Feed-Forward Hierarchical Gaussian Diffusion for Extreme CT Reconstruction

Yuezhe Yang, Li Cheng

cs.CV ·submitted 2026-08-15 17:56 UTC · v1
benchmarkcode/data

Abstract

Reconstructing three-dimensional computed tomography (CT) from severely constrained projections is highly ill-posed. Sparse angular sampling, restricted angular coverage, and low photon counts can occur individually or jointly, obscuring global anatomy and local tissue detail. Many learned CT reconstruction methods are tailored to a single dominant degradation. Existing diffusion and Gaussian approaches commonly recover global structure and local detail within a shared representation. We propose HiGDiff, a feed-forward hierarchical Gaussian diffusion framework that decomposes reconstruction both spatially and from structure to detail. Physics-conditioned anatomical anchors and a foreground capacity field allocate learnable Gaussian primitives to informative regions. A structure diffusion stage first recovers global attenuation geometry, and its learned representation conditions a detail diffusion stage for residual boundaries and tissue transitions. The resulting Gaussian banks are rendered as attenuation fields and further refined by a gradient-isolated residual module. Experiments on three distinct CT benchmark datasets demonstrate state-of-the-art reconstruction performance across isolated, paired, and joint degradation settings, including improvements of 5.81 dB in macro-average peak signal-to-noise ratio (PSNR) and 0.113 in structural similarity index measure (SSIM) on the Low Dose CT Image and Projection Data (LDCT-PD) collection. Code and experimental configurations are openly available at https://github.com/Bean-Young/HiGDiff.

Closest papers

Nearest neighbours by meaning across the whole index.

AD-GS: Anatomical Density-guided 3D Gaussian Splatting for Sparse-View Dental CBCT Reconstruction

cs.CV ·2026-10-10 ·Zonglin Li, Kexian Xie, Feiran Li, Chu Zhou, Yixing Huang +3 more
code/data similarity 0.74
Abstract

Sparse-view Cone-Beam Computed Tomography (CBCT) reconstruction is essential for reducing radiation dose and scan effort, but remains underconstrained due to limited projection information. Recent 3D Gaussian Splatting (3DGS)-based CBCT reconstruction methods rely on gradient-driven densification, which becomes unstable under sparse acquisition and often leads to over-smoothed structures. We propose AD-GS, an Anatomical Density-guided 3D Gaussian Splatting framework that formulates Gaussian densification as an attenuation-aware Markov Chain Monte Carlo (MCMC) sampling process. By interpreting Gaussians as samples from an underlying anatomical attenuation distribution, AD-GS adaptively concentrates representation capacity in high-attenuation regions, enabling sharper structural boundaries under sparse projections. To further constrain reconstruction, we incorporate a semantic regularization based on zero-shot features from Segment Anything in Medical Images, enforcing multi-view consistency through semantic priors. Experiments on the ToothFairy3 dental CBCT dataset demonstrate that AD-GS achieves superior structural fidelity and boundary preservation compared with existing 3DGS-based approaches under sparse-view settings within the dental and maxillofacial setting. Code is available at https://github.com/yulinjiaxue/AD-GS-BMVC2026.

0.29

Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising

eess.IV ·2026-09-30 ·Ping Wu, Pengcheng Zheng, Jiahao Zhang, Bohao Chen, Yazhou Ren +1 more
similarity 0.73
Abstract · 10 pages

Low-dose CT (LDCT) reduces radiation exposure but often introduces severe noise and streak artifacts that obscure subtle anatomical structures. Existing diffusion-based denoising methods commonly rely on implicit assumptions about the noise distribution, which may not hold in practical LDCT scenarios and can degrade denoising performance. To address this limitation, we propose a Residual-Guided Diffusion framework that effectively incorporates an explicit difference prior to inform the diffusion process of noise distribution. The difference prior is computed as the residual between the LDCT image and a coarse clean estimate, constraining diffusion sampling to a plausible residual space. We further adopt a coarse-to-fine strategy in which a pre-trained RED-CNN provides the coarse estimate to anchor global anatomy, and the diffusion model refines the remaining details under the prior guidance. For efficiency, we employ accelerated sampling with 20 steps at inference. Experiments on three representative datasets demonstrate that our approach outperforms existing methods in both quantitative and qualitative performance measures.

