CS Paper Radar

Splat-based Metal Artifact Reduction in Cone-Beam CT via Polychromatic Modeling

Kiseok Choi, Inchul Kim, Jaemin Cho, Hyeongjun Cho, Min H. Kim

cs.CV cs.GR ·submitted 2026-08-13 12:25 UTC · v1
published

Abstract

Cone-beam computed tomography (CBCT) enables volumetric reconstruction from X-ray projections, but suffers from severe artifacts--especially beam hardening--when imaging materials with high attenuation such as metals. These artifacts arise from the polychromatic nature of X-rays and are not properly addressed by conventional monochromatic reconstruction algorithms. While recent neural representation-based methods offer improved reconstruction quality, they are computationally expensive and often impractical for deployment. We propose a novel physics-inspired, self-calibrating metal artifact reduction method that efficiently reconstructs 3D CBCT volumes while correcting beam hardening artifacts. Our method integrates a polychromatic X-ray projection model, material-dependent attenuation profiles, and system response modeling into a Gaussian Splatting framework. Unlike prior work, we eliminate the need for manual metal masks or strong prior assumptions, and we optimize both reconstruction parameters and X-ray spectral characteristics jointly during training. We further introduce a high-fidelity synthetic CBCT dataset generation pipeline validated on Monte-Carlo x-ray simulation toolbox and release new datasets with severe metal-induced artifacts to support the community. This is the first splat-based method for reducing beam hardening in CBCT. Extensive experiments on both synthetic and real-world datasets demonstrate that our method outperforms state-of-the-art approaches in artifact suppression and reconstruction accuracy.

Journal ref
Computer Graphics forum, Volume 45 (2026), Number 2
DOI
10.1111/cgf.70339

Closest papers

Nearest neighbours by meaning across the whole index.

SpectralCTGaussians: Projection-Domain Reconstruction and Basis Material Decomposition for Spectral CT using 3D Gaussian Splatting

cs.CV ·2026-08-29 ·Reinout Vos, Saptarshi Neil Sinha, Michael Weinmann
similarity 0.69
Abstract

Spectral computed tomography (CT) extends conventional CT by measuring attenuation across multiple energy channels, allowing improved modeling of physical X-ray interactions and energy-dependent material behavior and leading to richer scene understanding. We present a novel method for spectral CT reconstruction and basis material decomposition using 3D Gaussian Splatting by adding per-Gaussian basis material fractions to the set of learnable parameters, which together with a set of energy-dependent basis functions define the attenuation across the full spectral range. The basis functions represent various physical attenuation models such as photoelectric absorption and Compton scattering, and are jointly optimized across all energy channels through a differentiable polychromatic forward model, with material decomposition performed via mean-shift clustering of the resulting coefficients. We evaluate our method on a baseline real-world dataset as well as a synthetic dataset that we introduce, comparing against traditional reconstruction algorithms and state-of-the-art learning-based CT reconstruction methods. Our approach outperforms all traditional baselines in novel view synthesis and achieves the best PSNR among all compared methods for spectral CT volume reconstruction, while describing all energy channels with a single shared representation that requires a number of Gaussians comparable to single-channel Gaussian splatting-based CT reconstruction approaches. For basis material decomposition, no traditional or learning-based baseline offers one-step decomposition with direct RGB material segmentation, and our method additionally recovers the photoelectric basis with higher PSNR than traditional pipelines.

0.25

LINGO: Latent Initialization and Gradient Optimization for Sparse-view X-ray Novel View Synthesis and CT Reconstruction with 3D Gaussian Splatting

cs.CV cs.GR ·2026-09-19 ·Lifeng Xing, Dequan Jin, Kunpeng Bu, Peigeng He, Shihui Ying
similarity 0.68
Abstract

In novel view synthesis and Computed Tomography (CT) reconstruction with sparse-view X-ray imaging, insufficient angular coverage leads to structural ambiguity and accumulated noise. Integrating 3D Gaussian Splatting (3DGS) with X-ray absorption physics can achieve promising results, but it suffers from noisy initialization, positional insensitivity, and weak gradients in low-density regions. In this paper, we propose a unified Latent Initialization and Gradient Optimization (LINGO) framework to address these issues. LINGO combines latent mask-space initialization with dynamic gradient optimization to improve point cloud structural completeness while accelerating training. It constructs voxel-level 3D filters from X-ray masks to robustly suppress background noise and provide reliable geometric priors. By employing an adaptive voxel scaling strategy and dynamically scaling loss, LINGO can adjust spatial resolution and explicitly amplify gradients in low-density structures. To evaluate the quality of initialization, we introduce the Initialization Point Cloud Structural Deviation (IPSD) metric. Experiments on the X3D dataset indicate that for the novel view synthesis task, LINGO improves the Peak Signal-to-Noise Ratio (PSNR) and Structural Similarity Index (SSIM) by an average of 0.72 and 0.0039, respectively, over baselines under identical sparse-view settings, achieving comparable reconstruction quality within 5k steps to state-of-the-art models typically trained with 30k iterations. For the CT reconstruction task, LINGO also demonstrates consistent improvements, with average PSNR and SSIM gains of 0.36 and 0.0134. These results highlight LINGO's effectiveness in both accelerating training and enhancing reconstruction quality across different sparse-view imaging scenarios.

