CS Paper Radar

Dose-PlanNet: Physics Based Radiotherapy Dose Prediction with Deep Learning

Ankit Bhattacharjee, Sougata Maity, Santam Chakraborty, Indranil Mallick

cs.CV physics.med-phcs.LG ·submitted 2026-08-27 10:05 UTC · v1
code/data

Abstract

Automating prostate radiotherapy treatment planning is dosimetrically complex, particularly for extreme hypofractionated regimens. In this study, we introduce Dose-PlanNet, a physics-guided 3D deep learning architecture designed to predict dose distributions. This model's performance was evaluated on a cohort of patients treated in a prospective trial where two different dose fractionation regimens were employed. Dose-PlanNet achieved comparable target coverage ($D_{95}$), though statistical analysis revealed a marginal reduction in target homogeneity ($p<0.001$) offset. However the model achieved statistically significant improvements in high-dose organ-at-risk sparing ($p<0.001$). When evaluated against strict Prospective Randomized protocol volumetric constraints, automated plans met prespecified clinical acceptance criteria in $11$ out of $14$ Moderate Hypofraction Arm plans and $9$ out of $12$ Stereotactic Body Radiation Therapy Arm plans. This pipeline demonstrates that physics-informed deep learning can accelerate radiotherapy workflows while safely maintaining the stringent dosimetric quality required for high-precision clinical deployment.

Comment
The paper consists of 22 pages, 4 figures, 6 tables. The end-to-end pipeline of Dose-PlanNet will soon be made available on the GitHub repository of CHAVI-India (https://github.com/CHAVI-India)

Closest papers

Nearest neighbours by meaning across the whole index.

Learning the Dose Manifold: A Latent Diffusion Framework for Volumetric Dose Prediction in Automated Radiotherapy Treatment Planning

cs.CV ·2026-10-19 ·J. Boyer-Chammard, R. Vauclin, M. C. Biston, P. Maury, M. Gau +5 more
similarity 0.75
Abstract · 27 pages, 7 figures plus graphical abstract

Automated treatment planning (ATP) aims to reduce the unwarranted inter-planner variability of manual planning, while improving treatment quality and efficiency. Most ATP pipelines rely on the prediction of the achievable three-dimensional dose distribution for a given anatomy and the subsequent optimization of machine parameters to reproduce it. Diffusion-based methods are largely slice-wise due to the high dimensionality of radiotherapy data, and assume a one-to-one mapping between anatomy and optimal dose despite the multi-objective nature of treatment planning. They are evaluated on their ability to match reference doses and rarely on their integration in ATP frameworks. We present LaDose, a latent diffusion framework for fully volumetric dose prediction. An autoencoder learned on dose distributions, trained so that perturbed latents decode to plausible doses, compresses dose maps 128-fold and enables 3D diffusion on a single GPU. Prescription values are represented as exact scalar vectors that bypass the image encoder, avoiding resampling and latent compression. Multiscale classifier-free guidance allows for the modulation of clinical trade-offs at inference, without retraining or additional labeled data. On 900 clinically delivered head-and-neck volumetric modulated arc therapy plans from five centers, LaDose reached a median absolute error of 1.18 Gy (1.4--1.8\% of the prescription) and was the only one of six frameworks free of systematic bias with respect to the reference distribution. Guidance scales acted predictably on target coverage and organ-at-risk sparing. Integrated with direct aperture optimization, the pipeline generated plans in 15.2 minutes; in a blinded review, senior clinicians rated 14 of 15 plans acceptable without editing.

0.12

Optimization of Deep Learning Model for Denoising Dose Profiles in Proton Therapy

eess.IV q-bio.QM ·2026-09-30 ·Junaid Jawaid, Matteo Spezialetti, Gabriele Libardi, Giovanni Stilo, Filippo Mignosi
similarity 0.75
Abstract

Proton therapy offers a dosimetric advantage over conventional radiotherapy through the Bragg peak, enabling precise dose delivery to the tumour while sparing surrounding tissue. Monte Carlo (MC) simulation provides the most accurate dose calculation but is computationally expensive for clinical workflows. A promising compromise is to simulate with a reduced number of primary histories and recover a high-quality dose distribution through a deep learning denoising step. In this work, we take a 3D multiscale U-Net from recent literature as a case study and investigate two improvements critical for clinical deployment. First, we replace the standard MSE training objective with a differentiable $γ$-index-based loss, extended to native 3D operation, and demonstrate that directly optimising the clinical evaluation metric yields a mean Gamma Passing Rate of 99.47\% at 2mm/2\% and 95.67\% at 1mm/1\% on the test set, compared to 92.10\% and 71.13\% for MSE. Second, we apply L1-norm structured filter pruning to reduce the model's memory footprint, achieving a 13.3\% parameter reduction with negligible performance loss under partial pruning, and 20\% reduction under full-block pruning after fine-tuning.

