CS Paper Radar

Uncertainty as a Proxy for Semantic Correctness in Diffusion-Based Medical Image Synthesis

Yuxuan Ou, Konstantinos Kamnitsas, OxAAA Study, AICT Consortium, Regent Lee, Vicente Grau

cs.CV cs.AI ·submitted 2026-10-02 12:40 UTC · v1

Abstract

Diffusion models can synthesise contrast-enhanced CT (CECT) from non-contrast CT (NCCT), avoiding contrast administration and its environmental and patient-access costs. However, visually realistic images are not necessarily anatomically correct, and the pixel-intensity and feature-space similarity metrics used to assess generation quality do not directly measure anatomical correctness. In this work, we investigate whether uncertainty can serve as a proxy for semantic correctness in diffusion-based medical image synthesis. We study NCCT-to-CECT synthesis using AortaDiff, a multitask diffusion framework that jointly generates CECT images and lumen segmentations. The segmentation output provides an explicit representation of the generated vascular anatomy, enabling segmentation-derived errors to be used as a quantitative measure of generation correctness. Six methods spanning weight (Ensemble, HyperDiff, BayesDiff), architecture-perturbation (MCDropout), generative-stochasticity (RDS) and input-perturbation (TTA) uncertainty are compared at the pixel, region and image levels, and for detection of clinically relevant out-of-distribution (OOD) cases. Uncertainty proves informative at all three spatial scales, remains informative on an external multi-centre dataset under distribution shift, and supports OOD detection. MCDropout stands out among the six: it ranks among the leading methods at every scale, generalizes well on the external dataset, and can be enabled at inference on any model already trained with dropout, so reliable uncertainty comes at no extra training cost. Uncertainty reliably flags severe failures but discriminates poorly among already high-quality images. These findings support uncertainty as a practical and computationally economical signal for quality filtering, reliability assessment and OOD detection in NCCT-to CECT synthesis.

Closest papers

Nearest neighbours by meaning across the whole index.

MUMINS: Metadata-conditioned Uncertainty-aware Medical Image Next-state Synthesis

cs.CV cs.AI ·2026-09-15 ·Anna Oliveras, Roger Marí, Rafael Redondo, Oriol Guardià, Cynthia Ifeyinwa Ugwu +5 more
code/data similarity 0.73
Abstract · Supplementary material to follow in future versions

Forecasting anatomical changes such as tumor growth and neurodegeneration is a challenging generative vision task. Morphological evolution is subtle relative to static anatomy, highly patient-specific, and inherently stochastic. Existing methods struggle with several issues: deterministic networks ignore biological stochasticity, while standard diffusion models require computationally prohibitive multi-pass sampling to quantify uncertainty. We propose MUMINS (Metadata-conditioned Uncertainty-aware Medical Image Next-state Synthesis), an efficient diffusion framework that jointly diffuses a baseline scan and its follow-up residual, summed to synthesize the follow-up scan, while concurrently predicting a spatial uncertainty map, in a single reverse diffusion process. Conditioned on the time interval and relevant metadata, it preserves fine-grained anatomy by dynamically re-injecting the baseline as a soft anchor at every denoising step, and a negative-log-likelihood head learns the uncertainty map to explicitly flag error-prone regions. Designed without organ-specific heuristics, the same architecture is reused across anatomies via separate, dataset-specific retraining. Extensive evaluations demonstrate that dataset-specific retraining of MUMINS matches or outperforms dedicated, domain-specific state-of-the-art methods on lung CT (PNG) and brain MRI (OASIS-3). Project page: https://aolivtous.github.io/publications/mumins.html.

0.47

3D Diffusion Models for Medical Imaging

cs.CV ·2026-10-19 ·Frank-Peter Schilling, Daniel Barco, Philipp Denzel, Marc Stadelmann
publishedsurvey similarity 0.69
Abstract · 27 pages, accepted for publication in Informatics in Medicine Unlocked

Generative deep learning methods such as Variational Autoencoders, Generative Adversarial Networks or Diffusion Models have achieved remarkable results in image synthesis. In particular, Diffusion Models have demonstrated superior image fidelity and sample diversity compared to other approaches on standard benchmarks, while also offering more flexible training dynamics as evidenced both in natural image domains and in medical applications. In medical imaging including Computed Tomography, Magnetic Resonance Imaging or Positron Emission Tomography, such models have various important use-cases including data augmentation, domain transfer, image reconstruction, inpainting, image augmentation and artifact correction. Further, generated images can be conditioned on patient characteristics, medical reports, segmentation masks or other images. Specific challenges arise due to the 3D volumetric nature of medical images, which translate to substantial demands in terms of memory, compute, and training data. This article provides a comparative overview of 3D Diffusion Models which have been developed for medical images, with a focus on current performance, limitations, and an outlook for future work.

