CS Paper Radar

Physics-Informed Deep Learning in Oncology

Scindhiya Laxmi, Vivek S. Yadav, Ameya D. Jagtap

cs.CE ·submitted 2026-10-13 16:38 UTC · v1

Abstract

Deep learning has enabled substantial advances in oncology, including cancer detection and diagnosis, medical image analysis, tumor characterization, treatment planning, response assessment, and outcome prediction. However, conventional data-driven models often require large annotated datasets, exhibit limited generalization across heterogeneous clinical settings, and lack explicit mechanisms for incorporating the physical, physiological, and biological principles underlying cancer development and treatment. Physics-informed deep learning (PIDL) integrates governing physical laws, mechanistic models, physiological constraints, and domain knowledge into deep learning frameworks, providing a principled approach for learning from sparse, noisy, and heterogeneous oncological data. This review presents a task-oriented synthesis of PIDL methods across oncology, encompassing neural networks, Kolmogorov-Arnold networks, convolutional and vision architectures, neural operators, generative models, and hybrid physics-data-driven frameworks. Their applications are examined across cancer detection and diagnosis, image reconstruction and analysis, tumor characterization, quantitative imaging, tumor progression, treatment response, radiation therapy, treatment planning, and multimodal clinical modeling. Based on the synthesized methodological and application-level evidence, we develop task-optimized PIDL workflows that align the clinical task with appropriate data representations, physical constraints, model architectures, and validation strategies. We further analyze key challenges, including physical-model fidelity, computational scalability, uncertainty quantification, domain generalization, standardized benchmarking, and clinical validation.

Comment
51 pages

Closest papers

Nearest neighbours by meaning across the whole index.

Early Prediction of Pathological Complete Response to Neoadjuvant Chemotherapy Using Temporal Deep Learning on DWI

cs.AI ·2026-08-18 ·Pablo García Marcos, Md. Tarequl Islam, Paula Puerta González, Guillermo Lorenzo, Héctor Gómez +3 more
similarity 0.72
Abstract

Early identification of non-responders to neoadjuvant chemotherapy (NACT) is crucial for timely treatment adaptation in breast cancer. However, many existing predictive models rely on multiparametric magnetic resonance imaging (MRI), late treatment time points, or extensive clinical data, which limits their applicability. This study proposes a deep learning framework for early prediction of pathological complete response (pCR) using only diffusion-weighted MRI (DW-MRI) acquired at baseline and after the first NACT cycle. This framework feeds cropped tumor-centered patches to an EfficientNet-based temporal model that directly learns tumor shape and local tissue characteristics without explicit radiomic feature engineering. The model, trained with 10-fold cross-validation, achieved an area under the receiver operating characteristic curve (AUC) of 0.90 for pCR prediction after one cycle, providing actionable information after a single treatment cycle while avoiding gadolinium administration and reducing dependence on heterogeneous clinical data. By focusing on the baseline-to-first-cycle window instead of later stages, the approach supports earlier escalation or de-escalation of NACT, and its exclusive reliance on DW-MRI facilitates protocol standardization, multi-centre deployment and privacy-preserving data sharing. These results demonstrate that DW-MRI-based deep learning on tumor-centered patches constitutes a minimally invasive, clinically deployable strategy for early pCR prediction, with direct implications for personalized treatment adaptation in neoadjuvant breast cancer therapy.

0.21

Data-Efficient and Interpretable Classification of Circulating Tumor Cell Phenotypes in Microfluidic Devices via Deep Learning

cs.LG ·2026-08-17 ·Serena Su, Yifan Wang, Senwei Liang
similarity 0.67
Abstract

Accurate classification of circulating tumor cell (CTC) phenotypes can provide valuable information for assessing metastatic potential. Label free microfluidic devices provide a hydrodynamic obstacle course that transforms subtle biophysical characteristics of CTCs, including size and deformability, into distinct kinematic trajectories. However, the highly nonlinear fluid structure interactions governing these trajectories make the inverse problem of inferring cellular phenotype from trajectory data analytically intractable. While deep neural networks (DNNs) have emerged as a powerful approach for addressing this inverse problem, their effectiveness is constrained by the limited availability of trajectory data and the lack of physical interpretability. To address these challenges, we propose an interpretable and data efficient DNN framework for trajectory based CTC classification. To mitigate the scarcity of data, we develop Subsequence (SubSeq), a targeted augmentation strategy that randomly extracts informative local trajectory segments during training to promote learning from localized patterns. We further apply Gradient Weighted Class Activation Mapping to identify the trajectory features and physical regions of the microfluidic device that drive model predictions. Experimental results demonstrate that SubSeq improves classification accuracy over the evaluated baseline and augmentation methods. Furthermore, interpretability analysis suggests that localized trajectory segments contain substantial biophysical information relevant to accurate classification. This provides justification for SubSeq and also highlights the redundancy of full-length trajectories. More broadly, the proposed framework views microfluidic geometries as physical encoders of cellular mechanical properties, providing mechanistic insights that may inform the future design of diagnostic devices.