0.14

Toward a Foundation Plug-and-Play Prior for Computed Tomography Reconstruction via a Multimodal Diffusion Model

cs.CV ·2026-08-24 ·Haley Duba-Sullivan, Patxi Fernandez-Zelaia, Obaidullah Rahman, Amirkoushyar Ziabari
published similarity 0.71
Abstract · To appear in SC26 Workshops proceedings

Computed tomography (CT) throughput is limited by scan time, which grows with both the number of projections acquired and the detector integration time for each projection. Reconstructing high-quality volumes from sparse-view or low-dose measurements therefore depends on using an informative prior, typically a neural network trained for one specific scan setting and retrained whenever the modality, geometry, or material changes. We investigate whether a single diffusion model trained across several imaging domains can instead serve as a reusable prior for heterogeneous CT reconstruction problems. We evaluate the proposed method using the same diffusion visual transformer model and normalized denoising strength on three datasets that differ in modality, beam geometry, material, and degradation type, spanning additively manufactured metal parts and concrete microstructure imaged with cone-bean X-ray CT and parallel-beam neutron CT respectively. The proposed method improves upon analytic reconstructions in all three cases, demonstrating transferability across the evaluated problems and providing a step toward a reusable foundation prior for heterogeneous CT reconstruction.

0.25

PhyDiCT: Plug-and-Play CT Reconstruction from Sparse X-Rays via Differentiable Rendering and Strong Priors

cs.CV ·2026-10-07 ·Weicheng Dai, Shantanu Ghosh, Kayhan Batmanghelich
top venuecode/data similarity 0.71
Abstract · Accepted at MICCAI 2026; to appear in LNCS 16888

Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric information. We propose PhyDiCT, a training-free framework that integrates a differentiable Physics-based forward model, grounded in the Beer-Lambert law, with a text-conditioned Diffusion as a strong prior to reconstruct 3D lung CT images. We refer to our approach as training-free since the prior model is used without fine-tuning, and our goal is to steer the denoising procedure to generate samples consistent with X-ray observations. We guide the diffusion generation using Split Gibbs sampling to jointly optimize for projection fidelity (reward) and consistency with prior knowledge. Also, we introduce a test-time refinement step that enhances image realism and anatomical coherence. We extensively evaluate our method on publicly available 3D CT datasets using both perceptual and semantic metrics, demonstrating that it surpasses existing plug-and-play diffusion and fully trained reconstruction approaches. Our findings highlight that combining a strong generative prior with the underlying physics of image formation substantially improves reconstruction quality, e.g., 7.5\% improvement on SSIM compared to full training methods. Code will be released at https://github.com/batmanlab/PhyDiCT.

0.44

Extremely Sparse-View Computed Tomography from 2D Projections via Pose-Aware Diffusion Priors

cs.CV cs.AI ·2026-10-28 ·Linrui Dai, Jinxiu Liang, Chu Zhou, Mae Yamaguchi, Ryuya Takahashi +1 more
published similarity 0.71
Abstract · NeurIPS 2026 poster

Extremely sparse-view computed tomography (xSV-CT) is critical when scanning time, motion, or radiation tolerance limits each scan to only a few projections. In many such scenarios, the same acquisition limits also constrain dataset construction, making pre-reconstructed 3D volumes from dense scans unavailable. This exposes a gap in current sparse-view approaches: Optimization-based methods, which use the sparse measurements directly but lack data-driven priors to suppress artifacts, and learning-based methods, which use strong priors but usually require densely scanned training volumes acquired outside the xSV-CT regime. We study this train-sparse / infer-sparse setting by learning a pose-aware diffusion prior from one 2D projection per training sample, then guiding diffusion sampling with measured-view fidelity, shared-volume reprojection, and projection-physics consistency for tomographic reconstruction. On two public CT datasets across 1-, 4-, and 8-view settings, the proposed method achieves the best novel-view synthesis scores and best or competitive reconstruction quality compared with baselines that use dense-volume supervision.

