Geometry-bridge flow matching for blind rigid-motion correction in head cone-beam CT

Sungho Yun, Seungryong Cho

cs.CL physics.med-phcs.CV ·submitted 2026-11-18 03:51 UTC · v1

Abstract

Rigid motion of a patient head during head cone-beam CT (CBCT) scan can degrade image quality and complicate recovery of accurate anatomical structures from the measured projections. We present a 3D flow-matching prior approach that learns the image changes induced by motion. Its geometry-bridge connects motion-corrupted and motion-free Feldkamp-Davis-Kress (FDK) reconstructed images of the same source volume through progressively reduced simulated motion. The forward projector's geometry derivative supplies analytic velocity targets along this path. A plug-and-play loop encompasses the learned image updates together with spline-based pose estimation, conjugate-gradient data consistency, and image total-variation regularization. Both the refined image volume and the FDK reconstructed image volume at the estimated poses are evaluated. On simulated 360-view scans from 30 held-out CQ500 patients with nominal per-component motion amplitudes within 10 mm / 10 degrees, the framework achieved state-of-the-art image reconstruction quality and motion accuracy in comparison with other methos such as learned autofocus and diffusion-based joint reconstruction. Mean peak signal-to-noise ratio (PSNR) reached 37.1 dB and mean detector-plane reprojection error (RPE) was 0.27 mm. With matched endpoints at the inference settings, the geometry bridge improved PSNR by 1.6 dB and reduced RPE by 33% relative to image-linear training. With 50 prior updates and coarse-to-fine motion estimation, total processing time averaged 9.1 minutes per patient on an RTX A6000.

Closest papers

Nearest neighbours by meaning across the whole index.

EUReCA: End-to-End Unified CBCT Reconstruction Across Clinical Acquisitions

eess.IV cs.AI ·2026-10-27 ·Jiening Zhu, Chengzhu Zhang, Jason Fan, LiCheng Kuo, Weixing Cai +6 more
similarity 0.69
Abstract

Cone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy, but reducing the number of projections to lower dose and scan time makes reconstruction increasingly ill-posed. We present EUReCA (End-to-end Unified REconstruction across Clinical Acquisitions), a geometry-aware feed-forward model for variable-view clinical linac CBCT. For a given acquisition trajectory, EUReCA accepts 8-100 projections with a single set of weights, without view-count-specific retraining; the same architecture and training recipe extend unchanged to other clinical trajectories. It combines learned projection features with an in-frame Feldkamp-Davis-Kress (FDK) reconstruction. The model encodes each projection with a shared multiscale backbone, back-projects features into multiresolution 3D grids using the acquisition geometry, aggregates variable numbers of views at fixed computational cost, and refines the volume with a global 3D transformer and multilevel decoder. On simulated data, EUReCA achieved 29.9-33.2 dB PSNR with 10-100 views and outperformed all applicable feed-forward baselines; it also exceeded iterative optimization-based methods while running orders of magnitude faster. On 15 measured patient CBCT scans evaluated against vendor reconstructions, EUReCA achieved the best performance at every tested view count. These results suggest that geometry-aware, measurement-anchored feed-forward reconstruction can provide a practical and flexible foundation for variable-view linac CBCT.

0.25

FFAI: Flow Matching with Feedback Training and Adaptive Initialization for CT Reconstruction

cs.CV ·2026-10-29 ·Jigang Duan, Heran Wang, Genwei Ma, Xing Zhao
benchmark similarity 0.69
Abstract

Although low-dose, sparse-view, and limited-angle CT involve distinct degradation mechanisms, all three pose reconstruction challenges due to limited measurement information and can therefore be addressed within a unified framework. In iterative image restoration with flow matching, prediction errors may cause inference states to deviate from the prescribed training path, while a fixed initialization may be unsuitable for inputs with varying degradation severity. We propose a unified conditional flow matching method that conditions on the initial reconstruction and combines feedback-aware training with degradation-adaptive initialization. During training, a teacher network simulates inference updates to generate shifted states, from which a student network learns to recover high-quality reference images, improving its ability to handle prediction errors. During inference, the starting time is selected based on the noise level or extent of missing projection data, and the noise added to the initial state is adjusted accordingly to adapt the starting point to the input. Experiments on public benchmark datasets show that the proposed method achieves better quantitative results than the compared methods across all three reconstruction tasks, effectively suppressing noise and artifacts while preserving anatomical structures and details.

