CS Paper Radar

Field-of-View Extension in Dental Cone-Beam CT via Implicit Neural Representations and Diffusion Model-Based Refinement

Susanne Schaub, Florentin Bieder, Matheus L. Oliveira, Yulan Wang, Buyanbileg Sodnom-ish, Dorothea Dagassan-Berndt, Michael M. Bornstein, Philippe C. Cattin

cs.CV cs.AI ·submitted 2026-09-23 13:43 UTC · v1
publishedcode/data

Abstract

Dental cone-beam computed tomography (CBCT) systems often employ detector configurations that provide a truncated field of view (FOV) that only captures a small part of the patient's anatomy. In this work, we aim to reconstruct an extended FOV using projections of truncated FOV scans. To this end, we propose a three-stage framework that consists of (1) an implicit neural representation (INR) for estimating missing parts of the truncated projection data, (2) an iterative reconstruction for generating a secondary volumetric image with improved anatomical consistency and (3) a fast diffusion model for image enhancement. The proposed approach combines the strengths of continuous representations, physics-based reconstruction and generative refinement within a unified pipeline for truncated CBCT imaging. Experimental results demonstrate that the method effectively reduces truncation artifacts, improves the reconstruction of structures extending beyond the original FOV and produces images with enhanced quality. Our code is publicly available at https://github.com/SusanneSchaub/CBCT-FOV-Extension.

Comment
Accepted at MICAD 2026

Closest papers

Nearest neighbours by meaning across the whole index.

SparseTokenGS: Gaussian-based Sparse-View CBCT Reconstruction via Reusable Token Pool

cs.CV cs.AI ·2026-10-28 ·Zihan Deng, Zhenzhen Gong, Yujie Liu, Jiaxin Gong, Dingkun Liu +8 more
code/data similarity 0.70
Abstract · 10 pages, 12 figures. Submitted to IEEE Transactions on Medical Imaging

Sparse-view cone-beam computed tomography is widely used for fast, low-dose volumetric imaging and lesion localization in dentistry and image-guided interventions, but it introduces severe artifacts. Feed-forward Gaussian methods transfer the reconstruction cost to training and decode each coordinate from projection-aligned features and neighboring anchors. However, information from the whole scan is written only when the field is constructed and cannot be retrieved during coordinate decoding, leaving the volume inconsistent within the scan. This is a common limitation of such methods: once the field is fixed, decoding uses only local features and reconstruction quality drops substantially. We propose SparseTokenGS, a Gaussian-based method for sparse-view cone-beam computed tomography reconstruction via a reusable token pool. Anchor Token Fusion and Point-Token Attention query this shared pool at the anchors and at the query coordinates, respectively. The local Gaussian prior is retained, and the volume is reconstructed in one forward pass, without per-scan optimization or a projection-domain loss. On three public chest and dental datasets, SparseTokenGS achieves the highest reconstruction performance among the compared methods. On clinical dental scans, reconstruction from only six projections reaches 29.51 decibels in peak signal-to-noise ratio and a structural similarity of 0.842 against the full-view reference, and off-the-shelf tooth-and-pulp segmentation keeps these structures separable for root-canal localization. Experiments on volcanic rock and chicken show performance after same-object adaptation. A reusable token pool gives feed-forward reconstruction a mechanism that keeps scan-wide context available through decoding and can benefit future rapid clinical lesion localization and analysis. The code is available at: https://github.com/FrankDengAI/SparseTokenGS.

0.36

AD-GS: Anatomical Density-guided 3D Gaussian Splatting for Sparse-View Dental CBCT Reconstruction

cs.CV ·2026-10-10 ·Zonglin Li, Kexian Xie, Feiran Li, Chu Zhou, Yixing Huang +3 more
code/data similarity 0.69
Abstract

Sparse-view Cone-Beam Computed Tomography (CBCT) reconstruction is essential for reducing radiation dose and scan effort, but remains underconstrained due to limited projection information. Recent 3D Gaussian Splatting (3DGS)-based CBCT reconstruction methods rely on gradient-driven densification, which becomes unstable under sparse acquisition and often leads to over-smoothed structures. We propose AD-GS, an Anatomical Density-guided 3D Gaussian Splatting framework that formulates Gaussian densification as an attenuation-aware Markov Chain Monte Carlo (MCMC) sampling process. By interpreting Gaussians as samples from an underlying anatomical attenuation distribution, AD-GS adaptively concentrates representation capacity in high-attenuation regions, enabling sharper structural boundaries under sparse projections. To further constrain reconstruction, we incorporate a semantic regularization based on zero-shot features from Segment Anything in Medical Images, enforcing multi-view consistency through semantic priors. Experiments on the ToothFairy3 dental CBCT dataset demonstrate that AD-GS achieves superior structural fidelity and boundary preservation compared with existing 3DGS-based approaches under sparse-view settings within the dental and maxillofacial setting. Code is available at https://github.com/yulinjiaxue/AD-GS-BMVC2026.

