CS Paper Radar

Training-Free Motion-Corrected 3D Brain MRI Reconstruction via Event-Guided References

Wei Jiang, Hongli Chen, Tianyi Ding, Feng Liu, Nan Ye, Hongfu Sun

cs.CV ·submitted 2026-11-01 13:45 UTC · v1
code/data

Abstract

Head motion causes artefacts in 3D brain MRI and can bias structural measurements. Model-based correction alternates between image and motion estimation, but artefacts in the reconstructed reference can reinforce motion errors. Learned priors can reduce these artefacts but require pretraining and may add test-time computation. We propose EventMC (event-guided motion correction), a training-free method for interleaved Cartesian acquisitions. It iteratively detects motion events and estimates motion using reference images reconstructed from stable intervals. It then refines the image and motion from low to high spatial frequencies. In a fair comparison in simulation (same reconstruction), EventMC's motion estimates improve mean PSNR by up to 4.0 dB over those of the learning-based MotionTTT. A single run of EventMC is up to 7.5 times faster than MotionTTT with less than half the GPU memory. On in vivo motion-corrupted scans, EventMC achieves similar mean image quality to MotionTTT without any training. Code is available at https://github.com/bayesbreeze/EventMC.

Closest papers

Nearest neighbours by meaning across the whole index.

Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction

cs.CV physics.med-ph ·2026-08-10 ·Mojtaba Safari, Shansong Wang, Zach Eidex, Matthew Goette, Tonghe Wang +2 more
top venue similarity 0.71
Abstract

Patient motion remains a source of image degradation in brain MRI, leading to signal loss, blurring, and geometric distortion that compromise quantitative analysis. Existing deep learning methods for motion correction typically rely on paired clean-corrupted data or k-space acquisitions, which are rarely available in clinical settings. We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction that requires neither paired training data nor explicit motion labels. SSRL-MAR employed a three-stage training strategy: (1) contrastive learning on 3D patches to extract motion representations by contrasting clean and synthetically corrupted images, (2) a motion artifact-aware synthesis network to generate motion artifacts from clean scans, and (3) a motion artifact-aware generator to restore clean volumes using the learned degrader for self-supervised supervision. On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%. On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity. Against a source-only supervised model trained on the same simulated pairs, SSRL-MAR improved PSNR by up to 2.0 dB on MR-ART after unsupervised domain adaptation, and remained within 0.25-0.47 dB of an oracle supervised model that requires real paired data unavailable in practice. At the milder motion level, volumetric error in structures such as the corpus callosum and ventricular system decreased by more than 50%, confirming improved neuroanatomical consistency. These results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.

0.29

Unified Motion Correction and Reconstruction for Accelerated Zero Echo Time MRI

eess.IV ·2026-11-03 ·Yan Chen, Curtis A. Corum, James H. Holmes, Mathews Jacob
similarity 0.65
Abstract

Zero echo time (ZTE) MRI is near-silent, but dead time gaps, head motion, and undersampling jointly degrade reconstruction. To develop an accelerated ZTE MRI reconstruction framework that jointly estimates the 3D image and rigid-motion parameters, this work introduces Energy-based Motion Correction (EnMoCo), a regularized maximum a posteriori (MAP) formulation that also compensates for missing k-space center data and angular undersampling artifacts. Solved by alternating between k-space rigid-motion updates and conjugate-gradient data-consistency updates, the framework incorporates regularization via a pre-trained Multi-Scale Energy-based model (MuSE) implemented in a data-efficient 2.5D form. Evaluations on simulated and in vivo 3D ZTE data, spanning dead time gaps of 1.5 to 5 samples, rotations up to 17 degrees and translations up to 10 mm, demonstrate that EnMoCo significantly improves PSNR and SSIM relative to CG-SENSE and Autofocusing baselines (achieving roughly 10 to 15 dB higher PSNR for gaps >= 3.5) while reducing motion blur and tissue contrast inconsistencies.

