CS Paper Radar

RouteDiff: Low-Dose CT Denoising via Fidelity-Refinement Routing and Hypergraph State Regulation

Xinyuan Wang, Ruili Li, Tianyang Li, Yan Li, Xuepeng Liu

eess.IV cs.CV ·submitted 2026-11-12 20:02 UTC · v1

Abstract

Diffusion models have become a strong prior for low-dose computed tomography (LDCT) restoration. However, existing samplers apply one structure-detail trade-off to the whole image, set the restoration emphasis of each step by the timestep, and derive each next state recursively from the current one, carrying its errors forward. We propose RouteDiff, a state-aware dual-route diffusion framework that routes detail to where it can be trusted, regulates each reverse step by the state it has reached, and re-enters the trajectory from an anchored estimate. Fidelity-Refinement Routing (FRR) equips one shared U-Net with a conservative fidelity route and a detail-oriented refinement route, fuses them pixel-wise with a confidence map, and exposes their disagreement as route evidence. Hypergraph State Regulation (HSR) organizes the current features and this evidence into a state hypergraph, whose soft hyperedges group scattered regions in the same state. Its readout yields an ordered stage judgment that modulates the bottleneck, and its incidence guides feature interaction in the skip connections. Estimate-Anchored Re-entry (EAR) re-projects a route-aware anchor onto the trajectory at a fixed step and hands the new state back to HSR to be judged again. With the ten network evaluations of its baseline, RouteDiff achieves the best peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) on four datasets with inserted, real and simulated noise (40.95 dB and 95.13% on Mayo 2020; 45.18 dB and 97.23% on Mayo 2016). It also generalizes to unseen doses of real scans and yields the highest Dice (80.92%) in downstream segmentation.

Comment
16 pages, 10 figures, 7 tables. Submitted to Knowledge-Based Systems

Closest papers

Nearest neighbours by meaning across the whole index.

Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising

eess.IV ·2026-09-30 ·Ping Wu, Pengcheng Zheng, Jiahao Zhang, Bohao Chen, Yazhou Ren +1 more
similarity 0.73
Abstract · 10 pages

Low-dose CT (LDCT) reduces radiation exposure but often introduces severe noise and streak artifacts that obscure subtle anatomical structures. Existing diffusion-based denoising methods commonly rely on implicit assumptions about the noise distribution, which may not hold in practical LDCT scenarios and can degrade denoising performance. To address this limitation, we propose a Residual-Guided Diffusion framework that effectively incorporates an explicit difference prior to inform the diffusion process of noise distribution. The difference prior is computed as the residual between the LDCT image and a coarse clean estimate, constraining diffusion sampling to a plausible residual space. We further adopt a coarse-to-fine strategy in which a pre-trained RED-CNN provides the coarse estimate to anchor global anatomy, and the diffusion model refines the remaining details under the prior guidance. For efficiency, we employ accelerated sampling with 20 steps at inference. Experiments on three representative datasets demonstrate that our approach outperforms existing methods in both quantitative and qualitative performance measures.

0.14

AgentCT: A Vision-Language Agent for Universal CT Imaging

cs.CV ·2026-11-08 ·Zhihao Chen, Qi Gao, Chuang Niu, Qiegen Liu, Yi Zhang +1 more
code/datahot direction similarity 0.67
Abstract · 14 pages, 5 figures

Computed tomography (CT) restoration methods often use a single network for low-dose CT (LDCT), sparse-view CT (SVCT), and metal artifact reduction (MAR), despite the distinct physics of these degradations. We propose AgentCT, a vision-language agent that identifies the degradation and routes images to task-specific restoration models. A LoRA-adapted Qwen3-VL-4B controller predicts degradation type and severity, selects a specialist, and reassesses the restored image. The LDCT specialist uses an image-domain diffusion model, whereas the SVCT and MAR specialists combine projection-domain correction, data consistency, differentiable filtered back-projection, and image refinement. We evaluated the controller and specialists separately on patient-disjoint Mayo 2020 abdominal CT data across three severity levels for each degradation. The controller achieved 95.7% accuracy for degradation type and 93.9% for severity, with a 100% JSON parse rate. Using ground-truth degradation labels for routing, AgentCT achieved an overall PSNR/SSIM of 46.18 dB/0.984, compared with 44.93 dB/0.976 for AMIR and 44.29 dB/0.979 for TAMP, and attained the highest PSNR in all nine settings. For SVCT, its dual-domain specialist achieved 46.04 dB with 4.2 million parameters, compared with 44.43 dB for single-task AMIR and 43.57 dB for all-in-one AMIR with 23.5 million parameters. These results support degradation-specific CT restoration with controller-based model selection; evaluation under automatic routing and on independent clinical data remains necessary. Code is available at https://github.com/hao1635/AgentCT.

