CS Paper Radar

DeBoneDiT: Depth-Driven Conditional Bridge Diffusion Transformers for Bone Suppression in Chest X-Ray Images

Yifei Sun, Fenglei Fan, Junhao Jia, Wenming Deng, Hongxia Xu, Changmiao Wang, Ruiquan Ge

cs.CV ·submitted 2026-10-14 02:46 UTC · v1
benchmark

Abstract

Chest X-Ray (CXR) is a primary modality for diagnosing pulmonary diseases, yet the overlap of bony structures often obscures critical radiographic findings, increasing the risk of diagnostic uncertainty. While Dual-Energy Subtraction (DES) is the clinical benchmark for bone suppression, its widespread adoption is primarily hindered by specialized hardware requirements and increased radiation exposure. Recently, diffusion-based generative models have shown promise for this task, yet they are still constrained by reconstruction-biased latent compression, prior-induced domain gap, and a scarcity of high-quality paired datasets. To address these challenges, we propose DeBoneDiT, a depth-driven conditional bridge diffusion Transformer architecture for efficient high-resolution bone suppression. We first introduce Depth Auto-Encoder (DAE), a structure-aware vision tokenizer for latent compression. By incorporating a multi-level depth feature loss derived from the pretrained Depth Anything V2 encoder, DAE preserves both visual fidelity and structural consistency. Second, we formulate bone suppression as a source-conditioned Brownian bridge diffusion process, leveraging CXRs as both the diffusion prior and structural guidance to narrow the source-to-target domain gap and maintain anatomical plausibility. Furthermore, we have constructed and released SZCH-X-Rays, the largest publicly available high-quality paired dataset for bone suppression to date, comprising 741 pairs of CXR and DES soft tissue images. Extensive experiments and downstream evaluation demonstrate that DeBoneDiT achieves superior bone suppression performance with reduced computational overhead.

Comment
19 pages, 13 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Anatomy-Decomposed Chest Computed Tomography (CT) Projections as Scalable Supervision for Bone Suppression in Chest Radiographs

cs.CV ·2026-09-21 ·Mrunmay Angaitkar, Piyush Kumar, Aarjav Satia, Pranav Rao, Ashish Mittal +2 more
code/data similarity 0.73
Abstract

Bone overlap can obscure abnormalities in chest radiographs, while scarce paired training data limit supervised bone suppression. We address this challenge with a digitally reconstructed radiograph (DRR) framework that converts chest computed tomography (CT) into paired supervision for component suppression. A novel bone segmentation algorithm enables CT decomposition into bone, non-lung soft-tissue, and lung components, which are projected separately. Their weighted combination yields synthetic radiographs with pixel-registered component images that sum exactly to the full DRR. Models trained on these data suppress bone or lung components by predicting the target component and recovering the remainder by subtraction, transferring to real radiographs without real paired training data. As an extension, their outputs on real radiographs provide target domains for unpaired, component-wise DRR translation, reducing the appearance gap while retaining anatomical details. Across multiple public datasets, downstream detection experiments demonstrate the utility of bone suppression, with gains concentrated on abnormalities with substantial bone overlap. Compared with open-source DRR engines applied to the same CTs, our unmodified DRRs achieve comparable realism and preservation of label-relevant anatomy, while translated DRRs achieve the best Fréchet inception distance (FID), lung-field sharpness, and agreement with source-CT anatomy among the evaluated methods. Models and inference code: https://huggingface.co/qureaiorg/bone-suppression ; Translated projections: https://huggingface.co/datasets/qureaiorg/ct2xr-projections.

0.35

3D Diffusion Models for Medical Imaging

cs.CV ·2026-10-19 ·Frank-Peter Schilling, Daniel Barco, Philipp Denzel, Marc Stadelmann
publishedsurvey similarity 0.69
Abstract · 27 pages, accepted for publication in Informatics in Medicine Unlocked

Generative deep learning methods such as Variational Autoencoders, Generative Adversarial Networks or Diffusion Models have achieved remarkable results in image synthesis. In particular, Diffusion Models have demonstrated superior image fidelity and sample diversity compared to other approaches on standard benchmarks, while also offering more flexible training dynamics as evidenced both in natural image domains and in medical applications. In medical imaging including Computed Tomography, Magnetic Resonance Imaging or Positron Emission Tomography, such models have various important use-cases including data augmentation, domain transfer, image reconstruction, inpainting, image augmentation and artifact correction. Further, generated images can be conditioned on patient characteristics, medical reports, segmentation masks or other images. Specific challenges arise due to the 3D volumetric nature of medical images, which translate to substantial demands in terms of memory, compute, and training data. This article provides a comparative overview of 3D Diffusion Models which have been developed for medical images, with a focus on current performance, limitations, and an outlook for future work.

