CS Paper Radar

Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction

Mojtaba Safari, Shansong Wang, Zach Eidex, Matthew Goette, Tonghe Wang, Zhen Tian, Xiaofeng Yang

cs.CV physics.med-ph ·submitted 2026-08-10 19:37 UTC · v1
top venue

Abstract

Patient motion remains a source of image degradation in brain MRI, leading to signal loss, blurring, and geometric distortion that compromise quantitative analysis. Existing deep learning methods for motion correction typically rely on paired clean-corrupted data or k-space acquisitions, which are rarely available in clinical settings. We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction that requires neither paired training data nor explicit motion labels. SSRL-MAR employed a three-stage training strategy: (1) contrastive learning on 3D patches to extract motion representations by contrasting clean and synthetically corrupted images, (2) a motion artifact-aware synthesis network to generate motion artifacts from clean scans, and (3) a motion artifact-aware generator to restore clean volumes using the learned degrader for self-supervised supervision. On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%. On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity. Against a source-only supervised model trained on the same simulated pairs, SSRL-MAR improved PSNR by up to 2.0 dB on MR-ART after unsupervised domain adaptation, and remained within 0.25-0.47 dB of an oracle supervised model that requires real paired data unavailable in practice. At the milder motion level, volumetric error in structures such as the corpus callosum and ventricular system decreased by more than 50%, confirming improved neuroanatomical consistency. These results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.

DOI
10.1109/TMI.2026.3724112

Closest papers

Nearest neighbours by meaning across the whole index.

Training-Free Motion-Corrected 3D Brain MRI Reconstruction via Event-Guided References

cs.CV ·2026-11-01 ·Wei Jiang, Hongli Chen, Tianyi Ding, Feng Liu, Nan Ye +1 more
code/data similarity 0.71
Abstract

Head motion causes artefacts in 3D brain MRI and can bias structural measurements. Model-based correction alternates between image and motion estimation, but artefacts in the reconstructed reference can reinforce motion errors. Learned priors can reduce these artefacts but require pretraining and may add test-time computation. We propose EventMC (event-guided motion correction), a training-free method for interleaved Cartesian acquisitions. It iteratively detects motion events and estimates motion using reference images reconstructed from stable intervals. It then refines the image and motion from low to high spatial frequencies. In a fair comparison in simulation (same reconstruction), EventMC's motion estimates improve mean PSNR by up to 4.0 dB over those of the learning-based MotionTTT. A single run of EventMC is up to 7.5 times faster than MotionTTT with less than half the GPU memory. On in vivo motion-corrupted scans, EventMC achieves similar mean image quality to MotionTTT without any training. Code is available at https://github.com/bayesbreeze/EventMC.

0.36

Beyond Representation Learning: A Systematic Study of Joint-Embedding Predictive Generation for 3D Brain MRI

cs.CV ·2026-08-28 ·Meng Zhou, Wenhao You, Yuxing Chen, Yueying Tian
similarity 0.68
Abstract · Preprint, code will be released after review

Joint-embedding predictive architectures (JEPAs) have primarily been developed for self-supervised representation learning. Denoising JEPA (D-JEPA) recently demonstrated strong generative capabilities on natural images, yet the applicability to 3D medical imaging remains unexplored. Building on the D-JEPA framework, we present Med-D-JEPA, a systematic adaptation and evaluation of joint-embedding predictive generation for 3D brain MRI. Med-D-JEPA operates on continuous latent tokens produced by a 3D KL-regularized adversarial variational autoencoder, and combines masked context prediction, representation-level alignment, per-token diffusion, and iterative next-set-of-token sampling. We evaluate unconditional and class-conditional generation quality on BraTS2019 and OASIS-1 datasets; downstream classification utility; and preliminary whole-tumor segmentation on BraTS2020. Across different generation settings, Med-D-JEPA achieves superior or competitive performance compared to several strong baselines on fidelity and diversity metrics. Compared to training with real samples, Med-D-JEPA-based synthetic pretraining improves classification AUC from 0.63 to 0.85 on BraTS2019 and from 0.78 to 0.87 on OASIS-1. In the segmentation study, pretraining on Med-D-JEPA samples improves Dice from 0.74 to 0.80 and reduces HD95 from 13.40 to 9.56 mm. These findings establish joint-embedding predictive generation as a promising direction for 3D medical image synthesis and encourage further research in this direction.

