Aggregate Accuracy Hides Diagnosis-Specific Failure in Medical Vision-Language Models

Shreya Ajay Kale, Angad Ripudaman Singh Bajwa

eess.IV cs.CLcs.CVcs.LG ·submitted 2026-11-11 03:35 UTC · v1
published

Abstract

Medical vision-language models (VLMs) are compared mainly by accuracy averaged across findings, a summary that can hide complete failure on a single diagnosis. We audit five open medical VLMs (MedGemma-4B, Lingshu-7B, HuatuoGPT-Vision-7B, Qwen2.5-VL-7B, and MedVLM-R1) on 6,048 ChestX-ray14 questions balanced by sex, age, finding, and label. On the 432 pneumothorax-positive X-rays, HuatuoGPT-Vision and Qwen2.5-VL detect zero cases while MedGemma and Lingshu detect 38% and 67% of the same images. The two failing models answer "no" to all 864 pneumothorax cases (balanced accuracy 0.500, chance), yet produce fluent, anatomically specific explanations that name the signs of a collapsed lung and then deny them, with no hedge or abstention. This failure is not an artifact of prompting, image resolution, label ambiguity, or model scale. It persists across four prompt formats, at native resolution, and on single-label cases. A within-model control shows the same forced prompt gives HuatuoGPT 79% recall on nodule but only 6% on pneumothorax. It survives a tenfold scale increase (Qwen2.5-VL-72B detects 4%) and replicates on SIIM-ACR, an independent dataset with radiologist-drawn masks, where the failing models detect 0 of 432 confirmed pneumothoraces, including 0 of the 144 largest lesions. Reading the models' logits and internal states shows this is not blindness. The two failing models are highly confident yet no better than chance and a linear probe recovers pneumothorax from their hidden representations even where recall is zero, so the finding is represented internally but suppressed at the output. Aggregate accuracy therefore cannot establish that a medical VLM can see a given finding, because a model that misses one can still describe it convincingly. Reporting per-finding recall and specificity on balanced cases is needed to tell the difference.

Comment
Accepted at the NeurIPS 2026 Workshop on Medical Reasoning with Vision Language Foundation Models (Med-Reasoner). 16 pages including NeurIPS checklist, 1 figure, 5 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Beyond Benchmark Scores: Auditing Medical Vision-Language Models for Chest X-Ray Tuberculosis Screening

cs.CV cs.LG ·2026-09-18 ·Mushir Akhtar, M. Tanveer, Mohd. Arshad
benchmark similarity 0.71
Abstract · 27 pages, 7 figures, and 21 tables; includes extended methods, statistical analyses, and robustness evaluations

A medical model's benchmark score does not establish that the same conclusion holds under a different evaluation. This study tests whether claims about model ranking, score reliability and screening performance survive changes in cohort, prompt, negative spectrum, specified prevalence and operating threshold. We audit three medical vision-language models (BioMedCLIP, CheXficient, and MedSigLIP) and a general-domain OpenCLIP comparator on 12,200 chest radiograph records from four datasets (Montgomery, Shenzhen, TBX11K, and VinDr-CXR). Five fixed prompt families yield 244,000 model--image--prompt scores. No model leads every cohort and reliability criterion. Prompt-family changes alter AUROC in 21 of 48 multiplicity-controlled comparisons. Replacing healthy controls with sick non-tuberculosis controls reduces AUROC by 0.075--0.306 across all four models. On VinDr-CXR, the three medical models distinguish tuberculosis from no-finding controls substantially better than from pneumonia or lung tumor; their AUROC point estimates for both named diseases fall below 0.5. CheXficient has documented VinDr-CXR pretraining exposure, which limits the interpretation of its results. Thresholds chosen for 95\% sensitivity on TBX11K training retain that constraint by point estimate in only four of sixteen target evaluations. A five-seed supervised source model reaches 0.999 AUROC on TBX11K validation but 0.629 on each of two external cohorts. Conservative exclusion of perceptual-overlap candidates narrows this gap without closing it. These retrospective, single-task results show that discrimination, score reliability and threshold retention support different portability claims. Evidence for chest X-ray tuberculosis screening should identify the complete evaluation specification rather than attribute clinical portability to a checkpoint alone.

