Galib Ahmed, Istiak Ahmed, Aritra Islam Saswato, Asib Mostakim Fony, Kazi Shahriar Sanjid, Md. Tanzim Hossain, Md. Anwarul Islam, Md. Nishan Khan, Md. Misbah Khan, Labiba Faiza Karim, Jobaer Rahman, S M Hasibul Hoque, Rahnuma Shahrin Rista, Kamruzzaman Rumman, Md Arifur Rahman, Syed Md. Akram Hussain, Mohammad Ashrafuzzaman Khan, M. Monir Uddin

eess.IV cs.CV ·submitted 2026-09-11 11:13 UTC · v2

Abstract

We developed DAMM-Net++, a 2.5D architecture for thoracic OAR and target volume segmentation that addresses three persistent challenges in radiotherapy auto-contouring: inter-slice surface incoherence, systematic failure on small low-contrast targets, and the absence of per-case reliability signals. The central component is an anatomy-change-aware bidirectional selective state-space memory that models through-plane anatomical change and selectively propagates context along the axial slice sequence. A boundary-aware decoder sharpens near-surface predictions, and an uncertainty head provides calibrated per-voxel confidence for clinical triage. We evaluated 2,146 patients across four centers, an independent external cohort of 112 patients, and a multicenter reader study involving 17 radiation oncologists on 305 cases. The model achieves a mean Dice of 0.955 and HD95 of 3.78 mm, with the largest gains on low-contrast organs-at-risk (OARs) and target volumes where through-plane context is most critical. The uncertainty head is well-calibrated and supports case-level triage. In the reader study, AI assistance reduced contouring time by 75-80% across experience levels and raised junior-reader IoU from 0.861 to 0.925, matching the unedited model. External validation showed a modest internal-to-external drop (< 5%) with calibrated uncertainty transferring without recalibration. The complete deployment pipeline from DICOM ingestion to TPS-compatible RTSTRUCT export has been integrated into the clinical workflow at a partner hospital, where it is used to assist with contouring. These results suggest that anatomically motivated inter-slice memory, paired with uncertainty-guided review, offers a clinically viable path for thoracic auto-contouring.

Closest papers

Nearest neighbours by meaning across the whole index.

Personalising Deformable Image Registration with Clinical Context and Deformation History for Adaptive Radiotherapy

eess.IV cs.AI ·2026-10-13 ·Caiwen Jiang, Songlin Zhao, Yuzhen Ding, Jia Mi, Samir H. Patel +21 more
benchmark similarity 0.73
Abstract · 27 pages, 7 figures and 6 tables. The submission includes Supplementary Information

Adaptive radiotherapy must account for anatomical changes during treatment, but doing so depends on reliably mapping targets, organs at risk and dose across serial images. Existing registration methods treat each image pair independently, without using radiotherapy-specific context or the patient's preceding anatomical trajectory. We developed Clinical-context-Aware and Patient-adaptive Deformable Image Registration (CAP-DIR), integrating source contours, dose, clinical text and prior-registration features. We evaluated 16,361 CT examinations from 3,473 patients across four institutional cohorts and five public benchmarks. CAP-DIR increased internal-test organ-at-risk-region normalized cross-correlation from 84.76% to 96.92% relative to the strongest learning-based comparator, with low deformation folding, and remained superior across seven external cohorts. In a blinded review of 20 longitudinal cases, clinically acceptable contours increased from 45.0% to 82.5% for clinical target volumes and from 22.5% to 62.5% for organs at risk, while estimated editing time decreased. In a controlled benchmark, CAP-DIR reduced global dose-mapping error by 34.5% relative to the strongest comparator. These findings show that clinically informed, longitudinal registration can improve contour usability and dose mapping for adaptive radiotherapy.

