CS Paper Radar

Task-driven sparse-view planar X-ray computed tomography for axial metrology

Yibin Tian, Shuming Yang, Wolfgang Heidrich

eess.IV cs.CV ·submitted 2026-11-01 04:09 UTC · v1

Abstract

Computational imaging can reduce the acquisition burden when the system is designed around task-relevant information rather than complete image recovery. We investigate this framework for sparse-view planar X-ray tomography (XCT) of layered objects, using measurement of the axial termination gap (ATG) of back-drilled printed-circuit-board (PCB) vias as a representative task. Instead of using 3D reconstruction, the proposed method estimates ATG directly from polychromatic projection data through a physics-based sensitivity model. A gated hierarchical estimator first fits ATG together with radiometric perturbations and selectively introduces global geometry and specimen-warp models only when a reduced chi-squared adequacy test and Bayesian information criterion justify the added degrees of freedom. The same low-dimensional perturbation model is incorporated into marginalized Fisher-information analyses, yielding task-specific conditional and calibration-aware Cram'er-Rao bounds. Numerical experiments show that, under a fixed total photon budget, task-driven metrology changes little over 12-64 views, while reconstruction-driven metrology is strongly view-dependent with much larger errors. The direct estimator also follows the expected photon-limited scaling. These results demonstrate a computational sensing strategy in which XCT acquisition, physical modeling, and inference are evaluated according to the quantitative information required by the task rather than for general-purpose volumetric image fidelity.

Closest papers

Nearest neighbours by meaning across the whole index.

LINGO: Latent Initialization and Gradient Optimization for Sparse-view X-ray Novel View Synthesis and CT Reconstruction with 3D Gaussian Splatting

cs.CV cs.GR ·2026-09-19 ·Lifeng Xing, Dequan Jin, Kunpeng Bu, Peigeng He, Shihui Ying
similarity 0.65
Abstract

In novel view synthesis and Computed Tomography (CT) reconstruction with sparse-view X-ray imaging, insufficient angular coverage leads to structural ambiguity and accumulated noise. Integrating 3D Gaussian Splatting (3DGS) with X-ray absorption physics can achieve promising results, but it suffers from noisy initialization, positional insensitivity, and weak gradients in low-density regions. In this paper, we propose a unified Latent Initialization and Gradient Optimization (LINGO) framework to address these issues. LINGO combines latent mask-space initialization with dynamic gradient optimization to improve point cloud structural completeness while accelerating training. It constructs voxel-level 3D filters from X-ray masks to robustly suppress background noise and provide reliable geometric priors. By employing an adaptive voxel scaling strategy and dynamically scaling loss, LINGO can adjust spatial resolution and explicitly amplify gradients in low-density structures. To evaluate the quality of initialization, we introduce the Initialization Point Cloud Structural Deviation (IPSD) metric. Experiments on the X3D dataset indicate that for the novel view synthesis task, LINGO improves the Peak Signal-to-Noise Ratio (PSNR) and Structural Similarity Index (SSIM) by an average of 0.72 and 0.0039, respectively, over baselines under identical sparse-view settings, achieving comparable reconstruction quality within 5k steps to state-of-the-art models typically trained with 30k iterations. For the CT reconstruction task, LINGO also demonstrates consistent improvements, with average PSNR and SSIM gains of 0.36 and 0.0134. These results highlight LINGO's effectiveness in both accelerating training and enhancing reconstruction quality across different sparse-view imaging scenarios.

0.37

Splat-based Metal Artifact Reduction in Cone-Beam CT via Polychromatic Modeling

cs.CV cs.GR ·2026-08-13 ·Kiseok Choi, Inchul Kim, Jaemin Cho, Hyeongjun Cho, Min H. Kim
published similarity 0.65
Abstract

Cone-beam computed tomography (CBCT) enables volumetric reconstruction from X-ray projections, but suffers from severe artifacts--especially beam hardening--when imaging materials with high attenuation such as metals. These artifacts arise from the polychromatic nature of X-rays and are not properly addressed by conventional monochromatic reconstruction algorithms. While recent neural representation-based methods offer improved reconstruction quality, they are computationally expensive and often impractical for deployment. We propose a novel physics-inspired, self-calibrating metal artifact reduction method that efficiently reconstructs 3D CBCT volumes while correcting beam hardening artifacts. Our method integrates a polychromatic X-ray projection model, material-dependent attenuation profiles, and system response modeling into a Gaussian Splatting framework. Unlike prior work, we eliminate the need for manual metal masks or strong prior assumptions, and we optimize both reconstruction parameters and X-ray spectral characteristics jointly during training. We further introduce a high-fidelity synthetic CBCT dataset generation pipeline validated on Monte-Carlo x-ray simulation toolbox and release new datasets with severe metal-induced artifacts to support the community. This is the first splat-based method for reducing beam hardening in CBCT. Extensive experiments on both synthetic and real-world datasets demonstrate that our method outperforms state-of-the-art approaches in artifact suppression and reconstruction accuracy.

