CS Paper Radar

Learning the Dose Manifold: A Latent Diffusion Framework for Volumetric Dose Prediction in Automated Radiotherapy Treatment Planning

J. Boyer-Chammard, R. Vauclin, M. C. Biston, P. Maury, M. Gau, S. Stathakis, V. Grégoire, N. Paragios, E. Deutsch, N. Komodakis

cs.CV ·submitted 2026-10-19 09:24 UTC · v1

Abstract

Automated treatment planning (ATP) aims to reduce the unwarranted inter-planner variability of manual planning, while improving treatment quality and efficiency. Most ATP pipelines rely on the prediction of the achievable three-dimensional dose distribution for a given anatomy and the subsequent optimization of machine parameters to reproduce it. Diffusion-based methods are largely slice-wise due to the high dimensionality of radiotherapy data, and assume a one-to-one mapping between anatomy and optimal dose despite the multi-objective nature of treatment planning. They are evaluated on their ability to match reference doses and rarely on their integration in ATP frameworks. We present LaDose, a latent diffusion framework for fully volumetric dose prediction. An autoencoder learned on dose distributions, trained so that perturbed latents decode to plausible doses, compresses dose maps 128-fold and enables 3D diffusion on a single GPU. Prescription values are represented as exact scalar vectors that bypass the image encoder, avoiding resampling and latent compression. Multiscale classifier-free guidance allows for the modulation of clinical trade-offs at inference, without retraining or additional labeled data. On 900 clinically delivered head-and-neck volumetric modulated arc therapy plans from five centers, LaDose reached a median absolute error of 1.18 Gy (1.4--1.8\% of the prescription) and was the only one of six frameworks free of systematic bias with respect to the reference distribution. Guidance scales acted predictably on target coverage and organ-at-risk sparing. Integrated with direct aperture optimization, the pipeline generated plans in 15.2 minutes; in a blinded review, senior clinicians rated 14 of 15 plans acceptable without editing.

Comment
27 pages, 7 figures plus graphical abstract

Closest papers

Nearest neighbours by meaning across the whole index.

Dose-PlanNet: Physics Based Radiotherapy Dose Prediction with Deep Learning

cs.CV physics.med-phcs.LG ·2026-08-27 ·Ankit Bhattacharjee, Sougata Maity, Santam Chakraborty, Indranil Mallick
code/data similarity 0.75
Abstract · The paper consists of 22 pages, 4 figures, 6 tables. The end-to-end pipeline of Dose-PlanNet will soon be made available on the GitHub repos…

Automating prostate radiotherapy treatment planning is dosimetrically complex, particularly for extreme hypofractionated regimens. In this study, we introduce Dose-PlanNet, a physics-guided 3D deep learning architecture designed to predict dose distributions. This model's performance was evaluated on a cohort of patients treated in a prospective trial where two different dose fractionation regimens were employed. Dose-PlanNet achieved comparable target coverage ($D_{95}$), though statistical analysis revealed a marginal reduction in target homogeneity ($p<0.001$) offset. However the model achieved statistically significant improvements in high-dose organ-at-risk sparing ($p<0.001$). When evaluated against strict Prospective Randomized protocol volumetric constraints, automated plans met prespecified clinical acceptance criteria in $11$ out of $14$ Moderate Hypofraction Arm plans and $9$ out of $12$ Stereotactic Body Radiation Therapy Arm plans. This pipeline demonstrates that physics-informed deep learning can accelerate radiotherapy workflows while safely maintaining the stringent dosimetric quality required for high-precision clinical deployment.

0.36

Latent-to-Latent Flow for Volumetric Stochastic Segmentation

cs.CV cs.AIcs.LG ·2026-09-07 ·Omar Todd, Sooha Kim, Raghav Mehta, Katherine Mackay, David Bernstein +3 more
top venue similarity 0.72
Abstract · Accepted at MICCAI 2026

Uncertainty arising from inter-observer variability in medical image segmentation plays an important role in developing treatment plans. Research in this area is inhibited by the lack of multiple annotations for large-scale medical datasets, especially for volumetric data, which suffers from additional scaling and computational complexity challenges. Flow matching has emerged as a powerful framework for generative modelling and has also been demonstrated to maintain strong performance when working with latent representations of images. In this work, we introduce a latent-to-latent flow technique for stochastic segmentation of medical volumes via encoded representations of both the image and label space. We evaluate our method on two challenging applications covering delineation uncertainty for radiotherapy planning and multiple organ structure segmentation, improving efficiency up to 14x compared with full resolution models while maintaining clinically relevant performance.