0.37

VoxelSynth3D: Interpretable Volumetric Image-Domain Metal Artifact Reduction with a Paired Synthetic CLINIC Benchmark

cs.CV ·2026-10-01 ·Amritesh Banerjee, Abdul Basit, Renil Renji Joseph, Nouhaila Innan, Muhammad Shafique
publishedbenchmark similarity 0.68
Abstract · 7 pages, 7 figures. Accepted for publication at BHI 2026

Metal artifacts in postoperative musculoskeletal CT obscure bone-implant and adjacent soft-tissue interfaces. Many metal artifact reduction (MAR) methods require unavailable raw projections or learned models that may shift across scanners and implants. We present VoxelSynth3D, a training-free 3D image-domain framework for reconstructed CT. The framework combines support masking, normalized tissue synthesis, deviation gating, and restricted edge refinement. Detected implant voxels are preserved in the output, while correction targets metal-induced artifacts in the surrounding tissue. We also construct Synthetic CLINIC-Metal, a controlled paired synthetic evaluation resource, from no-metal CTPelvic1K volumes with clean targets, metal/artifact masks, fixed seeds, and patient-level splits; 75 unpaired real metal cases receive qualitative/no-reference evaluation only. The operating point was fixed in a near-flat validation basin. With exact-mask oracle localization, all methods share a metal-excluded tissue ROI. On 40 held-out cases, VoxelSynth3D reduced RMSE from 801.48 to 786.18 HU (paired gain 15.30 HU, 95% CI 11.68-19.23), improving every case and exceeding the evaluated 3D Gaussian smoother by 13.58 HU. Clean-edge agreement decreased next to metal but exceeded input beyond 5 mm. Thus, VoxelSynth3D provides case-consistent within-distribution tissue-error reduction with a localized structural tradeoff. Spacing-aware sensitivity retained aggregate broad-region improvement and identified near-metal calibration as a target.

0.28

Toward a Foundation Plug-and-Play Prior for Computed Tomography Reconstruction via a Multimodal Diffusion Model

cs.CV ·2026-08-24 ·Haley Duba-Sullivan, Patxi Fernandez-Zelaia, Obaidullah Rahman, Amirkoushyar Ziabari
published similarity 0.68
Abstract · To appear in SC26 Workshops proceedings

Computed tomography (CT) throughput is limited by scan time, which grows with both the number of projections acquired and the detector integration time for each projection. Reconstructing high-quality volumes from sparse-view or low-dose measurements therefore depends on using an informative prior, typically a neural network trained for one specific scan setting and retrained whenever the modality, geometry, or material changes. We investigate whether a single diffusion model trained across several imaging domains can instead serve as a reusable prior for heterogeneous CT reconstruction problems. We evaluate the proposed method using the same diffusion visual transformer model and normalized denoising strength on three datasets that differ in modality, beam geometry, material, and degradation type, spanning additively manufactured metal parts and concrete microstructure imaged with cone-bean X-ray CT and parallel-beam neutron CT respectively. The proposed method improves upon analytic reconstructions in all three cases, demonstrating transferability across the evaluated problems and providing a step toward a reusable foundation prior for heterogeneous CT reconstruction.

0.25

OX-NeRF: 3D X-ray Tomography Reconstruction from Sparse Views Using Implicit Neural Representation

cs.CV ·2026-10-08 ·Thomas Welsch, Min-Hsin Tu, David J. Chapman, Daniel E. Eakins
similarity 0.66
Abstract

NeRF and Gaussian splatting methods have been successfully applied on X-ray scenes where the views are too sparse for 3D reconstruction via classical methods. Ultra-sparse scenes with 10 or fewer views such as those with high-rate or low-dose acquisition still, however, present a significant challenge. To address this problem we present a new framework, Optimised X-ray Neural Radiance Fields (OX-NeRF), that combines cross-scene feature learning with scene-specific optimisation to reconstruct sets of related scenes. OX-NeRF employs a convolutional neural network (CNN) to identify cross-scene features while maintaining scene-specific multi-resolution hash grids of spatial features. The paired representations are fused and passed to a multilayer perceptron (MLP); the CNN, hash grids and MLP are then jointly optimised end-to-end. Benchmarking on parallel-beam and cone-beam X-ray datasets shows OX-NeRF provides significantly higher reconstruction accuracy on ultra-sparse scenes compared to existing radiance field methods.