0.29

Accelerating Variational Cone-Beam CT Reconstruction with Learned Warm Starts

eess.IV cs.AIcs.CV ·2026-11-13 ·Héloïse Dudoignon, Clément Delmas, Laurent Facq, Clair Poignard, Baudouin Denis de Senneville
similarity 0.69
Abstract · Submitted to IEEE ISBI 2027

Variational reconstruction provides a rigorous framework for cone-beam computed tomography (CBCT) by combining an explicit acquisition model with image priors. However, iterative optimization remains computationally demanding, particularly under severe noise and sparse-view conditions. Although learning-based methods achieve high reconstruction quality, they often replace the original variational formulation with learned optimization schemes or nonlinear equilibrium models. We propose a neural network-guided warm-start framework that accelerates variational reconstruction while preserving its original formulation. Projection data are first reconstructed using the Feldkamp-Davis-Kress (FDK) algorithm, and the resulting image is refined by an image-domain neural network. The network output is used solely to initialize the subsequent model-based optimization, leaving the forward model, data-fidelity term, regularization, and optimization scheme unchanged. A pre-regularization step further improves compatibility with the variational priors. Experiments on pelvic CT images from the SynthRAD2025 challenge show a more than threefold reduction in reconstruction time while maintaining comparable image quality.

0.21

EPC-RawDC: Equivariant Physics Constrained 3D Diffusion with Raw Data Consistency for CBCT to CT Image Synthesis

cs.CV cs.AIphysics.med-ph ·2026-10-29 ·Alzahra Altalib, Chunhui Li, Alessandro Perelli
code/datahot direction similarity 0.67
Abstract · 10 pages, 4 figures, 8 tables

Cone beam computed tomography (CBCT) is widely used for image guided and adaptive radiotherapy, but scatter, noise, reconstruction artifacts, and inaccurate Hounsfield units limit its quantitative use. Recent diffusion approaches for CBCT to CT synthesis remain largely image driven, with limited use of the underlying acquisition physics. We propose EPC-RawDC, a conditional 3D latent diffusion framework that combines volumetric generative modeling with two complementary constraints derived from the same scanner specific CBCT forward model. First, geometry equivariant projection constraint exploits the rotational equivariance of the CBCT forward operator by supervising the synthesized CT through correspondingly transformed reference projections. Second, raw data consistency uses noisy projection measurements of the individual acquisition as scan specific supervision during training. The framework was evaluated on two independent clinical cohorts with distinct scanner geometries and projection sources. For JUST, the physics constraints used measured clinical raw CBCT projections acquired with an Elekta system, whereas for SynthRAD2025 the projection data were simulated from the reference CT using a Varian geometry with Poisson photon statistics. EPC-RawDC achieved an SSIM of 0.97 in both cohorts and improved PSNR over DDPM by 2.66 dB on SynthRAD2025 and 2.10 dB on JUST, while reducing mean MAE by 20.3% and 19.0%, respectively. On SynthRAD2025, projection consistency and equivariant errors were reduced by 55.0% and 41.4% relative to DDPM. These results demonstrate that combining a volumetric diffusion prior with scanner geometry and scan specific projection measurements improves quantitative CBCT to CT synthesis across both simulated and measured projection domains. Code available after publication at https://github.com/ALZAHRAALTALIB/EPC-RawDC.

0.37

Feed-Forward Hierarchical Gaussian Diffusion for Extreme CT Reconstruction

cs.CV ·2026-08-15 ·Yuezhe Yang, Li Cheng
benchmarkcode/data similarity 0.67
Abstract

Reconstructing three-dimensional computed tomography (CT) from severely constrained projections is highly ill-posed. Sparse angular sampling, restricted angular coverage, and low photon counts can occur individually or jointly, obscuring global anatomy and local tissue detail. Many learned CT reconstruction methods are tailored to a single dominant degradation. Existing diffusion and Gaussian approaches commonly recover global structure and local detail within a shared representation. We propose HiGDiff, a feed-forward hierarchical Gaussian diffusion framework that decomposes reconstruction both spatially and from structure to detail. Physics-conditioned anatomical anchors and a foreground capacity field allocate learnable Gaussian primitives to informative regions. A structure diffusion stage first recovers global attenuation geometry, and its learned representation conditions a detail diffusion stage for residual boundaries and tissue transitions. The resulting Gaussian banks are rendered as attenuation fields and further refined by a gradient-isolated residual module. Experiments on three distinct CT benchmark datasets demonstrate state-of-the-art reconstruction performance across isolated, paired, and joint degradation settings, including improvements of 5.81 dB in macro-average peak signal-to-noise ratio (PSNR) and 0.113 in structural similarity index measure (SSIM) on the Low Dose CT Image and Projection Data (LDCT-PD) collection. Code and experimental configurations are openly available at https://github.com/Bean-Young/HiGDiff.

