CS Paper Radar

AgentCT: A Vision-Language Agent for Universal CT Imaging

Zhihao Chen, Qi Gao, Chuang Niu, Qiegen Liu, Yi Zhang, Hongming Shan

cs.CV ·submitted 2026-11-08 17:11 UTC · v1
code/datahot direction

Abstract

Computed tomography (CT) restoration methods often use a single network for low-dose CT (LDCT), sparse-view CT (SVCT), and metal artifact reduction (MAR), despite the distinct physics of these degradations. We propose AgentCT, a vision-language agent that identifies the degradation and routes images to task-specific restoration models. A LoRA-adapted Qwen3-VL-4B controller predicts degradation type and severity, selects a specialist, and reassesses the restored image. The LDCT specialist uses an image-domain diffusion model, whereas the SVCT and MAR specialists combine projection-domain correction, data consistency, differentiable filtered back-projection, and image refinement. We evaluated the controller and specialists separately on patient-disjoint Mayo 2020 abdominal CT data across three severity levels for each degradation. The controller achieved 95.7% accuracy for degradation type and 93.9% for severity, with a 100% JSON parse rate. Using ground-truth degradation labels for routing, AgentCT achieved an overall PSNR/SSIM of 46.18 dB/0.984, compared with 44.93 dB/0.976 for AMIR and 44.29 dB/0.979 for TAMP, and attained the highest PSNR in all nine settings. For SVCT, its dual-domain specialist achieved 46.04 dB with 4.2 million parameters, compared with 44.43 dB for single-task AMIR and 43.57 dB for all-in-one AMIR with 23.5 million parameters. These results support degradation-specific CT restoration with controller-based model selection; evaluation under automatic routing and on independent clinical data remains necessary. Code is available at https://github.com/hao1635/AgentCT.

Comment
14 pages, 5 figures

Closest papers

Nearest neighbours by meaning across the whole index.

MARR: Decoupling Policy, Execution, and Calibration for All-in-One Medical Image Restoration

cs.CV ·2026-09-06 ·Haobin Chen, Ao Chang, Heqin Zhu, Rundong Wang, Ting Liu +1 more
benchmarkcode/data similarity 0.70
Abstract · 8 pages, 4 figures, 2 tables

All-in-one medical image restoration seeks to recover heterogeneous clinical images with a single model, but PET, CT, and MRI differ substantially in degradation statistics, anatomical contrast, and output-space bias. A fully shared network can entangle modality-specific residual errors, whereas separate modality-specific networks sacrifice the practical advantages of unified deployment. We therefore recast all-in-one restoration as a question of where limited adaptation should be placed: policy selection, feature execution, or output calibration. We propose MARR, a compact restoration framework that constrains multi-modality adaptation into degradation-aware policy routing, modality-private residual execution, and image-domain residual correction without requiring degradation labels or separate modality-specific models. The policy branch forms a routing prompt from input statistics, latent content, and modality identity, and uses it only as a control signal. Prompt-gated modality-private adapters then perform lightweight residual refinement at intermediate decoder stages, while zero-initialized modality-specific output heads calibrate the final image-domain residual without perturbing the initial shared prediction. On an all-in-one PET, CT, and MRI restoration benchmark, MARR outperforms thirteen methods re-trained under the same protocol, achieving PSNR values of 37.34 dB, 33.85 dB, and 32.09 dB on PET, CT, and MRI, respectively, and the best modality-average PSNR of 34.43 dB. The code is publicly available at https://github.com/CHB-learner/MARR.

0.30

RouteDiff: Low-Dose CT Denoising via Fidelity-Refinement Routing and Hypergraph State Regulation

eess.IV cs.CV ·2026-11-12 ·Xinyuan Wang, Ruili Li, Tianyang Li, Yan Li, Xuepeng Liu
similarity 0.67
Abstract · 16 pages, 10 figures, 7 tables. Submitted to Knowledge-Based Systems

Diffusion models have become a strong prior for low-dose computed tomography (LDCT) restoration. However, existing samplers apply one structure-detail trade-off to the whole image, set the restoration emphasis of each step by the timestep, and derive each next state recursively from the current one, carrying its errors forward. We propose RouteDiff, a state-aware dual-route diffusion framework that routes detail to where it can be trusted, regulates each reverse step by the state it has reached, and re-enters the trajectory from an anchored estimate. Fidelity-Refinement Routing (FRR) equips one shared U-Net with a conservative fidelity route and a detail-oriented refinement route, fuses them pixel-wise with a confidence map, and exposes their disagreement as route evidence. Hypergraph State Regulation (HSR) organizes the current features and this evidence into a state hypergraph, whose soft hyperedges group scattered regions in the same state. Its readout yields an ordered stage judgment that modulates the bottleneck, and its incidence guides feature interaction in the skip connections. Estimate-Anchored Re-entry (EAR) re-projects a route-aware anchor onto the trajectory at a fixed step and hands the new state back to HSR to be judged again. With the ten network evaluations of its baseline, RouteDiff achieves the best peak signal-to-noise ratio (PSNR) and structural similarity index (SSIM) on four datasets with inserted, real and simulated noise (40.95 dB and 95.13% on Mayo 2020; 45.18 dB and 97.23% on Mayo 2016). It also generalizes to unseen doses of real scans and yields the highest Dice (80.92%) in downstream segmentation.