0.15

RePrior: Measurement-Reconciled Prior Correction for Sparse-View CBCT Reconstruction

eess.IV cs.CV ·2026-10-08 ·Mengrui Yin, Tianxingjian Ding, Wufan Zhao, Ziyang Yan, Yu Tian
similarity 0.65
Abstract

Sparse-view cone-beam computed tomography (CBCT) is severely under-constrained by limited X-ray projections. Learned reconstruction can provide complementary anatomical information, but using it as a prior in patient-specific Gaussian reconstruction introduces two challenges. First, the discrepancy between the learned prior and current reconstruction is spatially non-uniform: some local differences contain useful missing 3D information, whereas others reflect prior bias. Second, even a volumetrically beneficial correction can conflict with the observed X-ray measurements. Since X-ray measurements are line integrals, spatially separated corrections may affect overlapping rays, with their signed projection responses reinforcing or partially canceling in the measurement residual, so their feasibility cannot always be assessed independently. In this paper, we introduce RePrior, a multi-stage progressive prior-correction framework that addresses correction actionability, measurement feasibility, and representation expressivity. Selective Correction Proposal (SCP) first identifies actionable signed local corrections from prior--reconstruction discrepancies. Measurement-Constrained Reconciliation (MCR) then jointly enforces their consistency with patient-specific X-ray measurements, while Hybrid Residual Enhancement (HRE) recovers additional correction capacity through complementary voxel- and Gaussian-domain degrees of freedom around the reconciled anchor. RePrior requires neither test-time ground truth nor case-specific network fine-tuning. RePrior gains approximately 2.6~dB in 3D PSNR over R$^2$-Gaussian across LUNA16, PANORAMA, and PENGWIN. Beyond prior-assisted reconstruction, it delivers additional gains in volumetric quality and observed-view projection fidelity, with consistent gains in held-out-view fidelity in the backbone-matched evaluation.

0.20

Task-driven sparse-view planar X-ray computed tomography for axial metrology

eess.IV cs.CV ·2026-11-01 ·Yibin Tian, Shuming Yang, Wolfgang Heidrich
similarity 0.65
Abstract

Computational imaging can reduce the acquisition burden when the system is designed around task-relevant information rather than complete image recovery. We investigate this framework for sparse-view planar X-ray tomography (XCT) of layered objects, using measurement of the axial termination gap (ATG) of back-drilled printed-circuit-board (PCB) vias as a representative task. Instead of using 3D reconstruction, the proposed method estimates ATG directly from polychromatic projection data through a physics-based sensitivity model. A gated hierarchical estimator first fits ATG together with radiometric perturbations and selectively introduces global geometry and specimen-warp models only when a reduced chi-squared adequacy test and Bayesian information criterion justify the added degrees of freedom. The same low-dimensional perturbation model is incorporated into marginalized Fisher-information analyses, yielding task-specific conditional and calibration-aware Cram'er-Rao bounds. Numerical experiments show that, under a fixed total photon budget, task-driven metrology changes little over 12-64 views, while reconstruction-driven metrology is strongly view-dependent with much larger errors. The direct estimator also follows the expected photon-limited scaling. These results demonstrate a computational sensing strategy in which XCT acquisition, physical modeling, and inference are evaluated according to the quantitative information required by the task rather than for general-purpose volumetric image fidelity.

0.25

Shape-guided Gaussian Splatting for Sparse-View X-ray 3D Reconstruction

cs.CV ·2026-09-09 ·Pranav Poudel, Florence Dell'Aniello Picard, Nairouz Shehata, Frédéric Lavoie, Herve Lombaert
publishedcode/data similarity 0.64
Abstract · Accepted at: Off-Grid: 1st Workshop on Continuous Representations and Grid-Free Methods in Medical Imaging, MICCAI 2026

Sparse-view X-ray 3D reconstruction is essential for reducing radiation exposure, but recovering a density field from a handful of X-ray projections is severely ill-posed. Recently, 3D Gaussian Splatting has achieved state-of-the-art performance in sparse-view reconstruction by representing the volume using explicit, optimized primitives, but it requires dozens of projected views. With fewer views, reconstruction quality degrades severely since the explicit primitives are optimized freely without any anatomical information. Anatomical structures, in contrast, share similar geometry and density across a population. Their variations are bounded within a limited range that statistical shape models can capture. This paper proposes a shape-guided Gaussian splatting framework for sparse-view X-ray 3D reconstructions. Our contribution lies in driving Gaussian positions toward anatomically valid configurations, alongside atlas-based density regularization. Our method ensures anatomically consistent reconstruction and improves PSNR by 2.83 dB over a state-of-the-art Gaussian splatting baseline with as few as 5 views. Code Available: https://github.com/polyshape-lab/ShapeGuidedGaussian

0.46