CS Paper Radar

Diagnostic Accuracy and Navigation Behavior of Vision-Language Model Agents Reading Emergency CT and MRI Examinations

Jonathan Lichtle, Aymen Meddeb, Antonin Birot, Ibrahima Niang, Lisa Gastaud, Riyad Hanafi, Sofiane Dujardin, Corentin Selomme, Guillaume Cachard, Aghiles Hamroun, Grégory Kuchcinski, Su Hwan Kim, Bastien Le Guellec

cs.AI ·submitted 2026-11-17 20:32 UTC · v1

Abstract

Purpose. To evaluate the diagnostic accuracy and image navigation behavior of vision-language model (VLM) agents under varying exploration strategies. Materials and Methods. In this retrospective study, six VLMs read 100 emergency CT and MRI examinations published in a public archive (March 2025-August 2026) under four conditions (free navigation, navigation from a key slice, and all slices or key slices in a single request), twice each (4800 runs). Nine radiologists read 30 of those cases. A large language model judge validated against two radiologists graded the answers. Conditions were compared with generalized estimating equations clustered by case. Results. Pooled accuracy was lowest under free navigation (32.6%; 391/1200), followed by navigation from a key slice (37.9%; 455/1200; P = .003), and highest with all slices (42.2%; 506/1200) or key slices (42.5%; 510/1200) in one request (both P < .001). On the 30 cases read by radiologists, freely navigating models were correct in 30.0% of runs (108/360) versus 77.0% for radiologists (208/270; P < .001). Models formed a first hypothesis after a median of 10.8% of the slices and kept it in 63.1% of runs (755/1196); final answers were correct in 12.4% of runs after a wrong first hypothesis (110/885) versus 90.4% after a right one (281/311; P < .001). Median stated confidence in the final answers was 90%, whereas 38.9% of them were correct (1861/4778). Conclusion. Across all exploration strategies, VLM agents remained far less accurate than radiologists. They adopted an early hypothesis and usually kept it, seldom correcting a wrong one.

Closest papers

Nearest neighbours by meaning across the whole index.

Zero-shot evaluation of open vision-language models as System 1 decision models on radiology tasks

cs.CV cs.AI ·2026-11-01 ·Bradley J Erickson, Sara Salehi
similarity 0.65
Abstract · 22 pages, 3 tables, 2 figures

Purpose: We compared two multimodal System 1 decision models, Clef 27B and d1 3B, with a traditional LLM (Qwen 3.8-27B) on seven radiology tasks covering text, radiographs, CT and MRI. Methods: Three models were compared: Clef, Qwen3.8-27B and d1. Three tasks were interpretation of text and 4 were detection of finding in images. The tasks were: 1. finding presence of finding in CT-RATE chest CT reports; 2. Presence of finding in PadChest chest radiograph reports; 3. the same 18 findings on CT-RATE chest CT but 3D volumes; 4. MR safety status of devices from AccessGUDID device records; 5. line and tube position on RANZCR CLiP chest radiographs; 6. motion-artifact severity on MR-ART T1-weighted brain MRI and 7. sequence identification on BraTS 2021 brain MRI. The primary endpoint was AUROC. There was no fine-tuning of the models on the tasks. Results: All models completed all tests without a failed request. All retrieved findings from reports almost perfectly (AUROC >0.95). Clef ranked higher than its Qwen backbone on CT-RATE volumes and RANZCR lower on MR-ART. The two did not differ on BraTS, GUDID or PadChest, and differed by 0.002 on CT-RATE reports. On BraTS, Clef correctly identified 90 of 100 FLAIR volumes while Qwen never chose it. d1 ranked lower than Clef on six of seven tasks. No model performed well on motion severity. Clef was faster per request than Qwen on tasks with many questions per input. d1 used 3 to 9 times less energy per request than Clef. Conclusions: System 1 models can perform important tasks in radiology with high accuracy, at lower compute cost than LLMs used in the usual way. When an LLM is constrained to a single answer token, its cost and performance is similar to System 1 models unless multiple questions are asked. A 3B System 1 model was close to the 27B models on report text but not on images. No model performed well on motion severity.