0.13

RIQE: a NIQE-style reference model for Computed Tomography

eess.IV cs.CV ·2026-09-30 ·Fabio Mattiussi
code/data similarity 0.66
Abstract · 17 pages, 6 figures, 6 tables. Code and model: https://github.com/Metallogik/RIQE, archived at doi:10.5281/zenodo.23055559

The Natural Image Quality Evaluator (NIQE) scores an image by its statistical distance from a model fitted on pristine images, and its distributed model is fitted on photographs. We release the Radiology Image Quality Evaluator (RIQE), a NIQE-style model fitted on 3,792 full-dose slices from 158 patients of the public LDCT-and-Projection-data collection, with a declared intensity mapping, a manifest of every slice and a script that reproduces the fit. On 40 held-out patients, RIQE ranks reduced-dose reconstructions, simulated by projection-domain noise insertion, worse than the full-dose reconstruction of the same slice in 240 of 240 chest and 230 of 240 abdominal pairs, and ranks images with 20% more noise worse than their source in 97.5-100% of cases. Its preferences among filtered images, however, do not follow lesion signal. With a 4 mm, +10 HU lesion inserted in noisy abdominal slices, RIQE prefers bilateral filtering to the unfiltered image in every image up to a 32 HU residual, at which 29% of the lesion's matched-filter signal remains and its detectability index falls from 0.51 to 0.33; it never prefers Gaussian smoothing, which at the same 32 HU residual leaves 70% of the signal and a detectability index of 0.48. Fitted on photographs with the parameters published for NIQE, the same code ranks every simulated reduced-dose abdominal image better than its full-dose counterpart. RIQE is suited to ranking a degraded image against its source; under the conditions tested it should not be the sole criterion for selecting, comparing or tuning denoisers.

0.57

FFAI: Flow Matching with Feedback Training and Adaptive Initialization for CT Reconstruction

cs.CV ·2026-10-29 ·Jigang Duan, Heran Wang, Genwei Ma, Xing Zhao
benchmark similarity 0.64
Abstract

Although low-dose, sparse-view, and limited-angle CT involve distinct degradation mechanisms, all three pose reconstruction challenges due to limited measurement information and can therefore be addressed within a unified framework. In iterative image restoration with flow matching, prediction errors may cause inference states to deviate from the prescribed training path, while a fixed initialization may be unsuitable for inputs with varying degradation severity. We propose a unified conditional flow matching method that conditions on the initial reconstruction and combines feedback-aware training with degradation-adaptive initialization. During training, a teacher network simulates inference updates to generate shifted states, from which a student network learns to recover high-quality reference images, improving its ability to handle prediction errors. During inference, the starting time is selected based on the noise level or extent of missing projection data, and the noise added to the initial state is adjusted accordingly to adapt the starting point to the input. Experiments on public benchmark datasets show that the proposed method achieves better quantitative results than the compared methods across all three reconstruction tasks, effectively suppressing noise and artifacts while preserving anatomical structures and details.

0.19

A deep dictionary network-based foundation model for ultra-low-dose CT denoising

eess.IV cs.CVcs.LG ·2026-09-11 ·Baoshun Shi, Shuangyi Yang, Ke Jiang, Bin Zhu, Zhanli Hu +1 more
similarity 0.63
Abstract

Ultra-low-dose computed tomography (ULDCT) reduces radiation exposure but suffers from severe noise that degrades diagnostic image quality. Existing deep learning-based denoising methods are typically trained in an organ-specific fashion, resulting in limited generalization across heterogeneous multi?organ imaging scenarios. Foundation models present a promising all-in-one paradigm for unified multi-organ denoising. However, their architectures suffer from poor interpretability and rely on heuristic training strategies. To address these limitations, we propose an architecture?interpretable foundation model based on the deep dictionary network (DDN) for unified multi-organ ULDCT denoising. Inspired by multilayer sparse representation theory, DDN cascades convolutional sparse coding layers with iterative soft-thresholding, providing inherent architectural interpretability. Furthermore, a dynamic dictionary module and a threshold generation module are embedded within each layer to enhance representation ability. We conduct DDN pre-training on more than one million multi-organ normal-dose CT images by recovering clean images from Gaussian-noised inputs. Sparse regularization is additionally imposed on latent feature representations, guiding the network to learn compact and noise-robust priors. The complete architecture is jointly fine-tuned on multi-organ ULDCT datasets, enabling a single unified model to perform denoising across diverse anatomical regions. Extensive experiments validate that our proposed method achieves state-of-the?art performance and consistently surpasses competing ULDCT methods across all mul