0.26

Advanced Brain Tissue Imaging with Data-Consistent Diffusion Priors in Laminographic X-Ray Nanoimaging

cs.CV ·2026-09-09 ·Wenxuan Fang, Abraham L. Levitan, Ana Diaz, Carles Bosch, Adrian Wanner +8 more
similarity 0.71
Abstract

Nanoscale imaging of mammalian brains is critical for connectomics. X-ray laminography enables high-throughput imaging of extended, plate-like biological specimens. However, the tilted acquisition geometry leads to incomplete Fourier-space coverage, giving rise to a missing-cone of information. Conventional reconstruction methods cannot recover unmeasured information within the cone, resulting in artifacts that distort fine brain structures. While resolving these requires modeling 3D structure, direct 3D deep learning approaches are limited by data scarcity and computational cost. Here we introduce LUCID (Laminography with Unified Consistent Diffusion), a framework that combines multi-view diffusion priors with projection-domain data consistency. LUCID integrates complementary 3D structural information while enforcing strict alignment with the laminography forward model. On simulated datasets, LUCID substantially improves spatial fidelity and restores missing Fourier components, outperforming baseline methods. Applied to experimental laminography data, LUCID generalizes robustly despite being trained exclusively on fully sampled tomographic volumes, and effectively recovers unmeasured Fourier information.

0.20

Physics-Guided Flow Matching for CT Image Reconstruction

cs.AI cs.CV ·2026-08-28 ·Davide Evangelista
similarity 0.70
Abstract · 16 pages, 6 figures, 2 tables

Deep generative models have recently emerged as powerful priors for solving ill-posed inverse problems in CT, with diffusion-based approaches achieving state-of-the-art reconstruction performance. However, diffusion models typically rely on stochastic sampling procedures, long inference trajectories, and carefully tuned noise schedules, which can limit computational efficiency and numerical stability, especially at high spatial resolutions. In this work, we investigate Flow Matching as an alternative generative prior for CT reconstruction. We train a high-resolution Rectified Flow Matching model on 256x256 chest images from the Mayo Clinic Low-Dose CT dataset. To mitigate overfitting and limited anatomical variability, we employ a two-stage training strategy consisting of an initial phase with strong, anatomically informed data augmentation, followed by a fine-tuning phase with reduced or no augmentation to refine structural fidelity. The resulting model is capable of generating high-quality and anatomically coherent CT-like images, serving as a strong learned prior. We then evaluate multiple reconstruction methods specifically designed for Flow Matching models, including Plug-and-Play Flow, FlowDPS, Flower, and Flow-Priors (ICTM), and compare them against state-of-the-art diffusion-based reconstruction algorithms such as DDRM, DPS, and DiffPIR. Experimental results across several CT inverse problem settings show that Flow Matching-based approaches consistently outperform diffusion-based methods in terms of PSNR, SSIM, and perceptual quality, while requiring fewer sampling steps. Finally, we publicly release the trained Flow Matching model and accompanying code to facilitate reproducibility and future research. Overall, this work demonstrates that Flow Matching provides a stable, efficient, and effective alternative to diffusion models for high-resolution CT image reconstruction.

0.41

Taming Neural Fields with a Frequency-Lipschitz Curriculum for Sparse-View CT Reconstruction

cs.CV cs.LG ·2026-11-11 ·Songtao Hu, Jingrui Wu, Hong Ding, Fanhao Zhu, Yunhao Liu +1 more
similarity 0.70
Abstract

Sparse-view computed tomography (SVCT) reduces radiation dose by acquiring fewer projection views, but the resulting under-determined inverse problem requires careful regularization to prevent reconstruction algorithms from fitting streak artifacts and hallucinated structures. Existing implicit neural representation (INR) methods rely on implicit spectral bias or iterative external denoising, yet they provide limited control over when high-frequency capacity is exposed during optimization. To address this limitation, we propose FLIC (Frequency-Lipschitz INR Curriculum), a capacity-controlled self-prior INR framework that makes the network's representational capacity explicit and schedulable. The core of our method is a joint frequency-Lipschitz curriculum that couples random Fourier feature encoding with spectrally normalized MLP decoding under non-uniform Lipschitz budgets, guiding reconstruction along a coarse-to-fine trajectory from stable global anatomy to fine details. The terminal capacity is automatically calibrated from FBP gradient statistics, enabling scan-adaptive regularization without per-scan manual tuning of the terminal Lipschitz budget. We further introduce a prior-guided adaptive ray sampling strategy that concentrates integration samples near high-gradient anatomical boundaries, improving forward-model fidelity. The entire framework operates in a single training stage without iterative denoising, enabling efficient per-image reconstruction. Extensive experiments on four public CT datasets under noise-free and low-dose settings show that our method achieves state-of-the-art unsupervised reconstruction quality with consistent performance across diverse anatomical structures.

0.13