0.37

From Vision to Context: A Review of Prompt-Driven Target Volume Segmentation in Radiotherapy

eess.IV ·2026-11-04 ·Bakpen Kombat, Guus Grimbergen, Maarten L. Terpstra, Gert J. Meijer, Lois +1 more
survey similarity 0.71
Abstract · Submitted to Computerized Medical Imaging and Graphics

Accurate target volume (TV) segmentation is essential for radiotherapy (RT) planning but remains time-consuming. Moreover, the final contour depends on the expertise of the radiation oncologist. Although deep learning has improved medical image segmentation, image-only models cannot encode the clinical reasoning that governs TV delineation, particularly for the clinical target volume (CTV), where boundaries are defined by clinical knowledge rather than imaging features alone. Prompt-driven segmentation has recently emerged as a strategy to address this limitation. This work aims to review these approaches for RT TV segmentation with four objectives: (1) compare the different prompting techniques used; (2) compare their performance against image-only baselines; (3) assess how they are evaluated against standard metrics, including the Dice similarity coefficient (DSC), 95th Hausdorff distance, sensitivity, precision, and clinical assessment; and (4) identify the gaps needed for clinical translation. We systematically searched PubMed, Embase, and arXiv for studies incorporating geometric, clinical text, or interactive prompts into deep learning models for RT TV delineation. Thirteen studies met the inclusion criteria, spanning head and neck, breast, prostate, lung, cervix, and rectal cancers. Seven studies used clinical text prompting, four used geometric prompting, and two used interactive prompting; three combined modalities. Reported DSC ranged from 0.67 to 0.93, compared to 0.65 to 0.91 for image-only baselines. None reported sensitivity or precision. Clinical text prompting appears well suited to CTV delineation. Evidence remains limited, and standardized prompt engineering and clinical validation are needed before these approaches can be translated into routine RT practice.

0.23

Image-Conditioned Diffusion Models for Quality Assurance of Organ-at-Risk Segmentations in Radiotherapy

cs.CV ·2026-08-24 ·Clea Dronne, Catharine H Clark, Xavier Loizeau, Elizabeth Miles, Peter Hoskin +1 more
hot direction similarity 0.68
Abstract · Submitted to the MICCAI 2026 UNSURE Workshop

Accurate organ-at-risk segmentation is essential for radiotherapy planning, but reviewing segmentations is time-consuming and subjective. We investigate normative modelling for segmentation error detection in head-and-neck CT, comparing a VAE framework with an image-conditioned segmentation diffusion model. Models were evaluated on RADCURE brainstem and spinal cord segmentations using simulated boundary and width perturbations. Error detection was assessed using the Dice similarity coefficient and the Distance to Agreement (DTA) between the input and reconstructed segmentations. While both models detected some simulated errors, regional DTA showed that the diffusion model localised subtle boundary errors more consistently. These results support image-conditioned diffusion reconstruction as a promising framework for localised, anatomy-aware segmentation QA.

0.36

Next-Generation Segmentation in Radiotherapy: A Narrative Review from Atlas-Based Methods to Agentic Vision-Language Models

eess.IV physics.med-ph ·2026-11-09 ·Josef A. Buchner, Richard Osuala, Ayhan Can Erdur, Melissa C. Olufs, Stephanie E. Combs +1 more
similarity 0.67
Abstract

Precise segmentation of target volumes and organs at risk is an essential prerequisite for modern, high-precision radiation therapy. However, this task has traditionally been time-consuming and subject to high interobserver variability. Motivated by these limitations, more advanced and novel approaches to automating this task have been developed over the past two decades. This narrative review highlights representative milestones, with a focus on the most recent developments. These approaches include atlas-based label propagation, convolutional architectures, promptable foundation models, and, most recently, vision-language models (VLMs), which integrate clinical text with volumetric segmentation. Each methodological generation has addressed limitations of its predecessor while introducing new ones. A substantial gap remains between research progress and clinical deployment, as routine workflows continue to be dominated by atlas-based and narrow task-specific deep-learning tools, which remain strong baselines in geometric overlap metrics but are highly rigid in terms of application, versatility, portability, and interpretability. As contouring systems further grow in complexity, conventional geometric overlap metrics become insufficient, motivating evaluation paradigms that incorporate surface-based, dosimetric, and prompt-adherence assessment. Emerging agentic architectures that combine large language models, retrieval-augmented generation, and vision-language segmentation modules are leading towards more flexible, guideline-aware, interactive contouring workflows. These systems could automate flexible and interpretable knowledge-based contouring and actively support the clinical reasoning underlying target volume definition.

