Zero-shot evaluation of open vision-language models as System 1 decision models on radiology tasks

Bradley J Erickson, Sara Salehi

cs.CV cs.AI ·submitted 2026-11-01 06:32 UTC · v1

Abstract

Purpose: We compared two multimodal System 1 decision models, Clef 27B and d1 3B, with a traditional LLM (Qwen 3.8-27B) on seven radiology tasks covering text, radiographs, CT and MRI. Methods: Three models were compared: Clef, Qwen3.8-27B and d1. Three tasks were interpretation of text and 4 were detection of finding in images. The tasks were: 1. finding presence of finding in CT-RATE chest CT reports; 2. Presence of finding in PadChest chest radiograph reports; 3. the same 18 findings on CT-RATE chest CT but 3D volumes; 4. MR safety status of devices from AccessGUDID device records; 5. line and tube position on RANZCR CLiP chest radiographs; 6. motion-artifact severity on MR-ART T1-weighted brain MRI and 7. sequence identification on BraTS 2021 brain MRI. The primary endpoint was AUROC. There was no fine-tuning of the models on the tasks. Results: All models completed all tests without a failed request. All retrieved findings from reports almost perfectly (AUROC >0.95). Clef ranked higher than its Qwen backbone on CT-RATE volumes and RANZCR lower on MR-ART. The two did not differ on BraTS, GUDID or PadChest, and differed by 0.002 on CT-RATE reports. On BraTS, Clef correctly identified 90 of 100 FLAIR volumes while Qwen never chose it. d1 ranked lower than Clef on six of seven tasks. No model performed well on motion severity. Clef was faster per request than Qwen on tasks with many questions per input. d1 used 3 to 9 times less energy per request than Clef. Conclusions: System 1 models can perform important tasks in radiology with high accuracy, at lower compute cost than LLMs used in the usual way. When an LLM is constrained to a single answer token, its cost and performance is similar to System 1 models unless multiple questions are asked. A 3B System 1 model was close to the 27B models on report text but not on images. No model performed well on motion severity.

Comment
22 pages, 3 tables, 2 figures

Closest papers

Nearest neighbours by meaning across the whole index.

ProtoBridge-CLIP: Observation-Masked Finding Prototypes for Medical Image--Report Representation Learning

cs.CV cs.AI ·2026-11-18 ·Jinrui Wu, Yun Peng
similarity 0.66
Abstract

Radiology reports distinguish affirmed findings, explicit negations, and unmentioned concepts, but conventional global image--report contrastive learning often compresses these different evidence states into a single study-level target. We introduce \model{}, which combines symmetric global image--report alignment with observation-masked finding supervision and a soft relation objective over affirmed report concepts. Text-derived finding prototypes are aligned with local visual tokens, while uncertain and unmentioned concepts are excluded from direct finding labels. We evaluate the framework on three CT benchmarks and five chest-radiograph benchmarks, together with component ablations, paired and clinical retrieval, localization, perturbation robustness, calibration, and per-finding analyses. \model{} achieves macro-AUROC values of 73.6%, 66.5\%, and 68.8% on CT-RATE, RAD-ChestCT, and INSPECT, and 80.2%, 91.4%, 78.5%, 86.5%, and 90.8% on ChestXray14, CheXpert, PadChest, RSNA, and SIIM-ACR, respectively. Relative to the matched global-only controls, the findings and relation objectives yield consistent gains across the evaluated datasets. These results demonstrate the practical value of treating observed and unobserved report concepts differently during medical image--text representation learning.

