CS Paper Radar

Inference-Time Orthogonal Seeding Enables Geometry-Aligned 3D Organ Segmentation for Slice-Propagation Methods

Md Rakibul Haque, Tushar Kataria, Shireen Y. Elhabian

cs.CV ·submitted 2026-08-12 23:44 UTC · v1
published

Abstract

Dense voxel-level annotation remains a major bottleneck in 3D medical image segmentation. Single-slice propagation methods such as Sli2Vol reduce this burden by propagating one annotated seed slice through a volume using label-free registration. However, axial-only propagation accumulates errors with distance from the seed, especially in surface-distance metrics, because it ignores coronal and sagittal evidence and therefore underuses the 3D information available in CT/MRI volumes. To better leverage volumetric geometry, we study how key training and inference choices affect slice-propagation models, including single-axis versus multi-axis label-free registration, single-seed versus multi-seed propagation, and orthogonal seed configurations. Instead of propagating from a single axial seed, we use three orthogonal seeds---one axial, one coronal, and one sagittal---and fuse their propagated labels with a simple label-free rule. Our results show that the training paradigm has limited impact: an axially trained network applied to off-axis seeds captures nearly all the improvement, while explicit three-axis training adds little. Instead, performance is driven by inference-time seed geometry, especially orthogonality rather than the number of annotated slices, as a budget-matched three-axial control provides no benefit and can even degrade performance. On a multi-organ CT cohort, orthogonal seeding with the axial Sli2Vol backbone improves Dice by 21.9%, Normalized Surface Dice by 25.5%, and reduces Average Hausdorff Distance by 53.5% over the single-axis baseline.

Comment
8 Pages Accepted at MLMI Workshop MICCAI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

UniPro: Unified Multi-Mode Medical Image Segmentation from 2D Images to 3D Volumes via Propagation

cs.CV ·2026-10-03 ·Bangwei Guo, Yunhe Gao, Meng Ye, Yang Zhou, Difei Gu +3 more
similarity 0.73
Abstract

Medical image segmentation remains fragmented along two axes: segmentation paradigms and data dimensionality. Existing methods are typically developed separately for semantic, in-context, and interactive segmentation, and are further specialized to either native 2D images or 3D volumetric data. In clinical practice, however, segmentation workflows take many forms: a case may be initialized by semantic prediction, reference-guided segmentation, or user interaction. Regardless of how it begins, fine-grained refinement is naturally performed on 2D views; for volumetric scans, such 2D edits must propagate coherently to the rest of the volume. We present UniPro, a unified model that bridges segmentation paradigms and data dimensionality, using propagation to extend 2D segmentation to 3D volumes. Our key insight is that volumetric propagation and in-context segmentation share the same reference-conditioned prediction mechanism, differing only in whether the reference image-mask pairs come from other cases or from previously segmented neighboring slices. Building on this view, UniPro supports semantic, in-context, interactive, and propagation-based segmentation within a single slice-based framework, using class priors, reference exemplars, user clicks, and neighboring-slice predictions as mode-specific conditioning inputs. To improve propagation reliability, UniPro further incorporates bidirectional and 3D supervision to regularize slice-wise propagation beyond per-slice losses. Extensive experiments across diverse modalities and anatomies show that UniPro achieves strong performance across all segmentation settings, enabling annotation-efficient 3D segmentation from sparse 2D initialization and reducing slice-by-slice correction effort.

0.13

When Misalignment Becomes Supervision: Structured Label Noise in Supervised Synthetic CT Generation

cs.CV ·2026-09-24 ·Valentin Boussot, Cedric Hemon, Caroline Lafond, Jean-Claude Nunes, Jean-Louis Dillenseger
similarity 0.70
Abstract · 23 pages, 4 figures, 19 tables

Supervised synthetic CT (sCT) generation is commonly trained and evaluated as voxel-wise regression against registered reference CT images. In practice, MRI-CT and CBCT-CT pairs are aligned through registration procedures that leave residual misalignments. These residuals are not independent intensity noise but spatially coherent geometric discrepancies that act as structured label noise. We investigate how this registration-induced bias affects supervised MRI-to-CT and CBCT-to-CT synthesis on 1,784 paired patients covering five anatomical regions. Voxel-wise scores strongly depend on the consistency between the registration used to build the training targets and the one used for evaluation: models score best when both conventions match, showing that networks partly learn the geometric convention of the registration pipeline and that standard metrics reward it. Training on more anatomically consistent registrations reduces prediction variability and improves out-of-distribution robustness, and CT-only controls show that registration alone produces metric errors in the range of top challenge submissions. To mitigate the limits of voxel-wise supervision, we introduce a perceptual loss computed in the feature space of a pretrained Segment Anything encoder. Compared with MAE-only and VGG-based objectives, it improves downstream segmentation and yields sharper, more structurally coherent sCT. Perceptual and voxel-wise metrics disagree under imperfect alignment and agree when the evaluation geometry is reliable. These results identify registration-induced bias as a central confounder in supervised sCT generation and argue for complementing voxel-wise agreement with anatomy-oriented evaluation criteria.