0.28

Same Evidence, Different Verdicts: Delivery of CT Images and DICOM Metadata Changes VLM Quality-Control Decisions

cs.CV ·2026-11-13 ·Nicolas Avelar
code/data similarity 0.71
Abstract · 4 pages, 2 figures, 1 table. Submitted to IEEE ISBI 2027

Vision-language models (VLMs) are being proposed as automated checks on clinical imaging inputs, where a scan and its DICOM metadata can disagree; a truncated CT series wrongly admitted to volumetric follow-up, such as lung-nodule growth assessment in screening, biases the measurement. A natural safeguard is to let the model judge the image before it sees the metadata. We find this backfires. On 60 NLST chest CT pairs with coverage defects whose ground truth is computed from scan geometry, a false header that Claude Haiku 5.5 resisted when shown with the image (2% of its detections overruled) overturned 91% of them when it arrived after the model's answer (Nemotron-3.5-VL 43% to 100%). With the order reversed, the image overturned 98-100% of the header's errors (Claude models): whichever source came second won. This is not generic sycophancy: a neutral "please confirm" reversed 0 of 1,072 correct refusals, and the effect persisted when the header arrived as a tool result, as in agentic pipelines. One warning sentence cut sequential reversal to at most 9%, and the pattern held on 24 real mismatched pairs. Contributions: (i) evidence that VLM input-check decisions on identical evidence depend on delivery; (ii) a testbed with exact geometric ground truth; (iii) a validation protocol for clinical VLM input checks. Code, prompts and all call logs: https://github.com/nav92061/ct-vlm-delivery-order

0.30

FZ-VLM: A Two Stage Florence-Zephyr Vision Language Model Framework for Pulmonary Nodule Characterization and Clinical Decision Making

cs.CV cs.AI ·2026-08-15 ·Pramit Dutta, Jenita Manokaran, Richa Mittal, Ryan Appleby, Eranga Ukwatta
similarity 0.65
Abstract

Lung cancer remains one of the leading causes of cancer-related mortality worldwide, and Computed Tomography (CT) is a primary imaging tool for screening and followup assessment. After pulmonary nodule detection, radiologists manually assess anatomical location, diameter, margin characteristics, and attenuation type to support risk assessment and clinical decision-making. However, this post-detection workflow is time-consuming and can be affected by inter-observer variability. Existing Artificial Intelligence methods often focus on isolated tasks, limiting their use as a unified, clinically grounded interpretation framework. This study presents FZ-VLM, a two-stage Florence-Zephyr Vision Language Model framework for unified structured pulmonary nodule characterization in lung CT. The framework uses a fine-tuned Florence-2 model to extract radiological attributes from expert-annotated 2D axial CT slices, while a Zephyr-7B model uses these attributes to generate nodule descriptions, follow-up recommendations, and longitudinal analyses. Results showed that the Stage 1 model achieved 77.18\% accuracy for anatomical location, 67.96\% accuracy for margin characteristics, and 79.13\% accuracy for attenuation type, with a Mean Absolute Error of 2.58 mm for diameter estimation, outperforming evaluated GPT-4-based baselines as well as the human baseline. Expert radiologist evaluation of Stage 2 showed 93.9\% accuracy, 98.6\% completeness score, 76.1\% clinical relevance, and an overall score of 89.5\%. Safety analysis showed that most outputs were clinically safe, although some follow-up recommendations still required expert review. To the best of our knowledge, this study presents the first two-stage Vision-Language Model framework for structured nodule characterization and clinical decision-making.

