CS Paper Radar

GliomaINK: A Tumor and Anatomy Conditioned Flow Matching Framework for 3D MRI Sequence Synthesis in Glioma Patients

Moinak Bhattacharya, Annie Singh, Mohammad Chaudhry, Prateek Prasanna, Gagandeep Singh

eess.IV cs.CVq-bio.TO ·submitted 2026-10-16 15:09 UTC · v1

Abstract

Background: Incomplete multiparametric MR examinations limit glioma characterization and downstream AI tools. Generative models can synthesize missing MRI sequences, but anatomical structure and clinically relevant tumor features are challenging to preserve. We propose GliomaINK, an anatomy-guided conditional flow matching framework for cross-sequence 3D brain MRI synthesis. Methods: A 3D SwinUNETR predicted the conditional velocity field while an auxiliary topology-preserving loss encouraged structural consistency. The model was trained on 1,083 patients from the BraTS-AG dataset and independently tested on an in-house clinical cohort. Downstream tasks include image quality, tumor segmentation, IDH1 mutation-status prediction, and overall survival prediction. Two radiologists independently evaluated the anatomical fidelity, pathological representation, and overall image quality of the synthesized images. Results: GliomaINK exhibited the highest PSNR across all six MRI translation directions in both evaluation cohorts. In the BraTS-AG test set, the PSNR reached $25.64\pm0.55$ dB for the T2W-to-T1C synthesis, compared with $13.78\pm0.32$ dB for Pix2Pix and $18.90\pm0.53$ dB for SPADE. For downstream tumor segmentation, the method showed strong performance across tumor subregions with Dice scores reaching $0.928\pm0.014$ for edema, and $0.885\pm0.040$ for enhancing tumor. For the IDH1 mutation-status prediction, GliomaINK achieved the highest AUROC score in four of the six sequence configurations, reaching $0.827\pm0.088$. Conclusion: Anatomy-guided conditional flow matching enables high-fidelity cross-sequence glioma MRI synthesis demonstrating potential for preservation of clinically relevant information in synthesized MRI and improving downstream tasks.

Closest papers

Nearest neighbours by meaning across the whole index.

CAPS: Clinically-Verifiable Anatomy-Prioritized Synthesis for Missing MRI Imputation in Brain Tumor Segmentation

eess.IV cs.CV ·2026-10-20 ·Cecilia Diana-Albelda, Arthur Longuefosse, Mario Rubén Paz Campos, Álvaro García-Martín, Jesus Bescos
similarity 0.75
Abstract · 20 pages, 6 figures, 8 tables. Cecilia Diana-Albelda and Arthur Longuefosse contributed equally

Multi-parametric MRI is the gold standard for neuro-oncology, yet acquiring complete 4-modality protocols may be unfeasible in real-world clinical practice. When handling missing modalities, existing automated systems force a critical compromise: robust segmenters operate as uninterpretable "black boxes" that bypass image generation, while standard synthesis models often produce blurry reconstructions lacking diagnostic reliability. To address this issue, we propose CAPS, a Clinically-Verifiable Anatomy-Prioritized Synthesis framework that reconciles computational precision with clinical transparency. Our multi-modal generative architecture is driven by a hybrid objective function (L_1 + L_AFP + L_DualDice) that explicitly enforces the preservation of deep anatomical features and strict topological boundaries, rather than relying solely on pixel-wise optimization. Evaluated comprehensively on the BraTS Adult Glioma dataset, the framework achieves superior synthesis fidelity across intensity-based metrics, and demonstrates robust downstream segmentation performance (82.38% mean Dice), successfully restoring verifiable visual context. Furthermore, the framework exhibits exceptional zero-shot cross-domain generalization, maintaining high structural fidelity across completely unseen Meningioma, Pediatric, and Sub-Saharan African cohorts without domain-specific adaptation. Finally, a blinded radiological assessment confirms that our anatomy-aware approach significantly enhances both perceived image quality and clinical utility, providing clinicians with the reliable visual evidence required to trust downstream automated workflows.

0.20

Spatially and Compositionally Controlled Multimodal Glioblastoma MRI Synthesis with Latent Diffusion

cs.CV ·2026-11-04 ·Steven Glass, Max Van Puyvelde, Marija Pizurica, Mia Meyer, Olivier Gevaert +1 more
similarity 0.75
Abstract

Glioblastoma exhibits substantial heterogeneity in tumour morphology and composition across MRI modalities, often making available clinical datasets highly unbalanced in terms of patient pathologies. We propose a two-stage latent diffusion model (LDM) framework for the generation of explicitly controllable 2D glioblastoma MRI scans. First, a segmentation LDM generates tumour maps conditioned on location, spatial extent, axial position, and subregion composition. Second, a modality-conditioned LDM with ControlNet generates T1, T1Gd, T2, and FLAIR images adhering to the requested segmentation. On a held-out test set, generated segmentations achieved a mean centroid error of 0.842 pixels and a subregion proportion error of 0.795 percentage points. ControlNet improved Fréchet inception distance (FID) across all four modalities, reducing pooled FID from 42.59 to 36.12. An expert reader study yielded mean quality ratings of 6.60 for real images, 6.83 for ControlNet-generated images, and 6.77 for fully synthetic images.

