CS Paper Radar

VoxelSynth3D: Interpretable Volumetric Image-Domain Metal Artifact Reduction with a Paired Synthetic CLINIC Benchmark

Amritesh Banerjee, Abdul Basit, Renil Renji Joseph, Nouhaila Innan, Muhammad Shafique

cs.CV ·submitted 2026-10-01 11:47 UTC · v2
publishedbenchmark

Abstract

Metal artifacts in postoperative musculoskeletal CT obscure bone-implant and adjacent soft-tissue interfaces. Many metal artifact reduction (MAR) methods require unavailable raw projections or learned models that may shift across scanners and implants. We present VoxelSynth3D, a training-free 3D image-domain framework for reconstructed CT. The framework combines support masking, normalized tissue synthesis, deviation gating, and restricted edge refinement. Detected implant voxels are preserved in the output, while correction targets metal-induced artifacts in the surrounding tissue. We also construct Synthetic CLINIC-Metal, a controlled paired synthetic evaluation resource, from no-metal CTPelvic1K volumes with clean targets, metal/artifact masks, fixed seeds, and patient-level splits; 75 unpaired real metal cases receive qualitative/no-reference evaluation only. The operating point was fixed in a near-flat validation basin. With exact-mask oracle localization, all methods share a metal-excluded tissue ROI. On 40 held-out cases, VoxelSynth3D reduced RMSE from 801.48 to 786.18 HU (paired gain 15.30 HU, 95% CI 11.68-19.23), improving every case and exceeding the evaluated 3D Gaussian smoother by 13.58 HU. Clean-edge agreement decreased next to metal but exceeded input beyond 5 mm. Thus, VoxelSynth3D provides case-consistent within-distribution tissue-error reduction with a localized structural tradeoff. Spacing-aware sensitivity retained aggregate broad-region improvement and identified near-metal calibration as a target.

Comment
7 pages, 7 figures. Accepted for publication at BHI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

OpenMASC: An Open-Source Pipeline for Cross-Trajectory Metal-Aware Sampling and Correction in Accelerated MRI

cs.CV ·2026-09-26 ·Zhengyi Lu, Ming Lu, Chongyu Qu, Junchao Zhu, Junlin Guo +9 more
code/data similarity 0.68
Abstract

Metal implants corrupt MRI measurements throughout $k$-space, yet existing accelerated MRI methods assume clean data and most metal artifact reduction approaches assume fully sampled acquisitions. No public dataset provides paired $k$-space and images with and without metal for the same anatomy, and no framework jointly addresses artifact-aware acquisition and reconstruction across sampling trajectories. We present OpenMASC, an open-source pipeline covering the full workflow from data generation to deployment. A physics-based data generation module converts public CT volumes into paired clean and metal-corrupted MRI data in both Cartesian and radial formats. MA-VarNet, an unrolled reconstruction network with a per-cascade DC Rectifier, corrects artifacts that data-consistency steps reintroduce from corrupted measurements. A reinforcement learning agent actively selects $k$-space readouts and co-trains with the reconstruction network through a decoupled three-stage procedure. The framework is trajectory-agnostic except for the data-consistency operator, supporting both Cartesian and radial acquisition without architectural changes. Experiments on two datasets at $4\times$ and $8\times$ acceleration demonstrate consistent improvements over conventional and learned baselines on both trajectories.

0.31

Splat-based Metal Artifact Reduction in Cone-Beam CT via Polychromatic Modeling

cs.CV cs.GR ·2026-08-13 ·Kiseok Choi, Inchul Kim, Jaemin Cho, Hyeongjun Cho, Min H. Kim
published similarity 0.68
Abstract

Cone-beam computed tomography (CBCT) enables volumetric reconstruction from X-ray projections, but suffers from severe artifacts--especially beam hardening--when imaging materials with high attenuation such as metals. These artifacts arise from the polychromatic nature of X-rays and are not properly addressed by conventional monochromatic reconstruction algorithms. While recent neural representation-based methods offer improved reconstruction quality, they are computationally expensive and often impractical for deployment. We propose a novel physics-inspired, self-calibrating metal artifact reduction method that efficiently reconstructs 3D CBCT volumes while correcting beam hardening artifacts. Our method integrates a polychromatic X-ray projection model, material-dependent attenuation profiles, and system response modeling into a Gaussian Splatting framework. Unlike prior work, we eliminate the need for manual metal masks or strong prior assumptions, and we optimize both reconstruction parameters and X-ray spectral characteristics jointly during training. We further introduce a high-fidelity synthetic CBCT dataset generation pipeline validated on Monte-Carlo x-ray simulation toolbox and release new datasets with severe metal-induced artifacts to support the community. This is the first splat-based method for reducing beam hardening in CBCT. Extensive experiments on both synthetic and real-world datasets demonstrate that our method outperforms state-of-the-art approaches in artifact suppression and reconstruction accuracy.