0.47

MRI Super-Resolution with RCDM/WaveMix and Task-Aware Segmentation

cs.CV ·2026-09-30 ·Kavitha Viswanathan, Harsh Choudhary, Amit Sethi
similarity 0.68
Abstract

Super-resolution and quality enhancement of 1.5\,T brain MRI are normally validated with image-fidelity metrics, although their purpose is to improve downstream analysis. We study whether enhancement improves tissue segmentation, and for which segmenters. We propose an unpaired, physics-guided training pipeline for a lightweight ($\le$2.5\,M parameter) recurrent convolutional enhancer: a six-module stochastic 1.5\,T degradation operator, a residual adversarial network that adds scanner-specific texture without moving anatomy, and a cycle-consistent objective with an anti-identity penalty that rules out the copy solution. We then train U-Net, Swin-UNet and wavelet token-mixing segmenters \citep{jeevan2023wavemix} from scratch on either raw or enhanced 1.5\,T images of the same subjects, using identical labels and subject-level splits, for three enhancer variants and two datasets. On ABIDE (41 held-out subjects, FreeSurfer labels) enhancement significantly improves the wavelet segmenter (mean Dice $+0.014$, Wilcoxon $p=3.5\times10^{-5}$; CSF $+0.018$, grey matter $+0.013$), significantly degrades the U-Net ($-0.008$, $p=5.1\times10^{-4}$) and leaves Swin-UNet unchanged. On IXI, whose labels come from FSL-FAST, enhancement lowers Dice for all nine pairings, almost entirely through CSF; we trace this to spatially implausible CSF voxels in the labels that penalise smoother predictions. Enhancement of low-field MRI should therefore be validated per downstream model and against reliable labels.

0.14

FlowMoDL: Model-Based Deep Learning with Conjugate-Gradient Data Consistency for Highly Accelerated 4D Flow MRI Reconstruction

cs.CV cs.LG ·2026-08-26 ·Tristan Gottwald, Michelle Bruch, Mubashir-Ul Hassan, Fatma Alickovic, Milan Kloiber +4 more
similarity 0.68
Abstract

We present FlowMoDL, an unrolled neural network for highly accelerated 4D flow MRI reconstruction that directly optimizes for both anatomical magnitude and phase-derived velocity accuracy. Building on the MoDL framework, FlowMoDL alternates a learned (3+1)D spatiotemporal denoiser with conjugate-gradient data-consistency updates based on the SENSE forward model. A novel dual-pathway conditioning scheme adapts the denoiser features and data-consistency weighting, enabling a single model to handle varying acceleration factors ($10\times$ to $50\times$). To ensure physiological accuracy, the network is trained using a deep-supervision composite loss that explicitly penalizes velocity magnitude and angular errors, stabilized by a curriculum schedule. We evaluate FlowMoDL on the multi-center CMRx4DFlow dataset against classical and deep-learning baselines (CG-SENSE, MoDL, FlowVN, and FlowMRI-Net). A key advantage of FlowMoDL is its superior gradient step efficiency. When evaluated under an equivalent, limited budget of gradient steps, competing flow-specific networks degrade significantly. In contrast, FlowMoDL robustly converges and strictly outperforms all competitors across all acceleration factors in magnitude SSIM, nRMSE, relative velocity error, and angular error, successfully recovering sharp structural details and temporally coherent velocity fields.

0.09

Systematic Morphometric Brain Autoencoding for Representation Learning in Neurodegenerative Diseases

cs.CV cs.LG ·2026-10-27 ·Nuria Balbás-Esteban, Albert Belenguer-Llorens, Elaheh Moradi, Jussi Tohka, Vanessa Gómez-Verdejo +1 more
similarity 0.66
Abstract

Early identification of neurodegenerative disorders using structural T1-weighted MRI is essential for timely clinical intervention, yet supervised deep learning models often struggle to generalize due to limited annotations and scanner-induced distribution shift. Self-supervised learning offers a promising alternative; however, existing approaches are largely adapted from natural image paradigms, relying on contrastive objectives or generic masked reconstruction with voxel-wise losses, which may not fully capture the distributed morphometric patterns associated with neurodegeneration. We introduce SYMBA (SYstematic Morphometric Brain Autoencoding), a self-supervised pretraining framework specifically designed for structural brain MRI. SYMBA integrates anatomically constrained masking, a multi-scale structural similarity (MS-SSIM) reconstruction objective, and a progressive curriculum that transitions from local anatomical detail to global brain morphology. These components explicitly incorporate neuroanatomical structure into the self-supervised objective rather than relying on generic image priors. Pretrained on 6,953 T1-weighted MRI scans from nine heterogeneous cohorts, SYMBA is evaluated using frozen linear probing on two independent unseen datasets, enabling a strict assessment of out-of-distribution generalization. Across multiple clinical tasks, SYMBA consistently outperforms recent neuroimaging foundation models, achieving 0.930 AUROC for Alzheimer's disease classification, 0.772 for mild cognitive impairment conversion prediction, and strong performance in amyloid status prediction. In low-label regimes, SYMBA demonstrates high sample efficiency, reaching approximately 0.90 AUROC for AD/CN classification using only six labeled subjects.