0.27

Registration is a Representation Problem: Solving Whole-Body PET/CT Registration

cs.CV cs.LG ·2026-10-13 ·Neel Dey, Adrian V. Dalca
publishedbenchmarkcode/data similarity 0.69
Abstract · Technical report. First place winning solution for the MICCAI Learn2Reg 2026 PSMAReg challenge. Code and volumetric visualizations are avail…

Raw image intensities are a poor surrogate for similarity across images in correspondence problems. Further, while auxiliary segmentation labels can provide semantic identification and improve matching, they can assign only coarse identities to fine-grained anatomy and often cover only a subset of structures, particularly in whole-body settings. We present an approach that instead establishes correspondence using complementary representations of anatomy and demonstrate its utility for longitudinal whole-body PET/CT registration in the Learn2Reg 2026 PSMAReg Challenge. We use our 3D foundation model, anatomix, to derive fine-grained, per-voxel semantic representations that are consistent across volumes and further employ off-the-shelf segmentation models to obtain coarse anatomical identities. Together, these representations drive a GPU-accelerated iterative registration solver (FireANTs) in a hybrid multistage framework: the first stage estimates alignment from dense multi-channel features, after which a second refines the deformation using both anatomix- and segmentation-based losses. Lastly, because registration should not introduce non-biological tumor volume changes across time, we develop lesion-specific, component-wise volume preservation schemes. Without any task-specific training, our system placed first on the PSMAReg Challenge leaderboard. Code and interactive visualizations are available at https://www.neeldey.com/reps-for-reg.

0.31

Zero-Shot Brain MRI Inpainting with 2.5D Unconditional Flow Priors

cs.CV ·2026-10-06 ·Arnela Hadzic, Franz Thaler, Simon Johannes Joham, Martin Urschler
code/data similarity 0.69
Abstract

Generative inpainting of brain MRI volumes is essential for synthesizing healthy tissue in pathological regions, improving the accuracy and reliability of automated downstream brain analysis applications such as image registration, brain extraction, and segmentation. However, standard 3D approaches are computationally prohibitive, while efficient 2D slice-wise methods suffer from severe inter-slice discontinuities. Furthermore, traditional models rely on conditional training, requiring task-specific learning of masked inputs. We propose a zero-shot brain MRI inpainting framework utilizing 2.5D unconditional flow priors to capture spatial context along the superior-inferior axis without the overhead of full 3D convolutions. During training, our flow matching model learns the joint distribution of adjacent axial slice triplets, modeling the manifold of healthy brain anatomy while explicitly excluding pathological regions from the loss function. At inference, the model processes the input triplets autoregressively along the depth axis. We employ the Restora-Flow solver to constrain the unconditional prior using the input mask, achieving accurate zero-shot inpainting. Evaluations show our 2.5D strategy resolves the structural discontinuities of 2D baselines, synthesizing plausible healthy tissue while maintaining volumetric consistency across the axial, sagittal, and coronal planes. As a final step, we generate and average an ensemble of multiple stochastic reconstructions to form the final prediction. Quantitative results benchmarked on the official BraTS 2026 Inpainting Challenge validation set demonstrate the effectiveness of our proposed approach, yielding an SSIM of 0.816 $\pm$ 0.112, MSE of 0.007 $\pm$ 0.005, and PSNR of 22.923 $\pm$ 4.343. Code is available at https://github.com/imigraz/brats2026-inpainting.

0.16

Improving Cross-Site Whole-Heart Segmentation

eess.IV cs.CV ·2026-08-25 ·Tanish Mudaliar, Justin Li, Daniel Lin, Julianna Vo, Kaitao Liao +2 more
publishedcode/data similarity 0.68
Abstract · 12 pages, 2 figures. Accepted to the MICCAI 2026 for the CARE Whole Heart Segmentation Challenge proceedings

Whole-heart segmentation from CT and MRI is essential for quantitative cardiac image analysis, but remains challenging under multi-center and multi-modality distribution shift. In the CARE whole-heart segmentation task, models must generalize from limited labeled sites to unseen acquisition distributions, where variation in spacing, intensity, reconstruction texture, and anatomy can degrade out-of-distribution performance. We propose a modality-routed 3D cardiac segmentation pipeline that combines TotalSegmentator-initialized nnU-Netv2 models with site-characterized, label-preserving appearance augmentation. We first characterize the available sites using measurable image properties and use this analysis to motivate candidate data-space generalization routes. The final retained recipe applies Bias Field + Bezier appearance augmentation, combining smooth spatial intensity perturbation with nonlinear intensity remapping, followed by lightweight class-wise largest-connected-component cleanup. On the primary held-out-site validation splits, the final configuration improves CT mean Dice from 0.8350 to 0.9135 and MRI mean Dice from 0.7695 to 0.7830, while also reducing HD95. These results suggest that site-motivated appearance augmentation is a practical strategy for improving cross-site robustness in limited-data whole-heart segmentation. Our code can be found in https://github.com/Purdue-M2/Improving-Cross-Site-Whole-Heart-Segmentation

