CS Paper Radar

From Slices to Volumes: Comparing 2D, 2.5D, and 3D Residual Networks for Pulmonary Nodule Malignancy-Risk Classification

Bahodir Nazarov, Zineb Gharib, Fatima Zazoul

cs.LG cs.CV ·submitted 2026-10-25 10:03 UTC · v1
code/data

Abstract

Purpose: To compare 2D, 2.5D, and 3D residual networks for pulmonary nodule malignancy-risk classification and evaluate momentum-contrast pretraining, mild augmentation, and exclusion of indeterminate ratings. Methods: A retrospectively prepared LIDC-IDRI cohort contained 2,654 nodules labeled benign, indeterminate, or malignant using median radiologist ratings. Patient-disjoint splits comprised 1,876 training, 382 validation, and 396 test nodules. Representations included one axial slice, five neighboring slices, and a local CT volume. Each track evaluated a randomly initialized baseline, momentum-contrast pretraining followed by fine-tuning, and supervised training with mild augmentation. Checkpoints were selected by validation Macro-F1. The 2D experiments used three seeds; 2.5D and 3D results were single-run estimates. A separate binary experiment excluded indeterminate nodules. Results: Augmented models achieved test Macro-F1 values of $0.6134\pm0.0075$ for 2D, $0.6537$ for 2.5D, and $0.5403$ for 3D; the 2D uncertainty denotes population standard deviation across seeds. Corresponding accuracies were $0.6128$, $0.6869$, and $0.5455$. Augmentation improved Macro-F1 within every track, whereas the tested pretraining recipes reduced it. Binary Macro-F1 values were $0.8227$, $0.8664$, and $0.7554$, respectively. Conclusion: Augmented 2.5D achieved the highest observed performance. Differences in preprocessing, optimization, capacity, and replication limit attribution to dimensionality. Labels reflect radiologist-assessed malignancy risk rather than pathology-confirmed cancer. Code and experimental results are available at https://github.com/CT-DeepLearning-Team/CT-2D-2.5D-3D-DeepLearning.

Closest papers

Nearest neighbours by meaning across the whole index.

Evaluating Multi-Task Morphological Concept Learning for Pulmonary Nodule Malignancy Assessment in 3D CT

cs.CV ·2026-09-29 ·Namitha Narayanan
similarity 0.74
Abstract · 8 pages, 3 figures, 5 tables

Morphological characteristics such as spiculation and lobulation play an important role in assessing pulmonary nodules on computed tomography (CT), particularly in relation to malignancy risk. This study examines whether learning radiologist-annotated morphological features together with malignancy risk from lesion-centred 3D CT volumes improves classification performance. The Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI) dataset was used, comprising 3,918 reader-level nodule annotations from 742 patients after excluding indeterminate malignancy ratings. Patient-level splitting was used for training, validation, and testing, with 112 patients and 628 reader annotations in the held-out test set. A single-task 3D convolutional neural network was compared with a multi-task model predicting malignancy risk, spiculation, and lobulation. The single-task model achieved a balanced accuracy of 0.548 and receiver operating characteristic area under the curve (ROC-AUC) of 0.552, while the multi-task model achieved 0.539 and 0.558, respectively. Patient-level bootstrap analysis showed an ROC-AUC difference of 0.005 (95% confidence interval (CI): -0.087 to 0.090) and a balanced-accuracy difference of -0.009 (95% CI: -0.067 to 0.043). The auxiliary tasks were strongly imbalanced and showed limited predictive performance. Overall, including morphological features did not clearly improve malignancy-risk classification, showing the importance of class balance, label formulation, and reader-level annotation structure in multi-task pulmonary CT analysis.

0.15

Can Unsupervised Methods Outperform Supervised Deep Learning When Ground Truth Is Sparse? A Case Study of Bronchovascular Bundle Segmentation in Low-Dose CT

cs.CV ·2026-08-17 ·Anna Mrukwa, Marek Socha, Aleksandra Suwalska, Agata Durawa, Malgorzata Jelitto +7 more
similarity 0.70
Abstract · 17 pages, 4 figures. Part of this research was submitted to the international conference European Molecular Imaging Meeting 2026

Background Lung cancer remains the deadliest cancer worldwide because it is often diagnosed too late. Effective treatment depends on detection at an early screening stage. However, the growing number of patients and the limited number of radiologists lead to prolonged diagnostic waiting times. In very early stage lung cancer, nodule visibility is further reduced by adjacent blood vessels and airway walls, because nodules are often connected to or supplied by these structures. Task-specific analysis of the bronchovascular bundle is therefore important for efficient nodule detection, and its removal can increase the diagnostic potential of lung cancer screening. Materials and Methods To assess the efficacy of the proposed method, we used series from widely utilized LDCT datasets, including the Duke Lung Cancer Screening (DLCS) dataset and the Pilot Pomeranian Lung Cancer Screening Program. The proposed bronchovascular bundle segmentation pipeline, RONALD, operates on computed tomography images and returns binary masks of vessels and bronchi located in the lung parenchyma. The method includes a preprocessing stage with lung, lobe, and mediastinum segmentation, followed by separate vessel and bronchial tree segmentation. Results The proposed pipeline segmented the bronchovascular bundle in low-dose computed tomography scans while improving nodule retention compared with other segmentation methods: from 93.98% and 90.36% to 100% in DLCS, and from 83.16% and 62.36% to 99.92% in the Pomeranian dataset. Conclusion The resulting segmentations can improve lung nodule detection in the very early stages of lung cancer.