0.13

Beyond Benchmark Scores: Auditing Medical Vision-Language Models for Chest X-Ray Tuberculosis Screening

cs.CV cs.LG ·2026-09-18 ·Mushir Akhtar, M. Tanveer, Mohd. Arshad
benchmark similarity 0.66
Abstract · 27 pages, 7 figures, and 21 tables; includes extended methods, statistical analyses, and robustness evaluations

A medical model's benchmark score does not establish that the same conclusion holds under a different evaluation. This study tests whether claims about model ranking, score reliability and screening performance survive changes in cohort, prompt, negative spectrum, specified prevalence and operating threshold. We audit three medical vision-language models (BioMedCLIP, CheXficient, and MedSigLIP) and a general-domain OpenCLIP comparator on 12,200 chest radiograph records from four datasets (Montgomery, Shenzhen, TBX11K, and VinDr-CXR). Five fixed prompt families yield 244,000 model--image--prompt scores. No model leads every cohort and reliability criterion. Prompt-family changes alter AUROC in 21 of 48 multiplicity-controlled comparisons. Replacing healthy controls with sick non-tuberculosis controls reduces AUROC by 0.075--0.306 across all four models. On VinDr-CXR, the three medical models distinguish tuberculosis from no-finding controls substantially better than from pneumonia or lung tumor; their AUROC point estimates for both named diseases fall below 0.5. CheXficient has documented VinDr-CXR pretraining exposure, which limits the interpretation of its results. Thresholds chosen for 95\% sensitivity on TBX11K training retain that constraint by point estimate in only four of sixteen target evaluations. A five-seed supervised source model reaches 0.999 AUROC on TBX11K validation but 0.629 on each of two external cohorts. Conservative exclusion of perceptual-overlap candidates narrows this gap without closing it. These retrospective, single-task results show that discrimination, score reliability and threshold retention support different portability claims. Evidence for chest X-ray tuberculosis screening should identify the complete evaluation specification rather than attribute clinical portability to a checkpoint alone.

0.28

Diagnostic Accuracy and Navigation Behavior of Vision-Language Model Agents Reading Emergency CT and MRI Examinations

cs.AI ·2026-11-17 ·Jonathan Lichtle, Aymen Meddeb, Antonin Birot, Ibrahima Niang, Lisa Gastaud +8 more
similarity 0.65
Abstract

Purpose. To evaluate the diagnostic accuracy and image navigation behavior of vision-language model (VLM) agents under varying exploration strategies. Materials and Methods. In this retrospective study, six VLMs read 100 emergency CT and MRI examinations published in a public archive (March 2025-August 2026) under four conditions (free navigation, navigation from a key slice, and all slices or key slices in a single request), twice each (4800 runs). Nine radiologists read 30 of those cases. A large language model judge validated against two radiologists graded the answers. Conditions were compared with generalized estimating equations clustered by case. Results. Pooled accuracy was lowest under free navigation (32.6%; 391/1200), followed by navigation from a key slice (37.9%; 455/1200; P = .003), and highest with all slices (42.2%; 506/1200) or key slices (42.5%; 510/1200) in one request (both P < .001). On the 30 cases read by radiologists, freely navigating models were correct in 30.0% of runs (108/360) versus 77.0% for radiologists (208/270; P < .001). Models formed a first hypothesis after a median of 10.8% of the slices and kept it in 63.1% of runs (755/1196); final answers were correct in 12.4% of runs after a wrong first hypothesis (110/885) versus 90.4% after a right one (281/311; P < .001). Median stated confidence in the final answers was 90%, whereas 38.9% of them were correct (1861/4778). Conclusion. Across all exploration strategies, VLM agents remained far less accurate than radiologists. They adopted an early hypothesis and usually kept it, seldom correcting a wrong one.

0.20

MIRROR: Multimodal Intelligent Radiology Reasoning and Observation Reporter

cs.CV cs.AIcs.LG ·2026-08-17 ·Vignesh Nagarajan, Sriram Venkatapathy
hot direction similarity 0.63
Abstract · 8 pages, 5 figures, 5 tables, 24 references