0.25

EVADE: Evidence-Verified Agentic Diagnosis with Escape

cs.CV ·2026-08-19 ·Mohaimenul Azam Khan Raiaan, Nur Mohammad Fahad
similarity 0.61
Abstract

Medical vision-language models (VLMs) can achieve high accuracy but remain unreliable: they are systematically overconfident, benefit little from test-time reasoning, and lack the ability to reliably calibrate trust in their own responses. We introduce EVADE (Evidence-Verified Agentic Diagnosis with Escape), an inferential, non-training method that enhances the safety of deploying a single frozen VLM. EVADE responds and, when uncertain, localises the region most diagnostically relevant, re-answers on a zoomed view, and commits only when both the entire image and the zoomed view responses agree; otherwise, it abstains. To directly address verification hallucination in single-model self-checking, our main idea is to verify gate consistency across different image views rather than re-reading the model's own text. Experimental evaluation on VQA-RAD, SLAKE, and PathVQA using Qwen2.5-VL-7B reports that EVADE is the only method that simultaneously improves both calibration and selective risk while maintaining accuracy, reducing expected calibration error (ECE) by up to 45% compared to zero-shot. Chain-of-thought, self-consistency, and self-verification all fail at least one axis. A grounding analysis reports that self-proposed regions perform better at diagnostic structure localisation than centres or random crops. However, a 7B VLM cannot use this localisation to revise answers. Therefore, reliability gains come from the consistency gate and calibrated abstention.

0.23

Grounding Radiology Reports in 3D Chest CT: Results of the ReXGrounding Challenge

cs.CV cs.AI ·2026-11-18 ·Mohammed Baharoon, Mahmoud Hussain Alabbad, Sung Eun Kim, Xiaoman Zhang, Lucas Bijnens +57 more
benchmark similarity 0.60
Abstract · 25 pages, 13 figures, 4 tables

Segmenting each reported finding in a radiology scan would allow findings to be measured and tracked over time and let AI systems generate reports that are verifiable, but so far AI models have performed poorly at this task. To advance this task, we organized the ReXGrounding Challenge at MICCAI 2026, the first challenge dedicated to it. Given a non-contrast chest CT scan and the set of findings from its report, participants trained models to produce the corresponding set of 3D segmentations. The challenge used 2,992 training and 200 validation scans from the ReXGroundingCT dataset, and evaluated methods on a held-out test set of 300 scans with 582 findings, exhaustively annotated by board-certified radiologists. In total, 48 teams from 15 countries made 760 submissions, and the best method reached a Dice of 0.375 and a hit rate of 0.77, matching agreement between two independent radiologist groups (Dice 0.32, hit rate 0.76, on a 50-scan subset). On the 100 scans of the pre-challenge benchmark, the winner reached a Dice of 0.390, against 0.285 for VoxTell, the best model before the challenge, which five of the six best teams fine-tuned. Non-focal findings remained far harder to segment than focal ones, instance F1 stayed below inter-reader agreement (0.34 vs. 0.47), and models sometimes segmented the right abnormality in the wrong location. Top methods thus match radiologist agreement in Dice, but non-focal findings, findings with multiple instances, and adherence to the anatomical location described in the text remain open problems.

0.29

Aggregate Accuracy Hides Diagnosis-Specific Failure in Medical Vision-Language Models

eess.IV cs.CLcs.CVcs.LG ·2026-11-11 ·Shreya Ajay Kale, Angad Ripudaman Singh Bajwa
published similarity 0.60
Abstract · Accepted at the NeurIPS 2026 Workshop on Medical Reasoning with Vision Language Foundation Models (Med-Reasoner). 16 pages including NeurIPS…