0.04

Uncertainty, Not Concealment: A Mechanistic Reappraisal of Sycophancy in Vision-Language Models

cs.CV cs.LG ·2026-11-06 ·Mohamed I. Eldagla, Zeyad H. ElShafei, Ahmed M. Anter
publishedcode/data similarity 0.65
Abstract · Accepted to the NeurIPS 2026 Med-Reasoner Workshop

Vision-language models (VLMs) in medical retrieval-augmented generation must be able to say when a retrieved report contradicts the X-ray, so understanding whether they can detect such conflicts is important for safe deployment. The sycophancy mask hypothesis holds that these models internally detect conflicts but refuse to report them, concealing a detected contradiction. We introduce a three-part diagnostic that separates concealment from uncertainty: representation probing, activation steering, and two-way forced choice. Across four instruction-tuned VLMs on chest X-rays, we confirm behavioral suppression of contradiction and find that a linear probe separates matched from mismatched inputs, beyond what a simple CLIP model achieves. Steering the learned conflict direction never elicits contradiction, and forcing a binary choice does not recover one; instead, cross-modal attention to the image drops on mismatched pairs. We conclude that these models fail to contradict because the mismatch registers as hedged, gated uncertainty rather than concealed knowledge, calling for re-grounding and uncertainty surfacing. Code is available at https://github.com/mohamed-eldagla/Uncertainty-Not-Concealment/.

0.31

Visual Harness Scales General VLMs to Medical Images

cs.CV ·2026-11-17 ·Shaowen Wan, Hanqi Jiang, Zihao Wu, Junhao Chen, Weihang You +4 more
similarity 0.64
Abstract

We show that an appropriate visual harness can substantially improve the performance of general vision-language models (VLMs) across diverse medical imaging tasks. We introduce VERA, a medical visual harness that equips general VLMs with interactive visual tools and systematic diagnostic evidence management. With VERA, general VLMs interactively explore medical images and progressively acquire diagnostic evidence, which is preserved in a lossless memory for subsequent retrieval and use. After submitting an initial answer, the VLM receives an assessment of potential omissions and the reliability of identified findings. This assessment guides further image inspection and measurement, followed by answer revision in an iterative agentic loop until sufficient evidence is obtained. Across 11 tasks and four imaging modalities, VERA improves performance on all tasks with Qwen3.8-27B, with notable gains in spleen measurement (63.3% to 98.3%), renal search (57.5% to 71.2%), and pulmonary nodule detection (0.0% to 28.2%). High-capability API-based VLMs achieve even higher performance with VERA. For example, GPT-6.1 Sol improves pulmonary nodule detection from 10.8% to 69.2% with VERA, demonstrating the complementary benefits of stronger model capabilities and an effective medical visual harness. Our results highlight the potential of visual harnesses as a new paradigm for scaling general VLMs to medical imaging tasks.

0.29

Zero-shot evaluation of open vision-language models as System 1 decision models on radiology tasks

cs.CV cs.AI ·2026-11-01 ·Bradley J Erickson, Sara Salehi
similarity 0.63
Abstract · 22 pages, 3 tables, 2 figures

Purpose: We compared two multimodal System 1 decision models, Clef 27B and d1 3B, with a traditional LLM (Qwen 3.8-27B) on seven radiology tasks covering text, radiographs, CT and MRI. Methods: Three models were compared: Clef, Qwen3.8-27B and d1. Three tasks were interpretation of text and 4 were detection of finding in images. The tasks were: 1. finding presence of finding in CT-RATE chest CT reports; 2. Presence of finding in PadChest chest radiograph reports; 3. the same 18 findings on CT-RATE chest CT but 3D volumes; 4. MR safety status of devices from AccessGUDID device records; 5. line and tube position on RANZCR CLiP chest radiographs; 6. motion-artifact severity on MR-ART T1-weighted brain MRI and 7. sequence identification on BraTS 2021 brain MRI. The primary endpoint was AUROC. There was no fine-tuning of the models on the tasks. Results: All models completed all tests without a failed request. All retrieved findings from reports almost perfectly (AUROC >0.95). Clef ranked higher than its Qwen backbone on CT-RATE volumes and RANZCR lower on MR-ART. The two did not differ on BraTS, GUDID or PadChest, and differed by 0.002 on CT-RATE reports. On BraTS, Clef correctly identified 90 of 100 FLAIR volumes while Qwen never chose it. d1 ranked lower than Clef on six of seven tasks. No model performed well on motion severity. Clef was faster per request than Qwen on tasks with many questions per input. d1 used 3 to 9 times less energy per request than Clef. Conclusions: System 1 models can perform important tasks in radiology with high accuracy, at lower compute cost than LLMs used in the usual way. When an LLM is constrained to a single answer token, its cost and performance is similar to System 1 models unless multiple questions are asked. A 3B System 1 model was close to the 27B models on report text but not on images. No model performed well on motion severity.