A radiologist reading a model's output faces two problems. The model returns a number and no reason, and any system that turns that number into readable prose can quietly add claims the model never made. MIRROR is a research prototype built to separate those failures. It chains a multi-label classifier, a Grad-CAM localizer that turns each positive finding into a named anatomical region, and a report writer that receives the labels, probabilities, and regions but never the image. Because the language layer cannot see pixels, it cannot assert a finding the classifier did not make. We are precise about what that buys: a MIRROR report's findings are auditable against the probability vector, while the sentences framing them are ordinary generated text, and we show one stating a cardiothoracic ratio the system never measured. One registry holds the taxonomy, anatomy, and phrasing for chest X-ray, brain MRI, and head CT, so adding a modality is a data change; all three are routed and tested, one is trained. On ChestMNIST that classifier reaches macro AUROC 0.729 and ranks better than chance on all 14 labels, at 1.6 to 6.8 times the precision a random ranker would get. Yet at the default 0.5 threshold it emits no positive prediction at all for 11 of them, and its excellent-looking Brier score of 0.045 sits beside the 0.047 earned by a predictor that ignores the image. The discrimination is real; the decisions are not. Under the class imbalance normal in radiology, aggregate metrics flatter models that do nothing, and should be reported against that floor.

0.32

Aggregate Accuracy Hides Diagnosis-Specific Failure in Medical Vision-Language Models

eess.IV cs.CLcs.CVcs.LG ·2026-11-11 ·Shreya Ajay Kale, Angad Ripudaman Singh Bajwa
published similarity 0.63
Abstract · Accepted at the NeurIPS 2026 Workshop on Medical Reasoning with Vision Language Foundation Models (Med-Reasoner). 16 pages including NeurIPS…

Medical vision-language models (VLMs) are compared mainly by accuracy averaged across findings, a summary that can hide complete failure on a single diagnosis. We audit five open medical VLMs (MedGemma-4B, Lingshu-7B, HuatuoGPT-Vision-7B, Qwen2.5-VL-7B, and MedVLM-R1) on 6,048 ChestX-ray14 questions balanced by sex, age, finding, and label. On the 432 pneumothorax-positive X-rays, HuatuoGPT-Vision and Qwen2.5-VL detect zero cases while MedGemma and Lingshu detect 38% and 67% of the same images. The two failing models answer "no" to all 864 pneumothorax cases (balanced accuracy 0.500, chance), yet produce fluent, anatomically specific explanations that name the signs of a collapsed lung and then deny them, with no hedge or abstention. This failure is not an artifact of prompting, image resolution, label ambiguity, or model scale. It persists across four prompt formats, at native resolution, and on single-label cases. A within-model control shows the same forced prompt gives HuatuoGPT 79% recall on nodule but only 6% on pneumothorax. It survives a tenfold scale increase (Qwen2.5-VL-72B detects 4%) and replicates on SIIM-ACR, an independent dataset with radiologist-drawn masks, where the failing models detect 0 of 432 confirmed pneumothoraces, including 0 of the 144 largest lesions. Reading the models' logits and internal states shows this is not blindness. The two failing models are highly confident yet no better than chance and a linear probe recovers pneumothorax from their hidden representations even where recall is zero, so the finding is represented internally but suppressed at the output. Aggregate accuracy therefore cannot establish that a medical VLM can see a given finding, because a model that misses one can still describe it convincingly. Reporting per-finding recall and specificity on balanced cases is needed to tell the difference.

0.33

Grounding Radiology Reports in 3D Chest CT: Results of the ReXGrounding Challenge

cs.CV cs.AI ·2026-11-18 ·Mohammed Baharoon, Mahmoud Hussain Alabbad, Sung Eun Kim, Xiaoman Zhang, Lucas Bijnens +57 more
benchmark similarity 0.63
Abstract · 25 pages, 13 figures, 4 tables

Segmenting each reported finding in a radiology scan would allow findings to be measured and tracked over time and let AI systems generate reports that are verifiable, but so far AI models have performed poorly at this task. To advance this task, we organized the ReXGrounding Challenge at MICCAI 2026, the first challenge dedicated to it. Given a non-contrast chest CT scan and the set of findings from its report, participants trained models to produce the corresponding set of 3D segmentations. The challenge used 2,992 training and 200 validation scans from the ReXGroundingCT dataset, and evaluated methods on a held-out test set of 300 scans with 582 findings, exhaustively annotated by board-certified radiologists. In total, 48 teams from 15 countries made 760 submissions, and the best method reached a Dice of 0.375 and a hit rate of 0.77, matching agreement between two independent radiologist groups (Dice 0.32, hit rate 0.76, on a 50-scan subset). On the 100 scans of the pre-challenge benchmark, the winner reached a Dice of 0.390, against 0.285 for VoxTell, the best model before the challenge, which five of the six best teams fine-tuned. Non-focal findings remained far harder to segment than focal ones, instance F1 stayed below inter-reader agreement (0.34 vs. 0.47), and models sometimes segmented the right abnormality in the wrong location. Top methods thus match radiologist agreement in Dice, but non-focal findings, findings with multiple instances, and adherence to the anatomical location described in the text remain open problems.

