CS Paper Radar

GRIPNet: Gaussian Radial Intensity Prior Guided Architecture for Pulmonary Nodule Detection in CT

Haojie Yang, Ran Su

cs.CV cs.AI ·submitted 2026-09-10 09:38 UTC · v1

Abstract

Lung cancer causes more deaths than any other malignancy, and low-dose CT screening is the main pathway to early diagnosis. That pathway hinges on the smallest lesions, yet nodules below six millimeters remain hard to detect, because most methods treat a nodule as a generic object and ignore the imaging physics behind its appearance. We show that this appearance is highly regular. Intensity peaks at the geometric center of a nodule and decays radially in a Gaussian pattern, and a fit to 18,218 annotated lesions from three public benchmarks yields a mean radial coefficient of determination above 0.86 in every dataset and size stratum. A square convolution samples both axes uniformly and is mismatched to this radial signal, most severely for small nodules. Guided by this evidence, we propose GRIPNet (Gaussian Radial Intensity Prior Network), a detector in which every module maps to a measurable property of the intensity distribution. Pinwheel convolutions decompose radial gradients, a dual-frequency module separates boundary detail from structural context, dilated masked attention matches the decay extent, and an adaptive loss reweights samples by conspicuity. GRIPNet raises mAP@0.5 to 95.3, 91.6 and 97.9 percent on KanserSet, LUNA16 and Lung-PET-CT-Dx while sharpening high-IoU localization at real-time speed.

Closest papers

Nearest neighbours by meaning across the whole index.

NoduleFlow: Automatic 3D Lung Nodule Detection and Segmentation

cs.CV ·2026-10-12 ·Giulia Romoli, Filippo Ruffini, Francesco Di Feola, Valerio Guarrasi, Matteo Tortora +1 more
similarity 0.74
Abstract

Low dose Computed Tomography (CT) is the standard imaging modality for lung cancer screening. On CT scans, lung cancer typically manifests as pulmonary nodules, whose manual identification is time-consuming and prone to observer variability, image quality limitations, and suboptimal reading conditions. Moreover, subtle temporal changes are often difficult to quantify reliably in CT scans from the same patient across follow-up examinations. Deep learning-based approaches for the automatic detection and segmentation of lung nodules have demonstrated improved accuracy and efficiency. However, most existing approaches provide only coarse region-of-interest localisation, rely on prior lesion annotations or human supervision, or treat detection and segmentation as separate tasks. In this work, we present NoduleFlow, a framework for lung nodule detection, classification, and segmentation directly from series of CT volumes. Our proposal consists of four interconnected modules and operates in an automated manner at inference time, without requiring prior lesion annotations, manual initialisation, or region-of-interest pre-selection. We further investigate whether nodule localization benefits from the propagation of candidate regions across follow-up scans through inter-scan registration fields, as opposed to conventional independent per-scan analysis. The generalisability of the framework is systematically evaluated across four independent datasets. The results underscore the potential of automated pipelines for lung nodule analysis in screening and diagnostic settings.

0.14

Can Unsupervised Methods Outperform Supervised Deep Learning When Ground Truth Is Sparse? A Case Study of Bronchovascular Bundle Segmentation in Low-Dose CT

cs.CV ·2026-08-17 ·Anna Mrukwa, Marek Socha, Aleksandra Suwalska, Agata Durawa, Malgorzata Jelitto +7 more
similarity 0.69
Abstract · 17 pages, 4 figures. Part of this research was submitted to the international conference European Molecular Imaging Meeting 2026

Background Lung cancer remains the deadliest cancer worldwide because it is often diagnosed too late. Effective treatment depends on detection at an early screening stage. However, the growing number of patients and the limited number of radiologists lead to prolonged diagnostic waiting times. In very early stage lung cancer, nodule visibility is further reduced by adjacent blood vessels and airway walls, because nodules are often connected to or supplied by these structures. Task-specific analysis of the bronchovascular bundle is therefore important for efficient nodule detection, and its removal can increase the diagnostic potential of lung cancer screening. Materials and Methods To assess the efficacy of the proposed method, we used series from widely utilized LDCT datasets, including the Duke Lung Cancer Screening (DLCS) dataset and the Pilot Pomeranian Lung Cancer Screening Program. The proposed bronchovascular bundle segmentation pipeline, RONALD, operates on computed tomography images and returns binary masks of vessels and bronchi located in the lung parenchyma. The method includes a preprocessing stage with lung, lobe, and mediastinum segmentation, followed by separate vessel and bronchial tree segmentation. Results The proposed pipeline segmented the bronchovascular bundle in low-dose computed tomography scans while improving nodule retention compared with other segmentation methods: from 93.98% and 90.36% to 100% in DLCS, and from 83.16% and 62.36% to 99.92% in the Pomeranian dataset. Conclusion The resulting segmentations can improve lung nodule detection in the very early stages of lung cancer.

