CS Paper Radar

From Vision to Context: A Review of Prompt-Driven Target Volume Segmentation in Radiotherapy

Bakpen Kombat, Guus Grimbergen, Maarten L. Terpstra, Gert J. Meijer, Lois, A. Daamen

eess.IV ·submitted 2026-11-04 14:32 UTC · v1
survey

Abstract

Accurate target volume (TV) segmentation is essential for radiotherapy (RT) planning but remains time-consuming. Moreover, the final contour depends on the expertise of the radiation oncologist. Although deep learning has improved medical image segmentation, image-only models cannot encode the clinical reasoning that governs TV delineation, particularly for the clinical target volume (CTV), where boundaries are defined by clinical knowledge rather than imaging features alone. Prompt-driven segmentation has recently emerged as a strategy to address this limitation. This work aims to review these approaches for RT TV segmentation with four objectives: (1) compare the different prompting techniques used; (2) compare their performance against image-only baselines; (3) assess how they are evaluated against standard metrics, including the Dice similarity coefficient (DSC), 95th Hausdorff distance, sensitivity, precision, and clinical assessment; and (4) identify the gaps needed for clinical translation. We systematically searched PubMed, Embase, and arXiv for studies incorporating geometric, clinical text, or interactive prompts into deep learning models for RT TV delineation. Thirteen studies met the inclusion criteria, spanning head and neck, breast, prostate, lung, cervix, and rectal cancers. Seven studies used clinical text prompting, four used geometric prompting, and two used interactive prompting; three combined modalities. Reported DSC ranged from 0.67 to 0.93, compared to 0.65 to 0.91 for image-only baselines. None reported sensitivity or precision. Clinical text prompting appears well suited to CTV delineation. Evidence remains limited, and standardized prompt engineering and clinical validation are needed before these approaches can be translated into routine RT practice.

Comment
Submitted to Computerized Medical Imaging and Graphics

Closest papers

Nearest neighbours by meaning across the whole index.

Next-Generation Segmentation in Radiotherapy: A Narrative Review from Atlas-Based Methods to Agentic Vision-Language Models

eess.IV physics.med-ph ·2026-11-09 ·Josef A. Buchner, Richard Osuala, Ayhan Can Erdur, Melissa C. Olufs, Stephanie E. Combs +1 more
similarity 0.75
Abstract

Precise segmentation of target volumes and organs at risk is an essential prerequisite for modern, high-precision radiation therapy. However, this task has traditionally been time-consuming and subject to high interobserver variability. Motivated by these limitations, more advanced and novel approaches to automating this task have been developed over the past two decades. This narrative review highlights representative milestones, with a focus on the most recent developments. These approaches include atlas-based label propagation, convolutional architectures, promptable foundation models, and, most recently, vision-language models (VLMs), which integrate clinical text with volumetric segmentation. Each methodological generation has addressed limitations of its predecessor while introducing new ones. A substantial gap remains between research progress and clinical deployment, as routine workflows continue to be dominated by atlas-based and narrow task-specific deep-learning tools, which remain strong baselines in geometric overlap metrics but are highly rigid in terms of application, versatility, portability, and interpretability. As contouring systems further grow in complexity, conventional geometric overlap metrics become insufficient, motivating evaluation paradigms that incorporate surface-based, dosimetric, and prompt-adherence assessment. Emerging agentic architectures that combine large language models, retrieval-augmented generation, and vision-language segmentation modules are leading towards more flexible, guideline-aware, interactive contouring workflows. These systems could automate flexible and interpretable knowledge-based contouring and actively support the clinical reasoning underlying target volume definition.

0.10

RepConTUR: A Report-Conditioned Volumetric Multimodal Model for Abdominal Tumor Segmentation

cs.CV ·2026-10-29 ·Seunghwan Lee, Sangjoon Park, Jongmin Lee, Yoon Jo Kim, Wonyoung Cho +2 more
code/data similarity 0.71
Abstract · Submitted to CVPR 2027