0.28

Energy-Mamba: A Physics-Constrained State-Space Model for Medical Image Classification

eess.IV ·2026-08-20 ·Mohamed Mabrok, Yalda Zafari, Essam A. Rashed
published similarity 0.65
Abstract · This paper was accepted to the MICCAI 2026 workshop MLMI

State-Space Models (SSMs), particularly Mamba, offer linear-time complexity for long-range dependencies, making them attractive for medical imaging with limited annotated data. However, adapting these sequential models to 2D images through unconstrained state evolution causes representational drift, the dynamic hidden state progressively loses fidelity to local image features. We introduce Energy-Mamba, integrating SSM dynamics with physics-informed constraints via a learnable potential energy function that quantifies compatibility between evolving states and static local features. Our Energy-Mamba Block introduces a gradient-based forcing term, computed dynamically via automatic differentiation, that pulls states toward low-energy configurations maintaining local visual fidelity. This formulation mirrors Hamiltonian dynamics: kinetic energy (SSM scan) plus potential energy (our constraint function) govern state trajectories. This architectural prior enables learning implicit constraints for robust, faithful representations, crucial in medical imaging where fine-grained local detail drives accurate diagnosis. Evaluated on four datasets (retinal OCT, chest X-ray, microscopy, abdominal CT), Energy-Mamba achieves state-of-the-art classification performance with significantly fewer parameters, demonstrating that physics-informed grounding can enhance both efficiency and representational quality in medical vision tasks.

0.24

Dose-PlanNet: Physics Based Radiotherapy Dose Prediction with Deep Learning

cs.CV physics.med-phcs.LG ·2026-08-27 ·Ankit Bhattacharjee, Sougata Maity, Santam Chakraborty, Indranil Mallick
code/data similarity 0.65
Abstract · The paper consists of 22 pages, 4 figures, 6 tables. The end-to-end pipeline of Dose-PlanNet will soon be made available on the GitHub repos…

Automating prostate radiotherapy treatment planning is dosimetrically complex, particularly for extreme hypofractionated regimens. In this study, we introduce Dose-PlanNet, a physics-guided 3D deep learning architecture designed to predict dose distributions. This model's performance was evaluated on a cohort of patients treated in a prospective trial where two different dose fractionation regimens were employed. Dose-PlanNet achieved comparable target coverage ($D_{95}$), though statistical analysis revealed a marginal reduction in target homogeneity ($p<0.001$) offset. However the model achieved statistically significant improvements in high-dose organ-at-risk sparing ($p<0.001$). When evaluated against strict Prospective Randomized protocol volumetric constraints, automated plans met prespecified clinical acceptance criteria in $11$ out of $14$ Moderate Hypofraction Arm plans and $9$ out of $12$ Stereotactic Body Radiation Therapy Arm plans. This pipeline demonstrates that physics-informed deep learning can accelerate radiotherapy workflows while safely maintaining the stringent dosimetric quality required for high-precision clinical deployment.

0.36

Heterogeneity-Aware Deep Learning for Tumour Classification from Multiparametric MRI

cs.CV ·2026-08-18 ·Yue Xia, Euijoon Ahn, Tian Xia, Yuan Yuan, Michael Fulham +1 more
similarity 0.64
Abstract

Intra-tumoural heterogeneity (ITH) reflects spatial variation in tumour biology and is an important determinant of tumour behaviour, prognosis, and treatment response. Radiomics and deep learning have shown promise for tumour classification from multiparametric MRI (mp-MRI), but radiomics relies on handcrafted features, while most deep learning methods use whole-tumour representations or manually defined sub-regions, limiting scalable modelling of tumour heterogeneity. We propose a Heterogeneity-Aware Deep Learning Classification (HA-DLC) framework that explicitly models imaging-derived tumour sub-regions for lesion-type diagnosis and molecular-status prediction. HA-DLC consists of: (1) a Heterogeneous Sub-region Generation (HSG) module that produces initial pseudo-labelled sub-regions via unsupervised clustering, followed by Cross-Patient Sub-region Alignment (CPSA), which maps cluster-derived regions to a shared label space using soft assignments; and (2) a Dual-Stream Feature Extraction (DSFE) module that integrates local heterogeneity-aware features with global tumour representations. Given the initial clustering masks, CPSA, segmentation, feature extraction, and classification are jointly optimized end-to-end using soft-target segmentation and classification objectives. We evaluate HA-DLC on the LLD-MMRI2023 liver lesion dataset and the RSNA-ASNR-MICCAI 2021 Radiogenomic Brain Tumour dataset. HA-DLC consistently outperforms state-of-the-art radiomics and deep learning baselines, demonstrating the value of cross-patient sub-region alignment and dual-stream heterogeneity modelling for tumour classification from mp-MRI.

