OpenMASC: An Open-Source Pipeline for Cross-Trajectory Metal-Aware Sampling and Correction in Accelerated MRI

Zhengyi Lu, Ming Lu, Chongyu Qu, Junchao Zhu, Junlin Guo, Marilyn Lionts, Yanfan Zhu, Yuechen Yang, Tianyuan Yao, Jayasai Rajagopal, Bennett Allan Landman, Xiao Wang, Xinqiang Yan, Yuankai Huo

cs.CV ·submitted 2026-09-26 08:04 UTC · v1
code/data

Abstract

Metal implants corrupt MRI measurements throughout $k$-space, yet existing accelerated MRI methods assume clean data and most metal artifact reduction approaches assume fully sampled acquisitions. No public dataset provides paired $k$-space and images with and without metal for the same anatomy, and no framework jointly addresses artifact-aware acquisition and reconstruction across sampling trajectories. We present OpenMASC, an open-source pipeline covering the full workflow from data generation to deployment. A physics-based data generation module converts public CT volumes into paired clean and metal-corrupted MRI data in both Cartesian and radial formats. MA-VarNet, an unrolled reconstruction network with a per-cascade DC Rectifier, corrects artifacts that data-consistency steps reintroduce from corrupted measurements. A reinforcement learning agent actively selects $k$-space readouts and co-trains with the reconstruction network through a decoupled three-stage procedure. The framework is trajectory-agnostic except for the data-consistency operator, supporting both Cartesian and radial acquisition without architectural changes. Experiments on two datasets at $4\times$ and $8\times$ acceleration demonstrate consistent improvements over conventional and learned baselines on both trajectories.

Closest papers

Nearest neighbours by meaning across the whole index.

Learning Where and How Much to Sample: Volume-Adaptive k-Space Acquisition for Accelerated MRI

cs.CV ·2026-11-18 ·Reyhaneh Neshatavar, Mohsen Yavartanoo, Kyoung Mu Lee
similarity 0.69
Abstract

Magnetic resonance imaging (MRI) is an essential medical imaging technique, but its high costs and long acquisition times can limit accessibility. Accelerated MRI reduces acquisition time through k-space undersampling, yet conventional methods often rely on predefined sampling patterns and uniform slice budgets, overlooking anatomical variations and inter-slice relationships. In this paper, we propose a volume-adaptive k-space acquisition framework that jointly learns where and how much to sample across an entire MRI volume. Using only acquired auto-calibration signal (ACS) measurements, our method exploits volume-wide anatomical information to adaptively allocate sampling budgets across slices while identifying informative k-space lines. A learned joint slice--frequency refinement module coordinates sampling decisions while preserving an exact total volume-level acquisition budget. To reconstruct the acquired measurements, we design a sensitivity-aware synchronous cross-slice reconstruction network that estimates coil sensitivities from ACS measurements and progressively refines neighboring-slice reconstructions while enforcing hard k-space data consistency. Both networks are jointly optimized using reconstruction-based supervision without requiring fully sampled k-space at inference. Experiments on knee and brain MRI across multiple contrasts and acceleration factors demonstrate the adaptive behavior of our acquisition framework and evaluate its reconstruction performance.

0.23

VoxelSynth3D: Interpretable Volumetric Image-Domain Metal Artifact Reduction with a Paired Synthetic CLINIC Benchmark

cs.CV ·2026-10-01 ·Amritesh Banerjee, Abdul Basit, Renil Renji Joseph, Nouhaila Innan, Muhammad Shafique
publishedbenchmark similarity 0.68
Abstract · 7 pages, 7 figures. Accepted for publication at BHI 2026

Metal artifacts in postoperative musculoskeletal CT obscure bone-implant and adjacent soft-tissue interfaces. Many metal artifact reduction (MAR) methods require unavailable raw projections or learned models that may shift across scanners and implants. We present VoxelSynth3D, a training-free 3D image-domain framework for reconstructed CT. The framework combines support masking, normalized tissue synthesis, deviation gating, and restricted edge refinement. Detected implant voxels are preserved in the output, while correction targets metal-induced artifacts in the surrounding tissue. We also construct Synthetic CLINIC-Metal, a controlled paired synthetic evaluation resource, from no-metal CTPelvic1K volumes with clean targets, metal/artifact masks, fixed seeds, and patient-level splits; 75 unpaired real metal cases receive qualitative/no-reference evaluation only. The operating point was fixed in a near-flat validation basin. With exact-mask oracle localization, all methods share a metal-excluded tissue ROI. On 40 held-out cases, VoxelSynth3D reduced RMSE from 801.48 to 786.18 HU (paired gain 15.30 HU, 95% CI 11.68-19.23), improving every case and exceeding the evaluated 3D Gaussian smoother by 13.58 HU. Clean-edge agreement decreased next to metal but exceeded input beyond 5 mm. Thus, VoxelSynth3D provides case-consistent within-distribution tissue-error reduction with a localized structural tradeoff. Spacing-aware sensitivity retained aggregate broad-region improvement and identified near-metal calibration as a target.

