CS Paper Radar

Measurement-Aware Multimodal LLM for No-Reference Low-Dose CT Quality Assessment

Kerem Basim, Tolga Demiroglu, Mehmet Ozan Unal, Metin Ertas, Isa Yildirim

eess.IV cs.CV ·submitted 2026-11-05 22:02 UTC · v1
hot direction

Abstract

No-reference image quality assessment (IQA) of low-dose CT predicts the score that radiologists would assign to a slice without a full-dose reference, as needed to compare dose protocols and denoisers. Trained CT IQA networks agree well with radiologists but output only a score, whereas multimodal large language models (MLLMs) can explain a score but perform poorly on CT when only prompted. We propose a measurement-aware MLLM, built on Qwen3.8-27B, that rates a slice from its image together with six image-domain measurements of noise, sharpness, high-frequency content and streaks, given to the language model as percentiles in text. On the LDCT-IQA 2023 test set, it reaches an Overall score of 2.735, on par with the retrained challenge winner (2.735) and MedSigLIP-FiLM (2.713), and substantially above its base MLLM used as a zero-shot agent. Shuffling the measurements at test time reduces the score by 0.048, mostly through noise, but the same measurements also lead the model to assign higher scores to over-smoothed denoised images.

Comment
5 pages, 2 figures, 3 tables. Submitted to IEEE ISBI 2027

Closest papers

Nearest neighbours by meaning across the whole index.

QICOM: Open-Source Software for Reproducible Image Quality Evaluation, Blinded Assessment, and Radiomic Comparison

eess.IV cs.AI ·2026-10-22 ·Fabio Mattiussi, Switinder Ghotra
code/data similarity 0.66
Abstract

QICOM (Quality Image COMparator) is open-source software for quantitative image comparison, paired radiomics, and blinded assessment. It saves processing settings, image identities, measurements, and response mappings so a comparison can be reopened and recalculated. We evaluate reference agreement, responses to controlled perturbations, and recovery of saved analyses. Synthetic experiments cover 37 quantitative descriptors using independentnumerical references and separate upstream integration comparisons. The QICOM/MIRP backend meets the reference tolerances for all 482 numeric IBSI 1 digital-phantom entries and all 1,622 entries across configurations A-E of the public CT reference case; these comprise 1,804 feature/aggregation comparisons and 300 preprocessing diagnostics. Restricting masked SSIM and HFEN to complete kernel support removes the observed dependence on excluded pixels. In a synthetic filtering example, stronger smoothing increases SSIM while worsening MSE and HFEN relative to milder smoothing and changing GLCM contrast more strongly. Reopened radiomics projects reproduce all 43 feature pairs per comparison, and two blinded deliveries return four correctly mapped scripted responses. These experiments document the calculations and data transfers linking the three workflows.

0.30

AgentCT: A Vision-Language Agent for Universal CT Imaging

cs.CV ·2026-11-08 ·Zhihao Chen, Qi Gao, Chuang Niu, Qiegen Liu, Yi Zhang +1 more
code/datahot direction similarity 0.63
Abstract · 14 pages, 5 figures

Computed tomography (CT) restoration methods often use a single network for low-dose CT (LDCT), sparse-view CT (SVCT), and metal artifact reduction (MAR), despite the distinct physics of these degradations. We propose AgentCT, a vision-language agent that identifies the degradation and routes images to task-specific restoration models. A LoRA-adapted Qwen3-VL-4B controller predicts degradation type and severity, selects a specialist, and reassesses the restored image. The LDCT specialist uses an image-domain diffusion model, whereas the SVCT and MAR specialists combine projection-domain correction, data consistency, differentiable filtered back-projection, and image refinement. We evaluated the controller and specialists separately on patient-disjoint Mayo 2020 abdominal CT data across three severity levels for each degradation. The controller achieved 95.7% accuracy for degradation type and 93.9% for severity, with a 100% JSON parse rate. Using ground-truth degradation labels for routing, AgentCT achieved an overall PSNR/SSIM of 46.18 dB/0.984, compared with 44.93 dB/0.976 for AMIR and 44.29 dB/0.979 for TAMP, and attained the highest PSNR in all nine settings. For SVCT, its dual-domain specialist achieved 46.04 dB with 4.2 million parameters, compared with 44.43 dB for single-task AMIR and 43.57 dB for all-in-one AMIR with 23.5 million parameters. These results support degradation-specific CT restoration with controller-based model selection; evaluation under automatic routing and on independent clinical data remains necessary. Code is available at https://github.com/hao1635/AgentCT.