0.51

Steer the Sampling, Not the Kernel Grid: Geometry-Guided Sampling Operator for Volumetric Segmentation

cs.CV ·2026-08-26 ·Sizhe Wang, Himashi Peiris, Zhaolin Chen
top venue similarity 0.68
Abstract · Accepted at MICCAI 2026

Accurate 3D segmentation is central to quantitative lesion assessment and anatomy mapping for clinical planning and follow-up. Thin, elongated, and fine anatomical/pathological structures (e.g., vessels) are a particularly challenging case: a one-voxel boundary error can disconnect a branch and change clinically relevant topology. In encoder-decoder networks (e.g., U-Net), repeated downsampling and fixed-grid convolution blur or alias fine structures and weaken orientation cues, so early mistakes propagate across scales. We propose a geometry-guided local operator that steers where features are sampled, rather than deforming convolutional kernels, under a single formulation for both feature refinement (stride 1) and resolution reduction (stride > 1). At each voxel, it predicts a local orientation and bounded step sizes, samples symmetrically along these directions, and transforms paired samples into compact geometric and boundary cues with lightweight mixing; a cross-scale consensus aligns encoder and decoder features at skip connections to reduce geometric mismatch. Replacing all stride 1 and stride 2 operators in a 3D U-Net yields consistent improvements on BraTS, MSD Hepatic Vessel, and TDSC-ABUS, with notably better boundary metrics (e.g., BraTS Dice 86.1 to 88.9, HD95 7.1 to 6.2; TDSC-ABUS HD95 39.1 to 27.8) while reducing parameters from 2.3M to 0.8M. We further demonstrate that the operator can be integrated into other backbones (e.g., nnU-Net, Swin-UNETR, and MedNeXt) without changing their macro-architectures while providing consistent performance gains.

0.24

Confidence-Aware Teacher-Student Distillation for 3D Medical Segmentation

cs.CV ·2026-09-20 ·Georgios Triantafyllou, Dimitris K. Iakovidis
theory similarity 0.68
Abstract

Medical image segmentation models typically rely on large amounts of densely annotated volumetric data, limiting their scalability across tasks and imaging modalities. This work addresses the challenge of predicting entire 3D anatomical structures from extreme annotation sparsity. An annotation-efficient student-teacher framework is proposed for automatic 3D medical segmentation that requires only a set of point prompts on a single 2D slice per volume, as input. A foundation model serves as an offline teacher, utilizing the provided point prompts from the selected slice to full-volume pseudo-annotations alongside their corresponding spatial confidence scores prior to student training. To mitigate the error propagation of noisy pseudo-annotations, a task-specific 3D student network is trained using a confidence-aware optimization strategy. By leveraging the teacher's pre-computed confidence scores, this strategy explicitly excludes statically uncertain regions of the pseudo-annotations from the loss calculation, while simultaneously emphasizing regions with higher confidence. Evaluated on 3D cardiac MRI datasets, our framework outperforms state-of-the-art semi-supervised methods, improving segmentation performance by up to 43.6%. Furthermore, it drastically reduces the manual annotation burden to just a few positive point prompts per volume, while improving surface boundary precision by up to 14.7% over the teacher and successfully recovering up to 34.1% of the performance gap toward the fully supervised upper bound.

0.22

Vessel2Brain: Edge-Aware Multi-Scale Flow Matching for 3D Brain Image Generation from Vessel Masks

cs.CV ·2026-11-13 ·Zhi Chen, Tianyang Zhang, Theodoros N. Arvanitis, Le Zhang
similarity 0.67
Abstract

Generating realistic 3D brain MRI volumes from sparse anatomical priors is a highly ill-posed yet clinically valuable problem, with important applications in data augmentation, simulation, and downstream neuroimaging analysis. In this work, we investigate the challenging task of synthesising full 3D brain MRI volumes conditioned solely on vascular label maps. While vascular structures provide strong anatomical and topological cues, they occupy only a small fraction of the brain volume and offer no direct information about surrounding tissue appearance. To address this challenge, we propose Vessel2Brain, an edge-aware multi-scale conditional flow matching framework that explicitly incorporates vascular structure information into the generative process. Our approach formulates vessel-guided brain image synthesis as a conditional continuous flow, enabling stable training and flexible generation while preserving structural correspondence. A multi-scale flow matching strategy is introduced to jointly model global anatomical coherence and fine-grained local details, with auxiliary velocity predictions providing additional supervision across spatial resolutions. Furthermore, we design an edge-aware objective that emphasises vascular boundaries during training, encouraging anatomically faithful tissue synthesis around vessel structures. We evaluate Vessel2Brain on two public 3D brain MRI datasets with paired vascular annotations. Extensive quantitative and qualitative experiments demonstrate that our method consistently outperforms state-of-the-art generative models in terms of reconstruction accuracy, structural consistency, and distributional realism.

0.14