0.24

Taming Neural Fields with a Frequency-Lipschitz Curriculum for Sparse-View CT Reconstruction

cs.CV cs.LG ·2026-11-11 ·Songtao Hu, Jingrui Wu, Hong Ding, Fanhao Zhu, Yunhao Liu +1 more
similarity 0.66
Abstract

Sparse-view computed tomography (SVCT) reduces radiation dose by acquiring fewer projection views, but the resulting under-determined inverse problem requires careful regularization to prevent reconstruction algorithms from fitting streak artifacts and hallucinated structures. Existing implicit neural representation (INR) methods rely on implicit spectral bias or iterative external denoising, yet they provide limited control over when high-frequency capacity is exposed during optimization. To address this limitation, we propose FLIC (Frequency-Lipschitz INR Curriculum), a capacity-controlled self-prior INR framework that makes the network's representational capacity explicit and schedulable. The core of our method is a joint frequency-Lipschitz curriculum that couples random Fourier feature encoding with spectrally normalized MLP decoding under non-uniform Lipschitz budgets, guiding reconstruction along a coarse-to-fine trajectory from stable global anatomy to fine details. The terminal capacity is automatically calibrated from FBP gradient statistics, enabling scan-adaptive regularization without per-scan manual tuning of the terminal Lipschitz budget. We further introduce a prior-guided adaptive ray sampling strategy that concentrates integration samples near high-gradient anatomical boundaries, improving forward-model fidelity. The entire framework operates in a single training stage without iterative denoising, enabling efficient per-image reconstruction. Extensive experiments on four public CT datasets under noise-free and low-dose settings show that our method achieves state-of-the-art unsupervised reconstruction quality with consistent performance across diverse anatomical structures.

0.13

DeBoneDiT: Depth-Driven Conditional Bridge Diffusion Transformers for Bone Suppression in Chest X-Ray Images

cs.CV ·2026-10-14 ·Yifei Sun, Fenglei Fan, Junhao Jia, Wenming Deng, Hongxia Xu +2 more
benchmark similarity 0.66
Abstract · 19 pages, 13 figures

Chest X-Ray (CXR) is a primary modality for diagnosing pulmonary diseases, yet the overlap of bony structures often obscures critical radiographic findings, increasing the risk of diagnostic uncertainty. While Dual-Energy Subtraction (DES) is the clinical benchmark for bone suppression, its widespread adoption is primarily hindered by specialized hardware requirements and increased radiation exposure. Recently, diffusion-based generative models have shown promise for this task, yet they are still constrained by reconstruction-biased latent compression, prior-induced domain gap, and a scarcity of high-quality paired datasets. To address these challenges, we propose DeBoneDiT, a depth-driven conditional bridge diffusion Transformer architecture for efficient high-resolution bone suppression. We first introduce Depth Auto-Encoder (DAE), a structure-aware vision tokenizer for latent compression. By incorporating a multi-level depth feature loss derived from the pretrained Depth Anything V2 encoder, DAE preserves both visual fidelity and structural consistency. Second, we formulate bone suppression as a source-conditioned Brownian bridge diffusion process, leveraging CXRs as both the diffusion prior and structural guidance to narrow the source-to-target domain gap and maintain anatomical plausibility. Furthermore, we have constructed and released SZCH-X-Rays, the largest publicly available high-quality paired dataset for bone suppression to date, comprising 741 pairs of CXR and DES soft tissue images. Extensive experiments and downstream evaluation demonstrate that DeBoneDiT achieves superior bone suppression performance with reduced computational overhead.

0.19

Learning Where and What to Lift for Bi-planar X-ray-to-CT Reconstruction

cs.CV cs.AI ·2026-08-18 ·Yifei Wu, Yicheng Wu, Qiang Ma, Qi Chen, Renyang Gu +3 more
similarity 0.65
Abstract

X-ray imaging can be approximately modeled as the projection of an underlying volumetric attenuation field, with each measurement recording the accumulated attenuation along a corresponding ray path. Reconstructing a CT volume from only a few X-ray views is therefore severely ill-posed, as the projections collapse depth information and leave 3D locations of anatomical regions and their corresponding intensity distributions highly entangled and ambiguous. We observe that once the spatial organization of anatomical regions is established, estimating their CT intensities becomes substantially more tractable. Motivated by this, we propose LiftXR, an interleaved, geometry-guided framework that explicitly incorporates spatial layout recovery into CT reconstruction. Specifically, a layout lifter first generates a 3D anatomical layout from bi-planar X-rays, providing spatial guidance for an intensity renderer to reconstruct a CT volume. An anatomical parser then performs volumetric perception on the reconstruction, exploiting its spatially resolved boundary and intensity cues to recover a refined anatomical layout. This transition from projection-conditioned layout generation to reconstruction-conditioned anatomical perception allows the parsed layout to provide feedback for region-specific intensity calibration. Extensive experiments on two public datasets demonstrate that LiftXR consistently outperforms recent X-ray-to-CT reconstruction methods, establishing a new state of the art. Moreover, the reconstructed CT achieves superior performance in external downstream segmentation, indicating improved anatomical fidelity. Code will be released.

0.22