Tumor delineation is required for radiotherapy planning, yet automatic segmentation is limited by errors, predominantly false positives, that distort dose and increase editing time. The radiology report accompanies the scan and localizes disease at the suborgan level, but existing text-promptable models condition on short referring phrases, and most operate in 2D. We present RepConTUR, a single native-3D early-fusion multimodal model that conditions volumetric abdominal tumor segmentation on the narrative report. We extend AbdomenAtlas 3.0 to a suborgan-level promptable segmentation dataset and generate report-based VQA pairs, yielding four report-derived tasks on the same annotations: referring segmentation (RES), report-grounded segmentation (GSEG), report generation (RRG), and visual question answering (VQA). We train RepConTUR, comprising a 3D CT encoder, an early-fusion language model, and a native-3D segmentation module, jointly on the four tasks. Across liver, kidney and pancreas, RepConTUR attains the highest Dice similarity coefficient (DSC), instance-wise precision, and detection F1 among the text-promptable baselines, and adding the report raises mean precision while leaving recall comparable. Against two vision-only specialists, nnU-Net and the report-supervised R-Super, RepConTUR attains the highest value on every in-domain metric for liver and pancreas and the highest mean DSC, recall, precision, and detection F1 over the four out-of-distribution public cohorts. Ablations indicate that conditioning on the narrative report raises detection F1 from 0.499 to 0.528 within the same model, that joint GSEG training raises RES F1 from 0.450 to 0.482, and that the native-3D segmentation module raises GSEG F1 from 0.139 to 0.528 over its 2D counterpart. Code is available at https://github.com/Oncosoft-Research/RepConTUR.

0.20

Anatomy-Change-Aware Bidirectional Selective State-Space Memory for Clinically Deployed Thoracic Radiotherapy Auto-Contouring

eess.IV cs.CV ·2026-09-11 ·Galib Ahmed, Istiak Ahmed, Aritra Islam Saswato, Asib Mostakim Fony, Kazi Shahriar Sanjid +13 more
similarity 0.71
Abstract

We developed DAMM-Net++, a 2.5D architecture for thoracic OAR and target volume segmentation that addresses three persistent challenges in radiotherapy auto-contouring: inter-slice surface incoherence, systematic failure on small low-contrast targets, and the absence of per-case reliability signals. The central component is an anatomy-change-aware bidirectional selective state-space memory that models through-plane anatomical change and selectively propagates context along the axial slice sequence. A boundary-aware decoder sharpens near-surface predictions, and an uncertainty head provides calibrated per-voxel confidence for clinical triage. We evaluated 2,146 patients across four centers, an independent external cohort of 112 patients, and a multicenter reader study involving 17 radiation oncologists on 305 cases. The model achieves a mean Dice of 0.955 and HD95 of 3.78 mm, with the largest gains on low-contrast organs-at-risk (OARs) and target volumes where through-plane context is most critical. The uncertainty head is well-calibrated and supports case-level triage. In the reader study, AI assistance reduced contouring time by 75-80% across experience levels and raised junior-reader IoU from 0.861 to 0.925, matching the unedited model. External validation showed a modest internal-to-external drop (< 5%) with calibrated uncertainty transferring without recalibration. The complete deployment pipeline from DICOM ingestion to TPS-compatible RTSTRUCT export has been integrated into the clinical workflow at a partner hospital, where it is used to assist with contouring. These results suggest that anatomically motivated inter-slice memory, paired with uncertainty-guided review, offers a clinically viable path for thoracic auto-contouring.

0.20

Improving Clinical Target Volume Segmentation Accuracy using Anatomical Priors and Active Learning for the AGITG TOPGEAR Clinical Trial

cs.CV physics.med-ph ·2026-09-02 ·Phillip Chlap, Mark Lee, Trevor Leong, Matthew Field, Jason Dowling +9 more
similarity 0.68
Abstract