0.42

RIQE: a NIQE-style reference model for Computed Tomography

eess.IV cs.CV ·2026-09-30 ·Fabio Mattiussi
code/data similarity 0.62
Abstract · 17 pages, 6 figures, 6 tables. Code and model: https://github.com/Metallogik/RIQE, archived at doi:10.5281/zenodo.23055559

The Natural Image Quality Evaluator (NIQE) scores an image by its statistical distance from a model fitted on pristine images, and its distributed model is fitted on photographs. We release the Radiology Image Quality Evaluator (RIQE), a NIQE-style model fitted on 3,792 full-dose slices from 158 patients of the public LDCT-and-Projection-data collection, with a declared intensity mapping, a manifest of every slice and a script that reproduces the fit. On 40 held-out patients, RIQE ranks reduced-dose reconstructions, simulated by projection-domain noise insertion, worse than the full-dose reconstruction of the same slice in 240 of 240 chest and 230 of 240 abdominal pairs, and ranks images with 20% more noise worse than their source in 97.5-100% of cases. Its preferences among filtered images, however, do not follow lesion signal. With a 4 mm, +10 HU lesion inserted in noisy abdominal slices, RIQE prefers bilateral filtering to the unfiltered image in every image up to a 32 HU residual, at which 29% of the lesion's matched-filter signal remains and its detectability index falls from 0.51 to 0.33; it never prefers Gaussian smoothing, which at the same 32 HU residual leaves 70% of the signal and a detectability index of 0.48. Fitted on photographs with the parameters published for NIQE, the same code ranks every simulated reduced-dose abdominal image better than its full-dose counterpart. RIQE is suited to ranking a degraded image against its source; under the conditions tested it should not be the sole criterion for selecting, comparing or tuning denoisers.

0.58

VGIQA: Fine-Grained Image Quality Assessment with Visual Grounding Rewards

cs.CV ·2026-10-27 ·Weichang Wang, Liyu Chen, Shuyue Guan, Jie Hu, Fei Gao +2 more
datasetcode/data similarity 0.60
Abstract · 20 pages, 5 figures, 6 tables; main paper: 4 figures and 4 tables, appendix: 1 figure and 2 tables

Image quality assessment (IQA) aims to evaluate the perceptual visual quality of images. Recently, the rapid development of Multi-modal Large Language Models (MLLMs) has significantly advanced the IQA field. By integrating chain-of-thought (CoT) reasoning and reinforcement learning (RL), these models can generate more accurate and interpretable results while relying on less training data. However, existing MLLM-based methods are predominantly constrained to holistic, image-level evaluations and lack the capability to produce fine-grained, localized assessments, which substantially limits their practical applicability. To address this limitation, we propose VGIQA, a novel IQA model endowed with both local and global quality assessment capabilities. VGIQA is trained via a two-stage paradigm comprising a cold-start phase followed by reinforcement learning. Driven by carefully designed local quality assessment reward functions, our model exhibits exceptional image quality understanding on VGSR-2K, a new dataset we propose specifically for local quality evaluation, significantly outperforming existing open-source MLLMs such as Qwen2.5-VL-72B-Instruct and Qwen3-VL-32B-Instruct. Furthermore, the local quality evaluation task can effectively enhance the model's performance on the degradation perception task.

0.20

One Step Is Optimal: Unconditional Rectified Flows as Noise2Noise Denoisers for Low-Dose CT

cs.CV ·2026-09-15 ·Timothy Sereda, Debesh Jha
benchmark similarity 0.60
Abstract · 15 pages, 3 figures

We study rectified flows for denoising without clean training targets. For an unconditional rectified flow trained on Noise2Noise pairs, the optimal velocity field yields the minimum mean squared error (MMSE) denoiser in one step. In a jointly Gaussian model, we show that integrating the flow before applying its denoising readout increases error with integration time. The flow transports between noisy distributions, so its endpoint is not a clean-image estimate. Experiments on low-dose CT and Gaussian-corrupted natural images follow this pattern: one-step flow performs similarly to direct regression on the same pairs, whereas additional Euler steps reduce PSNR. A direct regressor using spatially separated, similar patches gives our best label-free CT result, a $1.99$\,dB gain over the noisy input. We report these results in CTDenoiser, a benchmark covering five architectures, supervised and self-supervised training, and two per-image methods. Supervised CNNs gain about $4$\,dB, while label-free performance depends strongly on how training pairs account for correlated CT noise. A channelized Hotelling observer also shows that fidelity gains need not improve lesion detectability: detectability falls at $160$\,HU despite higher PSNR and SSIM, while changes at $40$--$80$\,HU are small. Code, model definitions, and data-loading utilities will be released publicly; the repository link is withheld for anonymous review.

