Same Evidence, Different Verdicts: Delivery of CT Images and DICOM Metadata Changes VLM Quality-Control Decisions

Nicolas Avelar

cs.CV ·submitted 2026-11-13 01:10 UTC · v1
code/data

Abstract

Vision-language models (VLMs) are being proposed as automated checks on clinical imaging inputs, where a scan and its DICOM metadata can disagree; a truncated CT series wrongly admitted to volumetric follow-up, such as lung-nodule growth assessment in screening, biases the measurement. A natural safeguard is to let the model judge the image before it sees the metadata. We find this backfires. On 60 NLST chest CT pairs with coverage defects whose ground truth is computed from scan geometry, a false header that Claude Haiku 5.5 resisted when shown with the image (2% of its detections overruled) overturned 91% of them when it arrived after the model's answer (Nemotron-3.5-VL 43% to 100%). With the order reversed, the image overturned 98-100% of the header's errors (Claude models): whichever source came second won. This is not generic sycophancy: a neutral "please confirm" reversed 0 of 1,072 correct refusals, and the effect persisted when the header arrived as a tool result, as in agentic pipelines. One warning sentence cut sequential reversal to at most 9%, and the pattern held on 24 real mismatched pairs. Contributions: (i) evidence that VLM input-check decisions on identical evidence depend on delivery; (ii) a testbed with exact geometric ground truth; (iii) a validation protocol for clinical VLM input checks. Code, prompts and all call logs: https://github.com/nav92061/ct-vlm-delivery-order

Comment
4 pages, 2 figures, 1 table. Submitted to IEEE ISBI 2027

Closest papers

Nearest neighbours by meaning across the whole index.

Aggregate Accuracy Hides Diagnosis-Specific Failure in Medical Vision-Language Models

eess.IV cs.CLcs.CVcs.LG ·2026-11-11 ·Shreya Ajay Kale, Angad Ripudaman Singh Bajwa
published similarity 0.71
Abstract · Accepted at the NeurIPS 2026 Workshop on Medical Reasoning with Vision Language Foundation Models (Med-Reasoner). 16 pages including NeurIPS…

Medical vision-language models (VLMs) are compared mainly by accuracy averaged across findings, a summary that can hide complete failure on a single diagnosis. We audit five open medical VLMs (MedGemma-4B, Lingshu-7B, HuatuoGPT-Vision-7B, Qwen2.5-VL-7B, and MedVLM-R1) on 6,048 ChestX-ray14 questions balanced by sex, age, finding, and label. On the 432 pneumothorax-positive X-rays, HuatuoGPT-Vision and Qwen2.5-VL detect zero cases while MedGemma and Lingshu detect 38% and 67% of the same images. The two failing models answer "no" to all 864 pneumothorax cases (balanced accuracy 0.500, chance), yet produce fluent, anatomically specific explanations that name the signs of a collapsed lung and then deny them, with no hedge or abstention. This failure is not an artifact of prompting, image resolution, label ambiguity, or model scale. It persists across four prompt formats, at native resolution, and on single-label cases. A within-model control shows the same forced prompt gives HuatuoGPT 79% recall on nodule but only 6% on pneumothorax. It survives a tenfold scale increase (Qwen2.5-VL-72B detects 4%) and replicates on SIIM-ACR, an independent dataset with radiologist-drawn masks, where the failing models detect 0 of 432 confirmed pneumothoraces, including 0 of the 144 largest lesions. Reading the models' logits and internal states shows this is not blindness. The two failing models are highly confident yet no better than chance and a linear probe recovers pneumothorax from their hidden representations even where recall is zero, so the finding is represented internally but suppressed at the output. Aggregate accuracy therefore cannot establish that a medical VLM can see a given finding, because a model that misses one can still describe it convincingly. Reporting per-finding recall and specificity on balanced cases is needed to tell the difference.

