CS Paper Radar

Image-Conditioned Diffusion Models for Quality Assurance of Organ-at-Risk Segmentations in Radiotherapy

Clea Dronne, Catharine H Clark, Xavier Loizeau, Elizabeth Miles, Peter Hoskin, Jamie R McClelland

cs.CV ·submitted 2026-08-24 16:07 UTC · v1
hot direction

Abstract

Accurate organ-at-risk segmentation is essential for radiotherapy planning, but reviewing segmentations is time-consuming and subjective. We investigate normative modelling for segmentation error detection in head-and-neck CT, comparing a VAE framework with an image-conditioned segmentation diffusion model. Models were evaluated on RADCURE brainstem and spinal cord segmentations using simulated boundary and width perturbations. Error detection was assessed using the Dice similarity coefficient and the Distance to Agreement (DTA) between the input and reconstructed segmentations. While both models detected some simulated errors, regional DTA showed that the diffusion model localised subtle boundary errors more consistently. These results support image-conditioned diffusion reconstruction as a promising framework for localised, anatomy-aware segmentation QA.

Comment
Submitted to the MICCAI 2026 UNSURE Workshop

Closest papers

Nearest neighbours by meaning across the whole index.

Uncertainty as a Proxy for Semantic Correctness in Diffusion-Based Medical Image Synthesis

cs.CV cs.AI ·2026-10-02 ·Yuxuan Ou, Konstantinos Kamnitsas, OxAAA Study, AICT Consortium, Regent Lee +1 more
similarity 0.68
Abstract

Diffusion models can synthesise contrast-enhanced CT (CECT) from non-contrast CT (NCCT), avoiding contrast administration and its environmental and patient-access costs. However, visually realistic images are not necessarily anatomically correct, and the pixel-intensity and feature-space similarity metrics used to assess generation quality do not directly measure anatomical correctness. In this work, we investigate whether uncertainty can serve as a proxy for semantic correctness in diffusion-based medical image synthesis. We study NCCT-to-CECT synthesis using AortaDiff, a multitask diffusion framework that jointly generates CECT images and lumen segmentations. The segmentation output provides an explicit representation of the generated vascular anatomy, enabling segmentation-derived errors to be used as a quantitative measure of generation correctness. Six methods spanning weight (Ensemble, HyperDiff, BayesDiff), architecture-perturbation (MCDropout), generative-stochasticity (RDS) and input-perturbation (TTA) uncertainty are compared at the pixel, region and image levels, and for detection of clinically relevant out-of-distribution (OOD) cases. Uncertainty proves informative at all three spatial scales, remains informative on an external multi-centre dataset under distribution shift, and supports OOD detection. MCDropout stands out among the six: it ranks among the leading methods at every scale, generalizes well on the external dataset, and can be enabled at inference on any model already trained with dropout, so reliable uncertainty comes at no extra training cost. Uncertainty reliably flags severe failures but discriminates poorly among already high-quality images. These findings support uncertainty as a practical and computationally economical signal for quality filtering, reliability assessment and OOD detection in NCCT-to CECT synthesis.

0.14

Spatially and Compositionally Controlled Multimodal Glioblastoma MRI Synthesis with Latent Diffusion

cs.CV ·2026-11-04 ·Steven Glass, Max Van Puyvelde, Marija Pizurica, Mia Meyer, Olivier Gevaert +1 more
similarity 0.68
Abstract

Glioblastoma exhibits substantial heterogeneity in tumour morphology and composition across MRI modalities, often making available clinical datasets highly unbalanced in terms of patient pathologies. We propose a two-stage latent diffusion model (LDM) framework for the generation of explicitly controllable 2D glioblastoma MRI scans. First, a segmentation LDM generates tumour maps conditioned on location, spatial extent, axial position, and subregion composition. Second, a modality-conditioned LDM with ControlNet generates T1, T1Gd, T2, and FLAIR images adhering to the requested segmentation. On a held-out test set, generated segmentations achieved a mean centroid error of 0.842 pixels and a subregion proportion error of 0.795 percentage points. ControlNet improved Fréchet inception distance (FID) across all four modalities, reducing pooled FID from 42.59 to 36.12. An expert reader study yielded mean quality ratings of 6.60 for real images, 6.83 for ControlNet-generated images, and 6.77 for fully synthetic images.

