CS Paper Radar

Spatially and Compositionally Controlled Multimodal Glioblastoma MRI Synthesis with Latent Diffusion

Steven Glass, Max Van Puyvelde, Marija Pizurica, Mia Meyer, Olivier Gevaert, Willie Brink

cs.CV ·submitted 2026-11-04 14:10 UTC · v1

Abstract

Glioblastoma exhibits substantial heterogeneity in tumour morphology and composition across MRI modalities, often making available clinical datasets highly unbalanced in terms of patient pathologies. We propose a two-stage latent diffusion model (LDM) framework for the generation of explicitly controllable 2D glioblastoma MRI scans. First, a segmentation LDM generates tumour maps conditioned on location, spatial extent, axial position, and subregion composition. Second, a modality-conditioned LDM with ControlNet generates T1, T1Gd, T2, and FLAIR images adhering to the requested segmentation. On a held-out test set, generated segmentations achieved a mean centroid error of 0.842 pixels and a subregion proportion error of 0.795 percentage points. ControlNet improved Fréchet inception distance (FID) across all four modalities, reducing pooled FID from 42.59 to 36.12. An expert reader study yielded mean quality ratings of 6.60 for real images, 6.83 for ControlNet-generated images, and 6.77 for fully synthetic images.

Closest papers

Nearest neighbours by meaning across the whole index.

GliomaINK: A Tumor and Anatomy Conditioned Flow Matching Framework for 3D MRI Sequence Synthesis in Glioma Patients

eess.IV cs.CVq-bio.TO ·2026-10-16 ·Moinak Bhattacharya, Annie Singh, Mohammad Chaudhry, Prateek Prasanna, Gagandeep Singh
similarity 0.75
Abstract

Background: Incomplete multiparametric MR examinations limit glioma characterization and downstream AI tools. Generative models can synthesize missing MRI sequences, but anatomical structure and clinically relevant tumor features are challenging to preserve. We propose GliomaINK, an anatomy-guided conditional flow matching framework for cross-sequence 3D brain MRI synthesis. Methods: A 3D SwinUNETR predicted the conditional velocity field while an auxiliary topology-preserving loss encouraged structural consistency. The model was trained on 1,083 patients from the BraTS-AG dataset and independently tested on an in-house clinical cohort. Downstream tasks include image quality, tumor segmentation, IDH1 mutation-status prediction, and overall survival prediction. Two radiologists independently evaluated the anatomical fidelity, pathological representation, and overall image quality of the synthesized images. Results: GliomaINK exhibited the highest PSNR across all six MRI translation directions in both evaluation cohorts. In the BraTS-AG test set, the PSNR reached $25.64\pm0.55$ dB for the T2W-to-T1C synthesis, compared with $13.78\pm0.32$ dB for Pix2Pix and $18.90\pm0.53$ dB for SPADE. For downstream tumor segmentation, the method showed strong performance across tumor subregions with Dice scores reaching $0.928\pm0.014$ for edema, and $0.885\pm0.040$ for enhancing tumor. For the IDH1 mutation-status prediction, GliomaINK achieved the highest AUROC score in four of the six sequence configurations, reaching $0.827\pm0.088$. Conclusion: Anatomy-guided conditional flow matching enables high-fidelity cross-sequence glioma MRI synthesis demonstrating potential for preservation of clinically relevant information in synthesized MRI and improving downstream tasks.

0.18

Volumetric Latent Diffusion for Brain Tumour Segmentation with Missing Modalities

eess.IV ·2026-11-05 ·Toan Nguyen Hai, Hung Nguyen Tuan, Ba Luong Son, Huynh Trinh Ngoc
similarity 0.74
Abstract

Brain tumour segmentation from magnetic resonance imaging normally assumes that all four imaging sequences are available, but in clinical practice one or more are frequently missing. Existing methods for incomplete inputs learn modality-invariant representations or distil from a full-modality teacher, and return a single deterministic mask. Gen- erative formulations instead model a distribution over plausible masks, but the cost of sampling at full resolution has largely confined them to two dimensions. This paper proposes a three-dimensional conditional latent diffusion framework for whole-tumour segmentation from incom- plete multi-sequence MRI. Images and annotations are first compressed by two volumetric autoencoders, which makes diffusion over whole vol- umes affordable, and sequences are dropped at random during training so that a single model handles every combination of missing sequences. Because the model samples rather than predicts, repeated draws also yield a voxel-wise map of disagreement at no extra training cost. Evalu- ations on 2,601 studies from BraTS 2023 and 2024 show that the method reaches 0.955 Dice with all four sequences and 0.904 with FLAIR alone, and that it is the most accurate of the four methods compared in eight of the fifteen configurations. The disagreement between draws widens as sequences are withheld, giving a signal that accompanies the prediction rather than replacing it

