CS Paper Radar

Conditional Flow Matching for Cross-Field MRI Harmonisation

Baris Imre, Aram Salehi, Levente Baljer, Andrew Webb, Marius Staring, Efe Ilicak

cs.CV ·submitted 2026-09-01 09:18 UTC · v1

Abstract

Magnetic resonance images of the same subject look markedly different across field strengths, which complicates the comparison and pooling of data across sites. We address cross-field brain-MRI translation for the MRIxFields2026 challenge, and in particular its Task~3: a single model that translates between any directed pair of the five field strengths and across three contrasts. We phrase the problem as a conditional flow matching path: because the source and target volumes are spatially registered, we learn a velocity field that carries the source slice directly to the target slice, rather than starting from noise. To learn this mapping from only three paired subjects, the unified model is trained in three stages: a degradation-bridge pretraining that distills a restoration prior from the abundant unpaired retrospective cohort, a cross-field finetuning over all directed pairs on the paired cohort, and an adversarial refinement that sharpens the output. At inference, we integrate the learned velocity with a second-order Heun solver in a handful of steps. A restoration prior learned without any paired data already reaches a mean SSIM of 0.837, and each subsequent training stage improves on it. A single 6.3M-parameter model thereby covers all 60 field-pair and contrast combinations, with inference in five solver steps per slice. On the challenge evaluation set the model reaches a mean SSIM of 0.909, averaged over the three contrasts, outperforming regression and diffusion baselines built on the identical network on all three challenge metrics.

Comment
10 pages, 2 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Task-Adaptive 3D Cross-Field MRI Translation via Field-Conditioned Content-Style Pretraining

cs.CV ·2026-08-10 ·Haowen Pang, Yingqi Hao, Pengli Zhu
publishedcode/data similarity 0.78
Abstract · MICCAI 2026 Workshop on MRIxFields

Magnetic field strength is a major source of domain shift in magnetic resonance imaging (MRI), affecting signal-to-noise ratio, tissue contrast, spatial detail, and the visibility of anatomical boundaries. The MRIxFields 2026 challenge investigates this problem through cross-field MRI translation across acquisitions at 0.1T, 1.5T, 3T, 5T, and 7T. Its three tasks, Any-to-7T, 0.1T-to-High, and Any-to-Any synthesis, require the generation of target-field image characteristics while preserving subject-specific anatomy. This problem is particularly challenging because paired acquisitions of the same subject across multiple field strengths are rarely available for training. We propose a 3D unpaired cross-field MRI translation framework based on field-conditioned content-style pretraining. The proposed framework first learns controllable field-to-field translation across all available field strengths by disentangling anatomical content from field-dependent contrast characteristics. The pretrained backbone is then adapted to task-specific target domains. Our model comprises a 3D content encoder, a 3D style encoder, a field-conditioned style generator, an AdaIN-modulated decoder, and a multi-field discriminator. Adversarial learning encourages realistic target-field appearance, while cycle-consistency, identity, content, style, and diversity constraints promote anatomical fidelity and controllable translation. We evaluate the proposed method on MRIxFields data spanning five field strengths and three MRI modalities. Experiments on paired test data demonstrate that the framework can adapt to the three challenge settings while preserving three-dimensional anatomical structure in the synthesized volumes. The implementation code is publicly available at https://github.com/Idea89560041/3D-MRI-Field-Translation.

0.71

Fast Cross-Strength Multi-Contrast Brain MRI Translation using Latent Bridge Matching

cs.CV cs.LG ·2026-09-17 ·Siddharth Srivastava, Till Bretschneider
publishedcode/data similarity 0.75
Abstract · 10 pages, 4 figures. MRIxFields Workshop, MICCAI 2026

Magnetic Resonance Imaging (MRI) acquired at different field strengths exhibits pronounced variation in noise, resolution, homogeneity, and contrast, which limits comparability across acquisition settings and complicates downstream analysis. We address this with a unified conditional model for controllable field-to-field synthesis, built on the framework of conditional latent bridge matching. Our single model achieves highly competitive results across the validation phase for all three tasks of the MRIxFields2026 challenge without task-specific architectures or training. We achieve fast generation with only a single inference step, producing all modality and field-strength combinations for $30$ axial slices in under $90$ seconds, as well as cross-modality-strength translation for a full volume in under $70$ seconds, on a single NVIDIA A5000 GPU. We further provide extensive ablations regarding different components of our solution. Code: https://gitlab.com/siddharthsrivastava/mrixfields-2026

0.38

MOSAIC-Flow: Orthogonal-Axis and Status-Conditioned Fusion for Missing-Sequence Completion in Brain Tumor MRI

cs.CV ·2026-10-29 ·Pengli Zhu, Zhihao Peng, Yixuan Yuan
code/data similarity 0.72
Abstract · 5 pages, 4 figures