Medical vision-language models (VLMs) are compared mainly by accuracy averaged across findings, a summary that can hide complete failure on a single diagnosis. We audit five open medical VLMs (MedGemma-4B, Lingshu-7B, HuatuoGPT-Vision-7B, Qwen2.5-VL-7B, and MedVLM-R1) on 6,048 ChestX-ray14 questions balanced by sex, age, finding, and label. On the 432 pneumothorax-positive X-rays, HuatuoGPT-Vision and Qwen2.5-VL detect zero cases while MedGemma and Lingshu detect 38% and 67% of the same images. The two failing models answer "no" to all 864 pneumothorax cases (balanced accuracy 0.500, chance), yet produce fluent, anatomically specific explanations that name the signs of a collapsed lung and then deny them, with no hedge or abstention. This failure is not an artifact of prompting, image resolution, label ambiguity, or model scale. It persists across four prompt formats, at native resolution, and on single-label cases. A within-model control shows the same forced prompt gives HuatuoGPT 79% recall on nodule but only 6% on pneumothorax. It survives a tenfold scale increase (Qwen2.5-VL-72B detects 4%) and replicates on SIIM-ACR, an independent dataset with radiologist-drawn masks, where the failing models detect 0 of 432 confirmed pneumothoraces, including 0 of the 144 largest lesions. Reading the models' logits and internal states shows this is not blindness. The two failing models are highly confident yet no better than chance and a linear probe recovers pneumothorax from their hidden representations even where recall is zero, so the finding is represented internally but suppressed at the output. Aggregate accuracy therefore cannot establish that a medical VLM can see a given finding, because a model that misses one can still describe it convincingly. Reporting per-finding recall and specificity on balanced cases is needed to tell the difference.

0.33

Multi-Agent AI System for Radiology Report Structuring and Quality Assurance with Independent Radiologist Evaluation

cs.CL ·2026-08-18 ·Iryna Hartsock, Cesar Lam, Christopher Otteni, Aliya Qayyum, Robert Gatenby +2 more
similarity 0.59
Abstract · 14 pages, 2 figures, 4 tables

Purpose: To develop and evaluate a locally deployed multi-agent AI system for radiology report structuring and quality assurance. Materials and Methods: This retrospective study included 638 radiology reports from CT examinations of the chest, abdomen, and pelvis dictated by 15 board-certified radiologists in 2023 and 2024. A multi-agent AI pipeline was developed to perform report structuring and quality assurance (QA). The system structured the report into standardized anatomical sections at the sentence level using regex rules and local large language models. It also detected mismatches between the Findings and Impression sections, or within sections; gender-anatomy conflicts; and undocumented communication of critical findings. Two board-certified radiologists independently evaluated a 45-report subset. Results: The multi-agent system structured the Findings sections of all reports (22,270 sentences) into a predefined anatomical format while retaining the original report content. The system flagged 90 (14.1%) reports, most commonly for section mismatches (80 reports, 12.5%). In the radiologist evaluation, both reviewers agreed that 31 (69%) were correctly restructured, 2 reports (4%) were incorrectly restructured, and disagreed on the remaining 12 reports (27%). Both reviewers agreed that no clinically important information was omitted and no fabricated content was introduced. Overall QA performance was rated as "excellent" or "good" in 84% of the evaluated reports, with the remaining reports rated as "fair". Conclusion: A locally deployed multi-agent AI system combined radiology report structuring and quality assurance within a single workflow. The system demonstrated favorable performance in radiologist evaluation. Such systems may support standardization of reporting and quality assurance in radiology practice.

0.37

Visual Harness Scales General VLMs to Medical Images

cs.CV ·2026-11-17 ·Shaowen Wan, Hanqi Jiang, Zihao Wu, Junhao Chen, Weihang You +4 more
similarity 0.59
Abstract

We show that an appropriate visual harness can substantially improve the performance of general vision-language models (VLMs) across diverse medical imaging tasks. We introduce VERA, a medical visual harness that equips general VLMs with interactive visual tools and systematic diagnostic evidence management. With VERA, general VLMs interactively explore medical images and progressively acquire diagnostic evidence, which is preserved in a lossless memory for subsequent retrieval and use. After submitting an initial answer, the VLM receives an assessment of potential omissions and the reliability of identified findings. This assessment guides further image inspection and measurement, followed by answer revision in an iterative agentic loop until sufficient evidence is obtained. Across 11 tasks and four imaging modalities, VERA improves performance on all tasks with Qwen3.8-27B, with notable gains in spleen measurement (63.3% to 98.3%), renal search (57.5% to 71.2%), and pulmonary nodule detection (0.0% to 28.2%). High-capability API-based VLMs achieve even higher performance with VERA. For example, GPT-6.1 Sol improves pulmonary nodule detection from 10.8% to 69.2% with VERA, demonstrating the complementary benefits of stronger model capabilities and an effective medical visual harness. Our results highlight the potential of visual harnesses as a new paradigm for scaling general VLMs to medical imaging tasks.