0.12

NoduleFlow: Automatic 3D Lung Nodule Detection and Segmentation

cs.CV ·2026-10-12 ·Giulia Romoli, Filippo Ruffini, Francesco Di Feola, Valerio Guarrasi, Matteo Tortora +1 more
similarity 0.69
Abstract

Low dose Computed Tomography (CT) is the standard imaging modality for lung cancer screening. On CT scans, lung cancer typically manifests as pulmonary nodules, whose manual identification is time-consuming and prone to observer variability, image quality limitations, and suboptimal reading conditions. Moreover, subtle temporal changes are often difficult to quantify reliably in CT scans from the same patient across follow-up examinations. Deep learning-based approaches for the automatic detection and segmentation of lung nodules have demonstrated improved accuracy and efficiency. However, most existing approaches provide only coarse region-of-interest localisation, rely on prior lesion annotations or human supervision, or treat detection and segmentation as separate tasks. In this work, we present NoduleFlow, a framework for lung nodule detection, classification, and segmentation directly from series of CT volumes. Our proposal consists of four interconnected modules and operates in an automated manner at inference time, without requiring prior lesion annotations, manual initialisation, or region-of-interest pre-selection. We further investigate whether nodule localization benefits from the propagation of candidate regions across follow-up scans through inter-scan registration fields, as opposed to conventional independent per-scan analysis. The generalisability of the framework is systematically evaluated across four independent datasets. The results underscore the potential of automated pipelines for lung nodule analysis in screening and diagnostic settings.

0.14

LeCor: Learning to Be Corrected by Meta-Learned Test-Time Training for Interactive 3D Lung-Tumour Segmentation

cs.CV cs.LG ·2026-09-08 ·Yi Luo, Yike Guo, Wenxuan Li, Zongwei Zhou, Rui Zhang +1 more
similarity 0.67
Abstract · 18 pages, 4 figures

Delineating lung tumours on computed tomography (CT) takes a considerable share of the time spent on radiotherapy planning, and a contour proposed by a model can be refined interactively by the clinician. Promptable foundation models such as SAM 3 support this workflow by writing each correction into a session memory that conditions the remaining slices, while the model weights stay fixed. On 690 test cases from five public CT cohorts, fine-tuning SAM 3 on lung tumours raises the Dice obtained from a single point prompt from 0.298 to 0.757, and seven rounds of corrections raise it further to 0.765, but under memory conditioning alone the accuracy on slices the annotator has not touched stops improving after six rounds. We therefore treat each correction as a training signal and propose LeCor, which performs test-time training on a small set of case adapters that are reset for every case and meta-learned such that a single gradient step driven by a click improves the slices that were not clicked. On the 133 test cases that span at least eight slices, LeCor raises the Dice reached after seven correction rounds from 0.787 with the fine-tuned model to 0.827, reduces the number of cases that never reach a Dice of 0.80 from 47 to 27, and reaches in three correction rounds the accuracy that the fine-tuned model attains in seven.

0.21

GRIPNet: Gaussian Radial Intensity Prior Guided Architecture for Pulmonary Nodule Detection in CT

cs.CV cs.AI ·2026-09-10 ·Haojie Yang, Ran Su
similarity 0.66
Abstract

Lung cancer causes more deaths than any other malignancy, and low-dose CT screening is the main pathway to early diagnosis. That pathway hinges on the smallest lesions, yet nodules below six millimeters remain hard to detect, because most methods treat a nodule as a generic object and ignore the imaging physics behind its appearance. We show that this appearance is highly regular. Intensity peaks at the geometric center of a nodule and decays radially in a Gaussian pattern, and a fit to 18,218 annotated lesions from three public benchmarks yields a mean radial coefficient of determination above 0.86 in every dataset and size stratum. A square convolution samples both axes uniformly and is mismatched to this radial signal, most severely for small nodules. Guided by this evidence, we propose GRIPNet (Gaussian Radial Intensity Prior Network), a detector in which every module maps to a measurable property of the intensity distribution. Pinwheel convolutions decompose radial gradients, a dual-frequency module separates boundary detail from structural context, dilated masked attention matches the decay extent, and an adaptive loss reweights samples by conspicuity. GRIPNet raises mAP@0.5 to 95.3, 91.6 and 97.9 percent on KanserSet, LUNA16 and Lung-PET-CT-Dx while sharpening high-IoU localization at real-time speed.