0.23

Image-Conditioned Diffusion Models for Quality Assurance of Organ-at-Risk Segmentations in Radiotherapy

cs.CV ·2026-08-24 ·Clea Dronne, Catharine H Clark, Xavier Loizeau, Elizabeth Miles, Peter Hoskin +1 more
hot direction similarity 0.68
Abstract · Submitted to the MICCAI 2026 UNSURE Workshop

Accurate organ-at-risk segmentation is essential for radiotherapy planning, but reviewing segmentations is time-consuming and subjective. We investigate normative modelling for segmentation error detection in head-and-neck CT, comparing a VAE framework with an image-conditioned segmentation diffusion model. Models were evaluated on RADCURE brainstem and spinal cord segmentations using simulated boundary and width perturbations. Error detection was assessed using the Dice similarity coefficient and the Distance to Agreement (DTA) between the input and reconstructed segmentations. While both models detected some simulated errors, regional DTA showed that the diffusion model localised subtle boundary errors more consistently. These results support image-conditioned diffusion reconstruction as a promising framework for localised, anatomy-aware segmentation QA.

0.36

VascuSR: Iterative Anatomy-Aware Diffusion for CT Super-Resolution

cs.CV cs.AIcs.LG ·2026-10-14 ·Hairong Ni, Jiahe Huang, Minghao Guo, Wojciech Matusik, Rose Yu
similarity 0.67
Abstract

Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing high-frequency content is not uniquely determined by the low-resolution input. Consequently, visually plausible reconstructions may contain anatomically unsupported vascular detail, such as missing, spurious, or incorrectly connected vessels. To overcome this challenge, we introduce VascuSR, an iterative anatomy-aware diffusion framework that combines image reconstruction with explicit 3D vascular guidance. First, to provide richer anatomical guidance, we use an explicit 3D vascular representation that captures structural information beyond individual slices. This representation also simplifies vascular refinement by allowing a lightweight 3D generative refiner to focus on vascular structure rather than complex CT appearance. Second, to guide slice-wise SR, a lightweight anatomy controller injects the refined structure into the diffusion decoder, while iterative feedback updates this guidance from each new SR volume. On re-annotated MSD Task08 and HVM datasets, VascuSR outperforms interpolation and learning-based SR baselines in segmentation accuracy (Dice and clDice) and 3D vascular structure (connectivity and mean centerline distance), while maintaining image quality comparable to its SR backbone. Compared with learning-based baselines, VascuSR reduces class-averaged connected-component counts by over 20% on both datasets and mean centerline distance by over 10% on MSD.

0.23

CAPS: Clinically-Verifiable Anatomy-Prioritized Synthesis for Missing MRI Imputation in Brain Tumor Segmentation

eess.IV cs.CV ·2026-10-20 ·Cecilia Diana-Albelda, Arthur Longuefosse, Mario Rubén Paz Campos, Álvaro García-Martín, Jesus Bescos
similarity 0.67
Abstract · 20 pages, 6 figures, 8 tables. Cecilia Diana-Albelda and Arthur Longuefosse contributed equally

Multi-parametric MRI is the gold standard for neuro-oncology, yet acquiring complete 4-modality protocols may be unfeasible in real-world clinical practice. When handling missing modalities, existing automated systems force a critical compromise: robust segmenters operate as uninterpretable "black boxes" that bypass image generation, while standard synthesis models often produce blurry reconstructions lacking diagnostic reliability. To address this issue, we propose CAPS, a Clinically-Verifiable Anatomy-Prioritized Synthesis framework that reconciles computational precision with clinical transparency. Our multi-modal generative architecture is driven by a hybrid objective function (L_1 + L_AFP + L_DualDice) that explicitly enforces the preservation of deep anatomical features and strict topological boundaries, rather than relying solely on pixel-wise optimization. Evaluated comprehensively on the BraTS Adult Glioma dataset, the framework achieves superior synthesis fidelity across intensity-based metrics, and demonstrates robust downstream segmentation performance (82.38% mean Dice), successfully restoring verifiable visual context. Furthermore, the framework exhibits exceptional zero-shot cross-domain generalization, maintaining high structural fidelity across completely unseen Meningioma, Pediatric, and Sub-Saharan African cohorts without domain-specific adaptation. Finally, a blinded radiological assessment confirms that our anatomy-aware approach significantly enhances both perceived image quality and clinical utility, providing clinicians with the reliable visual evidence required to trust downstream automated workflows.