0.10

Improving Clinical Target Volume Segmentation Accuracy using Anatomical Priors and Active Learning for the AGITG TOPGEAR Clinical Trial

cs.CV physics.med-ph ·2026-09-02 ·Phillip Chlap, Mark Lee, Trevor Leong, Matthew Field, Jason Dowling +9 more
similarity 0.66
Abstract

Training deep learning-based medical image segmentation models is challenging with limited curated datasets. For AGITG TOPGEAR, a gastric cancer trial, the Clinical Target Volume (CTV) is complex and defined by multiple anatomical landmarks, making upfront training data preparation difficult for an automated contour QA segmentation model. We investigate anatomical priors, derived from surrounding organ segmentations, to provide spatial context and improve TOPGEAR CTV segmentation accuracy. We also evaluate active learning, iteratively expanding the training dataset by selecting cases expected to improve performance. One hundred TOPGEAR CT scans were retrospectively analyzed. An initial set of 10 expert-contoured cases was used to train an nnU-Net model. TotalSegmentator generated a voxel-wise anatomical prior map from surrounding structures as an additional input channel. Active learning was simulated over four iterations, selecting cases by model uncertainty and segmentation performance. All models used five-fold cross-validation for an ensemble uncertainty measure. Evaluation used a hold-out testing set of 50 cases. The anatomical prior improved CTV segmentation accuracy, increasing mean Dice Similarity Coefficient (DSC) from 0.84 to 0.86. Active learning similarly improved performance to 0.86, with greatest benefit in the final round. Combining the anatomical prior with active learning achieved the highest accuracy, with a DSC of 0.87. Model uncertainty correlated with DSC, supporting its use in identifying suboptimal predictions and guiding active learning. Anatomical priors and active learning each improved CTV segmentation accuracy and generalizability, with their combination achieving the best performance, supporting integration into segmentation model development for automated contour QA in radiotherapy clinical trials.

0.16

A Neighborhood Attention Transformer Network for Enhanced 3D Segmentation of the Left Anterior Descending Artery

cs.CV cs.AI ·2026-08-12 ·Rafi Ibn Sultan, Chengyin Li, Yiannos Demetriou, Ahmed I. Ghanem, Joshua P. Kim +4 more
published similarity 0.65
Abstract · Acceteed by Medical Physics 2026

Background: Accurate segmentation of the Left Anterior Descending (LAD) artery in 3D free-breathing, non-contrast CT is critical for cardiac dose sparing in thoracic radiotherapy. The LAD is extremely small, has poor soft-tissue contrast, and varies substantially across patients; even manual contours show limited inter-observer agreement, underscoring the ambiguity of the vessel boundaries. Purpose: To develop a transformer-based framework that improves LAD delineation in low-contrast, imbalanced CT through local-global context modeling and uncertainty-guided optimization. Methods: We propose NA-UNETR, a 3D transformer-based segmentation model whose Neighborhood Attention (NA) and Dilated NA (DiNA) blocks jointly capture fine structural detail and long-range context. Given the scarcity of annotated LAD data, the model is pretrained on 1,000 CTA volumes of general coronary anatomy and fine-tuned with LoRA-based parameter-efficient adaptation on 20 free-breathing institutional CT scans. A composite Dice-Focal and Hausdorff loss, dynamically balanced via homoscedastic uncertainty, improves overlap and boundary accuracy. Results: NA-UNETR reached 45.64% Dice, 38.16 mm HD95, and 10.01 mm ASD, improving Dice by 3.10 percentage points over nnU-Net and reducing HD95 by 2.96 mm relative to Swin UNETR, with the strongest boundary accuracy among all models and improved centerline stability. On ImageCAS it achieved 79.49% Dice, 8.89 mm HD95, and 1.02 mm ASD. Ablations confirmed that residual blocks, variable kernels, and uncertainty-weighted loss each contributed. Conclusions: NA-UNETR balances local precision and global context for thin, low-contrast LAD structures, offering a computationally efficient framework for substructure-level cardiac segmentation in radiotherapy planning.