0.25

Retrieval-Grounded Multi-View Reasoning for Clinically Reliable Radiology Report Generation

cs.CV ·2026-11-03 ·Wanshu Fan, Zeyu Wang, Zheng Tong, Qi Ai, Wencai Weng +6 more
similarity 0.63
Abstract

Chest radiograph report generation is hampered by retrieved reports that resemble the current image but are clinically inconsistent with it, and by diagnostic-label imbalance. We present RG-MVR, a retrieval-grounded framework comprising Retrieval-Augmented Evidence Grounding, which combines dense memory summaries with visually gated sparse retrieved evidence; Adaptive Multi-view Evidential Reasoning, which weights image, memory, and retrieved evidence per case; and a Clinical Prompt Learner, which models finding mention separately from positive, negative, or uncertain status. On MIMIC-CXR, RG-MVR achieved a clinical-label F1 of 0.483 and a BLEU-4 of 0.118 (IU X-ray: 0.202 and 0.110). In an exploratory external cohort of 22 examinations, clinical-label agreement declined markedly (F1, 0.071) and unsupported statements remained common, although physicians found fewer unsupported temporal comparisons (9 vs. 20 cases) and device-related statements (7 vs. 15) than with the baseline. Evidence-aware retrieval and structured diagnostic prompting may reduce specific reporting errors, but broader external validation is required.

0.22

Diagnostic Loss: Asymmetric Supervision for Radiology Report Generation

cs.CV cs.LG ·2026-10-22 ·Ignacy Kolton, Wenxuan Li, Zongwei Zhou, Jarosław B. Ćwikła, Arkadiusz Sitek +2 more
code/datahot direction similarity 0.63
Abstract · 26 pages, 6 figures, 7 tables. Code available at https://github.com/gmum/DLoss

Automated radiology report generation requires models to do more than produce fluent clinical narratives: they must explicitly state supported diagnoses while avoiding unsupported ones. However, existing medical vision-language models (MedVLMs) are typically trained with token-level maximum likelihood objectives, which prioritize text agreement over diagnostically critical terms. As a result, models can miss key diagnoses and introduce wrong ones. We identify this as an objective misalignment between conventional language modeling and the asymmetric diagnostic requirements of radiology reporting. To encode these requirements, we introduce Diagnostic Loss (DLoss), a differentiable, architecture-agnostic objective that operates directly on decoder token probabilities. DLoss separately aggregates probability mass over vocabularies associated with diagnoses supported by the reference report and with unsupported alternatives. Using asymmetric pooling across token positions in the report, it encourages supported diagnoses to receive sufficient probability in at least one position while suppressing spurious probability spikes for unsupported diagnoses across all positions during training. The loss can be applied to existing 3D MedVLMs without modifying their vision backbones, language decoders, or inference procedures, and introduces no additional inference-time computation. We train and evaluate DLoss on 50,000 abdominal CT scans across several 3D MedVLM architectures on both in-distribution and out-of-distribution report-generation benchmarks. Across these settings, DLoss improves diagnostic faithfulness while maintaining competitive performance on conventional language-generation metrics, showing the value of asymmetric sequence-level supervision for radiology report generation. The code for DLoss is available at https://github.com/gmum/DLoss.

0.40