0.20

MOSAIC-Flow: Orthogonal-Axis and Status-Conditioned Fusion for Missing-Sequence Completion in Brain Tumor MRI

cs.CV ·2026-10-29 ·Pengli Zhu, Zhihao Peng, Yixuan Yuan
code/data similarity 0.72
Abstract · 5 pages, 4 figures

Missing-sequence completion is important for comprehensive brain tumor characterization, but cross-modal fusion can obscure sequence-specific contrast and lose fine-grained three-dimensional tumor detail. To address this challenge, we introduce Modality-aware Orthogonal-axis Status-conditioned Attentive Integration for Completion (MOSAIC-Flow), a unified framework for missing-sequence completion that learns a target-conditioned velocity field while keeping the seven acquired volumes fixed throughout the transport. Specifically, modality-aware stems independently encode each sequence, and orthogonal-axis refinement captures axial, coronal, and sagittal dependencies while retaining the three-dimensional representation. Status-conditioned prototype fusion uses compact modality and availability tokens to route and modulate pooled queries from the fused visual representation, enabling target-adaptive conditioning without dense voxel-to-voxel attention. A conditional flow matching objective transports target-channel noise toward the single missing sequence, while four Heun trajectories are averaged to produce the completion. Evaluation across structural, diffusion, and contrast-enhanced MRI in UCSF-PDGM demonstrates consistent whole-brain and tumor-region fidelity across all eight single-target completion tasks, with the strongest performance on structural sequences. Code is available at https://github.com/CUHK-AIM-Group/MOSAIC-FLOW.

0.21

Conditional Flow Matching for Cross-Field MRI Harmonisation

cs.CV ·2026-09-01 ·Baris Imre, Aram Salehi, Levente Baljer, Andrew Webb, Marius Staring +1 more
similarity 0.69
Abstract · 10 pages, 2 figures

Magnetic resonance images of the same subject look markedly different across field strengths, which complicates the comparison and pooling of data across sites. We address cross-field brain-MRI translation for the MRIxFields2026 challenge, and in particular its Task~3: a single model that translates between any directed pair of the five field strengths and across three contrasts. We phrase the problem as a conditional flow matching path: because the source and target volumes are spatially registered, we learn a velocity field that carries the source slice directly to the target slice, rather than starting from noise. To learn this mapping from only three paired subjects, the unified model is trained in three stages: a degradation-bridge pretraining that distills a restoration prior from the abundant unpaired retrospective cohort, a cross-field finetuning over all directed pairs on the paired cohort, and an adversarial refinement that sharpens the output. At inference, we integrate the learned velocity with a second-order Heun solver in a handful of steps. A restoration prior learned without any paired data already reaches a mean SSIM of 0.837, and each subsequent training stage improves on it. A single 6.3M-parameter model thereby covers all 60 field-pair and contrast combinations, with inference in five solver steps per slice. On the challenge evaluation set the model reaches a mean SSIM of 0.909, averaged over the three contrasts, outperforming regression and diffusion baselines built on the identical network on all three challenge metrics.

0.22

A Tumour-Aware Multimodal Framework for Explainable Prediction of IDH Mutation in Gliomas from Multi-Sequence MRI

eess.IV cs.CV ·2026-11-13 ·Tahsien Al-Quraishi, Waseem Alwan Zaboon, O. S. Albahri, Raza Nowrozy
similarity 0.69
Abstract · 45 pages, 12 figures, 4 tables. Preprint of an article submitted for consideration in International Journal of Information Technology & Deci…