0.21

CAPS: Clinically-Verifiable Anatomy-Prioritized Synthesis for Missing MRI Imputation in Brain Tumor Segmentation

eess.IV cs.CV ·2026-10-20 ·Cecilia Diana-Albelda, Arthur Longuefosse, Mario Rubén Paz Campos, Álvaro García-Martín, Jesus Bescos
similarity 0.72
Abstract · 20 pages, 6 figures, 8 tables. Cecilia Diana-Albelda and Arthur Longuefosse contributed equally

Multi-parametric MRI is the gold standard for neuro-oncology, yet acquiring complete 4-modality protocols may be unfeasible in real-world clinical practice. When handling missing modalities, existing automated systems force a critical compromise: robust segmenters operate as uninterpretable "black boxes" that bypass image generation, while standard synthesis models often produce blurry reconstructions lacking diagnostic reliability. To address this issue, we propose CAPS, a Clinically-Verifiable Anatomy-Prioritized Synthesis framework that reconciles computational precision with clinical transparency. Our multi-modal generative architecture is driven by a hybrid objective function (L_1 + L_AFP + L_DualDice) that explicitly enforces the preservation of deep anatomical features and strict topological boundaries, rather than relying solely on pixel-wise optimization. Evaluated comprehensively on the BraTS Adult Glioma dataset, the framework achieves superior synthesis fidelity across intensity-based metrics, and demonstrates robust downstream segmentation performance (82.38% mean Dice), successfully restoring verifiable visual context. Furthermore, the framework exhibits exceptional zero-shot cross-domain generalization, maintaining high structural fidelity across completely unseen Meningioma, Pediatric, and Sub-Saharan African cohorts without domain-specific adaptation. Finally, a blinded radiological assessment confirms that our anatomy-aware approach significantly enhances both perceived image quality and clinical utility, providing clinicians with the reliable visual evidence required to trust downstream automated workflows.

0.20

ME^2FDiff: Multiscale Expert Enhancing Feature Diffusion in Residual Network for Brain Tumor Segmentation

cs.CV ·2026-11-04 ·Afrida Rahman, Bijoy Kundu
similarity 0.71
Abstract

Automated segmentation of post-treatment glioma from MRI is essential for accurate diagnosis and treatment planning, yet remains difficult. Surgery and chemoradiotherapy cause structural changes in brain like resection cavities, edema, and fibrosis, that alter imaging appearance and mimic tumor recurrence. Contemporary segmentation architectures attain high accuracy with two limitations. First, the bottleneck originates from the deepest encoder stage, so one representation must serve sub-regions that differ widely in size and appearance. Second, they produce the segmentation in a single forward pass with no mechanism for refinement. We propose ME^2FDiff, a single-model architecture, addressing both. An attention-conditioned spectral diffusion block refines the bottleneck. It uses the image-conditioned latent diffusion process with two processes: a spatial pre-attention gate and a spectral fusion block whose timestep-adaptive bandpass filter selects the informative frequency band at each noise level. A multiscale expert-enhanced feature block fuses the intermediate encoder scales into the bottleneck through expert-selected shared tokens, guaranteeing balanced utilization without an auxiliary loss. On the BraTS 2024 post-treatment glioma dataset, ME^2FDiff achieves the best results on every tumor sub-region among all single-model baselines (91.23% Dice, 84.52% IOU, 2.13 mm HD95 on whole-tumor) and surpasses a three-expert ensemble on both overlap metrics at roughly one-third of its inference cost. Against recent state-of-the-art methods retrained under identical conditions, it maintains the strongest performance with the fewest parameters of any competing model. These findings demonstrate that a single, compact network can absorb the specialization, usually sought through ensembling or larger architectures.

0.23

Parameter-Efficient Multimodal Brain Tumor Segmentation With Stage-Wise Shared Adapters

cs.CV ·2026-10-13 ·Milad Rostamian, Mohammadreza Mohammadi, Ender Konukoglu, Mohsen Soryani
similarity 0.68
Abstract

Different MRI modalities reveal different parts of a brain tumor. Segmentation models combine information from these modalities to outline tumor regions. Many models use a separate encoder for each modality. However, exchanging features among these encoders at several stages can increase model complexity. We introduce the Block-Wise Shared Adapter (BWSA), which combines compressed features from the modality encoders in a shared path and returns adapted features to each stream. In its fixed-blending form, BWSA adds the adapted features to the original features. Its trainable-gated variant (TG-BWSA) instead learns separate weights for the original and adapted features at each modality and encoder stage. We evaluate both variants on BraTS 2020 and BraTS 2023 with four segmentation backbones. On the official BraTS 2023 online validation set, BWSA increases average region-wise Dice by 1.3--7.6 percentage points relative to the corresponding unmodified backbones. TG-BWSA increases it by 2.8--7.7 points. Both variants add approximately 0.85--3.73% parameters and reduce average HD95 relative to the unmodified backbones.