0.12

LUCQUE: A lung cancer screening dataset from Québec for reliable AI evaluation

cs.DB cs.AI ·2026-11-09 ·Johanna Topalis, Yannick Lemaréchal, Gabriel Couture, Hanife Ersay, Loran Nas +5 more
similarity 0.65
Abstract

BACKGROUND: AI-based tools are expected to play a key role in lung cancer screening (LCS). The evaluation of these tools often relied on private datasets or fragmented public datasets with inconsistent availability of clinical data and expert nodule annotations. This has hindered reproducibility, comparability, and independent assessment of AI tools. To address these gaps, we present LUCQUE, a novel, large, comprehensively annotated dataset derived from LDCT lung cancer screening in Québec, which is accessible for reliable AI evaluation. METHODS: LUCQUE was curated and is hosted on PARADIM, a digital infrastructure supporting DICOM data de-identification, annotation, long-term storage and analysis. LDCT scans and clinical information were combined to a curated collection and complemented by voxel-level, expert-derived pulmonary nodule and cyst segmentations, and Lung-RADS-based lesion characteristics. Key dataset characteristics and statistics were reported, including participant demographics, imaging parameters, radiological findings, and segmented lesion characteristics. Dataset analyses were conducted according to PARADIM's model-to-data approach, in which user code is executed on the platform such that data remains on premise. RESULTS: LUCQUE currently comprises 1,678 LDCT baseline studies from 1,678 participants. Most studies were classified as Lung-RADS 2. A total of 1,776 pulmonary nodules and 60 cysts were annotated, with a median (interquartile range) volume of $89\,(56,\,159)\,\mathrm{mm}^3$ and $1,384\,(589,\,3793)\,\mathrm{mm}^3$ respectively. CONCLUSIONS: Compared to publicly available LCS datasets, LUCQUE currently represents the largest accessible annotated real-world LCS dataset. Access to LUCQUE is provided via a model-to-data approach, enabling privacy-preserving, reproducible, and independent real-world evaluation of AI tools in LCS.

0.20

FZ-VLM: A Two Stage Florence-Zephyr Vision Language Model Framework for Pulmonary Nodule Characterization and Clinical Decision Making

cs.CV cs.AI ·2026-08-15 ·Pramit Dutta, Jenita Manokaran, Richa Mittal, Ryan Appleby, Eranga Ukwatta
similarity 0.64
Abstract

Lung cancer remains one of the leading causes of cancer-related mortality worldwide, and Computed Tomography (CT) is a primary imaging tool for screening and followup assessment. After pulmonary nodule detection, radiologists manually assess anatomical location, diameter, margin characteristics, and attenuation type to support risk assessment and clinical decision-making. However, this post-detection workflow is time-consuming and can be affected by inter-observer variability. Existing Artificial Intelligence methods often focus on isolated tasks, limiting their use as a unified, clinically grounded interpretation framework. This study presents FZ-VLM, a two-stage Florence-Zephyr Vision Language Model framework for unified structured pulmonary nodule characterization in lung CT. The framework uses a fine-tuned Florence-2 model to extract radiological attributes from expert-annotated 2D axial CT slices, while a Zephyr-7B model uses these attributes to generate nodule descriptions, follow-up recommendations, and longitudinal analyses. Results showed that the Stage 1 model achieved 77.18\% accuracy for anatomical location, 67.96\% accuracy for margin characteristics, and 79.13\% accuracy for attenuation type, with a Mean Absolute Error of 2.58 mm for diameter estimation, outperforming evaluated GPT-4-based baselines as well as the human baseline. Expert radiologist evaluation of Stage 2 showed 93.9\% accuracy, 98.6\% completeness score, 76.1\% clinical relevance, and an overall score of 89.5\%. Safety analysis showed that most outputs were clinically safe, although some follow-up recommendations still required expert review. To the best of our knowledge, this study presents the first two-stage Vision-Language Model framework for structured nodule characterization and clinical decision-making.

0.04

Disentangling Lung-Cancer CT/LDCT AI: A Systematic Evidence Map of Clinical Tasks, Evidence Chains, and Translational Gaps

cs.LG ·2026-09-28 ·Surajit Das
similarity 0.64
Abstract

Artificial-intelligence studies using computed tomography (CT) for lung cancer are often broadly labelled "prediction" despite addressing clinically distinct tasks. We systematically mapped CT/low-dose CT (LDCT)-centered lung-cancer AI using five-database retrieval, full-text eligibility assessment, role-aware modality/omics extraction, clinical-task classification, and a Multi-Tier Evidence Graph (MTEG). The final corpus comprised 293 studies (2016-2026): 230 Detection, 8 future Risk-prediction, and 55 Other studies. Clinical variables (96.2%), 3D CT/LDCT (73.0%), and radiomics (63.5%) predominated, whereas external validation (29.0%), calibration (20.5%), decision-curve analysis (13.0%), longitudinal CT (17.7%), and saliency/attribution XAI (21.5%) were less frequent. The MTEG comprised 377 nodes and 3,444 edges; only 31 studies (10.6%) completed the six-tier substantive evidence chain, with greatest attrition at reasoning/explanation. Overall, the literature is detection-dominated, genuine future risk prediction remains uncommon, and complete translational evidence chains are rare.

0.08