0.20

Unsupervised Anatomical Feature Learning via Diffusion Models: Enhanced Medical Image Segmentation with Denoising Diffusion Probabilistic Models

cs.CV cs.AIcs.LG ·2026-08-26 ·Akshat G, Divyansh Gupta, Shaleen Bhatnagar, Shilpa Ankalaki, Tusar Kanti Mishra
similarity 0.67
Abstract · 15 pages, 5 figures. Submitted for peer review

Acquiring pixel-level annotations for medical image segmentation is a severe bottleneck. Traditional U-Net architectures, while effective, learn local texture patterns and lack awareness of global anatomical structures, leading to boundary delineation failures in low-data regimes. This research paper proposes utilizing unsupervised Denoising Diffusion Probabilistic Models (DDPMs) to extract anatomical features. We train a DDPM on 21 unlabeled abdominal CT scans to learn structural representations, transferring the encoder weights to a downstream segmentation task evaluated on the BTCV multi-organ dataset. Diffusion pretraining significantly improved liver segmentation: Dice increased from $0.75\pm0.36$ to $0.93\pm0.16$ ($p < 5.33\times10^{-26}$, 0.529 Cohen's d), Average Surface Distance (ASD) decreased by 66%, and 95th-percentile Hausdorff Distance (HD95) reduced by 45%. For kidney segmentation, Dice improved from $0.90\pm0.19$ to $0.95\pm0.10$ ($p < 4.01\times10^{-11}$). Multi-organ pooled performance showed a 68% variance reduction and a 74% improvement in boundary precision (Dice $0.95\pm0.07$). Crucially, frozen encoder models retained > 80% of fine-tuned performance without exposure to segmentation labels, proving the existence of learned anatomical priors. In low-data scenarios, diffusion-pretrained models maintained robust performance with only 50% (Dice: 0.92 liver, 0.94 kidney), 25%, and even 10% (Dice: 0.89 liver, 0.71 kidney) of labeled data. Using unlabeled images for diffusion-based pretraining successfully embeds robust anatomical features prior to human supervision, transforming U-Nets into anatomy-aware systems.

0.21

Diffusion-Based Tumor Inpainting for Renal Segmentation under Clinical Data Scarcity

cs.CV ·2026-09-18 ·Ekaterina Sedykh, Salme Ussanov, Dmytro Fedorenko, Dmytro Fishman
similarity 0.66
Abstract

Deep learning segmentation of renal tumors requires large annotated datasets, yet clinical deployments typically offer only a handful of tumor-positive cases from the target site. We propose a diffusion-based inpainting framework that synthesizes anatomically plausible renal tumors within healthy CT scans, requiring no additional annotation, and provide the first systematic comparison of 2D, 2.5D, and full 3D (MAISI) synthesis strategies for this task. Training the diffusion model on public data (KiTS23, KIRC) and evaluating nnU-Net segmentation on a internal cohort across three low-data regimes, we find that 2.5D and 3D augmentation substantially reduce false positives (from $\sim$18--20\% to $\sim$3--6\%) while maintaining Dice, whereas 2D provides no consistent benefit. Crucially, the proposed 2.5D method matches full 3D synthesis on every metric at substantially lower computational cost, indicating that local volumetric consistency alone is sufficient for effective augmentation in data- and resource-scarce clinical settings.

0.12

Spatially and Compositionally Controlled Multimodal Glioblastoma MRI Synthesis with Latent Diffusion

cs.CV ·2026-11-04 ·Steven Glass, Max Van Puyvelde, Marija Pizurica, Mia Meyer, Olivier Gevaert +1 more
similarity 0.66
Abstract

Glioblastoma exhibits substantial heterogeneity in tumour morphology and composition across MRI modalities, often making available clinical datasets highly unbalanced in terms of patient pathologies. We propose a two-stage latent diffusion model (LDM) framework for the generation of explicitly controllable 2D glioblastoma MRI scans. First, a segmentation LDM generates tumour maps conditioned on location, spatial extent, axial position, and subregion composition. Second, a modality-conditioned LDM with ControlNet generates T1, T1Gd, T2, and FLAIR images adhering to the requested segmentation. On a held-out test set, generated segmentations achieved a mean centroid error of 0.842 pixels and a subregion proportion error of 0.795 percentage points. ControlNet improved Fréchet inception distance (FID) across all four modalities, reducing pooled FID from 42.59 to 36.12. An expert reader study yielded mean quality ratings of 6.60 for real images, 6.83 for ControlNet-generated images, and 6.77 for fully synthetic images.

0.20