0.34

Image-Conditioned Diffusion Models for Quality Assurance of Organ-at-Risk Segmentations in Radiotherapy

cs.CV ·2026-08-24 ·Clea Dronne, Catharine H Clark, Xavier Loizeau, Elizabeth Miles, Peter Hoskin +1 more
hot direction similarity 0.68
Abstract · Submitted to the MICCAI 2026 UNSURE Workshop

Accurate organ-at-risk segmentation is essential for radiotherapy planning, but reviewing segmentations is time-consuming and subjective. We investigate normative modelling for segmentation error detection in head-and-neck CT, comparing a VAE framework with an image-conditioned segmentation diffusion model. Models were evaluated on RADCURE brainstem and spinal cord segmentations using simulated boundary and width perturbations. Error detection was assessed using the Dice similarity coefficient and the Distance to Agreement (DTA) between the input and reconstructed segmentations. While both models detected some simulated errors, regional DTA showed that the diffusion model localised subtle boundary errors more consistently. These results support image-conditioned diffusion reconstruction as a promising framework for localised, anatomy-aware segmentation QA.

0.36

Uncertainty as a Proxy for Semantic Correctness in Diffusion-Based Medical Image Synthesis

cs.CV cs.AI ·2026-10-02 ·Yuxuan Ou, Konstantinos Kamnitsas, OxAAA Study, AICT Consortium, Regent Lee +1 more
similarity 0.66
Abstract

Diffusion models can synthesise contrast-enhanced CT (CECT) from non-contrast CT (NCCT), avoiding contrast administration and its environmental and patient-access costs. However, visually realistic images are not necessarily anatomically correct, and the pixel-intensity and feature-space similarity metrics used to assess generation quality do not directly measure anatomical correctness. In this work, we investigate whether uncertainty can serve as a proxy for semantic correctness in diffusion-based medical image synthesis. We study NCCT-to-CECT synthesis using AortaDiff, a multitask diffusion framework that jointly generates CECT images and lumen segmentations. The segmentation output provides an explicit representation of the generated vascular anatomy, enabling segmentation-derived errors to be used as a quantitative measure of generation correctness. Six methods spanning weight (Ensemble, HyperDiff, BayesDiff), architecture-perturbation (MCDropout), generative-stochasticity (RDS) and input-perturbation (TTA) uncertainty are compared at the pixel, region and image levels, and for detection of clinically relevant out-of-distribution (OOD) cases. Uncertainty proves informative at all three spatial scales, remains informative on an external multi-centre dataset under distribution shift, and supports OOD detection. MCDropout stands out among the six: it ranks among the leading methods at every scale, generalizes well on the external dataset, and can be enabled at inference on any model already trained with dropout, so reliable uncertainty comes at no extra training cost. Uncertainty reliably flags severe failures but discriminates poorly among already high-quality images. These findings support uncertainty as a practical and computationally economical signal for quality filtering, reliability assessment and OOD detection in NCCT-to CECT synthesis.

0.14

Mixture of Multi-Sequence Feature Difference for Contrast-Enhanced MRI Synthesis

cs.CV ·2026-10-15 ·Jonghun Kim, Junmo Kwon, Hyunjin Park
similarity 0.65
Abstract · ACCV 2026

Contrast-enhanced magnetic resonance imaging (CE-MRI) is crucial for accurately diagnosing and segmenting brain tumors. However, the acquisition of CE-MRI requires injecting contrast agents, which poses potential health risks and increases scan costs. Here, we propose a CE-MRI synthesis method from non-contrast sequences, reducing both risk and cost. Unlike existing methods that rely on channel-wise concatenation to fuse multi-sequence information for synthesis, we introduce a Mixture of Feature Difference (MoFD) module. The proposed module uses a dynamic weighting strategy to adaptively select and aggregate informative features from both individual source sequences and explicit differences among them. Quantitative and qualitative evaluations demonstrate that our proposed method outperforms baselines in terms of image fidelity and perceptual quality on the UCSF-PDGM and UPenn-GBM datasets. Our method successfully reconstructs tumor regions and achieves segmentation performance comparable to that obtained with real CE-MRI. Our ablation studies show that although adversarial learning improves perceptual quality, a regression-based variant of our method achieves higher structural fidelity.

0.24