0.42

MARR: Decoupling Policy, Execution, and Calibration for All-in-One Medical Image Restoration

cs.CV ·2026-09-06 ·Haobin Chen, Ao Chang, Heqin Zhu, Rundong Wang, Ting Liu +1 more
benchmarkcode/data similarity 0.64
Abstract · 8 pages, 4 figures, 2 tables

All-in-one medical image restoration seeks to recover heterogeneous clinical images with a single model, but PET, CT, and MRI differ substantially in degradation statistics, anatomical contrast, and output-space bias. A fully shared network can entangle modality-specific residual errors, whereas separate modality-specific networks sacrifice the practical advantages of unified deployment. We therefore recast all-in-one restoration as a question of where limited adaptation should be placed: policy selection, feature execution, or output calibration. We propose MARR, a compact restoration framework that constrains multi-modality adaptation into degradation-aware policy routing, modality-private residual execution, and image-domain residual correction without requiring degradation labels or separate modality-specific models. The policy branch forms a routing prompt from input statistics, latent content, and modality identity, and uses it only as a control signal. Prompt-gated modality-private adapters then perform lightweight residual refinement at intermediate decoder stages, while zero-initialized modality-specific output heads calibrate the final image-domain residual without perturbing the initial shared prediction. On an all-in-one PET, CT, and MRI restoration benchmark, MARR outperforms thirteen methods re-trained under the same protocol, achieving PSNR values of 37.34 dB, 33.85 dB, and 32.09 dB on PET, CT, and MRI, respectively, and the best modality-average PSNR of 34.43 dB. The code is publicly available at https://github.com/CHB-learner/MARR.

0.30

Physics-Guided Flow Matching for CT Image Reconstruction

cs.AI cs.CV ·2026-08-28 ·Davide Evangelista
similarity 0.64
Abstract · 16 pages, 6 figures, 2 tables

Deep generative models have recently emerged as powerful priors for solving ill-posed inverse problems in CT, with diffusion-based approaches achieving state-of-the-art reconstruction performance. However, diffusion models typically rely on stochastic sampling procedures, long inference trajectories, and carefully tuned noise schedules, which can limit computational efficiency and numerical stability, especially at high spatial resolutions. In this work, we investigate Flow Matching as an alternative generative prior for CT reconstruction. We train a high-resolution Rectified Flow Matching model on 256x256 chest images from the Mayo Clinic Low-Dose CT dataset. To mitigate overfitting and limited anatomical variability, we employ a two-stage training strategy consisting of an initial phase with strong, anatomically informed data augmentation, followed by a fine-tuning phase with reduced or no augmentation to refine structural fidelity. The resulting model is capable of generating high-quality and anatomically coherent CT-like images, serving as a strong learned prior. We then evaluate multiple reconstruction methods specifically designed for Flow Matching models, including Plug-and-Play Flow, FlowDPS, Flower, and Flow-Priors (ICTM), and compare them against state-of-the-art diffusion-based reconstruction algorithms such as DDRM, DPS, and DiffPIR. Experimental results across several CT inverse problem settings show that Flow Matching-based approaches consistently outperform diffusion-based methods in terms of PSNR, SSIM, and perceptual quality, while requiring fewer sampling steps. Finally, we publicly release the trained Flow Matching model and accompanying code to facilitate reproducibility and future research. Overall, this work demonstrates that Flow Matching provides a stable, efficient, and effective alternative to diffusion models for high-resolution CT image reconstruction.

0.42

Anatomy-preserving unpaired cone-beam CT refinement for image-guided radiotherapy using pseudo-label guided diffusion

cs.CV ·2026-10-05 ·Qi Lai, Yutong He
code/data similarity 0.64
Abstract

Cone-beam computed tomography (CBCT) is widely used in image-guided radiotherapy, but scatter, beam hardening, noise, truncation, and other artifacts limit image quality and CT number accuracy. Paired CBCT and CT data are difficult to obtain clinically because of motion, anatomical changes, and acquisition mismatch. We present RefineCBCT, an unpaired CBCT refinement framework that uses pseudo-label guidance and short-step diffusion to reduce artifacts while preserving patient-specific anatomy. RefineCBCT was trained and evaluated on unpaired CBCT and planning CT data from public LUNG TCIA and PELVIC TCIA datasets and compared with representative GAN and diffusion based methods. On LUNG TCIA, it achieved the best results across all metrics, with MAE 19.411, RMSE 62.758, PSNR 30.845 dB, and SSIM 0.931. On PELVIC TCIA, it achieved the best MAE, PSNR, and SSIM, with values of 14.905, 36.671 dB, and 0.876. The refined images showed fewer streaking and shading artifacts, clearer anatomical boundaries, and improved soft tissue uniformity, with line profile and ROI analyses showing closer agreement with planning CT. These results suggest that RefineCBCT provides efficient and effective CBCT refinement under clinically realistic unpaired training conditions and may support more reliable CBCT use in image-guided radiotherapy workflows. Code is publicly available on GitHub, and the evaluated datasets are available from The Cancer Imaging Archive.