0.31

Reference-Guided Data Curation for 3D Medical Vision-Language Pretraining

cs.CV ·2026-11-17 ·Faidra Patsatzi, Ashwin Kumar, Chong Wang, Curtis P. Langlotz, Reinhard Heckel +1 more
publishedcode/data similarity 0.60
Abstract · Accepted at WACV 2027. Code: https://github.com/StanfordMIMI/data-curation-3d-medical-vlm

Training 3D vision-language models (VLMs) on large medical imaging datasets collected across institutions is constrained by data quality. Vast, uncurated pools of image-report pairs are characterized by redundancy, class imbalance, and cross-institutional heterogeneity. We address this challenge of data curation for improving 3D VLM pretraining by proposing an offline, training-free, reference-guided data curation recipe. Our approach leverages a small, high-quality reference set to independently extract quality signals for each modality of a large, uncurated pool and merges them through a rank-aggregation step into a single ranking that guides sample selection. We validate this method on datasets comprising 35k 3D abdominal CT volume-report pairs from two institutions and 58k 2D chest X-ray image-report pairs. On 3D CT, using our reference-guided data curation strategy, our curated model matches the zero-shot disease classification performance of a state-of-the-art baseline (Merlin) while using $3.3\times$ less training data and a reference set of 5k samples. On 2D chest X-rays, our method yields a curated model that matches or exceeds the zero-shot disease classification performance of a model trained on the full pool while using up to $10\times$ less training data and a reference set of only 74 samples. Ablations show that the selection is stable under resampling of the reference, that smaller reference sets still outperform random sampling, and that label rebalancing does not improve performance. To support reproducibility, we release our code.

0.52

BiCG-Net: Target-Specific Image Quality Assessment via Observation Modeling and In-Image Differencing

cs.CV ·2026-11-04 ·Yibu Yang, Tingqiong Cui, Liming Lei, Hao Xiong, Jun Xu +2 more
benchmark similarity 0.60
Abstract · 34 pages, 3 figures

We estimate the quality of a specific target region (e.g., a train body) in an image, rather than the whole image. This differs fundamentally from whole-image No-Reference Image Quality Assessment (NR-IQA): when the target occupies a small fraction of the frame, the whole-image score is dominated by background, and no public benchmark provides target-level human Mean Opinion Score (MOS). We estimate target quality via nested sampling - a sequence of patches expanding outward from the target box - and infer quality from the relative structure of this sequence. This motivates BiCG-Net, a student network that distills an 11-teacher ensemble through a linear observation model and an in-image differencing mechanism, which provably cancels the target term and teacher-specific bias. We train and test the student independently on each dataset, and evaluate zero-shot transfer across benchmarks. On CSIQ and LIVEC, the student reaches PLCCs of 0.9009 and 0.9133 against human MOS, exceeding the best single teacher and the teacher consensus. On a self-built MOS-free railway dataset, the student reaches a PLCC of 0.9855 against a weak label. The student exceeds its teachers because it learns a new mapping from the relative structure of teacher readings to the ground-truth label, rather than mimicking them. Residual analysis on CSIQ and LIVEC shows the prediction residual is significantly correlated with background contamination, teacher dispersion, and label extremity, demonstrating the student extracts information the consensus does not contain. Under CSIQ-to-LIVEC transfer, the frozen student reaches a PLCC of 0.8416, exceeding the consensus by 0.1947. We position BiCG-Net as an offline target-level quality auditing and label-generation engine; its 39,482-parameter student is compact by design, acting as a unifying layer mapping heterogeneous teacher readings onto a common quality scale.

0.30

Solving the Needle-in-a-Haystack Problem in Mammography Vision-Language Model with Differentiable Subset Sampling

cs.CV ·2026-09-02 ·Young Seok Jeon, Beatrice Brown-Mulry, Rohan Satya Isaac, Anjana Dissanayaka, Theo Dapamede +3 more
positioncode/data similarity 0.60
Abstract

There is growing interest in adopting CLIP-style vision--language model (VLM) pretraining for mammography. However, models that directly employ the standard CLIP architecture and training objective exhibit limited zero-shot performance in clinically important tasks such as cancer, finding-type, and BI-RADS predictions. We argue that this underwhelming performance is due to neglecting two characteristics of mammography data: (1) its high-res nature, and (2) homogeneity of radiology reports, largely driven by a predominance of negative/benign findings on examinations. We propose TopKSigLIP, a VLM designed to address these two limitations through a novel architecture and learning objectives. Instead of downscaling high-res mammography images to satisfy GPU memory constraints, TopKSigLIP introduces TopK-Patch module that learns to sample a sparse set of high-res patches likely to contain lesions, sidestepping the resolution--batch size tradeoff of VLM training. The sampled patch locations additionally serve as a built-in localization tool. To address report homogeneity, we replace the contrastive loss, which falsely repels semantically similar pairs, with a Sup-sigmoid loss. Sup-sigmoid loss extends the sigmoid loss from SigLIP with soft labels derived from structured data. TopKSigLIP outperforms existing open-source mammography and general medical VLMs on both internal and external benchmarks on density assessment, BI-RADS classification, finding subtyping, and cancer prediction under zero-shot evaluation. TopKSigLIP remains competitive under linear probing despite using a significantly smaller vision encoder and smaller training batches than baselines. The TopK-Patch module additionally achieves superior lesion localization over post-hoc Grad-CAM. Code and weights are made public:https://github.com/Youngseok0001/TopKSigLIP.

0.30