0.33

Seeing Through the Forgery Is Not Enough: Regressive Sycophancy under Fabricated Evidence in Medical Vision-Language Models

cs.CL cs.AI ·2026-10-13 ·Sadif Ahmed, Soumya Swagata Biswas, Rifat Shahriyar, Chowdhury Mohammad Rakin Haider
similarity 0.66
Abstract · 16 pages, 5 figures, 14 tables. Sadif Ahmed and Soumya Swagata Biswas contributed equally. Code and data: https://anonymous.4open.science/r/…

A medical vision-language model may analyze a given CT scan and correctly detect both kidneys in view. Continuing this conversation, if a user provides a prescription with an opposite direction, medical VLMs often sycophantically choose to realign their diagnosis. In this work, we study regressive sycophancy under fabricated evidence, where a model abandons a correct answer when pushback comes with a fake document. We test four open VLMs on 400 VQA-RAD yes/no questions in 19,200 multi-turn conversations, with and without a fabricated prescription. Without a disclosure that documents are synthetic, the models abandon 80.1% of 6,488 correct answers. Notably, under one script each, the same prescription raises the flip rate of Qwen2.5-VL-7B from 45.9% to 89.6% and lowers that of Qwen3-VL-8B from 77.7% to 50.9%. A model rejected the prescription while still preserving the correct answer in 915 of 3,232 conversations with the prescription (28.3%), and 40% of these flipped in later turns. System-prompt sentences that disclose the documents as synthetic lower one model's flip rate from 77.8% to 47.3%. Thus, we conclude that awareness about a forgery does not prevent a model from adopting its answer.

0.54

Uncertainty, Not Concealment: A Mechanistic Reappraisal of Sycophancy in Vision-Language Models

cs.CV cs.LG ·2026-11-06 ·Mohamed I. Eldagla, Zeyad H. ElShafei, Ahmed M. Anter
publishedcode/data similarity 0.63
Abstract · Accepted to the NeurIPS 2026 Med-Reasoner Workshop

Vision-language models (VLMs) in medical retrieval-augmented generation must be able to say when a retrieved report contradicts the X-ray, so understanding whether they can detect such conflicts is important for safe deployment. The sycophancy mask hypothesis holds that these models internally detect conflicts but refuse to report them, concealing a detected contradiction. We introduce a three-part diagnostic that separates concealment from uncertainty: representation probing, activation steering, and two-way forced choice. Across four instruction-tuned VLMs on chest X-rays, we confirm behavioral suppression of contradiction and find that a linear probe separates matched from mismatched inputs, beyond what a simple CLIP model achieves. Steering the learned conflict direction never elicits contradiction, and forcing a binary choice does not recover one; instead, cross-modal attention to the image drops on mismatched pairs. We conclude that these models fail to contradict because the mismatch registers as hedged, gated uncertainty rather than concealed knowledge, calling for re-grounding and uncertainty surfacing. Code is available at https://github.com/mohamed-eldagla/Uncertainty-Not-Concealment/.

0.31

FZ-VLM: A Two Stage Florence-Zephyr Vision Language Model Framework for Pulmonary Nodule Characterization and Clinical Decision Making

cs.CV cs.AI ·2026-08-15 ·Pramit Dutta, Jenita Manokaran, Richa Mittal, Ryan Appleby, Eranga Ukwatta
similarity 0.62
Abstract

