CS Paper Radar

When Misalignment Becomes Supervision: Structured Label Noise in Supervised Synthetic CT Generation

Valentin Boussot, Cedric Hemon, Caroline Lafond, Jean-Claude Nunes, Jean-Louis Dillenseger

cs.CV ·submitted 2026-09-24 11:12 UTC · v1

Abstract

Supervised synthetic CT (sCT) generation is commonly trained and evaluated as voxel-wise regression against registered reference CT images. In practice, MRI-CT and CBCT-CT pairs are aligned through registration procedures that leave residual misalignments. These residuals are not independent intensity noise but spatially coherent geometric discrepancies that act as structured label noise. We investigate how this registration-induced bias affects supervised MRI-to-CT and CBCT-to-CT synthesis on 1,784 paired patients covering five anatomical regions. Voxel-wise scores strongly depend on the consistency between the registration used to build the training targets and the one used for evaluation: models score best when both conventions match, showing that networks partly learn the geometric convention of the registration pipeline and that standard metrics reward it. Training on more anatomically consistent registrations reduces prediction variability and improves out-of-distribution robustness, and CT-only controls show that registration alone produces metric errors in the range of top challenge submissions. To mitigate the limits of voxel-wise supervision, we introduce a perceptual loss computed in the feature space of a pretrained Segment Anything encoder. Compared with MAE-only and VGG-based objectives, it improves downstream segmentation and yields sharper, more structurally coherent sCT. Perceptual and voxel-wise metrics disagree under imperfect alignment and agree when the evaluation geometry is reliable. These results identify registration-induced bias as a central confounder in supervised sCT generation and argue for complementing voxel-wise agreement with anatomy-oriented evaluation criteria.

Comment
23 pages, 4 figures, 19 tables

Closest papers

Nearest neighbours by meaning across the whole index.

A thorough review on Deep Learning approaches to 2D-to-3D Registration in Medical Imaging

eess.IV cs.CVcs.LGphysics.med-ph ·2026-11-12 ·Andrea Borghesi, Julia van Beurden, Maarten van Alphen, Michiel van den Brekel, Luc Karssemakers +4 more
similarity 0.70
Abstract · 51 pages, 4 tables, 8 figures

2D-to-3D image registration is a key component for several medical imaging purposes such as intraoperative guidance, enabling the alignment between preoperative 3D volumes and real-time 2D images. While conventional optimisation-based methods often struggle with non-convex objectives, sensitivity to initialisation, and high computational demands, deep learning (DL) has emerged as a promising alternative, offering improved alignment robustness and the potential for real-time performance. This review provides a comprehensive analysis of DL frameworks developed to address the challenges inherent in 2D-to-3D registration. We first outline how core concepts of DL are adapted to the registration problem. We then examine recent methodological advancements from multiple perspectives, including pipeline design, architectural innovations, and domain adaptation strategies. Particular attention is given to quantitative metrics, highlighting how performance is defined and measured across studies. Across the 41 included studies, we find that direct regression is the most common pipeline (23 studies, against 18 iterative ones), that hybrid CNN-attention architectures are gaining ground, and that research remains heavily concentrated on X-ray-to-CT registration. We conclude by identifying the absence of per-case uncertainty estimation and the strong neglect of temporal or sequential modelling as the two methodological gaps most consequential for clinical readiness, and discuss state-space models as a way to add temporal memory within intraoperative latency budgets. Further opportunities lie in more principled domain adaptation and in the integration of foundation models for representation learning.

0.19

Inference-Time Orthogonal Seeding Enables Geometry-Aligned 3D Organ Segmentation for Slice-Propagation Methods

cs.CV ·2026-08-12 ·Md Rakibul Haque, Tushar Kataria, Shireen Y. Elhabian
published similarity 0.70
Abstract · 8 Pages Accepted at MLMI Workshop MICCAI 2026