0.26

Lesion-Aware Adaptive Fourier Neural Operator for CT-to-PSMA PET Synthesis in Prostate Cancer

cs.CV physics.med-ph ·2026-08-11 ·Rashmi Bhaskara, Waleed M. Almutairi, Matthew Gopaulchan, Maram Musaad Alqurashi, Francis Asamoah +3 more
similarity 0.64
Abstract

Deep learning models that synthesize PET from CT or MRI can reduce patient dose and scanner demand, but are typically optimized with global losses such as L1 or mean squared error (MSE) that treat all voxels similarly. In whole-body PSMA-PET, tumor voxels occupy only a small fraction of the volume, yet carry the clinically relevant activity signal; as a result, models can achieve high structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR) while still underestimating lesion activity or failing to preserve tumor-specific structure. Radiomics provides biologically meaningful descriptors of tumor intensity and texture, but direct radiomics conditioning is time-consuming because it requires feature extraction from delineated lesion regions. We propose LAFNO, a Lesion-Aware Adaptive Fourier Neural Operator for CT-to-PSMA-PET synthesis that replaces high-dimensional radiomics conditioning with two efficient CT-derived proxy channels. Motivated by radiomics analysis of PSMA-avid tumor core and peritumoral regions, LAFNO uses a contrast proxy for local density variation and a disorder proxy for local texture heterogeneity, both injected into the model bottleneck. LAFNO combines whole-volume reconstruction with lesion-level total lesion activity (TLA), tumor-core contrast, and peritumoral supervision. We evaluated LAFNO against four baseline architectures on the TCIA PSMA-PET-CT-Lesions dataset. LAFNO remained competitive on whole-volume image quality, achieving SSIM of 0.960 and 0.938 for 18F- and 68Ga-PSMA, respectively, while reducing per-patient TLA error to 48.3% and 64.0% for 18F- and 68Ga-PSMA, respectively, and achieving the highest tumor-core radiomics reproducibility across all feature classes for both tracers. Peritumoral reproducibility remained tracer-dependent, indicating that biological fidelity in synthetic PSMA-PET remains challenging.

0.04

Predicting Subsurface Abnormalities Growth using Physics-Informed Neural Networks

cs.LG ·2026-09-01 ·Mehrdad Shafiei Dizaji, Hoda Azari
similarity 0.64
Abstract · 30, 20

The research explores the pioneering integration of Physics-Informed Neural Networks (PINNs) into the domain of Ground-Penetrating Radar (GPR) data prediction. This research presents a detailed development framework for a specialized PINN model, proficient at interpreting and forecasting GPR data, much like how medical imaging models predict tumor behavior. By harnessing the synergy between deep learning algorithms and the physical laws governing subsurface structures or in medical terms, human tissues the model effectively embeds the physics of electromagnetic wave propagation into its architecture. This ensures that predictions not only align with fundamental physical principles but also mirror the precision needed in medical diagnostics for detecting and monitoring tumors. The suggested deep learning structure comprises three components: a CNN, a spatial feature channel attention (SFCA) mechanism, and ConvLSTM, along with temporal feature frame attention (TFFA) modules. The attention mechanism computes channel attention and temporal attention weights using self-adaptation, thereby fine tuning the visual and temporal feature responses to extract the most pertinent and significant visual and temporal features. By integrating physics directly into the neural network, our model has shown enhanced accuracy in forecasting GPR data. This improvement is vital for conducting effective assessments of bridge deck conditions and other evaluations related to civil infrastructure. The use of Physics Informed Neural Networks (PINNs) has demonstrated the potential to transform the field of Non-Destructive Evaluation (NDE) by enhancing the precision of infrastructure deterioration predictions. Moreover, it offers a deeper insight into the fundamental mechanisms of deterioration, viewed through the prism of physics-based models.

0.20

Physics-Informed Hemodynamic Modeling for Data-Free Prediction and Sparse-Data Assimilation

eess.IV cs.AI ·2026-09-16 ·Xi Chen, Jianchuan Yang, Hongde Li, Guangxin He, Qiuyu Ye +3 more
similarity 0.62
Abstract

Clinical decision-making for coronary intervention relies mainly on angiography and fractional flow reserve (FFR). However, angiography is two-dimensional and lacks depth information for 3D lesion characterization, while FFR provides only a single functional index, offering limited hemodynamic insight. Among existing methods, numerical analysis is computationally expensive, whereas learning-based approaches require extensive supervision and often lack physical consistency. To address these limitations, we propose physics-informed hemodynamic modeling, an integrated deep learning framework for 3D coronary blood flow analysis from dual-view angiography. First, an attention-enhanced CNN reconstructs coronary geometry from angiography. The resulting point clouds are then mapped to a reference domain and Fourier-encoded for joint representation. A decoupled network separately predicts velocity and pressure fields, with embedded physical priors enabling efficient transfer across physiological conditions. Across 32 clinical patients evaluated under four flow conditions, the trans-stenotic pressure-drop mean absolute percentage error was 2.02%, while the velocity and pressure relative-L2 errors were 0.054 and 0.023, respectively. Validation against hospital-measured FFR further achieved 93.8% diagnostic accuracy (30/32; exact 95% CI, 79.2%-99.2%). The framework also supports illustrative revascularization comparisons and sparse-data assimilation, with the full angiography-to-hemodynamics pipeline completed within 20 minutes per patient.

0.11