CS Paper Radar

Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising

Ping Wu, Pengcheng Zheng, Jiahao Zhang, Bohao Chen, Yazhou Ren, Xiaorong Pu

eess.IV ·submitted 2026-09-30 07:32 UTC · v1

Abstract

Low-dose CT (LDCT) reduces radiation exposure but often introduces severe noise and streak artifacts that obscure subtle anatomical structures. Existing diffusion-based denoising methods commonly rely on implicit assumptions about the noise distribution, which may not hold in practical LDCT scenarios and can degrade denoising performance. To address this limitation, we propose a Residual-Guided Diffusion framework that effectively incorporates an explicit difference prior to inform the diffusion process of noise distribution. The difference prior is computed as the residual between the LDCT image and a coarse clean estimate, constraining diffusion sampling to a plausible residual space. We further adopt a coarse-to-fine strategy in which a pre-trained RED-CNN provides the coarse estimate to anchor global anatomy, and the diffusion model refines the remaining details under the prior guidance. For efficiency, we employ accelerated sampling with 20 steps at inference. Experiments on three representative datasets demonstrate that our approach outperforms existing methods in both quantitative and qualitative performance measures.

Comment
10 pages

Closest papers

Nearest neighbours by meaning across the whole index.

Noise2Match: Self-Supervised Low-Dose CT Denoising via Adaptive Inter-Slice Matching

cs.CV ·2026-10-13 ·Langrui Zhou, Guang Li, Xinyu Huang, Ziteng Zhou, Zuyang Huang +3 more
top venue similarity 0.75
Abstract

With the rapid development of deep learning, supervised convolutional neural network methods have greatly improved the performance of low-dose computed tomography (CT) denoising. However, they require paired noisy-clean training data, which is difficult to obtain in practice. Some classic self-supervised denoising methods rely on the assumption of pixel-wise independent noise, making them ineffective for correlated noise in low-dose CT (LDCT) images. Considering the high similarity and weaker noise correlation between adjacent CT slices, several recently proposed self-supervised methods use adjacent LDCT slices for training. Nevertheless, these approaches fail to effectively account for the non-rigid misalignment between slices caused by anatomical variation, hindering them from satisfying the equal-mean condition required by the classic Noise2Noise framework. In this paper, we propose Noise2Match, a self-supervised LDCT denoising method based on adaptive inter-slice matching. Noise2Match introduces an inter-slice matching network to model the label transition process between adjacent slices, and then applies correction to the denoiser's outputs to better satisfy the equal-mean condition. We theoretically prove that, under idealized conditions, training Noise2Match using adjacent LDCT slices is equivalent to supervised training with paired noisy-clean images. We further find that Noise2Match can also effectively perform low-dose conebeam CT (CBCT) denoising, which could be attributed to its correction operation that reduces inter-slice noise correlation. To the best of our knowledge, Noise2Match is the first effective image-domain self-supervised method for low-dose CBCT. Extensive experiments demonstrate that Noise2Match outperforms existing image-domain selfsupervised methods, offering broader applicability and higher practical value.

0.33

Fast Self-Supervised Generative CT Denoising via Few-Step Sampling

cs.CV ·2026-11-19 ·Xingyi Yao, Zhengtao Ma, Zhennong Chen
similarity 0.75
Abstract · 30 pages, 4 figures, 2 tables. Xingyi Yao and Zhengtao Ma contributed equally to this work. Zhennong Chen is the corresponding author

Low-dose and thin-slice computed tomography (CT) images suffer from elevated noise that obscures anatomical detail, while clean references for supervised denoising are often unavailable. Although Noise2Noise permits self-supervised training from noisy pairs, direct regression tends to oversmooth fine structure. Averaging multiple independently generated samples mitigates this blur, though repeating multi-step diffusion sampling is costly. We introduce Noise2Noise with Improved Mean Flow (N2N-iMF) to accelerate this process via few-step sampling. N2N-iMF learns to generate one noisy image conditioned on its paired counterpart; at inference, independent outputs are sampled and averaged to suppress noise. We evaluated image quality and sampling efficiency on simulated thin-slice brain and low-dose abdominal CT across four sampling methods and averaging counts from 1 to 20, and validated the approach on real-world photon-counting CT (PCCT) brain scans. With ten samples per conditioning input and three network evaluations per sample, N2N-iMF achieved a mean absolute error of 2.60 HU on brain CT and 14.02 HU on abdominal CT, outperforming 50-evaluation denoising diffusion implicit model (DDIM) sampling (2.91 and 14.53 HU). On the same GPU, per-output generation time dropped from 7.29 to 0.43 s. Across eight PCCT cases, N2N-iMF reached a mean gray-white matter contrast-to-noise ratio of 1.341, versus 0.916 for Noise2Noise and 1.176 for DDIM. N2N-iMF accelerates self-supervised generative CT denoising without distillation while keeping the number of averaged outputs adjustable at inference.