0.54

Uncovering the Invisible in Routine Radiology: Cross-Modal Detection of MRI-Verified Soft-Tissue Pathologies from CBCT via Physics-Guided 3D Self-Supervised Learning

eess.IV cs.CVcs.LG ·2026-11-17 ·Evgeny Alves Limarenko
similarity 0.63
Abstract

Routine X-ray modalities like cone-beam computed tomography (CBCT) are optimized for high-contrast mineralized tissues, leaving soft-tissue abnormalities buried beneath photon noise and below human visual perception. Thus, detecting non-calcified pathologies requires secondary magnetic resonance imaging (MRI). We demonstrate that sub-visual radiographic signatures of soft-tissue pathology are physically preserved within routine CBCT scans and can be extracted for opportunistic screening using a targeted, physics-guided deep learning pipeline, even under extreme paired-data scarcity. Using the temporomandibular joint (TMJ) as a model system (N = 212 paired CBCT-MRI joints), we address the severe overfitting of high-capacity 3D networks through a two-stage framework. First, we employ a frozen full-grid 3D masked autoencoder (BertsWin) pre-trained on 6,550 unlabeled CBCT volumes via the GradientConductor (GCond) optimizer and an anatomy-aware objective (PhysLoss) redirecting gradient flow into the [-300, 300] HU soft-tissue window. Second, automated localization of the condylar zenith drives a deterministic 3D cropping that eliminates 81% of background osseous variance. Evaluated via a patient-isolated 3x10-fold stratified cross-validation protocol, a statistically robust sub-visual signal for MRI-verified synovial effusion (ROC AUC = 0.793) emerges exclusively from representations pre-trained with the PhysLoss and GCond regime. Crucially, only this setup captures true 3D anatomical chirality (p < 0.001) and high intra-patient structural consistency (0.791) over inter-patient noise; conversely, identical architectures pre-trained with standard L2 loss or unmasked variance decomposition (MVC) collapse to random guessing. These findings establish a generalizable paradigm for repurposing routine, low-contrast radiographic scans into opportunistic screening tools for occult soft-tissue disease.

0.18

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.59
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32

LBW-NPS: A Local Band-Weighted Noise Power Spectrum Loss for Texture-Preserving Low-Dose CT Denoising

eess.IV ·2026-11-19 ·Fatma Elif Yalçındağ, Mehmet Ozan Ünal, Metin Ertaş, İsa Yıldırım
code/data similarity 0.59
Abstract · 5 pages, 3 figures, 2 tables. Submitted to IEEE ISBI 2027. Code: https://github.com/itu-biai/lbw-nps

Low-dose CT denoising should suppress noise while retaining the local texture of the reference image. Matching a pooled spectrum can overlook regional discrepancies, whereas pixel losses alone can favor overly smooth outputs. We propose a local band-weighted noise power spectrum loss (LBW-NPS) that compares spectral energies within overlapping Hann-tapered patches, without tissue-specific loss conditioning. Each valid patch contributes a weighted squared log-energy difference across three frequency bands, alongside an $L_1$ reconstruction term. We compare LBW-NPS against $L_1$-only training and five auxiliary-loss baselines using the same U-Net and three seeds on DeepLesion slices with simulated low-dose acquisitions, including patch-scale ablations and lung, soft-tissue, and bone evaluations. On 220 test slices from 31 patients, LBW-NPS reduces a local spectral gap related to the loss, on $64\times64$-pixel evaluation windows, by 31.9% relative to pooled band-weighted NPS, without a statistically significant PSNR change. This improvement is supported by lower errors relative to the reference in average NPS frequency and gray-level co-occurrence matrix (GLCM) measures not used in the loss, evaluated in homogeneous soft tissue. Local band-power matching therefore improves regional texture agreement without changing the denoising architecture.