0.33

Optimization of Deep Learning Model for Denoising Dose Profiles in Proton Therapy

eess.IV q-bio.QM ·2026-09-30 ·Junaid Jawaid, Matteo Spezialetti, Gabriele Libardi, Giovanni Stilo, Filippo Mignosi
similarity 0.70
Abstract

Proton therapy offers a dosimetric advantage over conventional radiotherapy through the Bragg peak, enabling precise dose delivery to the tumour while sparing surrounding tissue. Monte Carlo (MC) simulation provides the most accurate dose calculation but is computationally expensive for clinical workflows. A promising compromise is to simulate with a reduced number of primary histories and recover a high-quality dose distribution through a deep learning denoising step. In this work, we take a 3D multiscale U-Net from recent literature as a case study and investigate two improvements critical for clinical deployment. First, we replace the standard MSE training objective with a differentiable $γ$-index-based loss, extended to native 3D operation, and demonstrate that directly optimising the clinical evaluation metric yields a mean Gamma Passing Rate of 99.47\% at 2mm/2\% and 95.67\% at 1mm/1\% on the test set, compared to 92.10\% and 71.13\% for MSE. Second, we apply L1-norm structured filter pruning to reduce the model's memory footprint, achieving a 13.3\% parameter reduction with negligible performance loss under partial pruning, and 20\% reduction under full-block pruning after fine-tuning.

0.09

Multimodal Deep Learning for Uncertainty-Aware Radiation Pneumonitis Risk Prediction

eess.IV ·2026-08-28 ·Jin Yang, Tian Liu, Jing Wang, Sooyun Caroline Tavolacci, Benjamin Tran +5 more
similarity 0.68
Abstract · 28 pages, 9 figures, 5 tables

Radiation pneumonitis (RP) is a potentially serious complication of thoracic radiotherapy, making reliable risk prediction important for identifying high-risk patients and guiding effective toxicity management. Although deep learning models can predict RP risk, uncertainty quantification remains underdeveloped in radiation toxicity assessment. We developed a Multimodal Bayesian Diffusion Transformer (MM-DiT) that integrates pretreatment computed tomography (CT) and three-dimensional planning dose distributions for RP risk prediction and uncertainty quantification. MM-DiT combines self-supervised multimodal representation learning with Bayesian classification to estimate individual risk and characterize aleatoric, epistemic, and label uncertainty. In independent Mount Sinai Health System (MSHS) and RTOG cohorts, MM-DiT achieved areas under the receiver operating characteristic curve (AUCs) of $0.89$ and $0.86$, respectively, with expected calibration errors of $0.02$ and $0.03$. Incorporating post-treatment CT increased AUC to $0.95$ in MSHS and reduced aleatoric and epistemic uncertainty by approximately $40-45\%$ and $40\%$, respectively. These findings establish a framework for uncertainty-aware radiation toxicity prediction that complements risk estimates with information about predictive reliability. By integrating multimodal learning and uncertainty quantification, MM-DiT may advance more interpretable and trustworthy AI-assisted toxicity assessment and support individualized radiotherapy planning.

0.19

Volumetric Latent Diffusion for Brain Tumour Segmentation with Missing Modalities

eess.IV ·2026-11-05 ·Toan Nguyen Hai, Hung Nguyen Tuan, Ba Luong Son, Huynh Trinh Ngoc
similarity 0.67
Abstract

Brain tumour segmentation from magnetic resonance imaging normally assumes that all four imaging sequences are available, but in clinical practice one or more are frequently missing. Existing methods for incomplete inputs learn modality-invariant representations or distil from a full-modality teacher, and return a single deterministic mask. Gen- erative formulations instead model a distribution over plausible masks, but the cost of sampling at full resolution has largely confined them to two dimensions. This paper proposes a three-dimensional conditional latent diffusion framework for whole-tumour segmentation from incom- plete multi-sequence MRI. Images and annotations are first compressed by two volumetric autoencoders, which makes diffusion over whole vol- umes affordable, and sequences are dropped at random during training so that a single model handles every combination of missing sequences. Because the model samples rather than predicts, repeated draws also yield a voxel-wise map of disagreement at no extra training cost. Evalu- ations on 2,601 studies from BraTS 2023 and 2024 show that the method reaches 0.955 Dice with all four sequences and 0.904 with FLAIR alone, and that it is the most accurate of the four methods compared in eight of the fifteen configurations. The disagreement between draws widens as sequences are withheld, giving a signal that accompanies the prediction rather than replacing it

0.21

DoseBridge: Denoising Diffusion Bridge Model for Dose Prediction in Lung Intensity-Modulated Proton Therapy

cs.CV ·2026-08-10 ·Zerun Zhang, Xiaoda Cong, Xiangkun Xu, Peter Y. Chen, Xuanfeng Ding
similarity 0.67
Abstract