0.52

Uncertainty-Aware Multimodal Deep Learning for Prediction of Radiation-Induced Xerostomia in Head and Neck Cancer

eess.IV ·2026-11-19 ·Jin Yang, Tian Liu, Jose Penagaricano, Jing Wang, Erin L. Moshier +3 more
similarity 0.64
Abstract · 24 pages, 4 figures

To develop and evaluate an uncertainty-aware multimodal learning framework for predicting radiation-induced xerostomia in patients receiving head-and-neck cancer radiotherapy. We developed a Bidirectional Attention-enhanced Diffusion Transformer (BA-DiT) that combines self-supervised multimodal representation learning with supervised Bayesian fine-tuning. The model integrates pretreatment CT images and three-dimensional dose distributions, focusing on bilateral parotid glands while incorporating surrounding anatomical and dosimetric information. During pretraining, bidirectional cross-attention integrates anatomical and dosimetric features, while a latent Diffusion Transformer learns joint representations through diffusion-based learning, feature reconstruction, and contrastive alignment. Supervised fine-tuning employs a Bayesian classifier to predict individualized xerostomia risk and quantify predictive uncertainty, with a learnable label-transition model accounting for potential toxicity label uncertainty. BA-DiT was developed using four independent cohorts (Moffitt, Emory, MSHS, and TCIA) and evaluated against baseline and ablation models. Evaluation included predictive performance, calibration, uncertainty quantification, decision curve analysis, and patient-level case studies. In independent MSHS and Emory cohorts, BA-DiT achieved AUCs of 0.83 and 0.80, respectively, outperforming baseline models. Predictive uncertainty peaked near the decision boundary, with aleatoric uncertainty being the predominant component. Uncertainty-based selective prediction generally improved net benefit among retained patients, with greater gains at lower prediction coverage. BA-DiT enables individualized xerostomia risk prediction while providing complementary uncertainty estimates, potentially supporting informed clinical decision-making and personalized toxicity management.

0.14

Impact of Pretraining Length, Model Size, and Annotation Budget on Downstream Clinical Tasks of Foundation Models in Radiotherapy

cs.CV ·2026-11-17 ·Alejandro Cortina Uribe, Sidsel Højklint Poulsen, Ivan Richter Vogelius, Jens Petersen
code/data similarity 0.64
Abstract · 9 pages, 5 figures, 2 tables. Supplementary Material included

Cone-beam CT (CBCT) scans acquired during radiotherapy capture changes such as tumor shrinkage and radiation-induced tissue changes, offering great potential for foundation models that help monitor individual treatment responses. However, to our knowledge, no large-scale pretrained models for radiotherapy CBCT exist, and evaluating modeling choices is difficult since downstream tasks are not known in advance. We examine how pretraining length, model size, and finetuning strategy relate to downstream clinical performance, and how metrics tracked during pretraining correlate with it. We pretrain vision transformer encoders with masked image modeling on about 150,000 raw 3D radiotherapy CBCT scans, tracking representation quality via validation loss, effective rank, and linear probing. Downstream tasks are classification of feeding tube presence ($n=51,135$ CBCTs, $1,562$ patients) and clinical characteristics (T-, N-stage, sex, age, tumor site; $n=1,278$ patients) in head and neck cancer. We compare low-rank adaptation (LoRA) and full finetuning against no pretraining, varying annotated dataset size. Pretext validation loss was the most consistent predictor of downstream performance; effective rank and linear probing were also associated, but not consistently across model sizes and finetuning methods. LoRA performed comparably to full finetuning while training only 0.5-2.5% of the parameters. Fully finetuned models consistently outperformed models without pretraining across all sizes, with AUROC 0.91-0.97 vs. 0.58-0.85 for feeding tube classification and 0.99-1.00 vs. 0.71-0.97 for sex classification. Model size had only a small, inconsistent effect, suggesting smaller models suffice at lower computational cost. Code and pretrained models (non-commercial license): https://github.com/alexCortinaU/RT-CBCT_SSL