0.12

From Slices to Volumes: Comparing 2D, 2.5D, and 3D Residual Networks for Pulmonary Nodule Malignancy-Risk Classification

cs.LG cs.CV ·2026-10-25 ·Bahodir Nazarov, Zineb Gharib, Fatima Zazoul
code/data similarity 0.66
Abstract

Purpose: To compare 2D, 2.5D, and 3D residual networks for pulmonary nodule malignancy-risk classification and evaluate momentum-contrast pretraining, mild augmentation, and exclusion of indeterminate ratings. Methods: A retrospectively prepared LIDC-IDRI cohort contained 2,654 nodules labeled benign, indeterminate, or malignant using median radiologist ratings. Patient-disjoint splits comprised 1,876 training, 382 validation, and 396 test nodules. Representations included one axial slice, five neighboring slices, and a local CT volume. Each track evaluated a randomly initialized baseline, momentum-contrast pretraining followed by fine-tuning, and supervised training with mild augmentation. Checkpoints were selected by validation Macro-F1. The 2D experiments used three seeds; 2.5D and 3D results were single-run estimates. A separate binary experiment excluded indeterminate nodules. Results: Augmented models achieved test Macro-F1 values of $0.6134\pm0.0075$ for 2D, $0.6537$ for 2.5D, and $0.5403$ for 3D; the 2D uncertainty denotes population standard deviation across seeds. Corresponding accuracies were $0.6128$, $0.6869$, and $0.5455$. Augmentation improved Macro-F1 within every track, whereas the tested pretraining recipes reduced it. Binary Macro-F1 values were $0.8227$, $0.8664$, and $0.7554$, respectively. Conclusion: Augmented 2.5D achieved the highest observed performance. Differences in preprocessing, optimization, capacity, and replication limit attribution to dimensionality. Labels reflect radiologist-assessed malignancy risk rather than pathology-confirmed cancer. Code and experimental results are available at https://github.com/CT-DeepLearning-Team/CT-2D-2.5D-3D-DeepLearning.

0.18

TRIUNE-Net: Harmonizing Scale, Shape, and Efficiency in Pancreatic Tumor Segmentation

cs.CV ·2026-09-08 ·Amir Hossein Saleknia, Alireza Kheyrkhah, Sanaz Karimijafarbigloo, Reza Azad, Sina Houshmand +3 more
code/data similarity 0.64
Abstract

Pancreatic tumor segmentation in 3D CT volumes is challenged by extreme scale variability across both the pancreas and tumor, and highly irregular tumor morphology. While recent advances have pushed segmentation performance, existing methods do not explicitly address these challenges and come at the cost of excessive computational complexity, limiting their practicality in resource-constrained clinical environments. We propose TRIUNE-Net, a lightweight unified architecture that harmonizes scale, shape, and efficiency through three synergistic innovations. A multi-scale context aggregation module with stage-adaptive dilated convolutions enables the model to reason across the broad range of anatomical scales present in both organs. A serial linear-deformable attention mechanism combines large effective receptive fields with shapeadaptive deformable convolutions to capture irregular, non-convex tumor morphologies. Finally, an information-preserving downsampling module replaces conventional max pooling entirely, retaining all spatial information while adding negligible parameters, preventing small tumors from being discarded before they can be recognized. On both the MSD Pancreas and NVD Pancreas datasets, TRIUNE-Net achieves state-of-theart results with only 5.86 M parameters and no external pre-training, outperforming all baselines across all key tumor metrics. Specifically, it surpasses the next-best model by 0.45% in tumor Dice, 6.0 points in F1 score, 6.6 points in sensitivity, and 3.4 points in precision, simultaneously reflecting its ability to suppress both missed tumors and false alarms in clinically realistic conditions. Our code is available at: https://github.com/abdora-ai/TRIUNE-Net

0.30

Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising

eess.IV ·2026-09-30 ·Ping Wu, Pengcheng Zheng, Jiahao Zhang, Bohao Chen, Yazhou Ren +1 more
similarity 0.63
Abstract · 10 pages

Low-dose CT (LDCT) reduces radiation exposure but often introduces severe noise and streak artifacts that obscure subtle anatomical structures. Existing diffusion-based denoising methods commonly rely on implicit assumptions about the noise distribution, which may not hold in practical LDCT scenarios and can degrade denoising performance. To address this limitation, we propose a Residual-Guided Diffusion framework that effectively incorporates an explicit difference prior to inform the diffusion process of noise distribution. The difference prior is computed as the residual between the LDCT image and a coarse clean estimate, constraining diffusion sampling to a plausible residual space. We further adopt a coarse-to-fine strategy in which a pre-trained RED-CNN provides the coarse estimate to anchor global anatomy, and the diffusion model refines the remaining details under the prior guidance. For efficiency, we employ accelerated sampling with 20 steps at inference. Experiments on three representative datasets demonstrate that our approach outperforms existing methods in both quantitative and qualitative performance measures.