Most radiotherapy dose-prediction models use only CT images and anatomical structures, although intensity-modulated proton therapy (IMPT) dose also depends strongly on beam geometry and available clinical datasets are often small. We present DoseBridge, a denoising diffusion bridge model that uses the patient CT as a structured bridge endpoint and encodes plan-specific beam geometry in a spatially aligned beam mask. Multiscale fusion combines CT, target, organ-at-risk, and beam-mask representations with 1.95% additional parameters. DoseBridge was retrospectively evaluated on single-institution CT images and treatment plans from 52 patients with advanced-stage lung cancer treated with 60 Gy in 30 fractions; 42 cases were used for training and 10 for testing. Performance was assessed using image-similarity, dose-volume, and Lyman-Kutcher-Burman normal-tissue complication probability (NTCP) metrics and compared with two deep-learning models. On the test cohort, DoseBridge achieved a mean absolute error of 4.170 Gy, peak signal-to-noise ratio of 23.06 dB, and structural similarity index of 0.798, outperforming both comparison models on these metrics. Clinical target volume D95 differed from the reference dose by 0.62 +/- 1.6 Gy; signed organ-at-risk mean-dose differences ranged from -0.32 to 0.24 Gy, and NTCP differences were -0.40 +/- 2.2 and 0.52 +/- 3.4 percentage points for acute esophagitis and radiation pneumonitis, respectively. Changing only the beam mask redirected predicted low-dose entrance regions while preserving the high-dose target region. To our knowledge, DoseBridge is the first denoising diffusion bridge model for radiotherapy dose prediction. These results support its feasibility as a beam-aware planning prior for lung IMPT, pending evaluation in larger external cohorts.

0.04

From Vision to Context: A Review of Prompt-Driven Target Volume Segmentation in Radiotherapy

eess.IV ·2026-11-04 ·Bakpen Kombat, Guus Grimbergen, Maarten L. Terpstra, Gert J. Meijer, Lois +1 more
survey similarity 0.67
Abstract · Submitted to Computerized Medical Imaging and Graphics

Accurate target volume (TV) segmentation is essential for radiotherapy (RT) planning but remains time-consuming. Moreover, the final contour depends on the expertise of the radiation oncologist. Although deep learning has improved medical image segmentation, image-only models cannot encode the clinical reasoning that governs TV delineation, particularly for the clinical target volume (CTV), where boundaries are defined by clinical knowledge rather than imaging features alone. Prompt-driven segmentation has recently emerged as a strategy to address this limitation. This work aims to review these approaches for RT TV segmentation with four objectives: (1) compare the different prompting techniques used; (2) compare their performance against image-only baselines; (3) assess how they are evaluated against standard metrics, including the Dice similarity coefficient (DSC), 95th Hausdorff distance, sensitivity, precision, and clinical assessment; and (4) identify the gaps needed for clinical translation. We systematically searched PubMed, Embase, and arXiv for studies incorporating geometric, clinical text, or interactive prompts into deep learning models for RT TV delineation. Thirteen studies met the inclusion criteria, spanning head and neck, breast, prostate, lung, cervix, and rectal cancers. Seven studies used clinical text prompting, four used geometric prompting, and two used interactive prompting; three combined modalities. Reported DSC ranged from 0.67 to 0.93, compared to 0.65 to 0.91 for image-only baselines. None reported sensitivity or precision. Clinical text prompting appears well suited to CTV delineation. Evidence remains limited, and standardized prompt engineering and clinical validation are needed before these approaches can be translated into routine RT practice.

0.23

MUMINS: Metadata-conditioned Uncertainty-aware Medical Image Next-state Synthesis

cs.CV cs.AI ·2026-09-15 ·Anna Oliveras, Roger Marí, Rafael Redondo, Oriol Guardià, Cynthia Ifeyinwa Ugwu +5 more
code/data similarity 0.67
Abstract · Supplementary material to follow in future versions

Forecasting anatomical changes such as tumor growth and neurodegeneration is a challenging generative vision task. Morphological evolution is subtle relative to static anatomy, highly patient-specific, and inherently stochastic. Existing methods struggle with several issues: deterministic networks ignore biological stochasticity, while standard diffusion models require computationally prohibitive multi-pass sampling to quantify uncertainty. We propose MUMINS (Metadata-conditioned Uncertainty-aware Medical Image Next-state Synthesis), an efficient diffusion framework that jointly diffuses a baseline scan and its follow-up residual, summed to synthesize the follow-up scan, while concurrently predicting a spatial uncertainty map, in a single reverse diffusion process. Conditioned on the time interval and relevant metadata, it preserves fine-grained anatomy by dynamically re-injecting the baseline as a soft anchor at every denoising step, and a negative-log-likelihood head learns the uncertainty map to explicitly flag error-prone regions. Designed without organ-specific heuristics, the same architecture is reused across anatomies via separate, dataset-specific retraining. Extensive evaluations demonstrate that dataset-specific retraining of MUMINS matches or outperforms dedicated, domain-specific state-of-the-art methods on lung CT (PNG) and brain MRI (OASIS-3). Project page: https://aolivtous.github.io/publications/mumins.html.

0.47