Missing-sequence completion is important for comprehensive brain tumor characterization, but cross-modal fusion can obscure sequence-specific contrast and lose fine-grained three-dimensional tumor detail. To address this challenge, we introduce Modality-aware Orthogonal-axis Status-conditioned Attentive Integration for Completion (MOSAIC-Flow), a unified framework for missing-sequence completion that learns a target-conditioned velocity field while keeping the seven acquired volumes fixed throughout the transport. Specifically, modality-aware stems independently encode each sequence, and orthogonal-axis refinement captures axial, coronal, and sagittal dependencies while retaining the three-dimensional representation. Status-conditioned prototype fusion uses compact modality and availability tokens to route and modulate pooled queries from the fused visual representation, enabling target-adaptive conditioning without dense voxel-to-voxel attention. A conditional flow matching objective transports target-channel noise toward the single missing sequence, while four Heun trajectories are averaged to produce the completion. Evaluation across structural, diffusion, and contrast-enhanced MRI in UCSF-PDGM demonstrates consistent whole-brain and tumor-region fidelity across all eight single-target completion tasks, with the strongest performance on structural sequences. Code is available at https://github.com/CUHK-AIM-Group/MOSAIC-FLOW.

0.21

Generalizable field of view extension for diffusion MRI via conditional flow matching

cs.AI ·2026-10-12 ·Gaurav Rudravaram, Lianrui Zuo, Ema Topolnjak, Michael E. Kim, Adam M. Saunders +20 more
similarity 0.71
Abstract

Incomplete field-of-view (FOV) diffusion MRI (dMRI) acquisitions compromise whole-brain white matter analysis by excluding brain regions from tractography and connectivity studies. While deep generative models for dMRI FOV extension have been proposed, their generalizability remains limited by the acquisition-dependent nature of dMRI, where signal intensity varies with b-value, gradient direction, and scanner protocol, and the inherent 4D complexity of the data, making it difficult to train models that transfer across sites or acquisition schemes without retraining. We propose a flow-matching generative model that extends the dMRI FOV in both the superior and inferior directions by predicting apparent diffusion coefficients (ADC) in six directions, conditioned on the two nearest acquired slices and the full-FOV T1w image to enforce both local diffusion continuity and anatomical consistency. The ADC representation decouples the model from acquisition-specific b-values and gradient directions, providing a middle-ground across protocols. The model was trained on 3,103 subjects (5,105 sessions) across five different datasets spanning diverse acquisition schemes (b = 500 and 1000 s/mm$^2$; 21--192 gradient directions), four single-shell (b = 1000) and one multi-shell (b = 500/1000). Evaluated on 299 subjects across five independent datasets spanning b = 750--1500 s/mm$^2$ and 32--90 gradient directions, with single- and multi-shell schemes unseen during training, the proposed method achieves significantly improved bundle Dice score on downstream tractography (p < 0.01).

0.16

UniField++: A Unified Agentic Framework with Loop Reasoning for MRI Field-Strength Enhancement

cs.CV ·2026-10-16 ·Yiyang Lin, Chenhui Wang, Tianliang Yao, Pengli Zhu, Shuaibo Li +3 more
code/data similarity 0.71
Abstract · 10 pages, 6 figures, 8 tables

MRI field-strength enhancement seeks to combine the accessibility of low-field scanners with the image quality of high-field scanners. Yet, existing methods remain prone to anatomical hallucinations, as uniform processing leaves difficult brain regions insufficiently examined and scarce paired data limit their learning of how tissue contrast and anatomical visibility change across field strengths. To address these challenges, we propose UniField++, a two-agent framework that unifies enhancement tasks across multiple field-strength transitions, including 64mT-to-3T and 3T-to-7T. Unified learning allows both the VLM-based planner and the flow-matching-based enhancer to draw on field-dependent image characteristics observed across tasks, rather than relying on a single transition. Trained with radiologists' annotations of hallucination-prone regions and corresponding correction plans, the planner predicts regional risk and formulates targeted restoration strategies. Guided by these plans, the enhancer performs loop reasoning along the flow-matching trajectory, repeatedly processing high-risk regions for additional refinement. Together, cross-transition learning and risk-guided refinement support anatomically faithful enhancement across field strengths. Across the evaluated tasks, UniField++ improves PSNR by an average of 2.74 dB and SSIM by 14.05 percentage points over comparison methods, with corresponding gains of 3.97 dB and 13.92 percentage points over the ablation baseline. It also maintains enhancement quality on an external cohort with an unseen field strength and improves downstream whole-brain segmentation Macro Dice by an average of 0.1457 over the original low-field images. Code is available at https://github.com/CUHK-AIM-Group/UniField_plusplus.