0.24

Geometry-bridge flow matching for blind rigid-motion correction in head cone-beam CT

cs.CL physics.med-phcs.CV ·2026-11-18 ·Sungho Yun, Seungryong Cho
similarity 0.65
Abstract

Rigid motion of a patient head during head cone-beam CT (CBCT) scan can degrade image quality and complicate recovery of accurate anatomical structures from the measured projections. We present a 3D flow-matching prior approach that learns the image changes induced by motion. Its geometry-bridge connects motion-corrupted and motion-free Feldkamp-Davis-Kress (FDK) reconstructed images of the same source volume through progressively reduced simulated motion. The forward projector's geometry derivative supplies analytic velocity targets along this path. A plug-and-play loop encompasses the learned image updates together with spline-based pose estimation, conjugate-gradient data consistency, and image total-variation regularization. Both the refined image volume and the FDK reconstructed image volume at the estimated poses are evaluated. On simulated 360-view scans from 30 held-out CQ500 patients with nominal per-component motion amplitudes within 10 mm / 10 degrees, the framework achieved state-of-the-art image reconstruction quality and motion accuracy in comparison with other methos such as learned autofocus and diffusion-based joint reconstruction. Mean peak signal-to-noise ratio (PSNR) reached 37.1 dB and mean detector-plane reprojection error (RPE) was 0.27 mm. With matched endpoints at the inference settings, the geometry bridge improved PSNR by 1.6 dB and reduced RPE by 33% relative to image-linear training. With 50 prior updates and coarse-to-fine motion estimation, total processing time averaged 9.1 minutes per patient on an RTX A6000.

0.26

Scalable Unrolled Chains for MRI Reconstruction

cs.CV ·2026-10-24 ·Emiljo Mëhillaj, Ender Konukoglu
publishedcode/data similarity 0.63
Abstract · 23 pages (including supplementary material), 14 figures. Accepted at WACV 2027

Unrolled variational networks achieve state-of-the-art performance for accelerated MRI reconstruction, but standard end-to-end training becomes prohibitively memory intensive as the number and width of cascades increase. We propose a memory-efficient training framework that updates a randomly sampled cascade while retaining supervision from the final reconstruction loss. The error signal is propagated from the end of the chain to the sampled cascade using an activation-light backward pass that avoids storing full chain activations, thereby decoupling training memory from chain length. A time-conditioned network shared across cascades further keeps the parameter count independent of chain length. The backward pass is approximate only through frozen normalization statistics, and a trained exact gradient control shows the approximation leaves reconstruction quality unchanged. The framework remains trainable at chain lengths and cascade widths where standard end-to-end backpropagation exhausts GPU memory. On fastMRI single-coil knee and multi-coil brain reconstruction, our method consistently outperforms other local training approaches. On high-SNR knee slices, our method surpasses E2E-VarNet at $8\times$ and matches it at $4\times$, while on the complete brain validation set it surpasses E2E-VarNet at $8\times$ and achieves comparable performance at $4\times$, with fewer parameters, lower peak memory, and faster per-iteration training. Code is available at https://github.com/emehillaj/scalable-unrolled-mri.

0.50

FFAI: Flow Matching with Feedback Training and Adaptive Initialization for CT Reconstruction

cs.CV ·2026-10-29 ·Jigang Duan, Heran Wang, Genwei Ma, Xing Zhao
benchmark similarity 0.60
Abstract

Although low-dose, sparse-view, and limited-angle CT involve distinct degradation mechanisms, all three pose reconstruction challenges due to limited measurement information and can therefore be addressed within a unified framework. In iterative image restoration with flow matching, prediction errors may cause inference states to deviate from the prescribed training path, while a fixed initialization may be unsuitable for inputs with varying degradation severity. We propose a unified conditional flow matching method that conditions on the initial reconstruction and combines feedback-aware training with degradation-adaptive initialization. During training, a teacher network simulates inference updates to generate shifted states, from which a student network learns to recover high-quality reference images, improving its ability to handle prediction errors. During inference, the starting time is selected based on the noise level or extent of missing projection data, and the noise added to the initial state is adjusted accordingly to adapt the starting point to the input. Experiments on public benchmark datasets show that the proposed method achieves better quantitative results than the compared methods across all three reconstruction tasks, effectively suppressing noise and artifacts while preserving anatomical structures and details.