0.28

Stochastic Finite-Transition Learning and Exploration for Accelerated MRI Reconstruction

eess.IV cs.CVeess.SP ·2026-10-09 ·Muhammad Usama Mirza, Esin Öztürk Işık, Tolga Çukur
similarity 0.66
Abstract

Generative MRI reconstruction maps an initial source distribution to the target image distribution along a learned recovery trajectory. Common generative methods, such as diffusion and flow, typically learn fine-grained local dynamics whose integration defines this global mapping, hence requiring many network evaluations at inference. Existing few-step sampling approaches can lower computational burden by approximating large transformations from local dynamics, albeit at the expense of reconstruction fidelity. FLEX-MRI instead partitions recovery into a small number of finite intervals between retained states defined by progressive changes in k-space support, and directly learns the reconstruction change across each interval. Because such finite transitions can admit multiple plausible outcomes, FLEX-MRI combines support-relaxed finite-transition learning with stochastic exploration. During training, randomized k-space sampling masks define finite-transition targets with varying support, while the prediction loss remains unrestricted by each individual mask. At inference, FLEX-MRI perturbs a random subset of currently estimated k-space coefficients, allowing the learned predictor to stochastically explore alternative transition paths. Each predicted state is then reconciled with the acquired measurements through data consistency. We theoretically show that this stochastic exploration induces nonzero transition-level variation through the learned recovery map and data consistency without requiring an auxiliary generative sampler. Experiments on multi-coil MRI datasets show that FLEX-MRI outperforms competing methods while maintaining computational efficiency comparable to few-step baselines.

0.23

Physics-based simulation unlocks scaling laws for generalizable MRI reconstruction

eess.IV cs.CV ·2026-11-11 ·Hong Shang, Zijian Zhan, Sen Jia, Xiang Fan, Jintao Meng +8 more
similarity 0.66
Abstract

Deep-learning-based magnetic resonance imaging (MRI) reconstruction holds great promise for accelerating acquisitions, yet its clinical translation remains bottlenecked by poor generalizability across unseen scanners, populations, anatomies, and protocols. Gathering sufficiently diverse clinical datasets to overcome this bottleneck is hindered by high acquisition costs, privacy restrictions, and institutional biases. Here, we introduce Scalable Inverse Model (SIM), a framework that systematically co-designs physics-simulated training data, model architecture, and learning paradigms around scalability--leveraging compute scaling to overcome historical data bottlenecks and achieve robust zero-shot MRI reconstruction. Across 14 public and in-house datasets--spanning seven international centers, five vendors, field strengths of 0.3-7 T, over ten anatomical regions, more than ten acquisition protocols, downstream quantitative and molecular tasks, and a 150-scan blinded radiologist study--SIM demonstrates robust zero-shot generalizability, recovering fine anatomical details while suppressing aliasing artifacts where conventional deep-learning methods fail. Attention-map analyses confirm that SIM learns physically explainable, dynamically adaptive reconstruction primitives rather than anatomy-specific priors. SIM establishes a scalable, privacy-preserving, and democratized infrastructure for universal MRI reconstruction, providing a blueprint for generalizable AI across inverse problems in medical imaging.

0.22

Scalable Unrolled Chains for MRI Reconstruction

cs.CV ·2026-10-24 ·Emiljo Mëhillaj, Ender Konukoglu
publishedcode/data similarity 0.64
Abstract · 23 pages (including supplementary material), 14 figures. Accepted at WACV 2027

Unrolled variational networks achieve state-of-the-art performance for accelerated MRI reconstruction, but standard end-to-end training becomes prohibitively memory intensive as the number and width of cascades increase. We propose a memory-efficient training framework that updates a randomly sampled cascade while retaining supervision from the final reconstruction loss. The error signal is propagated from the end of the chain to the sampled cascade using an activation-light backward pass that avoids storing full chain activations, thereby decoupling training memory from chain length. A time-conditioned network shared across cascades further keeps the parameter count independent of chain length. The backward pass is approximate only through frozen normalization statistics, and a trained exact gradient control shows the approximation leaves reconstruction quality unchanged. The framework remains trainable at chain lengths and cascade widths where standard end-to-end backpropagation exhausts GPU memory. On fastMRI single-coil knee and multi-coil brain reconstruction, our method consistently outperforms other local training approaches. On high-SNR knee slices, our method surpasses E2E-VarNet at $8\times$ and matches it at $4\times$, while on the complete brain validation set it surpasses E2E-VarNet at $8\times$ and achieves comparable performance at $4\times$, with fewer parameters, lower peak memory, and faster per-iteration training. Code is available at https://github.com/emehillaj/scalable-unrolled-mri.