Dense voxel-level annotation remains a major bottleneck in 3D medical image segmentation. Single-slice propagation methods such as Sli2Vol reduce this burden by propagating one annotated seed slice through a volume using label-free registration. However, axial-only propagation accumulates errors with distance from the seed, especially in surface-distance metrics, because it ignores coronal and sagittal evidence and therefore underuses the 3D information available in CT/MRI volumes. To better leverage volumetric geometry, we study how key training and inference choices affect slice-propagation models, including single-axis versus multi-axis label-free registration, single-seed versus multi-seed propagation, and orthogonal seed configurations. Instead of propagating from a single axial seed, we use three orthogonal seeds---one axial, one coronal, and one sagittal---and fuse their propagated labels with a simple label-free rule. Our results show that the training paradigm has limited impact: an axially trained network applied to off-axis seeds captures nearly all the improvement, while explicit three-axis training adds little. Instead, performance is driven by inference-time seed geometry, especially orthogonality rather than the number of annotated slices, as a budget-matched three-axial control provides no benefit and can even degrade performance. On a multi-organ CT cohort, orthogonal seeding with the axial Sli2Vol backbone improves Dice by 21.9%, Normalized Surface Dice by 25.5%, and reduces Average Hausdorff Distance by 53.5% over the single-axis baseline.

0.54

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.68
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32

Registration is a Representation Problem: Solving Whole-Body PET/CT Registration

cs.CV cs.LG ·2026-10-13 ·Neel Dey, Adrian V. Dalca
publishedbenchmarkcode/data similarity 0.68
Abstract · Technical report. First place winning solution for the MICCAI Learn2Reg 2026 PSMAReg challenge. Code and volumetric visualizations are avail…

Raw image intensities are a poor surrogate for similarity across images in correspondence problems. Further, while auxiliary segmentation labels can provide semantic identification and improve matching, they can assign only coarse identities to fine-grained anatomy and often cover only a subset of structures, particularly in whole-body settings. We present an approach that instead establishes correspondence using complementary representations of anatomy and demonstrate its utility for longitudinal whole-body PET/CT registration in the Learn2Reg 2026 PSMAReg Challenge. We use our 3D foundation model, anatomix, to derive fine-grained, per-voxel semantic representations that are consistent across volumes and further employ off-the-shelf segmentation models to obtain coarse anatomical identities. Together, these representations drive a GPU-accelerated iterative registration solver (FireANTs) in a hybrid multistage framework: the first stage estimates alignment from dense multi-channel features, after which a second refines the deformation using both anatomix- and segmentation-based losses. Lastly, because registration should not introduce non-biological tumor volume changes across time, we develop lesion-specific, component-wise volume preservation schemes. Without any task-specific training, our system placed first on the PSMAReg Challenge leaderboard. Code and interactive visualizations are available at https://www.neeldey.com/reps-for-reg.

0.31

Recursive Uncertainty-Gated Image Registration for Learning-based Algorithms

eess.IV cs.CV ·2026-09-23 ·Clara Rodrigo González, Oscar Bates, Fu Siong Ng, Meng-Xing Tang
similarity 0.67
Abstract

Conventional image registration algorithms are robust to domain shifts and achieve low errors, but they are slow and computationally expensive. Deep-learning methods are efficient at inference-time, but face challenges in out-of-domain samples. We propose Recursive Uncertainty-Gated Image Registration (RUGI), an algorithm for iteratively refining deformation fields predicted by learning-based registration models. At each iteration, the registration model predicts an incremental deformation, and a gating map modulates the update. Refinements are hence concentrated in regions that remain difficult to register. We explore two gating strategies: a learned uncertainty-based approach and an image residual error approach. We evaluate RUGI on cardiac MRI and echocardiography datasets and show consistent improvements over single-step inference. Ablation experiments demonstrate that iterative refinement alone improves registration, but informative spatial gating provides a significant additional benefit. The error-gated variant of RUGI can also be applied directly to existing pretrained models; applied to VoxelMorph, TransMorph, and CycleMorph, it yields MSE reductions of 27-37% with no modification to the original training procedure. The improvements in registration performance are reflected in decreased errors in ejection fraction estimation relative to ground truths. These results demonstrate that spatially selective iterative refinement provides an effective strategy to improve registration accuracy at inference-time.