0.23

3D CT-to-PET Translation via Latent Brownian Bridge Diffusion

cs.CV cs.AI ·2026-09-11 ·Sarita Mourya, Francesco Di Feola, Pierangelo Veltri, Paolo Soda
similarity 0.68
Abstract

Computed tomography (CT) and positron emission tomography (PET) provide complementary anatomical and functional information for cancer diagnosis and treatment planning. However, the widespread use of PET is limited by high radiation exposure, elevated costs, and restricted availability. To address these limitations, deep learning-based CT-to-PET translation has emerged as a promising approach for synthesizing PET-like information directly from CT images, although accurately modeling the large cross-modal gap remains challenging. In this work, we propose a 3D CT-to-PET translation framework based on latent Brownian Bridge Diffusion (BBDM). The method consists of two stages. First, a Variational Autoencoder (VAE) is trained on paired CT-PET patches, integrating contrastive learning to improve latent alignment between anatomical and metabolic representations. Second, a BBDM is trained in the latent space to translate CT latent representations into their corresponding PET counterparts. The translated PET latents are then decoded and stitched to reconstruct the final 3D PET volume. We evaluate the proposed approach on two publicly available datasets. Quantitative results based on image fidelity and lesion-level PET-specific metrics demonstrate improved performance compared with competing methods. In particular, the proposed approach improves PET signal fidelity, better preserves clinically relevant uptake patterns, and shows improved performance in preserving small-lesion metabolic activation, paving the way for virtual imaging applications.

0.22

Beyond Training from Scratch: Foundation Models for Data-Efficient and Generalizable Cardiac MRI Reconstruction

cs.CV ·2026-10-06 ·Anam Hashmi, Mayug Maniparambil, Julia Dietlmeier, Kathleen M. Curran, Noel E. O'Connor
publishedcode/data similarity 0.67
Abstract · Accepted at ECCVW 2026

Cardiac magnetic resonance imaging reconstruction aims to recover high-quality images from undersampled acquisitions, enabling faster scans while preserving diagnostic fidelity. Recent reconstruction methods are typically trained from scratch and often require large amounts of task-specific data, limiting their robustness under data scarcity and distribution shifts. In this work, we investigate whether pretrained vision foundation models can serve as effective priors for accelerated cardiac MRI reconstruction. We propose a reconstruction framework that integrates frozen and parameter-efficiently adapted visual encoders, including CLIP, BiomedCLIP, and DINOv2, within a transformer-based reconstruction architecture. Extensive experiments on the CMRxRecon2023 and CMRxRecon2024 benchmarks demonstrate that pretrained representations consistently outperform a transformer trained from scratch across multiple acceleration factors. We further evaluate performance under limited supervision and cross-dataset transfer, showing that foundation models provide superior data efficiency and generalization. While frozen representations are particularly effective in extreme low-data regimes, Low-Rank Adaptation (LoRA) yields additional gains when moderate amounts of training data are available. Among the evaluated backbones, DINOv2 achieves the strongest overall performance. These findings highlight the potential of vision foundation models as robust and transferable priors for cardiac MRI reconstruction.

0.31

Physics-Guided Flow Matching for CT Image Reconstruction

cs.AI cs.CV ·2026-08-28 ·Davide Evangelista
similarity 0.67
Abstract · 16 pages, 6 figures, 2 tables

Deep generative models have recently emerged as powerful priors for solving ill-posed inverse problems in CT, with diffusion-based approaches achieving state-of-the-art reconstruction performance. However, diffusion models typically rely on stochastic sampling procedures, long inference trajectories, and carefully tuned noise schedules, which can limit computational efficiency and numerical stability, especially at high spatial resolutions. In this work, we investigate Flow Matching as an alternative generative prior for CT reconstruction. We train a high-resolution Rectified Flow Matching model on 256x256 chest images from the Mayo Clinic Low-Dose CT dataset. To mitigate overfitting and limited anatomical variability, we employ a two-stage training strategy consisting of an initial phase with strong, anatomically informed data augmentation, followed by a fine-tuning phase with reduced or no augmentation to refine structural fidelity. The resulting model is capable of generating high-quality and anatomically coherent CT-like images, serving as a strong learned prior. We then evaluate multiple reconstruction methods specifically designed for Flow Matching models, including Plug-and-Play Flow, FlowDPS, Flower, and Flow-Priors (ICTM), and compare them against state-of-the-art diffusion-based reconstruction algorithms such as DDRM, DPS, and DiffPIR. Experimental results across several CT inverse problem settings show that Flow Matching-based approaches consistently outperform diffusion-based methods in terms of PSNR, SSIM, and perceptual quality, while requiring fewer sampling steps. Finally, we publicly release the trained Flow Matching model and accompanying code to facilitate reproducibility and future research. Overall, this work demonstrates that Flow Matching provides a stable, efficient, and effective alternative to diffusion models for high-resolution CT image reconstruction.