0.09

From Vision to Context: A Review of Prompt-Driven Target Volume Segmentation in Radiotherapy

eess.IV ·2026-11-04 ·Bakpen Kombat, Guus Grimbergen, Maarten L. Terpstra, Gert J. Meijer, Lois +1 more
survey similarity 0.66
Abstract · Submitted to Computerized Medical Imaging and Graphics

Accurate target volume (TV) segmentation is essential for radiotherapy (RT) planning but remains time-consuming. Moreover, the final contour depends on the expertise of the radiation oncologist. Although deep learning has improved medical image segmentation, image-only models cannot encode the clinical reasoning that governs TV delineation, particularly for the clinical target volume (CTV), where boundaries are defined by clinical knowledge rather than imaging features alone. Prompt-driven segmentation has recently emerged as a strategy to address this limitation. This work aims to review these approaches for RT TV segmentation with four objectives: (1) compare the different prompting techniques used; (2) compare their performance against image-only baselines; (3) assess how they are evaluated against standard metrics, including the Dice similarity coefficient (DSC), 95th Hausdorff distance, sensitivity, precision, and clinical assessment; and (4) identify the gaps needed for clinical translation. We systematically searched PubMed, Embase, and arXiv for studies incorporating geometric, clinical text, or interactive prompts into deep learning models for RT TV delineation. Thirteen studies met the inclusion criteria, spanning head and neck, breast, prostate, lung, cervix, and rectal cancers. Seven studies used clinical text prompting, four used geometric prompting, and two used interactive prompting; three combined modalities. Reported DSC ranged from 0.67 to 0.93, compared to 0.65 to 0.91 for image-only baselines. None reported sensitivity or precision. Clinical text prompting appears well suited to CTV delineation. Evidence remains limited, and standardized prompt engineering and clinical validation are needed before these approaches can be translated into routine RT practice.

0.23

Physics-Informed Deep Learning in Oncology

cs.CE ·2026-10-13 ·Scindhiya Laxmi, Vivek S. Yadav, Ameya D. Jagtap
similarity 0.65
Abstract · 51 pages

Deep learning has enabled substantial advances in oncology, including cancer detection and diagnosis, medical image analysis, tumor characterization, treatment planning, response assessment, and outcome prediction. However, conventional data-driven models often require large annotated datasets, exhibit limited generalization across heterogeneous clinical settings, and lack explicit mechanisms for incorporating the physical, physiological, and biological principles underlying cancer development and treatment. Physics-informed deep learning (PIDL) integrates governing physical laws, mechanistic models, physiological constraints, and domain knowledge into deep learning frameworks, providing a principled approach for learning from sparse, noisy, and heterogeneous oncological data. This review presents a task-oriented synthesis of PIDL methods across oncology, encompassing neural networks, Kolmogorov-Arnold networks, convolutional and vision architectures, neural operators, generative models, and hybrid physics-data-driven frameworks. Their applications are examined across cancer detection and diagnosis, image reconstruction and analysis, tumor characterization, quantitative imaging, tumor progression, treatment response, radiation therapy, treatment planning, and multimodal clinical modeling. Based on the synthesized methodological and application-level evidence, we develop task-optimized PIDL workflows that align the clinical task with appropriate data representations, physical constraints, model architectures, and validation strategies. We further analyze key challenges, including physical-model fidelity, computational scalability, uncertainty quantification, domain generalization, standardized benchmarking, and clinical validation.

0.09

Multimodal Deep Learning for Uncertainty-Aware Radiation Pneumonitis Risk Prediction

eess.IV ·2026-08-28 ·Jin Yang, Tian Liu, Jing Wang, Sooyun Caroline Tavolacci, Benjamin Tran +5 more
similarity 0.64
Abstract · 28 pages, 9 figures, 5 tables

Radiation pneumonitis (RP) is a potentially serious complication of thoracic radiotherapy, making reliable risk prediction important for identifying high-risk patients and guiding effective toxicity management. Although deep learning models can predict RP risk, uncertainty quantification remains underdeveloped in radiation toxicity assessment. We developed a Multimodal Bayesian Diffusion Transformer (MM-DiT) that integrates pretreatment computed tomography (CT) and three-dimensional planning dose distributions for RP risk prediction and uncertainty quantification. MM-DiT combines self-supervised multimodal representation learning with Bayesian classification to estimate individual risk and characterize aleatoric, epistemic, and label uncertainty. In independent Mount Sinai Health System (MSHS) and RTOG cohorts, MM-DiT achieved areas under the receiver operating characteristic curve (AUCs) of $0.89$ and $0.86$, respectively, with expected calibration errors of $0.02$ and $0.03$. Incorporating post-treatment CT increased AUC to $0.95$ in MSHS and reduced aleatoric and epistemic uncertainty by approximately $40-45\%$ and $40\%$, respectively. These findings establish a framework for uncertainty-aware radiation toxicity prediction that complements risk estimates with information about predictive reliability. By integrating multimodal learning and uncertainty quantification, MM-DiT may advance more interpretable and trustworthy AI-assisted toxicity assessment and support individualized radiotherapy planning.