Lung cancer remains one of the leading causes of cancer-related mortality worldwide, and Computed Tomography (CT) is a primary imaging tool for screening and followup assessment. After pulmonary nodule detection, radiologists manually assess anatomical location, diameter, margin characteristics, and attenuation type to support risk assessment and clinical decision-making. However, this post-detection workflow is time-consuming and can be affected by inter-observer variability. Existing Artificial Intelligence methods often focus on isolated tasks, limiting their use as a unified, clinically grounded interpretation framework. This study presents FZ-VLM, a two-stage Florence-Zephyr Vision Language Model framework for unified structured pulmonary nodule characterization in lung CT. The framework uses a fine-tuned Florence-2 model to extract radiological attributes from expert-annotated 2D axial CT slices, while a Zephyr-7B model uses these attributes to generate nodule descriptions, follow-up recommendations, and longitudinal analyses. Results showed that the Stage 1 model achieved 77.18\% accuracy for anatomical location, 67.96\% accuracy for margin characteristics, and 79.13\% accuracy for attenuation type, with a Mean Absolute Error of 2.58 mm for diameter estimation, outperforming evaluated GPT-4-based baselines as well as the human baseline. Expert radiologist evaluation of Stage 2 showed 93.9\% accuracy, 98.6\% completeness score, 76.1\% clinical relevance, and an overall score of 89.5\%. Safety analysis showed that most outputs were clinically safe, although some follow-up recommendations still required expert review. To the best of our knowledge, this study presents the first two-stage Vision-Language Model framework for structured nodule characterization and clinical decision-making.

0.04

Zero-shot evaluation of open vision-language models as System 1 decision models on radiology tasks

cs.CV cs.AI ·2026-11-01 ·Bradley J Erickson, Sara Salehi
similarity 0.61
Abstract · 22 pages, 3 tables, 2 figures

Purpose: We compared two multimodal System 1 decision models, Clef 27B and d1 3B, with a traditional LLM (Qwen 3.8-27B) on seven radiology tasks covering text, radiographs, CT and MRI. Methods: Three models were compared: Clef, Qwen3.8-27B and d1. Three tasks were interpretation of text and 4 were detection of finding in images. The tasks were: 1. finding presence of finding in CT-RATE chest CT reports; 2. Presence of finding in PadChest chest radiograph reports; 3. the same 18 findings on CT-RATE chest CT but 3D volumes; 4. MR safety status of devices from AccessGUDID device records; 5. line and tube position on RANZCR CLiP chest radiographs; 6. motion-artifact severity on MR-ART T1-weighted brain MRI and 7. sequence identification on BraTS 2021 brain MRI. The primary endpoint was AUROC. There was no fine-tuning of the models on the tasks. Results: All models completed all tests without a failed request. All retrieved findings from reports almost perfectly (AUROC >0.95). Clef ranked higher than its Qwen backbone on CT-RATE volumes and RANZCR lower on MR-ART. The two did not differ on BraTS, GUDID or PadChest, and differed by 0.002 on CT-RATE reports. On BraTS, Clef correctly identified 90 of 100 FLAIR volumes while Qwen never chose it. d1 ranked lower than Clef on six of seven tasks. No model performed well on motion severity. Clef was faster per request than Qwen on tasks with many questions per input. d1 used 3 to 9 times less energy per request than Clef. Conclusions: System 1 models can perform important tasks in radiology with high accuracy, at lower compute cost than LLMs used in the usual way. When an LLM is constrained to a single answer token, its cost and performance is similar to System 1 models unless multiple questions are asked. A 3B System 1 model was close to the 27B models on report text but not on images. No model performed well on motion severity.

0.25

Multimodal Error Detection in Chest X-ray Reports: A Large Language Model Reading Image Evidence

cs.CL ·2026-11-19 ·Yanda Cheng, Bo Wen, Yuhao Lu
similarity 0.60
Abstract · 34 pages, 4 figures, including supplementary material

Rad-Linter checks chest X-ray reports against image-derived evidence to flag potential errors for review. A pretrained image classifier supplies scores for nine pathologies, and a 1.5B-parameter language model, fine-tuned with LoRA on 1,816 examples, checks their consistency with the report. We compare it with a keyword-and-negation rule baseline given the same reports and scores. Evaluation uses controlled report-score pairings from OpenI, with consistency labels derived from automatic report labels and score thresholds. Each counterfactual quad crosses two real reports with two real score vectors from other patients, creating two consistent and two inconsistent pairs. Every report and score vector occurs in both conditions, so either input alone permits only 50% accuracy. On 131 quads, Rad-Linter achieves 98.5% pair accuracy versus 80.5% for the rule baseline, and classifies all four pairs correctly in 94.4% of quads versus 56.5%. The checkers perform similarly on omission items, including unmentioned and negated findings; larger differences occur on the remaining item types, which require interpreting how findings are described. The same language model without fine-tuning remains near 50% accuracy. On a second set of 181 quads that also includes reports on which the automatic labelers disagree, pair accuracy is 93.4% versus 75.3%. These controlled results show that, given the same image-derived scores, a trained language model detects report-score inconsistencies more accurately than the tested rule baseline, with the advantage concentrated in interpreting how findings are worded.