0.31

GliomaINK: A Tumor and Anatomy Conditioned Flow Matching Framework for 3D MRI Sequence Synthesis in Glioma Patients

eess.IV cs.CVq-bio.TO ·2026-10-16 ·Moinak Bhattacharya, Annie Singh, Mohammad Chaudhry, Prateek Prasanna, Gagandeep Singh
similarity 0.69
Abstract

Background: Incomplete multiparametric MR examinations limit glioma characterization and downstream AI tools. Generative models can synthesize missing MRI sequences, but anatomical structure and clinically relevant tumor features are challenging to preserve. We propose GliomaINK, an anatomy-guided conditional flow matching framework for cross-sequence 3D brain MRI synthesis. Methods: A 3D SwinUNETR predicted the conditional velocity field while an auxiliary topology-preserving loss encouraged structural consistency. The model was trained on 1,083 patients from the BraTS-AG dataset and independently tested on an in-house clinical cohort. Downstream tasks include image quality, tumor segmentation, IDH1 mutation-status prediction, and overall survival prediction. Two radiologists independently evaluated the anatomical fidelity, pathological representation, and overall image quality of the synthesized images. Results: GliomaINK exhibited the highest PSNR across all six MRI translation directions in both evaluation cohorts. In the BraTS-AG test set, the PSNR reached $25.64\pm0.55$ dB for the T2W-to-T1C synthesis, compared with $13.78\pm0.32$ dB for Pix2Pix and $18.90\pm0.53$ dB for SPADE. For downstream tumor segmentation, the method showed strong performance across tumor subregions with Dice scores reaching $0.928\pm0.014$ for edema, and $0.885\pm0.040$ for enhancing tumor. For the IDH1 mutation-status prediction, GliomaINK achieved the highest AUROC score in four of the six sequence configurations, reaching $0.827\pm0.088$. Conclusion: Anatomy-guided conditional flow matching enables high-fidelity cross-sequence glioma MRI synthesis demonstrating potential for preservation of clinically relevant information in synthesized MRI and improving downstream tasks.

0.18

FlowMoDL: Model-Based Deep Learning with Conjugate-Gradient Data Consistency for Highly Accelerated 4D Flow MRI Reconstruction

cs.CV cs.LG ·2026-08-26 ·Tristan Gottwald, Michelle Bruch, Mubashir-Ul Hassan, Fatma Alickovic, Milan Kloiber +4 more
similarity 0.67
Abstract

We present FlowMoDL, an unrolled neural network for highly accelerated 4D flow MRI reconstruction that directly optimizes for both anatomical magnitude and phase-derived velocity accuracy. Building on the MoDL framework, FlowMoDL alternates a learned (3+1)D spatiotemporal denoiser with conjugate-gradient data-consistency updates based on the SENSE forward model. A novel dual-pathway conditioning scheme adapts the denoiser features and data-consistency weighting, enabling a single model to handle varying acceleration factors ($10\times$ to $50\times$). To ensure physiological accuracy, the network is trained using a deep-supervision composite loss that explicitly penalizes velocity magnitude and angular errors, stabilized by a curriculum schedule. We evaluate FlowMoDL on the multi-center CMRx4DFlow dataset against classical and deep-learning baselines (CG-SENSE, MoDL, FlowVN, and FlowMRI-Net). A key advantage of FlowMoDL is its superior gradient step efficiency. When evaluated under an equivalent, limited budget of gradient steps, competing flow-specific networks degrade significantly. In contrast, FlowMoDL robustly converges and strictly outperforms all competitors across all acceleration factors in magnitude SSIM, nRMSE, relative velocity error, and angular error, successfully recovering sharp structural details and temporally coherent velocity fields.

0.09

STAIRS: Staging the Inverse Problem via Admissible-Support Scheduling for Unrolled MRI Reconstruction

cs.CV ·2026-11-06 ·Xiangjian Hou, Chang Ni, Chao Qin, Zhiwei Tan, Xin Wang +4 more
similarity 0.67
Abstract

Accelerated magnetic resonance imaging (MRI) forms images from incomplete Fourier measurements, shifting acquisition burden to computational reconstruction. Deep unrolled networks interleave learned regularization and data consistency, yet typically estimate the full unmeasured spectrum at every cascade. We propose STAIRS (Staging the Inverse Problem via Admissible-Support Scheduling), which projects intermediate reconstructions onto nested Fourier supports that expand to the full spectrum and conditions each update on its support transition. Conditional increments of a regularized log-determinant score of training covariance define a normalized spectral coordinate, accounting for dependencies between newly and previously admitted frequencies. Dyadic targets allocate larger coordinate increments to earlier cascades and are mapped to fixed supports before training, enabling coarse-to-fine reconstruction with unchanged sampling masks and data consistency. On fastMRI and Stanford2D, STAIRS improves matched Transformer (HUMUSNet) and convolutional (NAFNet) backbones in single- and multi-coil reconstruction, including radiologist-annotated pathology regions. It also outperforms predictor-based progression with lower parameter overhead and inference latency. Stage-wise analysis shows repeated error correction by projection and lower intermediate reconstruction errors than the backbones alone throughout support expansion. Ablations favor dyadic allocation over uniform expansion for square and line-band supports and over manual front-loading for square windows. Support projection alone improves reconstruction, and transition conditioning strengthens the gain. Cross-dataset evaluation shows improvements for both backbones in both directions. Support allocation thus complements regularizer design in unrolled MRI reconstruction.

0.22