0.19

RePrior: Measurement-Reconciled Prior Correction for Sparse-View CBCT Reconstruction

eess.IV cs.CV ·2026-10-08 ·Mengrui Yin, Tianxingjian Ding, Wufan Zhao, Ziyang Yan, Yu Tian
similarity 0.66
Abstract

Sparse-view cone-beam computed tomography (CBCT) is severely under-constrained by limited X-ray projections. Learned reconstruction can provide complementary anatomical information, but using it as a prior in patient-specific Gaussian reconstruction introduces two challenges. First, the discrepancy between the learned prior and current reconstruction is spatially non-uniform: some local differences contain useful missing 3D information, whereas others reflect prior bias. Second, even a volumetrically beneficial correction can conflict with the observed X-ray measurements. Since X-ray measurements are line integrals, spatially separated corrections may affect overlapping rays, with their signed projection responses reinforcing or partially canceling in the measurement residual, so their feasibility cannot always be assessed independently. In this paper, we introduce RePrior, a multi-stage progressive prior-correction framework that addresses correction actionability, measurement feasibility, and representation expressivity. Selective Correction Proposal (SCP) first identifies actionable signed local corrections from prior--reconstruction discrepancies. Measurement-Constrained Reconciliation (MCR) then jointly enforces their consistency with patient-specific X-ray measurements, while Hybrid Residual Enhancement (HRE) recovers additional correction capacity through complementary voxel- and Gaussian-domain degrees of freedom around the reconciled anchor. RePrior requires neither test-time ground truth nor case-specific network fine-tuning. RePrior gains approximately 2.6~dB in 3D PSNR over R$^2$-Gaussian across LUNA16, PANORAMA, and PENGWIN. Beyond prior-assisted reconstruction, it delivers additional gains in volumetric quality and observed-view projection fidelity, with consistent gains in held-out-view fidelity in the backbone-matched evaluation.

0.20

GeoPose: Patient-agnostic CTA-to-DSA registration through projection-space calibration

cs.CV ·2026-08-17 ·Rudolf L. M. van Herten, Robert Graf, Paula Feldman, Johannes C. Paetzold
similarity 0.65
Abstract

Aligning intraoperative biplanar digital subtraction angiography (DSA) to pre-procedural computed tomography angiography (CTA) requires rapid and accurate 3D-to-2D registration. Optimization-based methods are sensitive to initialization and may require hundreds of iterations, whereas learning-based approaches commonly rely on patient-specific training. We propose GeoPose, a population-trained framework that estimates the C-arm pose in a learned canonical frame and transfers it to the native frame of an unseen CTA through projection-space calibration and transform composition. A population-trained residual network refines the pose, followed optionally by low-budget image-driven optimization. GeoPose requires neither patient-specific adaptation nor explicit inter-volume preregistration. On 80 DSA observations from 20 held-out patients, optimization-free GeoPose achieved a carotid mean projected centerline distance (mPCD) of 5.8 mm and a clDice of 0.45, compared with 14.5 mm and 0.28 for the best-performing baseline, while requiring only 0.15 s. After 25 optimization iterations, GeoPose reached an mPCD of 4.6 mm and a clDice of 0.58 in approximately two seconds. Under the same budget, native-initialized optimization achieved 14.6 mm and 0.15, respectively. GeoPose thus provides rapid native-frame registration with fixed population-level weights and the geometric correspondence required for downstream biplanar 3D vascular reconstruction.

0.28

Training-Free Motion-Corrected 3D Brain MRI Reconstruction via Event-Guided References

cs.CV ·2026-11-01 ·Wei Jiang, Hongli Chen, Tianyi Ding, Feng Liu, Nan Ye +1 more
code/data similarity 0.65
Abstract

Head motion causes artefacts in 3D brain MRI and can bias structural measurements. Model-based correction alternates between image and motion estimation, but artefacts in the reconstructed reference can reinforce motion errors. Learned priors can reduce these artefacts but require pretraining and may add test-time computation. We propose EventMC (event-guided motion correction), a training-free method for interleaved Cartesian acquisitions. It iteratively detects motion events and estimates motion using reference images reconstructed from stable intervals. It then refines the image and motion from low to high spatial frequencies. In a fair comparison in simulation (same reconstruction), EventMC's motion estimates improve mean PSNR by up to 4.0 dB over those of the learning-based MotionTTT. A single run of EventMC is up to 7.5 times faster than MotionTTT with less than half the GPU memory. On in vivo motion-corrupted scans, EventMC achieves similar mean image quality to MotionTTT without any training. Code is available at https://github.com/bayesbreeze/EventMC.