0.19

DoseBridge: Denoising Diffusion Bridge Model for Dose Prediction in Lung Intensity-Modulated Proton Therapy

cs.CV ·2026-08-10 ·Zerun Zhang, Xiaoda Cong, Xiangkun Xu, Peter Y. Chen, Xuanfeng Ding
similarity 0.62
Abstract

Most radiotherapy dose-prediction models use only CT images and anatomical structures, although intensity-modulated proton therapy (IMPT) dose also depends strongly on beam geometry and available clinical datasets are often small. We present DoseBridge, a denoising diffusion bridge model that uses the patient CT as a structured bridge endpoint and encodes plan-specific beam geometry in a spatially aligned beam mask. Multiscale fusion combines CT, target, organ-at-risk, and beam-mask representations with 1.95% additional parameters. DoseBridge was retrospectively evaluated on single-institution CT images and treatment plans from 52 patients with advanced-stage lung cancer treated with 60 Gy in 30 fractions; 42 cases were used for training and 10 for testing. Performance was assessed using image-similarity, dose-volume, and Lyman-Kutcher-Burman normal-tissue complication probability (NTCP) metrics and compared with two deep-learning models. On the test cohort, DoseBridge achieved a mean absolute error of 4.170 Gy, peak signal-to-noise ratio of 23.06 dB, and structural similarity index of 0.798, outperforming both comparison models on these metrics. Clinical target volume D95 differed from the reference dose by 0.62 +/- 1.6 Gy; signed organ-at-risk mean-dose differences ranged from -0.32 to 0.24 Gy, and NTCP differences were -0.40 +/- 2.2 and 0.52 +/- 3.4 percentage points for acute esophagitis and radiation pneumonitis, respectively. Changing only the beam mask redirected predicted low-dose entrance regions while preserving the high-dose target region. To our knowledge, DoseBridge is the first denoising diffusion bridge model for radiotherapy dose prediction. These results support its feasibility as a beam-aware planning prior for lung IMPT, pending evaluation in larger external cohorts.

0.04

Early Prediction of Pathological Complete Response to Neoadjuvant Chemotherapy Using Temporal Deep Learning on DWI

cs.AI ·2026-08-18 ·Pablo García Marcos, Md. Tarequl Islam, Paula Puerta González, Guillermo Lorenzo, Héctor Gómez +3 more
similarity 0.62
Abstract

Early identification of non-responders to neoadjuvant chemotherapy (NACT) is crucial for timely treatment adaptation in breast cancer. However, many existing predictive models rely on multiparametric magnetic resonance imaging (MRI), late treatment time points, or extensive clinical data, which limits their applicability. This study proposes a deep learning framework for early prediction of pathological complete response (pCR) using only diffusion-weighted MRI (DW-MRI) acquired at baseline and after the first NACT cycle. This framework feeds cropped tumor-centered patches to an EfficientNet-based temporal model that directly learns tumor shape and local tissue characteristics without explicit radiomic feature engineering. The model, trained with 10-fold cross-validation, achieved an area under the receiver operating characteristic curve (AUC) of 0.90 for pCR prediction after one cycle, providing actionable information after a single treatment cycle while avoiding gadolinium administration and reducing dependence on heterogeneous clinical data. By focusing on the baseline-to-first-cycle window instead of later stages, the approach supports earlier escalation or de-escalation of NACT, and its exclusive reliance on DW-MRI facilitates protocol standardization, multi-centre deployment and privacy-preserving data sharing. These results demonstrate that DW-MRI-based deep learning on tumor-centered patches constitutes a minimally invasive, clinically deployable strategy for early pCR prediction, with direct implications for personalized treatment adaptation in neoadjuvant breast cancer therapy.

0.21

Adaptive Chemotherapy Control under Tumor Heterogeneity via Reinforcement Learning

cs.LG eess.SY ·2026-09-10 ·Bereket Sitotaw Kidane, Md Samiul Haque Motayed, Shuo Wang
publishedbenchmark similarity 0.62
Abstract · 6 pages. Published in the 2026 American Control Conference (ACC)

Designing effective chemotherapy regimens is hindered by tumor heterogeneity and drug resistance, which complicate the deployment of patient-specific model-based optimal control across diverse populations. We develop and compare closed-loop deep reinforcement learning (DRL) dosing policies with continuous (TD3) and discrete (DQN) action spaces trained on a high-dimensional heterogeneous tumor model. The DRL policies are benchmarked against a Pontryagin's Maximum Principle (PMP)-derived open-loop benchmark. We assess generalization under parametric heterogeneity using a 100-patient virtual cohort with plus or minus 10 percent uniform perturbations in growth and drug-sensitivity parameters. Across this cohort, TD3 achieves higher average tumor reduction, while DQN yields tighter inter-patient dosing consistency, revealing a clear efficacy-consistency trade-off in this study. Our simulations assume full observation of all tumor subpopulations; translation to sparse and noisy clinical measurements will require partial-observability formulations and/or state estimation. Overall, the results show that simulation-trained DRL can learn state-dependent feedback dosing policies that complement open-loop optimal control benchmarks.

0.33