0.20

Anatomy-Change-Aware Bidirectional Selective State-Space Memory for Clinically Deployed Thoracic Radiotherapy Auto-Contouring

eess.IV cs.CV ·2026-09-11 ·Galib Ahmed, Istiak Ahmed, Aritra Islam Saswato, Asib Mostakim Fony, Kazi Shahriar Sanjid +13 more
similarity 0.68
Abstract

We developed DAMM-Net++, a 2.5D architecture for thoracic OAR and target volume segmentation that addresses three persistent challenges in radiotherapy auto-contouring: inter-slice surface incoherence, systematic failure on small low-contrast targets, and the absence of per-case reliability signals. The central component is an anatomy-change-aware bidirectional selective state-space memory that models through-plane anatomical change and selectively propagates context along the axial slice sequence. A boundary-aware decoder sharpens near-surface predictions, and an uncertainty head provides calibrated per-voxel confidence for clinical triage. We evaluated 2,146 patients across four centers, an independent external cohort of 112 patients, and a multicenter reader study involving 17 radiation oncologists on 305 cases. The model achieves a mean Dice of 0.955 and HD95 of 3.78 mm, with the largest gains on low-contrast organs-at-risk (OARs) and target volumes where through-plane context is most critical. The uncertainty head is well-calibrated and supports case-level triage. In the reader study, AI assistance reduced contouring time by 75-80% across experience levels and raised junior-reader IoU from 0.861 to 0.925, matching the unedited model. External validation showed a modest internal-to-external drop (< 5%) with calibrated uncertainty transferring without recalibration. The complete deployment pipeline from DICOM ingestion to TPS-compatible RTSTRUCT export has been integrated into the clinical workflow at a partner hospital, where it is used to assist with contouring. These results suggest that anatomically motivated inter-slice memory, paired with uncertainty-guided review, offers a clinically viable path for thoracic auto-contouring.

0.20

Unsupervised Anatomical Feature Learning via Diffusion Models: Enhanced Medical Image Segmentation with Denoising Diffusion Probabilistic Models

cs.CV cs.AIcs.LG ·2026-08-26 ·Akshat G, Divyansh Gupta, Shaleen Bhatnagar, Shilpa Ankalaki, Tusar Kanti Mishra
similarity 0.65
Abstract · 15 pages, 5 figures. Submitted for peer review

Acquiring pixel-level annotations for medical image segmentation is a severe bottleneck. Traditional U-Net architectures, while effective, learn local texture patterns and lack awareness of global anatomical structures, leading to boundary delineation failures in low-data regimes. This research paper proposes utilizing unsupervised Denoising Diffusion Probabilistic Models (DDPMs) to extract anatomical features. We train a DDPM on 21 unlabeled abdominal CT scans to learn structural representations, transferring the encoder weights to a downstream segmentation task evaluated on the BTCV multi-organ dataset. Diffusion pretraining significantly improved liver segmentation: Dice increased from $0.75\pm0.36$ to $0.93\pm0.16$ ($p < 5.33\times10^{-26}$, 0.529 Cohen's d), Average Surface Distance (ASD) decreased by 66%, and 95th-percentile Hausdorff Distance (HD95) reduced by 45%. For kidney segmentation, Dice improved from $0.90\pm0.19$ to $0.95\pm0.10$ ($p < 4.01\times10^{-11}$). Multi-organ pooled performance showed a 68% variance reduction and a 74% improvement in boundary precision (Dice $0.95\pm0.07$). Crucially, frozen encoder models retained > 80% of fine-tuned performance without exposure to segmentation labels, proving the existence of learned anatomical priors. In low-data scenarios, diffusion-pretrained models maintained robust performance with only 50% (Dice: 0.92 liver, 0.94 kidney), 25%, and even 10% (Dice: 0.89 liver, 0.71 kidney) of labeled data. Using unlabeled images for diffusion-based pretraining successfully embeds robust anatomical features prior to human supervision, transforming U-Nets into anatomy-aware systems.

0.21

Anatomy-preserving unpaired cone-beam CT refinement for image-guided radiotherapy using pseudo-label guided diffusion

cs.CV ·2026-10-05 ·Qi Lai, Yutong He
code/data similarity 0.64
Abstract

Cone-beam computed tomography (CBCT) is widely used in image-guided radiotherapy, but scatter, beam hardening, noise, truncation, and other artifacts limit image quality and CT number accuracy. Paired CBCT and CT data are difficult to obtain clinically because of motion, anatomical changes, and acquisition mismatch. We present RefineCBCT, an unpaired CBCT refinement framework that uses pseudo-label guidance and short-step diffusion to reduce artifacts while preserving patient-specific anatomy. RefineCBCT was trained and evaluated on unpaired CBCT and planning CT data from public LUNG TCIA and PELVIC TCIA datasets and compared with representative GAN and diffusion based methods. On LUNG TCIA, it achieved the best results across all metrics, with MAE 19.411, RMSE 62.758, PSNR 30.845 dB, and SSIM 0.931. On PELVIC TCIA, it achieved the best MAE, PSNR, and SSIM, with values of 14.905, 36.671 dB, and 0.876. The refined images showed fewer streaking and shading artifacts, clearer anatomical boundaries, and improved soft tissue uniformity, with line profile and ROI analyses showing closer agreement with planning CT. These results suggest that RefineCBCT provides efficient and effective CBCT refinement under clinically realistic unpaired training conditions and may support more reliable CBCT use in image-guided radiotherapy workflows. Code is publicly available on GitHub, and the evaluated datasets are available from The Cancer Imaging Archive.