0.50

STAIRS: Staging the Inverse Problem via Admissible-Support Scheduling for Unrolled MRI Reconstruction

cs.CV ·2026-11-06 ·Xiangjian Hou, Chang Ni, Chao Qin, Zhiwei Tan, Xin Wang +4 more
similarity 0.62
Abstract

Accelerated magnetic resonance imaging (MRI) forms images from incomplete Fourier measurements, shifting acquisition burden to computational reconstruction. Deep unrolled networks interleave learned regularization and data consistency, yet typically estimate the full unmeasured spectrum at every cascade. We propose STAIRS (Staging the Inverse Problem via Admissible-Support Scheduling), which projects intermediate reconstructions onto nested Fourier supports that expand to the full spectrum and conditions each update on its support transition. Conditional increments of a regularized log-determinant score of training covariance define a normalized spectral coordinate, accounting for dependencies between newly and previously admitted frequencies. Dyadic targets allocate larger coordinate increments to earlier cascades and are mapped to fixed supports before training, enabling coarse-to-fine reconstruction with unchanged sampling masks and data consistency. On fastMRI and Stanford2D, STAIRS improves matched Transformer (HUMUSNet) and convolutional (NAFNet) backbones in single- and multi-coil reconstruction, including radiologist-annotated pathology regions. It also outperforms predictor-based progression with lower parameter overhead and inference latency. Stage-wise analysis shows repeated error correction by projection and lower intermediate reconstruction errors than the backbones alone throughout support expansion. Ablations favor dyadic allocation over uniform expansion for square and line-band supports and over manual front-loading for square windows. Support projection alone improves reconstruction, and transition conditioning strengthens the gain. Cross-dataset evaluation shows improvements for both backbones in both directions. Support allocation thus complements regularizer design in unrolled MRI reconstruction.

0.22

One Evaluation, Any Operating Point: Hypernetwork-Amortized MeanFlow for 3D MRI Reconstruction

cs.CV ·2026-09-15 ·Ruibo Wang
similarity 0.62
Abstract · 38 pages (9-page main text plus appendices)

Generative priors reconstruct accelerated 3D MRI well but pay heavily at deployment: tens of network evaluations per volume, and protocol-specific hyperparameter tuning. A third hidden cost is the scanner's fixed sampling pattern. We treat the whole operating point as an input. A 3D MeanFlow patch network (a one-step flow model) is fine-tuned end-to-end through a warm-started, five-iteration differentiable conjugate-gradient projection. A small hypernetwork maps the operating point (data-consistency weight, acceleration, and the Cartesian sampling pattern itself) to the network's per-channel modulation. Three findings follow. (i) Learning the acquisition is worth more than any other operating point: on clinical knee data, the learned mask gains up to +2.34 dB over the protocol's variable-density mask. This gain requires the solver: with a feed-forward reconstructor the same learned mask hurts at 4x (-1.7 dB), but with the data-consistency projection it adds +4.6 dB. (ii) One evaluation is highly effective: it beats a 20-step patch-diffusion prior by up to +3.1 dB on brain and +2.9 dB on knee. Three to five evaluations extend the front to +6 dB while using a quarter of the prior's network calls. (iii) Fully sampled targets are optional: trained self-supervised on a split of acquired samples, the reconstructor matches its supervised twin at 4x on real data. Finally, we report what failed and why: subject-adaptive acquisition from measured energy, combining self-supervision with learned acquisition, and amortising the data-consistency weight.

0.23

SliceBridge: Context-Consistent Repair of Corrupted Slice Intervals in T1-Weighted MRI

cs.CV ·2026-09-01 ·Jiheng Li, Michael E. Kim, Trent M. Schwartz, Gaurav Rudravaram, Derek B. Archer +4 more
similarity 0.62
Abstract

Structural magnetic resonance imaging (MRI) images are sometimes corrupted over a contiguous set of slices, where acquisition, motion, hardware, or reconstruction effects leave a single slice or short interval inconsistent with its neighbors while the rest of the image remains usable. Such localized corruption can bias downstream morphometric analysis, yet discarding or reacquiring an otherwise usable image is costly. We formulate this as an image restoration problem: given the location of the affected interval, reconstruct those slices from the surrounding anatomical and imaging context. We propose SliceBridge, a framework for restoring corrupted slice intervals in T1-weighted MRI using rectified flow matching conditioned on the surrounding intact slices and their relative slice positions. Through-plane consistency is encouraged by coupling the slices within the interval through interval-correlated initial noise, a shared flow time, and synchronized sampling. The restored interval is then inserted back, leaving all other slices unchanged. We trained and validated the model on 9,877 T1-weighted brain MRI volumes from four datasets and evaluated it on 581 external subjects using clean interval withholding and controlled corruptions. Compared with a matched model that reconstructed target slices independently, SliceBridge reduced error in slice-to-slice changes within repaired intervals by 32.9%-41.3% across interval lengths and achieved higher SSIM at every interval length. In controlled-corruption cases, SliceBridge reduced the median error in regional brain volume estimates produced by a downstream segmentation model from 1.95% in corrupted volumes to 1.05%.

0.31