0.52

When Misalignment Becomes Supervision: Structured Label Noise in Supervised Synthetic CT Generation

cs.CV ·2026-09-24 ·Valentin Boussot, Cedric Hemon, Caroline Lafond, Jean-Claude Nunes, Jean-Louis Dillenseger
similarity 0.59
Abstract · 23 pages, 4 figures, 19 tables

Supervised synthetic CT (sCT) generation is commonly trained and evaluated as voxel-wise regression against registered reference CT images. In practice, MRI-CT and CBCT-CT pairs are aligned through registration procedures that leave residual misalignments. These residuals are not independent intensity noise but spatially coherent geometric discrepancies that act as structured label noise. We investigate how this registration-induced bias affects supervised MRI-to-CT and CBCT-to-CT synthesis on 1,784 paired patients covering five anatomical regions. Voxel-wise scores strongly depend on the consistency between the registration used to build the training targets and the one used for evaluation: models score best when both conventions match, showing that networks partly learn the geometric convention of the registration pipeline and that standard metrics reward it. Training on more anatomically consistent registrations reduces prediction variability and improves out-of-distribution robustness, and CT-only controls show that registration alone produces metric errors in the range of top challenge submissions. To mitigate the limits of voxel-wise supervision, we introduce a perceptual loss computed in the feature space of a pretrained Segment Anything encoder. Compared with MAE-only and VGG-based objectives, it improves downstream segmentation and yields sharper, more structurally coherent sCT. Perceptual and voxel-wise metrics disagree under imperfect alignment and agree when the evaluation geometry is reliable. These results identify registration-induced bias as a central confounder in supervised sCT generation and argue for complementing voxel-wise agreement with anatomy-oriented evaluation criteria.

0.27

VascuSR: Iterative Anatomy-Aware Diffusion for CT Super-Resolution

cs.CV cs.AIcs.LG ·2026-10-14 ·Hairong Ni, Jiahe Huang, Minghao Guo, Wojciech Matusik, Rose Yu
similarity 0.59
Abstract

Generative super-resolution (SR) can recover sharp detail in computed tomography (CT) images from severely downsampled observations, but the missing high-frequency content is not uniquely determined by the low-resolution input. Consequently, visually plausible reconstructions may contain anatomically unsupported vascular detail, such as missing, spurious, or incorrectly connected vessels. To overcome this challenge, we introduce VascuSR, an iterative anatomy-aware diffusion framework that combines image reconstruction with explicit 3D vascular guidance. First, to provide richer anatomical guidance, we use an explicit 3D vascular representation that captures structural information beyond individual slices. This representation also simplifies vascular refinement by allowing a lightweight 3D generative refiner to focus on vascular structure rather than complex CT appearance. Second, to guide slice-wise SR, a lightweight anatomy controller injects the refined structure into the diffusion decoder, while iterative feedback updates this guidance from each new SR volume. On re-annotated MSD Task08 and HVM datasets, VascuSR outperforms interpolation and learning-based SR baselines in segmentation accuracy (Dice and clDice) and 3D vascular structure (connectivity and mean centerline distance), while maintaining image quality comparable to its SR backbone. Compared with learning-based baselines, VascuSR reduces class-averaged connected-component counts by over 20% on both datasets and mean centerline distance by over 10% on MSD.

0.23

Field-of-View Extension in Dental Cone-Beam CT via Implicit Neural Representations and Diffusion Model-Based Refinement

cs.CV cs.AI ·2026-09-23 ·Susanne Schaub, Florentin Bieder, Matheus L. Oliveira, Yulan Wang, Buyanbileg Sodnom-ish +3 more
publishedcode/data similarity 0.58
Abstract · Accepted at MICAD 2026

Dental cone-beam computed tomography (CBCT) systems often employ detector configurations that provide a truncated field of view (FOV) that only captures a small part of the patient's anatomy. In this work, we aim to reconstruct an extended FOV using projections of truncated FOV scans. To this end, we propose a three-stage framework that consists of (1) an implicit neural representation (INR) for estimating missing parts of the truncated projection data, (2) an iterative reconstruction for generating a secondary volumetric image with improved anatomical consistency and (3) a fast diffusion model for image enhancement. The proposed approach combines the strengths of continuous representations, physics-based reconstruction and generative refinement within a unified pipeline for truncated CBCT imaging. Experimental results demonstrate that the method effectively reduces truncation artifacts, improves the reconstruction of structures extending beyond the original FOV and produces images with enhanced quality. Our code is publicly available at https://github.com/SusanneSchaub/CBCT-FOV-Extension.

0.37