0.42

PhyDiCT: Plug-and-Play CT Reconstruction from Sparse X-Rays via Differentiable Rendering and Strong Priors

cs.CV ·2026-10-07 ·Weicheng Dai, Shantanu Ghosh, Kayhan Batmanghelich
top venuecode/data similarity 0.67
Abstract · Accepted at MICCAI 2026; to appear in LNCS 16888

Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric information. We propose PhyDiCT, a training-free framework that integrates a differentiable Physics-based forward model, grounded in the Beer-Lambert law, with a text-conditioned Diffusion as a strong prior to reconstruct 3D lung CT images. We refer to our approach as training-free since the prior model is used without fine-tuning, and our goal is to steer the denoising procedure to generate samples consistent with X-ray observations. We guide the diffusion generation using Split Gibbs sampling to jointly optimize for projection fidelity (reward) and consistency with prior knowledge. Also, we introduce a test-time refinement step that enhances image realism and anatomical coherence. We extensively evaluate our method on publicly available 3D CT datasets using both perceptual and semantic metrics, demonstrating that it surpasses existing plug-and-play diffusion and fully trained reconstruction approaches. Our findings highlight that combining a strong generative prior with the underlying physics of image formation substantially improves reconstruction quality, e.g., 7.5\% improvement on SSIM compared to full training methods. Code will be released at https://github.com/batmanlab/PhyDiCT.

0.44

B-MIM: Biased Masked Image Modeling for Generalizable Segmentation of Fine-Grained Anatomical Structures

cs.CV ·2026-08-25 ·Sebastián González, Karen Sanchez, José M. Saavedra, Marcelo Pizarro, Bernard Ghanem
published similarity 0.67
Abstract · Published at MedAGI in MICCAI 2026

Self-supervised pretraining enables transferable representations for medical imaging, yet most CT encoders remain biased toward coarse semantic understanding, limiting their sensitivity to fine-grained anatomical structures such as vessels or small tumors. In this paper, we introduce Biased Masked Image Modeling (B-MIM), a modification of the iBOT objective that stochastically reduces global semantic alignment to prioritize local patch reconstruction. This bias encourages the encoder to capture high-frequency morphological details and structural continuity. We curate a multi-institutional CT abdominal dataset of 9,955 filtered studies from 17 public sources and pretrain a 3D Swin Transformer backbone using B-MIM. Across inter-dataset experiments on liver vessel segmentation, the proposed encoder improves topological fidelity (clDice) and achieves competitive Dice scores in tumor segmentation, compared to fully fine-tuned baselines, despite updating only a fraction of the parameters. Our results suggest that reducing global semantic pressure during pretraining enhances generalization to intricate anatomical structures.

0.25

Field-of-View Extension in Dental Cone-Beam CT via Implicit Neural Representations and Diffusion Model-Based Refinement

cs.CV cs.AI ·2026-09-23 ·Susanne Schaub, Florentin Bieder, Matheus L. Oliveira, Yulan Wang, Buyanbileg Sodnom-ish +3 more
publishedcode/data similarity 0.66
Abstract · Accepted at MICAD 2026

Dental cone-beam computed tomography (CBCT) systems often employ detector configurations that provide a truncated field of view (FOV) that only captures a small part of the patient's anatomy. In this work, we aim to reconstruct an extended FOV using projections of truncated FOV scans. To this end, we propose a three-stage framework that consists of (1) an implicit neural representation (INR) for estimating missing parts of the truncated projection data, (2) an iterative reconstruction for generating a secondary volumetric image with improved anatomical consistency and (3) a fast diffusion model for image enhancement. The proposed approach combines the strengths of continuous representations, physics-based reconstruction and generative refinement within a unified pipeline for truncated CBCT imaging. Experimental results demonstrate that the method effectively reduces truncation artifacts, improves the reconstruction of structures extending beyond the original FOV and produces images with enhanced quality. Our code is publicly available at https://github.com/SusanneSchaub/CBCT-FOV-Extension.

0.37