0.26

Beyond Benchmark Scores: Auditing Medical Vision-Language Models for Chest X-Ray Tuberculosis Screening

cs.CV cs.LG ·2026-09-18 ·Mushir Akhtar, M. Tanveer, Mohd. Arshad
benchmark similarity 0.59
Abstract · 27 pages, 7 figures, and 21 tables; includes extended methods, statistical analyses, and robustness evaluations

A medical model's benchmark score does not establish that the same conclusion holds under a different evaluation. This study tests whether claims about model ranking, score reliability and screening performance survive changes in cohort, prompt, negative spectrum, specified prevalence and operating threshold. We audit three medical vision-language models (BioMedCLIP, CheXficient, and MedSigLIP) and a general-domain OpenCLIP comparator on 12,200 chest radiograph records from four datasets (Montgomery, Shenzhen, TBX11K, and VinDr-CXR). Five fixed prompt families yield 244,000 model--image--prompt scores. No model leads every cohort and reliability criterion. Prompt-family changes alter AUROC in 21 of 48 multiplicity-controlled comparisons. Replacing healthy controls with sick non-tuberculosis controls reduces AUROC by 0.075--0.306 across all four models. On VinDr-CXR, the three medical models distinguish tuberculosis from no-finding controls substantially better than from pneumonia or lung tumor; their AUROC point estimates for both named diseases fall below 0.5. CheXficient has documented VinDr-CXR pretraining exposure, which limits the interpretation of its results. Thresholds chosen for 95\% sensitivity on TBX11K training retain that constraint by point estimate in only four of sixteen target evaluations. A five-seed supervised source model reaches 0.999 AUROC on TBX11K validation but 0.629 on each of two external cohorts. Conservative exclusion of perceptual-overlap candidates narrows this gap without closing it. These retrospective, single-task results show that discrimination, score reliability and threshold retention support different portability claims. Evidence for chest X-ray tuberculosis screening should identify the complete evaluation specification rather than attribute clinical portability to a checkpoint alone.

0.28

Answer or Defer? Testing VLMs' Stated Confidence on Brain MRI

cs.CV cs.AIcs.LG ·2026-11-09 ·Amir Sabbaghziarani, Parsa Ghazvinian, Sepehr Salem, Sergey Plis
publishedcode/data similarity 0.58
Abstract · Accepted to the WACV 2027 FABRIC Workshop

Vision-language models (VLMs) could support medical-image interpretation, but their use requires deciding which interpretations to accept and which images to refer to a clinician. We test whether thresholding stated confidence can retain useful coverage while limiting errors among accepted answers, and how this depends on the population. Eight open-weight VLMs, including two reasoning models, assess 3,888 brain MRI slices from post-treatment glioma patients (BraTS 2024) and healthy volunteers (IXI) for tumor or gross abnormality. BraTS labels are mask-derived; IXI slices are treated as negatives. On BraTS, no threshold selects a nonempty set with at most 5% empirical error for any model, even when chosen retrospectively. This also holds for four models evaluated on a large-lesion, distant-negative subset. At a 10% error budget, Gemma-4-12B retains 24.4% of slices and every other model at most 2.5%. To investigate this limited selection ability, we separate confidence differences between predicted answers from differences within each answer. For four models with available outcome-level summaries, pooled mean confidence differs more between answers than between correct and incorrect responses within each answer. A covariance decomposition explains how this pattern can produce opposite confidence-correctness associations across populations. At a 20% error budget, accepting every "tumor" answer covers more slices than any confidence threshold for two models. These findings caution against using unvalidated stated confidence as a standalone deferral signal and support population-specific validation before deployment. Code is available at https://github.com/amir-sbg/VLM-Answer-or-Defer.

0.45