Training deep learning-based medical image segmentation models is challenging with limited curated datasets. For AGITG TOPGEAR, a gastric cancer trial, the Clinical Target Volume (CTV) is complex and defined by multiple anatomical landmarks, making upfront training data preparation difficult for an automated contour QA segmentation model. We investigate anatomical priors, derived from surrounding organ segmentations, to provide spatial context and improve TOPGEAR CTV segmentation accuracy. We also evaluate active learning, iteratively expanding the training dataset by selecting cases expected to improve performance. One hundred TOPGEAR CT scans were retrospectively analyzed. An initial set of 10 expert-contoured cases was used to train an nnU-Net model. TotalSegmentator generated a voxel-wise anatomical prior map from surrounding structures as an additional input channel. Active learning was simulated over four iterations, selecting cases by model uncertainty and segmentation performance. All models used five-fold cross-validation for an ensemble uncertainty measure. Evaluation used a hold-out testing set of 50 cases. The anatomical prior improved CTV segmentation accuracy, increasing mean Dice Similarity Coefficient (DSC) from 0.84 to 0.86. Active learning similarly improved performance to 0.86, with greatest benefit in the final round. Combining the anatomical prior with active learning achieved the highest accuracy, with a DSC of 0.87. Model uncertainty correlated with DSC, supporting its use in identifying suboptimal predictions and guiding active learning. Anatomical priors and active learning each improved CTV segmentation accuracy and generalizability, with their combination achieving the best performance, supporting integration into segmentation model development for automated contour QA in radiotherapy clinical trials.

0.16

Volumetric Radiology AI in the Era of Multimodal Large Language Models

cs.AI ·2026-08-20 ·Zanting Ye, Shengyuan Liu, Xin Liu, Chenhui Wang, Zhisong Wang +14 more
similarity 0.68
Abstract · 9 Figures, 6 tables

Advances in multimodal large language models (MLLMs) are extending radiological artificial intelligence (AI) beyond task-specific image analysis toward multimodal understanding and reasoning. Volumetric radiology, however, presents a fundamental representational mismatch: clinical interpretation often requires full-volume spatial context and acquisition-dependent quantitative information, whereas current MLLMs are commonly conditioned on selected two-dimensional (2D) images, compressed visual representations, or report-derived text. Reliable volumetric radiology AI therefore requires representations that preserve task-relevant three-dimensional (3D) information and systems that can access, verify, and integrate this information across clinical workflows. In this Review, we examine more than 200 publications through July 2026. We organize the literature around volumetric representation and multimodal understanding at the model level, agentic orchestration at the system level, and their links to clinical applications and evaluation. We review volumetric foundation models, language alignment and compression strategies, and agentic systems that extend MLLMs through planning, tools, memory, and workflow interaction. We distinguish settings in which selected 2D views or report-mediated reasoning may suffice from those that warrant native volumetric modeling. We also introduce a Claim-Design-Validation framework to assess whether technical, workflow, and clinical claims are matched by appropriate design and validation. Across the literature, native volumetric modeling and agentic capabilities depend on the spatial, quantitative, contextual, and workflow requirements of the intended task. Clinical credibility requires faithful volumetric representation, traceable system behavior, claim-aligned validation, and clearly defined human oversight in realistic workflows.

0.37

Multi-Stage Prompt-Guided Feature Modulation for Generalizable Brain Tumor Segmentation

eess.IV cs.CV ·2026-08-24 ·Mohammad Mahdi Danesh Pajouh, Sara Saeedi
published similarity 0.68
Abstract · Accepted to BraTS MICCAI 2026 Task 3 (Generalizability Across Tumors)

Accurate brain tumor segmentation from magnetic resonance imaging (MRI) is essential for diagnosis, treatment planning, surgical guidance, and disease monitoring. However, developing automated segmentation models that generalize across diverse tumor characteristics, imaging protocols, acquisition sites, and patient populations remains challenging. Variations in tumor morphology and imaging distributions can substantially degrade performance outside the training domain. Consequently, improving the robustness and generalization of deep learning-based segmentation models has become a key objective in medical image analysis. To improve segmentation robustness, we propose Multi-Stage Dynamic Prompt nnU-Net, a prompt-conditioned extension of nnU-Net. Three independent dynamic prompt modules are inserted into the deepest encoder stages. Each module contains a learnable bank of ten 256-dimensional prompt vectors and uses globally pooled encoder features to generate image-specific prompt representations. These representations are projected into feature-wise scaling $(γ)$ and shifting $(β)$ parameters that modulate encoder feature maps through Feature-wise Linear Modulation (FiLM), enabling adaptive feature conditioning at multiple semantic levels. Evaluation on the BraTS GOAT validation dataset demonstrated that the proposed Multi-Stage Dynamic Prompt nnU-Net outperformed the baseline nnU Net across the majority of evaluated metrics and tumor subregions. The proposed model achieved average lesion-wise Dice scores of 76.16% (ET), 80.04% (TC), and 86.42% (WT), compared with 74.38%, 78.14% and 84.01% for the baseline model. The results demonstrate that multi-stage dynamic prompt conditioning improves segmentation accuracy and boundary delineation for brain tumor segmentation.