0.14

Comprehensive Benchmarking of Deep Learning Architectures for Lung Cancer Histopathology

cs.CV cs.AI ·2026-08-16 ·Hadi Hasan, Safaa Salman, Lama Sleem, Ralph Mouawad, Ali Chehab
benchmark similarity 0.62
Abstract · 8 pages

Lung cancer remains the leading cause of cancer-related mortality worldwide, while histopathological diagnosis is often affected by inter-observer variability and the substantial workload associated with manual slide examination. Although deep learning has shown considerable potential in computational pathology, comprehensive benchmarks that integrate tissue classification and region segmentation within a unified analytical framework remain limited. This study presents a two-stage deep learning framework for multi-class tissue classification and pixel-level histopathological region segmentation, accompanied by a systematic comparison of state-of-the-art architectures at each stage. For tissue classification, six models, a custom convolutional neural network, VGG16, DenseNet, MobileNetV3, a custom Vision Transformer, and YOLO11, are evaluated on a combined dataset of 39,000 images derived from LC25000 and LungHist700. The models distinguish between adenocarcinoma, squamous cell carcinoma, and normal lung tissue. YOLO11 achieves the best classification performance, with an accuracy of 98.38%, a five-fold cross-validation accuracy of 98.21 +/- 0.35%, and a macro F1-score of 0.98. For region segmentation, U-Net, ResNet-encoder U-Net, DeepLabV3+, and YOLO11-seg are evaluated using the GlaS gland segmentation benchmark. DeepLabV3+ obtains the highest Intersection over Union of 0.80 and a Dice score of 0.89, while YOLO11-seg achieves a comparable Intersection over Union of 0.79 using approximately 14x fewer parameters. The best-performing classification and segmentation models are subsequently integrated into an end-to-end framework, providing an accurate, computationally efficient, and reproducible baseline for automated histopathological image analysis.

0.40

Annotating anatomy and pathology in the National Lung Screening Trial computed tomography images

eess.IV ·2026-09-09 ·Deepa Krishnaswamy, Vamsi Thiriveedhi, Suraj Pai, David Clunie, Igor Octaviano +4 more
similarity 0.62
Abstract

Large-scale public medical imaging datasets contribute critically to translational research. When accompanied by rich clinical and multi-omics data, they can stimulate exploratory research and enable secondary analyses. Expert annotations of such imaging collections can support the development of new image analysis tools. Continuous enrichment of images with image-derived data makes them more usable for researchers without expertise in image analysis or access to large-scale computational resources. The National Lung Screening Trial (NLST) released a rich longitudinal dataset that includes Computed Tomography (CT) images for over 26,000 patients. We introduce three Digital Imaging and Communications in Medicine (DICOM) formatted datasets, complementing NLST CT images, shared as analysis results in the National Cancer Institute Imaging Data Commons (IDC). Two of those (IDC NLSTSeg and IDC NLSTSybil) contain DICOM-harmonized annotations and extracted measurements (for 581 and 601 NLST patients, respectively) shared earlier using research formats (Sybil and NLSTseg). The third one (TotalSegmentator-CT-Segmentations) contains volumetric segmentations generated using TotalSegmentator and radiomics features for each segment for 26,194 NLST patients.

0.18

Feed-Forward Hierarchical Gaussian Diffusion for Extreme CT Reconstruction

cs.CV ·2026-08-15 ·Yuezhe Yang, Li Cheng
benchmarkcode/data similarity 0.61
Abstract

Reconstructing three-dimensional computed tomography (CT) from severely constrained projections is highly ill-posed. Sparse angular sampling, restricted angular coverage, and low photon counts can occur individually or jointly, obscuring global anatomy and local tissue detail. Many learned CT reconstruction methods are tailored to a single dominant degradation. Existing diffusion and Gaussian approaches commonly recover global structure and local detail within a shared representation. We propose HiGDiff, a feed-forward hierarchical Gaussian diffusion framework that decomposes reconstruction both spatially and from structure to detail. Physics-conditioned anatomical anchors and a foreground capacity field allocate learnable Gaussian primitives to informative regions. A structure diffusion stage first recovers global attenuation geometry, and its learned representation conditions a detail diffusion stage for residual boundaries and tissue transitions. The resulting Gaussian banks are rendered as attenuation fields and further refined by a gradient-isolated residual module. Experiments on three distinct CT benchmark datasets demonstrate state-of-the-art reconstruction performance across isolated, paired, and joint degradation settings, including improvements of 5.81 dB in macro-average peak signal-to-noise ratio (PSNR) and 0.113 in structural similarity index measure (SSIM) on the Low Dose CT Image and Projection Data (LDCT-PD) collection. Code and experimental configurations are openly available at https://github.com/Bean-Young/HiGDiff.

0.24