0.19

OpenMASC: An Open-Source Pipeline for Cross-Trajectory Metal-Aware Sampling and Correction in Accelerated MRI

cs.CV ·2026-09-26 ·Zhengyi Lu, Ming Lu, Chongyu Qu, Junchao Zhu, Junlin Guo +9 more
code/data similarity 0.60
Abstract

Metal implants corrupt MRI measurements throughout $k$-space, yet existing accelerated MRI methods assume clean data and most metal artifact reduction approaches assume fully sampled acquisitions. No public dataset provides paired $k$-space and images with and without metal for the same anatomy, and no framework jointly addresses artifact-aware acquisition and reconstruction across sampling trajectories. We present OpenMASC, an open-source pipeline covering the full workflow from data generation to deployment. A physics-based data generation module converts public CT volumes into paired clean and metal-corrupted MRI data in both Cartesian and radial formats. MA-VarNet, an unrolled reconstruction network with a per-cascade DC Rectifier, corrects artifacts that data-consistency steps reintroduce from corrupted measurements. A reinforcement learning agent actively selects $k$-space readouts and co-trains with the reconstruction network through a decoupled three-stage procedure. The framework is trajectory-agnostic except for the data-consistency operator, supporting both Cartesian and radial acquisition without architectural changes. Experiments on two datasets at $4\times$ and $8\times$ acceleration demonstrate consistent improvements over conventional and learned baselines on both trajectories.

0.31

CAST: Real-Time Motion Capture for Any Skeleton Topology

cs.CV ·2026-10-10 ·Pu Pang, Zhongfei Qing, Ling-Hao Chen, Songnan Li, Hua Huang +1 more
benchmarkcode/data similarity 0.60
Abstract · 39 pages. Code repository: https://github.com/fankewen/CAST

This paper studies the problem of recovering motion from monocular video, even when the target skeleton topology differs from the subject observed in the video. Although previous methods have made efforts to resolve this problem, they remain vulnerable to joint-rotation errors that are coupled across the skeleton and can propagate along its kinematic hierarchy. To mitigate these errors, we present CAST, a topology-aware motion capture framework that combines learned local rotations with geometric correction guided by predicted global bone directions. Our observability analysis characterizes which rotational components can be constrained by outgoing bone directions. Guided by this analysis, GRACE uses reliability-gated alignment to correct composed orientations in parent-to-child order, leaving unconstrained components to the learned rotation predictor. The motion predictor and correction module are trained jointly with motion-derived supervision, using a frozen image encoder. Experiments under the TopoCap evaluation protocol show that the proposed framework improves motion recovery across different target topologies, including unseen structures. Reference-based cross-skeleton evaluation on a curated Mixamo benchmark and a user preference study further assess transfer to different target structures. A causal CAST-B variant achieves over 51 FPS on a single NVIDIA A100 GPU, with timing covering image encoding and motion prediction. Code repository: https://github.com/fankewen/CAST.

0.51

RARF: Region-Aware Rectified Flows for 3D Brain MRI Inpainting

cs.CV cs.AIcs.LG ·2026-09-03 ·Tomas Guija-Valiente, Blanca Rodriguez-Gonzalez, Norberto Malpica, Angel Torrado-Carvajal
code/data similarity 0.59
Abstract · 11 pages, 2 figures. Preprint version corresponding to the initial submission prior to peer review, submitted as part of our participation i…

Medical image inpainting has the potential to improve automated brain MRI analysis by reconstructing healthy tissue within pathological regions. We introduce RARF, a task-agnostic region-aware rectified flow framework for masked data generation. We instantiate the framework for 3D brain MRI inpainting as our submission to the BraTS Inpainting Challenge 2026. RARF restricts the stochastic interpolation process to the inpainting region, while the observed voxels remain fixed and provide patient-specific anatomical context. A three-dimensional neural network receives the partially voided image, with Gaussian noise filling the missing region, together with the inpainting mask and the corresponding timestep. The model is trained using masked flow-matching and reconstruction-consistency objectives, combined with mask-aware preprocessing and data augmentation. During inference, the learned velocity field transports the initial noise toward a plausible reconstruction of the missing tissue, which is then combined with the unchanged observed anatomy. Experiments under the BraTS evaluation protocol show that the proposed approach produces competitive reconstructions while maintaining anatomical consistency. Source code is available at: https://github.com/TomasGuija/rarf.

0.41