0.28

Measurement-Aware Multimodal LLM for No-Reference Low-Dose CT Quality Assessment

eess.IV cs.CV ·2026-11-05 ·Kerem Basim, Tolga Demiroglu, Mehmet Ozan Unal, Metin Ertas, Isa Yildirim
hot direction similarity 0.63
Abstract · 5 pages, 2 figures, 3 tables. Submitted to IEEE ISBI 2027

No-reference image quality assessment (IQA) of low-dose CT predicts the score that radiologists would assign to a slice without a full-dose reference, as needed to compare dose protocols and denoisers. Trained CT IQA networks agree well with radiologists but output only a score, whereas multimodal large language models (MLLMs) can explain a score but perform poorly on CT when only prompted. We propose a measurement-aware MLLM, built on Qwen3.8-27B, that rates a slice from its image together with six image-domain measurements of noise, sharpness, high-frequency content and streaks, given to the language model as percentiles in text. On the LDCT-IQA 2023 test set, it reaches an Overall score of 2.735, on par with the retrained challenge winner (2.735) and MedSigLIP-FiLM (2.713), and substantially above its base MLLM used as a zero-shot agent. Shuffling the measurements at test time reduces the score by 0.048, mostly through noise, but the same measurements also lead the model to assign higher scores to over-smoothed denoised images.

0.34

Toward a Foundation Plug-and-Play Prior for Computed Tomography Reconstruction via a Multimodal Diffusion Model

cs.CV ·2026-08-24 ·Haley Duba-Sullivan, Patxi Fernandez-Zelaia, Obaidullah Rahman, Amirkoushyar Ziabari
published similarity 0.63
Abstract · To appear in SC26 Workshops proceedings

Computed tomography (CT) throughput is limited by scan time, which grows with both the number of projections acquired and the detector integration time for each projection. Reconstructing high-quality volumes from sparse-view or low-dose measurements therefore depends on using an informative prior, typically a neural network trained for one specific scan setting and retrained whenever the modality, geometry, or material changes. We investigate whether a single diffusion model trained across several imaging domains can instead serve as a reusable prior for heterogeneous CT reconstruction problems. We evaluate the proposed method using the same diffusion visual transformer model and normalized denoising strength on three datasets that differ in modality, beam geometry, material, and degradation type, spanning additively manufactured metal parts and concrete microstructure imaged with cone-bean X-ray CT and parallel-beam neutron CT respectively. The proposed method improves upon analytic reconstructions in all three cases, demonstrating transferability across the evaluated problems and providing a step toward a reusable foundation prior for heterogeneous CT reconstruction.

0.25

EORestore-Agent: Fidelity-Guided Agentic Restoration of Remote Sensing Images with Composite Degradations

cs.CV ·2026-10-05 ·Heli Qi, Zeqi Zhou, Jingjun Yi, Kunyi Liu, Ziyang Lihe +3 more
benchmark similarity 0.63
Abstract · 20 pages, 6 figures, 11 tables, including appendices

Remote sensing images often carry composite degradations, in which haze, cloud, noise, blur, low light, and low resolution coexist. Restoring them requires deciding which tool to apply, in what order, and when to stop, yet no clean reference is available at inference time to verify these decisions. All-in-one models trained on single degradations converge to a narrow PSNR band as degradations accumulate. To formulate real-world remote sensing restoration as a traceable trajectory, we present EORestore-Agent, which replaces this unmeasurable objective with reference-free, verifiable per-step decisions. A fine-tuned vision-language model reports all residual degradation types, whose tool pools are scored together, so the restoration order emerges from step-wise selection. A relative quality scorer, trained with full-reference supervision on synthetic degradation chains, predicts the changes in PSNR, SSIM, and LPIPS from the current image to each candidate. A step is accepted only when no predicted change is negative and the predicted PSNR gain is positive. Otherwise, the agent keeps the current image. On a synthetic Landsat-8 benchmark with six degradation types, EORestore-Agent improves PSNR by 2.3 to 3.2 dB over the strongest retrained all-in-one baseline on composites of two to six degradations, whereas zero-shot natural-image agents fall below the degraded input in PSNR in 17 of 18 settings. Replacing the learned scorer with no-reference quality differences costs 1.1 to 4.6 dB. The remaining harmful steps are small and cluster near the acceptance threshold. Sentinel-2 examples illustrate transfer to real atmospheric degradation without retraining.

0.21