0.17

Real Pairs Are Not Enough: Physically Anchored Supervision for Volumetric CT Super-Resolution

cs.CV eess.IV ·2026-11-11 ·Haoran Liu, Zipei Yan, Mingzhe Liu, Jizhou Li, Guibin Zan
similarity 0.66
Abstract · 47 pages, 5 figures, including supplementary material

Volumetric CT super-resolution (SR) models are commonly trained on synthetic or physically acquired pairs of low-resolution (LR) and high-resolution (HR) volumes. However, synthetic pairs miss real acquisition effects, whereas registered physical pairs retain inter-scan noise, artifact, and microstructure differences---causing direct voxelwise regression, and even naive synthetic-real mixing, to oversmooth fine porous structures. We introduce the Physically-anchored Implicit Network (PIN) with Real-Pair Dual-Anchor learning, which decouples physical-pair supervision into two complementary roles. The HR anchor teaches fine structure from registered HR through pair-conditioned spectral replay, while the LR anchor constrains the prediction from acquired LR via affine-calibrated low-pass projection. Together with exact synthetic supervision in one shared volumetric implicit model, PIN learns from both physical scans without forcing the acquired-LR reconstruction to match registered HR voxel by voxel. Inference requires only acquired LR. Across 30 external baseline configurations on real CT, PIN achieves the lowest full-volume LPIPS, reduces average symmetric surface distance by 42.3-49.5% and bone-volume-fraction error by 52.2-53.4% relative to the three strongest baselines for each metric, and lowers the erased reference-pore volume fraction from 37.3-72.9% to 10.4%. Code, pretrained models, and evaluation scripts will be publicly available.

0.26

The Predictability Bias of Joint-Embedding Predictive Learning in Medical Imaging

eess.IV cs.CVcs.LG ·2026-10-09 ·Fabian Drexel, Bernhard Kainz, Jakob N. Kather, Daniel Rueckert, Lisa C. Adams +2 more
similarity 0.66
Abstract · 45 pages, 6 figures

Joint-embedding predictive architectures (JEPAs) learn by predicting teacher representations of masked regions from visible context. Point prediction summarizes the conditional target distribution and cannot reproduce variation that the context does not resolve. We call this constraint predictability bias. In computed tomography (CT), recurrent anatomy is predictable from context, whereas the sporadic, localized pathology that determines clinical interpretation often is not. We introduce TAP-JEPA, a ViT-B/3D trained on 113,611 CT volumes that is competitive with state-of-the-art encoders (COLIPRI, Merlin, VoxelFM) in scan-level classification. We then audit the learned predictive pathway by replaying the exact masking, teacher, and predictor computations used during training. Prediction lowers the mean Skill (prevalence-normalized average precision) from 0.388 to 0.271 for pathology, but only from 0.921 to 0.873 for anatomy. Along the teacher direction, separating pathology from matched control regions in the same organ, prediction moves pathology 34.7% toward the controls and controls 13.6% toward pathology, with larger shifts farther from visible context. Replacing visible matched-control representations increases surrounding-target prediction loss more than fully replacing pathology representations across four pathology categories. Downstream, removing all final-layer pathology tokens reduces the decision margin by at most 0.45% in four of seven scan-level probes. Together, these results show that contextual predictability is not a sufficient proxy for clinical relevance in medical representation learning. Training objectives should therefore retain diagnostic features regardless of their predictability from surrounding anatomy.

0.19

VoxForge: A Unified Foundation Model for Dense 3D Features Across MRI, CT and PET

cs.CV cs.LG ·2026-11-19 ·Rushil Anirudh, Jayaraman J. Thiagarajan
similarity 0.66
Abstract · 34 pages (8-page main paper, references, and 23-page supplementary material), 7 figures. Rushil Anirudh and Jayaraman J. Thiagarajan contrib…

A unified 3D medical foundation model promises reusable, frozen features that serve a wide variety of tasks such as segmentation, classification and registration on MRI, CT and PET as well as specialist models do. Generalist models still need separate backbones for localized and global tasks, specialist models are confined to a single modality, with the concern that spanning modalities under-emphasizes fine anatomy, and both typically rely on end-to-end fine-tuning to be competitive. We present VoxForge, a single encoder that integrates recent advances in 3D architecture, self-distillation and cross-modal curricula to learn transferable features from permissively licensed MRI and CT volumes. We evaluate it strictly frozen, the test a reusable foundation model must pass, against state-of-the-art generalist and specialist models on segmentation, classification and registration across MRI and CT, and on PET, which it never sees. VoxForge has the best or tied-best average rank in every task group, serves localized and global tasks across modalities at the level of state-of-the-art specialists, and is extremely label-efficient, matching top-performing models on TotalSegmentator CT with a tenth of the labels.

0.17