0.21

Impact of Pretraining Length, Model Size, and Annotation Budget on Downstream Clinical Tasks of Foundation Models in Radiotherapy

cs.CV ·2026-11-17 ·Alejandro Cortina Uribe, Sidsel Højklint Poulsen, Ivan Richter Vogelius, Jens Petersen
code/data similarity 0.67
Abstract · 9 pages, 5 figures, 2 tables. Supplementary Material included

Cone-beam CT (CBCT) scans acquired during radiotherapy capture changes such as tumor shrinkage and radiation-induced tissue changes, offering great potential for foundation models that help monitor individual treatment responses. However, to our knowledge, no large-scale pretrained models for radiotherapy CBCT exist, and evaluating modeling choices is difficult since downstream tasks are not known in advance. We examine how pretraining length, model size, and finetuning strategy relate to downstream clinical performance, and how metrics tracked during pretraining correlate with it. We pretrain vision transformer encoders with masked image modeling on about 150,000 raw 3D radiotherapy CBCT scans, tracking representation quality via validation loss, effective rank, and linear probing. Downstream tasks are classification of feeding tube presence ($n=51,135$ CBCTs, $1,562$ patients) and clinical characteristics (T-, N-stage, sex, age, tumor site; $n=1,278$ patients) in head and neck cancer. We compare low-rank adaptation (LoRA) and full finetuning against no pretraining, varying annotated dataset size. Pretext validation loss was the most consistent predictor of downstream performance; effective rank and linear probing were also associated, but not consistently across model sizes and finetuning methods. LoRA performed comparably to full finetuning while training only 0.5-2.5% of the parameters. Fully finetuned models consistently outperformed models without pretraining across all sizes, with AUROC 0.91-0.97 vs. 0.58-0.85 for feeding tube classification and 0.99-1.00 vs. 0.71-0.97 for sex classification. Model size had only a small, inconsistent effect, suggesting smaller models suffice at lower computational cost. Code and pretrained models (non-commercial license): https://github.com/alexCortinaU/RT-CBCT_SSL

0.48

Learning the Dose Manifold: A Latent Diffusion Framework for Volumetric Dose Prediction in Automated Radiotherapy Treatment Planning

cs.CV ·2026-10-19 ·J. Boyer-Chammard, R. Vauclin, M. C. Biston, P. Maury, M. Gau +5 more
similarity 0.67
Abstract · 27 pages, 7 figures plus graphical abstract

Automated treatment planning (ATP) aims to reduce the unwarranted inter-planner variability of manual planning, while improving treatment quality and efficiency. Most ATP pipelines rely on the prediction of the achievable three-dimensional dose distribution for a given anatomy and the subsequent optimization of machine parameters to reproduce it. Diffusion-based methods are largely slice-wise due to the high dimensionality of radiotherapy data, and assume a one-to-one mapping between anatomy and optimal dose despite the multi-objective nature of treatment planning. They are evaluated on their ability to match reference doses and rarely on their integration in ATP frameworks. We present LaDose, a latent diffusion framework for fully volumetric dose prediction. An autoencoder learned on dose distributions, trained so that perturbed latents decode to plausible doses, compresses dose maps 128-fold and enables 3D diffusion on a single GPU. Prescription values are represented as exact scalar vectors that bypass the image encoder, avoiding resampling and latent compression. Multiscale classifier-free guidance allows for the modulation of clinical trade-offs at inference, without retraining or additional labeled data. On 900 clinically delivered head-and-neck volumetric modulated arc therapy plans from five centers, LaDose reached a median absolute error of 1.18 Gy (1.4--1.8\% of the prescription) and was the only one of six frameworks free of systematic bias with respect to the reference distribution. Guidance scales acted predictably on target coverage and organ-at-risk sparing. Integrated with direct aperture optimization, the pipeline generated plans in 15.2 minutes; in a blinded review, senior clinicians rated 14 of 15 plans acceptable without editing.

0.12