0.36

EPC-RawDC: Equivariant Physics Constrained 3D Diffusion with Raw Data Consistency for CBCT to CT Image Synthesis

cs.CV cs.AIphysics.med-ph ·2026-10-29 ·Alzahra Altalib, Chunhui Li, Alessandro Perelli
code/datahot direction similarity 0.64
Abstract · 10 pages, 4 figures, 8 tables

Cone beam computed tomography (CBCT) is widely used for image guided and adaptive radiotherapy, but scatter, noise, reconstruction artifacts, and inaccurate Hounsfield units limit its quantitative use. Recent diffusion approaches for CBCT to CT synthesis remain largely image driven, with limited use of the underlying acquisition physics. We propose EPC-RawDC, a conditional 3D latent diffusion framework that combines volumetric generative modeling with two complementary constraints derived from the same scanner specific CBCT forward model. First, geometry equivariant projection constraint exploits the rotational equivariance of the CBCT forward operator by supervising the synthesized CT through correspondingly transformed reference projections. Second, raw data consistency uses noisy projection measurements of the individual acquisition as scan specific supervision during training. The framework was evaluated on two independent clinical cohorts with distinct scanner geometries and projection sources. For JUST, the physics constraints used measured clinical raw CBCT projections acquired with an Elekta system, whereas for SynthRAD2025 the projection data were simulated from the reference CT using a Varian geometry with Poisson photon statistics. EPC-RawDC achieved an SSIM of 0.97 in both cohorts and improved PSNR over DDPM by 2.66 dB on SynthRAD2025 and 2.10 dB on JUST, while reducing mean MAE by 20.3% and 19.0%, respectively. On SynthRAD2025, projection consistency and equivariant errors were reduced by 55.0% and 41.4% relative to DDPM. These results demonstrate that combining a volumetric diffusion prior with scanner geometry and scan specific projection measurements improves quantitative CBCT to CT synthesis across both simulated and measured projection domains. Code available after publication at https://github.com/ALZAHRAALTALIB/EPC-RawDC.

0.37

Beyond Control Points: Arcsecond Relative-Motion Estimation of Vision Measurement Platforms With Incomplete or Absent Control Fields

cs.CV ·2026-08-14 ·Meng Lian, Jian Wang, Shuixin Pan, Haibo Liu, Yueqiang Zhang +1 more
similarity 0.64
Abstract · 13 pages, 14 figures. Submitted to IEEE Transactions on Image Processing

Long-range vision-based deformation monitoring is highly sensitive to motion of the camera platform. Absolute-pose differencing typically relies on dedicated control data and propagates two independent pose errors into the relative-motion estimate. We develop a control-adaptive differential framework that estimates inter-frame platform motion directly from image displacements and known 3D points. With no dedicated control point, the framework recovers platform rotation from measurement-point observations. One surveyed control point enables prior-constrained translation recovery, while two nonparallel control rays recover full 3D translation. The framework requires neither nonlinear optimization nor an initial pose estimate. Excluding control data from the rotation stage makes the rotation estimate exactly immune to contamination confined to the control field. The inherited differential formulation also cancels translational extrinsic errors exactly. We derive the rotation observability condition, a leakage bound for unmodeled translation and nonrigid point motion, and the single-point axial-prior bias law. Under 0.5-pixel image noise, attitude changes of up to 30~arcmin, and 3D point perturbations of up to 2~mm, the multi-camera estimator achieves a rotation RMSE of 2.97~arcsec and an average runtime of 0.46~ms. With one surveyed control point, its prior-constrained translation RMSE is 1.19~mm. In a bridge experiment without a stable control field, the median coordinate-wise displacement RMSE relative to total-station measurements is 0.85~mm. The estimator also maintains zero divergence under the tested 3D coordinate perturbations on public RGB-D and stereo sequences. These results establish state-of-the-art accuracy, calibration robustness, and computational efficiency among the evaluated methods.

0.42

Surgical Kinematics from Monocular Video with Learned Articulated Motion Constraints

cs.CV cs.RO ·2026-09-23 ·Mehmet Kerem Turkcan, Soham Samal, Zoran Kostic
benchmark similarity 0.63
Abstract

Objective assessment of robotic surgery uses instrument kinematics, which must be reconstructed when only video is available. We introduce a kinematic reconstruction network for estimating instrument position, orientation and jaw angle from monocular video. Our visual representation combines global attention pooling of frozen DINOv3 features with local pooling at instrument landmarks from fine-tuned SAM 3.1 masks. Our shared Transformer encoder and temporal convolutional heads integrate this representation with mask geometry, monocular depth and visual state estimates from arm-specific multilayer regression networks. Our position branch predicts displacement magnitude and direction separately to preserve traveled distance. We fit trajectories to predicted state observations and motion increments by differentiable weighted least squares, expressing quaternion observations relative to cumulative predicted rotations to obtain a quadratic orientation objective. We evaluate reconstruction across 2,802 Open-H episodes. Compared with LiveMAE on the main Open-H benchmark, our method reduces path-length mean absolute error from 0.45 to 0.34\,cm and increases temporal mean average precision for motion segmentation from 44.54\% to 54.44\%.

0.20