0.24

RouteDiff: Low-Dose CT Denoising via Fidelity-Refinement Routing and Hypergraph State Regulation

eess.IV cs.CV ·2026-11-12 ·Xinyuan Wang, Ruili Li, Tianyang Li, Yan Li, Xuepeng Liu
similarity 0.73
Abstract · 16 pages, 10 figures, 7 tables. Submitted to Knowledge-Based Systems

Diffusion models have become a strong prior for low-dose computed tomography (LDCT) restoration. However, existing samplers apply one structure-detail trade-off to the whole image, set the restoration emphasis of each step by the timestep, and derive each next state recursively from the current one, carrying its errors forward. We propose RouteDiff, a state-aware dual-route diffusion framework that routes detail to where it can be trusted, regulates each reverse step by the state it has reached, and re-enters the trajectory from an anchored estimate. Fidelity-Refinement Routing (FRR) equips one shared U-Net with a conservative fidelity route and a detail-oriented refinement route, fuses them pixel-wise with a confidence map, and exposes their disagreement as route evidence. Hypergraph State Regulation (HSR) organizes the current features and this evidence into a state hypergraph, whose soft hyperedges group scattered regions in the same state. Its readout yields an ordered stage judgment that modulates the bottleneck, and its incidence guides feature interaction in the skip connections. Estimate-Anchored Re-entry (EAR) re-projects a route-aware anchor onto the trajectory at a fixed step and hands the new state back to HSR to be judged again. With the ten network evaluations of its baseline, RouteDiff achieves the best peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) on four datasets with inserted, real and simulated noise (40.95 dB and 95.13% on Mayo 2020; 45.18 dB and 97.23% on Mayo 2016). It also generalizes to unseen doses of real scans and yields the highest Dice (80.92%) in downstream segmentation.

0.13

Feed-Forward Hierarchical Gaussian Diffusion for Extreme CT Reconstruction

cs.CV ·2026-08-15 ·Yuezhe Yang, Li Cheng
benchmarkcode/data similarity 0.73
Abstract

Reconstructing three-dimensional computed tomography (CT) from severely constrained projections is highly ill-posed. Sparse angular sampling, restricted angular coverage, and low photon counts can occur individually or jointly, obscuring global anatomy and local tissue detail. Many learned CT reconstruction methods are tailored to a single dominant degradation. Existing diffusion and Gaussian approaches commonly recover global structure and local detail within a shared representation. We propose HiGDiff, a feed-forward hierarchical Gaussian diffusion framework that decomposes reconstruction both spatially and from structure to detail. Physics-conditioned anatomical anchors and a foreground capacity field allocate learnable Gaussian primitives to informative regions. A structure diffusion stage first recovers global attenuation geometry, and its learned representation conditions a detail diffusion stage for residual boundaries and tissue transitions. The resulting Gaussian banks are rendered as attenuation fields and further refined by a gradient-isolated residual module. Experiments on three distinct CT benchmark datasets demonstrate state-of-the-art reconstruction performance across isolated, paired, and joint degradation settings, including improvements of 5.81 dB in macro-average peak signal-to-noise ratio (PSNR) and 0.113 in structural similarity index measure (SSIM) on the Low Dose CT Image and Projection Data (LDCT-PD) collection. Code and experimental configurations are openly available at https://github.com/Bean-Young/HiGDiff.

0.24

Physics-Guided Flow Matching for CT Image Reconstruction

cs.AI cs.CV ·2026-08-28 ·Davide Evangelista
similarity 0.72
Abstract · 16 pages, 6 figures, 2 tables

Deep generative models have recently emerged as powerful priors for solving ill-posed inverse problems in CT, with diffusion-based approaches achieving state-of-the-art reconstruction performance. However, diffusion models typically rely on stochastic sampling procedures, long inference trajectories, and carefully tuned noise schedules, which can limit computational efficiency and numerical stability, especially at high spatial resolutions. In this work, we investigate Flow Matching as an alternative generative prior for CT reconstruction. We train a high-resolution Rectified Flow Matching model on 256x256 chest images from the Mayo Clinic Low-Dose CT dataset. To mitigate overfitting and limited anatomical variability, we employ a two-stage training strategy consisting of an initial phase with strong, anatomically informed data augmentation, followed by a fine-tuning phase with reduced or no augmentation to refine structural fidelity. The resulting model is capable of generating high-quality and anatomically coherent CT-like images, serving as a strong learned prior. We then evaluate multiple reconstruction methods specifically designed for Flow Matching models, including Plug-and-Play Flow, FlowDPS, Flower, and Flow-Priors (ICTM), and compare them against state-of-the-art diffusion-based reconstruction algorithms such as DDRM, DPS, and DiffPIR. Experimental results across several CT inverse problem settings show that Flow Matching-based approaches consistently outperform diffusion-based methods in terms of PSNR, SSIM, and perceptual quality, while requiring fewer sampling steps. Finally, we publicly release the trained Flow Matching model and accompanying code to facilitate reproducibility and future research. Overall, this work demonstrates that Flow Matching provides a stable, efficient, and effective alternative to diffusion models for high-resolution CT image reconstruction.