0.28

ModaLens: Measuring Image Sensitivity in Report-Conditioned Medical VLMs

cs.CV cs.AI ·2026-09-14 ·Sebastián Andrés Cajas Ordóñez, Maximin Lange, Quang Bui, Anqi Peter Li, Felipe Ocampo Osorio +7 more
code/data similarity 0.60
Abstract

A radiology report can already answer a clinical question, so it is hard to tell whether a vision-language model also uses the image. ModaLens, a paired image-swap audit, measures how report availability changes image sensitivity: MedGemma-27B on 3,199 paired MIMIC-CXR cases from 293 patients, all 14 questions per case (13 finding-specific and one composite), each image replaced by one from another study, usually of the same patient, with question and report fixed. Under an explicit answer instruction, the model's generated answer changes on 4.26 percent of trials with the report and 20.94 percent without it, a paired increase of 16.7 points (patient-clustered 95 percent CI 15.6 to 17.7), so report availability reduces image-swap sensitivity under this protocol; the original prompt with a lowercase first-token readout gives 4.70 percent against 17.07 percent, and substitutions also move continuous answer scores where the binary prediction does not change. The labels are derived from reports, which limits conclusions about visual correctness; the direction replicates in two further model lineages. Code, the exact prompts and a run record for every number are at https://github.com/criticaldata/MODALENS.

0.67

Seeing Is Not Believing: Counterfactual Lesion Erasure Teaches a Small Medical Vision-Language Agent to Report Only What the Image Shows

cs.AI cs.CLcs.CV ·2026-11-08 ·Bhaskar Gurram
code/data similarity 0.60
Abstract · 28 pages, 1 figure, 13 tables. Preprint v1.0; reader study in progress. Code, data recipes, pre-registrations and per-view outputs: https://…

Medical vision-language models (VLMs) often report a finding because the question names it; standard benchmarks miss this. From public segmentation datasets we build counterfactual views without manual annotation: the lesion erased by inpainting, a same-shape control edit elsewhere, and unedited lesion-free images. The evidence sensitivity gap (ESG) is the rate of absent-or-refer answers after erasure minus the rate after the control edit; it is zero for a model that ignores the image or reacts to both edits alike. MedScope-4B (Qwen3.5-4B, LoRA, image tools) was trained on label-derived trajectories, selected by a pre-registered rule and tested once against nine frontier and six open VLMs; four pre-registered checks then probed the mechanism. On 507 internal cases across five imaging types, MedScope-4B reached ESG 0.758 and claimed an erased lesion in 9.6% of cases, against 0.27-0.47 and 41-62% for the frontier models (all p<0.001), without significant loss of accuracy on real lesions. Without counterfactual views ESG fell to 0.279+-0.107 (three seeds); the effect replicated on MedGemma 1.5 4B and two unseen inpainting tools. At four external centres the advantage held but frontier models detected more real lesions; on a fresh external test MedScope-4B detected 0 of 48 pneumothorax films, with net utility below gemini-4-argon's (-0.36 [-0.50, -0.23]). Matching the control edit was not shown to matter; over three seeds no fresh-external ESG advantage over removal-based DPO was established; a paired-view consistency objective did not beat a matched-compute control, while that continuation alone cut erased-lesion claims on unseen tools at every seed, at a cost in sensitivity at one. Training on erased and edited images gives a small model an evidence-gated disposition that prompting does not give frontier models; it does not improve perception, and rare critical findings need coverage.

0.30