0.21

Volumetric Latent Diffusion for Brain Tumour Segmentation with Missing Modalities

eess.IV ·2026-11-05 ·Toan Nguyen Hai, Hung Nguyen Tuan, Ba Luong Son, Huynh Trinh Ngoc
similarity 0.64
Abstract

Brain tumour segmentation from magnetic resonance imaging normally assumes that all four imaging sequences are available, but in clinical practice one or more are frequently missing. Existing methods for incomplete inputs learn modality-invariant representations or distil from a full-modality teacher, and return a single deterministic mask. Gen- erative formulations instead model a distribution over plausible masks, but the cost of sampling at full resolution has largely confined them to two dimensions. This paper proposes a three-dimensional conditional latent diffusion framework for whole-tumour segmentation from incom- plete multi-sequence MRI. Images and annotations are first compressed by two volumetric autoencoders, which makes diffusion over whole vol- umes affordable, and sequences are dropped at random during training so that a single model handles every combination of missing sequences. Because the model samples rather than predicts, repeated draws also yield a voxel-wise map of disagreement at no extra training cost. Evalu- ations on 2,601 studies from BraTS 2023 and 2024 show that the method reaches 0.955 Dice with all four sequences and 0.904 with FLAIR alone, and that it is the most accurate of the four methods compared in eight of the fifteen configurations. The disagreement between draws widens as sequences are withheld, giving a signal that accompanies the prediction rather than replacing it

0.21

What Matters is the Prompt: Prompt Sensitivity and Prompt Generation in Foundation Models for Lung Nodule Segmentation

eess.IV ·2026-08-17 ·Jorge F. Lazo, Xixi Liu, Andreas Hallqvist, Mikael Johansson, Åse Johnsson +3 more
similarity 0.63
Abstract

Lung nodule segmentation in computed tomography is essential for extracting clinically relevant information for lung cancer assessment and treatment planning. Foundation models have shown notable segmentation capabilities, but state-of-the-art approaches often depend on input prompts, such as points or boxes, making their performance sensitive to prompt quality and placement. Understanding the limitations and constraints of prompt-based foundation models is therefore essential for designing reliable medical image segmentation solutions. In this work, we investigate how prompt quality affects foundation models performance for lung nodule segmentation. We further propose a synthetic prompt-generation model to test if the dependence on manually provided prompts can be mitigated by generating synthetic prompts that can also improve segmentation performance. Perturbation experiments show that bounding box prompts generally outperform point prompts, while latest specialized medical imaging models achieve better performance than general purpose ones. The proposed approach obtains a Dice coefficient of 0.85, suggesting that synthetic prompt generation as a promising strategy for lung nodule segmentation with foundation models.

0.26

Personalising Deformable Image Registration with Clinical Context and Deformation History for Adaptive Radiotherapy

eess.IV cs.AI ·2026-10-13 ·Caiwen Jiang, Songlin Zhao, Yuzhen Ding, Jia Mi, Samir H. Patel +21 more
benchmark similarity 0.62
Abstract · 27 pages, 7 figures and 6 tables. The submission includes Supplementary Information

Adaptive radiotherapy must account for anatomical changes during treatment, but doing so depends on reliably mapping targets, organs at risk and dose across serial images. Existing registration methods treat each image pair independently, without using radiotherapy-specific context or the patient's preceding anatomical trajectory. We developed Clinical-context-Aware and Patient-adaptive Deformable Image Registration (CAP-DIR), integrating source contours, dose, clinical text and prior-registration features. We evaluated 16,361 CT examinations from 3,473 patients across four institutional cohorts and five public benchmarks. CAP-DIR increased internal-test organ-at-risk-region normalized cross-correlation from 84.76% to 96.92% relative to the strongest learning-based comparator, with low deformation folding, and remained superior across seven external cohorts. In a blinded review of 20 longitudinal cases, clinically acceptable contours increased from 45.0% to 82.5% for clinical target volumes and from 22.5% to 62.5% for organs at risk, while estimated editing time decreased. In a controlled benchmark, CAP-DIR reduced global dose-mapping error by 34.5% relative to the strongest comparator. These findings show that clinically informed, longitudinal registration can improve contour usability and dose mapping for adaptive radiotherapy.

0.37