.5802. The prognosis result is comparable to the best entry of the previous edition and consistent with our internal cross-validation, while our segmentation result is well below it and limits the staging results that depend on it.

0.32

Anatomy-Change-Aware Bidirectional Selective State-Space Memory for Clinically Deployed Thoracic Radiotherapy Auto-Contouring

eess.IV cs.CV ·2026-09-11 ·Galib Ahmed, Istiak Ahmed, Aritra Islam Saswato, Asib Mostakim Fony, Kazi Shahriar Sanjid +13 more
similarity 0.64
Abstract

We developed DAMM-Net++, a 2.5D architecture for thoracic OAR and target volume segmentation that addresses three persistent challenges in radiotherapy auto-contouring: inter-slice surface incoherence, systematic failure on small low-contrast targets, and the absence of per-case reliability signals. The central component is an anatomy-change-aware bidirectional selective state-space memory that models through-plane anatomical change and selectively propagates context along the axial slice sequence. A boundary-aware decoder sharpens near-surface predictions, and an uncertainty head provides calibrated per-voxel confidence for clinical triage. We evaluated 2,146 patients across four centers, an independent external cohort of 112 patients, and a multicenter reader study involving 17 radiation oncologists on 305 cases. The model achieves a mean Dice of 0.955 and HD95 of 3.78 mm, with the largest gains on low-contrast organs-at-risk (OARs) and target volumes where through-plane context is most critical. The uncertainty head is well-calibrated and supports case-level triage. In the reader study, AI assistance reduced contouring time by 75-80% across experience levels and raised junior-reader IoU from 0.861 to 0.925, matching the unedited model. External validation showed a modest internal-to-external drop (< 5%) with calibrated uncertainty transferring without recalibration. The complete deployment pipeline from DICOM ingestion to TPS-compatible RTSTRUCT export has been integrated into the clinical workflow at a partner hospital, where it is used to assist with contouring. These results suggest that anatomically motivated inter-slice memory, paired with uncertainty-guided review, offers a clinically viable path for thoracic auto-contouring.

0.20