0.21

Feed-Forward Hierarchical Gaussian Diffusion for Extreme CT Reconstruction

cs.CV ·2026-08-15 ·Yuezhe Yang, Li Cheng
benchmarkcode/data similarity 0.64
Abstract

Reconstructing three-dimensional computed tomography (CT) from severely constrained projections is highly ill-posed. Sparse angular sampling, restricted angular coverage, and low photon counts can occur individually or jointly, obscuring global anatomy and local tissue detail. Many learned CT reconstruction methods are tailored to a single dominant degradation. Existing diffusion and Gaussian approaches commonly recover global structure and local detail within a shared representation. We propose HiGDiff, a feed-forward hierarchical Gaussian diffusion framework that decomposes reconstruction both spatially and from structure to detail. Physics-conditioned anatomical anchors and a foreground capacity field allocate learnable Gaussian primitives to informative regions. A structure diffusion stage first recovers global attenuation geometry, and its learned representation conditions a detail diffusion stage for residual boundaries and tissue transitions. The resulting Gaussian banks are rendered as attenuation fields and further refined by a gradient-isolated residual module. Experiments on three distinct CT benchmark datasets demonstrate state-of-the-art reconstruction performance across isolated, paired, and joint degradation settings, including improvements of 5.81 dB in macro-average peak signal-to-noise ratio (PSNR) and 0.113 in structural similarity index measure (SSIM) on the Low Dose CT Image and Projection Data (LDCT-PD) collection. Code and experimental configurations are openly available at https://github.com/Bean-Young/HiGDiff.

0.24

Toward a Foundation Plug-and-Play Prior for Computed Tomography Reconstruction via a Multimodal Diffusion Model

cs.CV ·2026-08-24 ·Haley Duba-Sullivan, Patxi Fernandez-Zelaia, Obaidullah Rahman, Amirkoushyar Ziabari
published similarity 0.63
Abstract · To appear in SC26 Workshops proceedings

Computed tomography (CT) throughput is limited by scan time, which grows with both the number of projections acquired and the detector integration time for each projection. Reconstructing high-quality volumes from sparse-view or low-dose measurements therefore depends on using an informative prior, typically a neural network trained for one specific scan setting and retrained whenever the modality, geometry, or material changes. We investigate whether a single diffusion model trained across several imaging domains can instead serve as a reusable prior for heterogeneous CT reconstruction problems. We evaluate the proposed method using the same diffusion visual transformer model and normalized denoising strength on three datasets that differ in modality, beam geometry, material, and degradation type, spanning additively manufactured metal parts and concrete microstructure imaged with cone-bean X-ray CT and parallel-beam neutron CT respectively. The proposed method improves upon analytic reconstructions in all three cases, demonstrating transferability across the evaluated problems and providing a step toward a reusable foundation prior for heterogeneous CT reconstruction.

0.25

Consecutive Posterior Fusion for Diffusive Recovery of Unobservable Image Structures

cs.CV cs.AI ·2026-10-02 ·Elena Morotti, Davide Evangelista, Elena Loli Piccolomini
similarity 0.63
Abstract · 21 pages, 7 figures, 2 tables

Solving severely ill-posed imaging inverse problems requires recovering image structures that are unobservable or weakly constrained by the measurements. Diffusion models provide expressive learned priors for inferring such missing information, while posterior sampling incorporates measurement consistency along the reverse process. Standard diffusion posterior samplers, however, rely on instantaneous measurement-aware estimates, without explicitly exploiting information carried by previous posterior corrections. We introduce Consecutive Posterior Fusion Denoising Diffusion Null-Space Models (CPF-DDNM), an inference-time strategy that fuses consecutive measurement-aware estimates to improve the diffusive recovery of unobservable image structures, without requiring retraining or additional denoiser evaluations. We instantiate this principle within DDNM, whose range/null-space decomposition reveals that consecutive fusion preserves the measurement-determined component while acting exclusively on the prior-driven null-space estimate. We thus provide a geometric interpretation of CPF-DDNM and a local error analysis that characterizes the optimal time-dependent fusion coefficient, including the extrapolative regime. Experiments on sparse-view and simulated low-dose computed tomography, as well as medical image super-resolution, show consistent improvements over DDNM and competitive performance against diffusion-based inverse solvers.

0.14