Accurate prediction of isocitrate dehydrogenase (IDH) mutation status is essential for glioma diagnosis, prognosis, and treatment planning. Although recent deep learning approaches have demonstrated promising performance, many rely on whole-brain feature extraction and provide limited interpretability. This study proposes a tumour-aware multimodal framework for explainable, non-invasive prediction of IDH mutation status from multiparametric magnetic resonance imaging (MRI). The proposed framework integrates four MRI sequences (T1, T1CE, T2, and FLAIR), tumour subregion segmentation, quantitative radiomic descriptors, and clinical information within a unified deep learning architecture. An ablation study was conducted to evaluate the contribution of tumour-aware learning, radiomic features, and clinical variables. Model performance was assessed using multiple complementary evaluation metrics, including accuracy, precision, recall, F1-score, balanced accuracy, receiver operating characteristic analysis, confusion matrix evaluation, and Grad-CAM visualisation. Experimental results demonstrated that the proposed multimodal framework consistently outperformed the baseline MRI-only model, with the Clinical Fusion model achieving the strongest overall predictive performance. The integration of tumour-aware learning, radiomic descriptors, and clinical information progressively improved classification performance, while Grad-CAM visualisations indicated that the model predominantly focused on biologically relevant tumour regions. These findings suggest that tumour-aware multimodal feature integration enables accurate, interpretable, and non-invasive molecular profiling of gliomas and provides a promising foundation for future clinical decision support in precision neuro-oncology.

0.11

MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models

cs.CV cs.AIcs.LG ·2026-08-10 ·Lisa K. Fischer, Mykhailo Riabets, Daniel Rueckert, Benedikt Wiestler, Anke Meyer-Baese +1 more
publishedcode/data similarity 0.69
Abstract · Accepted: MICCAI 2026 SASHIMI workshop

Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin ($Δ$PSNR $<1$,dB, $Δ$SSIM $<0.02$; paired TOST $p=[[p]]$): mean PSNR is 27.3,dB vs. 27.0,dB and mean SSIM is 0.95 vs. 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The codebase is available at https://github.com/lisafis/MRIComp4Flow .

0.38

CFB-GBM v2.0: An Augmented Longitudinal Dataset for Multi-Modal Glioblastoma Segmentation, Radiomics, and RANO Progression Tracking

cs.CV ·2026-08-18 ·Alexandre G. Leclercq, Noémie N. Moreau, Hugo Audebert, Andros Nassar, Thomas Cochin +19 more
top venue similarity 0.69
Abstract · 9 pages, 2 figures,

Glioblastoma (GBM) is the most aggressive primary brain tumor in adults, with a median overall survival of 15 months. Longitudinal, multi-modal imaging datasets with comprehensive clinical and treatment data are essential to support the development of reproducible computational methods for treatment response prediction, disease progression modelling, and personalized medicine. We present CFB-GBM v2.0, an extension of our previously released CFB-GBM dataset comprising 264 GBM patients treated according to the standard Stupp protocol. The primary contribution of this release is the completion of Gross Tumour Volume (GTV) delineations across all available timepoints ($t_0$, $t_1$ and $t_2$), increasing the overall GTV completion rate from 35% to 97%. This was achieved using a nnU-Net model pre-trained on BraTS 2021 and fine-tuned on CFB-GBM ground-truth contours, with the generated segmentations validated by five radiation oncologists. From these longitudinal GTV annotations, volumetric RANO 2.0 response category labels were derived for all available temporality pairs ($t_0 \rightarrow t_1$, $t_0 \rightarrow t_2$ and $t_1 \rightarrow t_2$). To further ease dataset usability and reproducibility, brain masks computed with HD-BET and pre-computed radiomic features extracted with PyRadiomics are provided for each patient timepoint and MRI modality. Additionally, the WHO classification guideline (2016 vs. 2021) applicable to each patient's diagnosis is now explicitly documented. CFB-GBM v2.0 is publicly available on The Cancer Imaging Archive (TCIA) at https://www.cancerimagingarchive.net/collection/cfb-gbm .

0.67

Parameter-Efficient Multimodal Brain Tumor Segmentation With Stage-Wise Shared Adapters

cs.CV ·2026-10-13 ·Milad Rostamian, Mohammadreza Mohammadi, Ender Konukoglu, Mohsen Soryani
similarity 0.68
Abstract

Different MRI modalities reveal different parts of a brain tumor. Segmentation models combine information from these modalities to outline tumor regions. Many models use a separate encoder for each modality. However, exchanging features among these encoders at several stages can increase model complexity. We introduce the Block-Wise Shared Adapter (BWSA), which combines compressed features from the modality encoders in a shared path and returns adapted features to each stream. In its fixed-blending form, BWSA adds the adapted features to the original features. Its trainable-gated variant (TG-BWSA) instead learns separate weights for the original and adapted features at each modality and encoder stage. We evaluate both variants on BraTS 2020 and BraTS 2023 with four segmentation backbones. On the official BraTS 2023 online validation set, BWSA increases average region-wise Dice by 1.3--7.6 percentage points relative to the corresponding unmodified backbones. TG-BWSA increases it by 2.8--7.7 points. Both variants add approximately 0.85--3.73% parameters and reduce average HD95 relative to the unmodified backbones.

0.35