0.41

Cascaded Posterior Sampling With Diffusion Priors for highly Accelerated MRI

eess.IV ·2026-10-25 ·Jyothi Rikhab Chand, Sahil Murtaza, Patrick Nicholas Nowak, Mathews Jacob
similarity 0.72
Abstract

Diffusion models are powerful priors for inverse problems, including accelerated MRI. However, modeling the distribution of high-resolution images requires large networks with high computational cost. We propose a posterior sampling framework that uses cascaded diffusion models as multiscale priors. Conditioned on a coarse image, the distribution of fine-scale detail is local and well conditioned, and it can therefore be captured by a small network. Similarly, a small unconditional network is sufficient to represent low-resolution images, and it is used to recover the coarse image from the k-space center. This estimate then conditions the high-resolution prior, which is combined with all measurements to recover the final image. Both priors are trained on images alone, so they apply to any sampling pattern, and data consistency remains linear at every scale. In multi-coil brain MRI, the proposed method improves on the best single-scale diffusion baseline by 4-6 dB in PSNR at 15x acceleration, while each of its separately trained networks is about 10x smaller. The gain grows as the problem becomes more ill-posed, and ablations show that it arises from informative low-resolution conditioning.

0.06

Physics-Driven Independent Pair Generation for Iterative Self-Supervised Low-Dose CT Denoising

cs.CV ·2026-09-01 ·Xianlei Han, Shaoyu Wang, Jiancheng Fang, Weiwen Wu, Qiegen Liu
similarity 0.72
Abstract · 10 pages, 11 figures, 3 tables. Includes a 1-page appendix. Submitted to IEEE Transactions on Circuits and Systems for Video Technology

Low-dose computed tomography (LDCT) measurements contain mixed Poisson-Gaussian noise. However, most self-supervised methods rely on generic image statistics and do not explicitly model this noise, which may limit their ability to effectively suppress realistic LDCT noise. To address this issue, we propose a physics-driven framework with cross-domain iteration for self-supervised LDCT denoising. The proposed framework proceeds in three main steps. First, a learned sinogram prior and the LDCT noise model guide posterior inference of photon counts, enabling separation of the Poisson and Gaussian components. Second, the separated Poisson and Gaussian components are respectively processed by binomial thinning and Gaussian data thinning to construct two branches, and residual scaling matches each branch's noise level to that of the observation, yielding a training pair with approximately independent noise realizations from one low-dose measurement. Finally, the pair is used to train an image-domain network whose forward-projected outputs update the prior. Through cross-domain iteration, the prior and the training pair are progressively refined while maintaining consistency with CT acquisition physics. Experiments on simulated data from AAPM, LIDC-IDRI, and LoDoPaB-CT and on real LDCT data show consistent gains over the evaluated self-supervised baselines across dose levels, with performance comparable to the evaluated supervised baseline.

0.25

PhyDiCT: Plug-and-Play CT Reconstruction from Sparse X-Rays via Differentiable Rendering and Strong Priors

cs.CV ·2026-10-07 ·Weicheng Dai, Shantanu Ghosh, Kayhan Batmanghelich
top venuecode/data similarity 0.71
Abstract · Accepted at MICCAI 2026; to appear in LNCS 16888

Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric information. We propose PhyDiCT, a training-free framework that integrates a differentiable Physics-based forward model, grounded in the Beer-Lambert law, with a text-conditioned Diffusion as a strong prior to reconstruct 3D lung CT images. We refer to our approach as training-free since the prior model is used without fine-tuning, and our goal is to steer the denoising procedure to generate samples consistent with X-ray observations. We guide the diffusion generation using Split Gibbs sampling to jointly optimize for projection fidelity (reward) and consistency with prior knowledge. Also, we introduce a test-time refinement step that enhances image realism and anatomical coherence. We extensively evaluate our method on publicly available 3D CT datasets using both perceptual and semantic metrics, demonstrating that it surpasses existing plug-and-play diffusion and fully trained reconstruction approaches. Our findings highlight that combining a strong generative prior with the underlying physics of image formation substantially improves reconstruction quality, e.g., 7.5\% improvement on SSIM compared to full training methods. Code will be released at https://github.com/batmanlab/PhyDiCT.

0.44