0.18

Conditional Flow Matching for Cross-Field MRI Harmonisation

cs.CV ·2026-09-01 ·Baris Imre, Aram Salehi, Levente Baljer, Andrew Webb, Marius Staring +1 more
similarity 0.65
Abstract · 10 pages, 2 figures

Magnetic resonance images of the same subject look markedly different across field strengths, which complicates the comparison and pooling of data across sites. We address cross-field brain-MRI translation for the MRIxFields2026 challenge, and in particular its Task~3: a single model that translates between any directed pair of the five field strengths and across three contrasts. We phrase the problem as a conditional flow matching path: because the source and target volumes are spatially registered, we learn a velocity field that carries the source slice directly to the target slice, rather than starting from noise. To learn this mapping from only three paired subjects, the unified model is trained in three stages: a degradation-bridge pretraining that distills a restoration prior from the abundant unpaired retrospective cohort, a cross-field finetuning over all directed pairs on the paired cohort, and an adversarial refinement that sharpens the output. At inference, we integrate the learned velocity with a second-order Heun solver in a handful of steps. A restoration prior learned without any paired data already reaches a mean SSIM of 0.837, and each subsequent training stage improves on it. A single 6.3M-parameter model thereby covers all 60 field-pair and contrast combinations, with inference in five solver steps per slice. On the challenge evaluation set the model reaches a mean SSIM of 0.909, averaged over the three contrasts, outperforming regression and diffusion baselines built on the identical network on all three challenge metrics.

0.22

Representation Learning for 3D Brain Imaging: A Benchmark

cs.CV ·2026-11-04 ·Pierre Falconnier, Robin Trombetta, Nicolas Duchateau, Carole Lartizien
top venuebenchmarkcode/data similarity 0.65
Abstract

Many deep learning architectures for computer vision tasks rely on features extracted by a pre-trained encoder on large databases of natural 2D RGB images. However, the wide domain gap with medical images hampers the direct transfer of optimized deep learning models from computer vision to clinical applications. Recently, self-supervised pre-training and foundation models emerged as promising alternatives to mitigate these limitations. Yet, constructing such models for medical imaging faces critical challenges, including designing and adapting training strategies for large 3D volume datasets, and the need for standardized benchmarks to evaluate feature extraction performance. In this study, we propose an extensive comparison of vision encoders with a focus on 3D brain MRI. First, we consider 8 fully and self-supervised models pretrained on natural images (e.g. ResNet, DINO, CLIP) and 10 backbone architectures trained on medical images, either based on supervised (e.g. RadImageNet) or self-supervised (e.g. BiomedCLIP, SimCLR) tasks. All pre-trained encoders are evaluated on various downstream tasks to assess the representation power of their latent representations, including age and sex prediction as well as disease classification on the ADNI and PPMI datasets. Our study shows that 2D encoders pre-trained on natural images perform the most favorably, even compared to models pre-trained on more than 100k brain MRI volumes, highlighting the need for more suitable and robust methods for representation learning in 3D medical imaging. The source code for this study is publicly available at: https: //github.com/PierreFalconnier/brain-representation-benchmark.

0.50

Pathology Randomization for Synthetic Priors and Zero-Shot Detection

cs.CV cs.AIeess.IV ·2026-11-16 ·Alexandra G. Roberts, Tonmoy Hossain, Mark Olchanyi, Stefan Brandstätter, Jonathan Williams Ramirez +5 more
benchmarkcode/data similarity 0.64
Abstract · 25 pages, 9 figures, 13 tables (8-page main text with appendices). Code: https://github.com/agr78/Pathology-Randomizer

Hospital brain imaging archives hold a diverse array of pathology at sample sizes beyond prospective studies, particularly for underrepresented populations and diseases. To unlock uncurated clinical data and scale analysis, methods are needed to detect abnormalities across contrasts and resolutions. Synthetic data has provided robust, contrast-agnostic models for a variety of human neuroimaging tasks in healthy anatomy, but pathology detection and other tasks in clinical settings still require real patient data, contrast-specific models, or disease-specific generators. We propose PathoDraw, a generative model of brain MRI with pathology. A conditional distribution of lesions given the healthy anatomy is drawn into the label map before contrast-agnostic rendering, and a single network estimates healthy anatomy with exact signed intensity deviation of any input scan. The contrast-agnostic 3D UNet learns the healthy labels under the lesion and the signed deviation directly and identifies pathology via robust tissue statistics and learned features, despite no training on real pathology. We show zero-shot detection on public stroke, tumor, and white matter hyperintensity datasets as well as archived clinical data, spanning $T_1$w, FLAIR and $T_2$w at various resolutions under a recent unsupervised anomaly detection benchmark protocol. Our single model exceeds or performs comparably to contrast-specific anomaly detectors trained on real scans and keeps healthy anatomy intact. The same generator trains networks for super-resolution and for registration in the presence of pathology. Our model, robust across acquisition and disease, enables the use of uncurated, archived data for clinical analysis. Our code is available at https://github.com/agr78/Pathology-Randomizer.

0.47