0.32

Single-Pass Decision Scores Enable Rapid Classification with Adjustable Thresholds in Medical Multimodal Large Language Models

cs.CV ·2026-10-14 ·Patrick Wienholt, Frederik Hauke, Christiane Kuhl, Jakob Nikolas Kather, Sven Nebelung +1 more
code/data similarity 0.63
Abstract · 29 pages (18 pages main text, 11 pages Supplementary Information), 5 figures, 3 tables

Multimodal large language models (MLLMs) answer binary clinical questions with a yes or no token, leaving the decision threshold implicit and fixed. We derive a continuous score from a single forward pass by renormalizing the probabilities of the yes and no tokens, allowing the threshold to be adapted to clinical needs without retraining. We evaluated this approach with MedGemma and Gemma-3 (4B and 27B) on six medical imaging datasets. The default threshold was frequently misaligned with the task: for identifying normal chest radiographs, MedGemma-27B labeled every image as abnormal, whereas a validation-selected threshold yielded a sensitivity of 0.945 and a specificity of 0.696. Normalization achieved the highest AUROC on four of six datasets (CheXpert: 0.819 vs. 0.777 for raw and 0.743 for text-elicited probabilities), and a single decision required 53-79 ms on one GPU. This simple post-hoc method turns medical MLLMs into fast classifiers with adjustable operating points. Code: https://github.com/TruhnLab/llm-threshold-calibration

0.45

The Value of System 1 Models in Medicine

cs.LG ·2026-10-22 ·Xiufeng Yang, Konstantinos Vrettos, Zeineb Ben Chaaben, Fabian Drexel, Jannik Lübberstedt +15 more
similarity 0.61
Abstract · 27 pages, 6 figures; includes Supplementary Appendix (3 figures, 5 tables)

Many clinical decisions are a choice among a few fixed options, taken quickly and in large numbers. Such decisions also need an uncertainty estimate to know when to defer to a clinician. Generative language models answer slowly in free text and state their confidence poorly. In contrast, System 1 models answer zero-shot with a probability for each answer. However, their performance across clinical tasks is unknown. Four System 1 models, two proprietary and two with open weights, were evaluated zero-shot on 86 public tasks from 14 clinical domains in 20 languages, spanning examination questions and medical imaging. Tasks were assigned to six capability tiers before analysis. The primary outcome was the area under the receiver-operating-characteristic curve (AUROC). Secondary outcomes included calibration, language effects and comparisons with published results and generative models. Across 179,111 cases, the mean AUROC of the best model per task was 0.94 for medical knowledge, 0.93 for text understanding, 0.83 for clinical judgement from text, 0.89 for image perception, 0.84 for 2D image findings and 0.69 for volumetric findings. Imaging tasks scored 0.09 (95% CI, 0.06 to 0.11) lower than text tasks (P < 0.001). The best model matched or exceeded the best published result on 13 of 26 text tasks and on 8 of 35 imaging tasks. Triage nurses outperformed the best model (accuracy, 0.85 vs. 0.56). One decision took 0.34 to 0.44 seconds and 24 to 81 joules on open-weight models run locally. Accuracy on identical questions fell by up to 39 percentage points from English to Yoruba. Generative models of the same family were 11 to 76 times slower, with 3 to 5 percentage points higher balanced accuracy. System 1 models decide quickly, cheaply and with usable confidence when the answer is stated in a text or recalled from medical knowledge, but not when it must be judged or read from an image.

0.52