0.54

RePrior: Measurement-Reconciled Prior Correction for Sparse-View CBCT Reconstruction

eess.IV cs.CV ·2026-10-08 ·Mengrui Yin, Tianxingjian Ding, Wufan Zhao, Ziyang Yan, Yu Tian
similarity 0.65
Abstract

Sparse-view cone-beam computed tomography (CBCT) is severely under-constrained by limited X-ray projections. Learned reconstruction can provide complementary anatomical information, but using it as a prior in patient-specific Gaussian reconstruction introduces two challenges. First, the discrepancy between the learned prior and current reconstruction is spatially non-uniform: some local differences contain useful missing 3D information, whereas others reflect prior bias. Second, even a volumetrically beneficial correction can conflict with the observed X-ray measurements. Since X-ray measurements are line integrals, spatially separated corrections may affect overlapping rays, with their signed projection responses reinforcing or partially canceling in the measurement residual, so their feasibility cannot always be assessed independently. In this paper, we introduce RePrior, a multi-stage progressive prior-correction framework that addresses correction actionability, measurement feasibility, and representation expressivity. Selective Correction Proposal (SCP) first identifies actionable signed local corrections from prior--reconstruction discrepancies. Measurement-Constrained Reconciliation (MCR) then jointly enforces their consistency with patient-specific X-ray measurements, while Hybrid Residual Enhancement (HRE) recovers additional correction capacity through complementary voxel- and Gaussian-domain degrees of freedom around the reconciled anchor. RePrior requires neither test-time ground truth nor case-specific network fine-tuning. RePrior gains approximately 2.6~dB in 3D PSNR over R$^2$-Gaussian across LUNA16, PANORAMA, and PENGWIN. Beyond prior-assisted reconstruction, it delivers additional gains in volumetric quality and observed-view projection fidelity, with consistent gains in held-out-view fidelity in the backbone-matched evaluation.

0.20

Extremely Sparse-View Computed Tomography from 2D Projections via Pose-Aware Diffusion Priors

cs.CV cs.AI ·2026-10-28 ·Linrui Dai, Jinxiu Liang, Chu Zhou, Mae Yamaguchi, Ryuya Takahashi +1 more
published similarity 0.64
Abstract · NeurIPS 2026 poster

Extremely sparse-view computed tomography (xSV-CT) is critical when scanning time, motion, or radiation tolerance limits each scan to only a few projections. In many such scenarios, the same acquisition limits also constrain dataset construction, making pre-reconstructed 3D volumes from dense scans unavailable. This exposes a gap in current sparse-view approaches: Optimization-based methods, which use the sparse measurements directly but lack data-driven priors to suppress artifacts, and learning-based methods, which use strong priors but usually require densely scanned training volumes acquired outside the xSV-CT regime. We study this train-sparse / infer-sparse setting by learning a pose-aware diffusion prior from one 2D projection per training sample, then guiding diffusion sampling with measured-view fidelity, shared-volume reprojection, and projection-physics consistency for tomographic reconstruction. On two public CT datasets across 1-, 4-, and 8-view settings, the proposed method achieves the best novel-view synthesis scores and best or competitive reconstruction quality compared with baselines that use dense-volume supervision.

0.26

View optimization in Computed Tomography

eess.IV ·2026-11-02 ·Seemeen Karimi, Christopher McGuire
published similarity 0.64
Abstract · All figures are in the PDF. presented at a conference, conference proceedings pending

Many emerging CT imaging applications must operate with data from sparse projection angles, on the order of 10 views, such as first responder scenarios, dynamic imaging of detonation events, and flash imaging of materials under extreme conditions in high energy-density science. Few-view imaging is a data undersampling problem, that degrades tomographic reconstructions with streaks, shadows, and other aliasing artifacts, due to ill-conditioning. In few- view CT, the specific set of projection angles can strongly impact reconstruction quality, and the optimal angles depend on the object being scanned. Despite a surge of recent research, there is much to explore in this problem. We present an object-aware performance prediction framework for few-view projection datasets based on a matrix decomposition of the discretized forward model augmented with expected object gradient information. The method yields a quantitative score for a candidate set of view angles that can underpin a view selection recommendation algorithm. A key feature is that it can be applied at multiple stages of acquisition: a priori, before any radiographs are taken, or adaptively, after some radiographs are collected, to determine the next best view. We demonstrate the approach using simulated CT data with 5 view and 15 view configurations. Preliminary results are encouraging; images reconstructed using a standard statistical algorithm show that reconstruction accuracy agrees with our performance score. Reconstruction accuracy was evaluated against a known ground truth using an information theoretic score. Continued testing with complex objects and multiple geometries is necessary.

0.14

Learning Where and What to Lift for Bi-planar X-ray-to-CT Reconstruction

cs.CV cs.AI ·2026-08-18 ·Yifei Wu, Yicheng Wu, Qiang Ma, Qi Chen, Renyang Gu +3 more
similarity 0.63
Abstract

X-ray imaging can be approximately modeled as the projection of an underlying volumetric attenuation field, with each measurement recording the accumulated attenuation along a corresponding ray path. Reconstructing a CT volume from only a few X-ray views is therefore severely ill-posed, as the projections collapse depth information and leave 3D locations of anatomical regions and their corresponding intensity distributions highly entangled and ambiguous. We observe that once the spatial organization of anatomical regions is established, estimating their CT intensities becomes substantially more tractable. Motivated by this, we propose LiftXR, an interleaved, geometry-guided framework that explicitly incorporates spatial layout recovery into CT reconstruction. Specifically, a layout lifter first generates a 3D anatomical layout from bi-planar X-rays, providing spatial guidance for an intensity renderer to reconstruct a CT volume. An anatomical parser then performs volumetric perception on the reconstruction, exploiting its spatially resolved boundary and intensity cues to recover a refined anatomical layout. This transition from projection-conditioned layout generation to reconstruction-conditioned anatomical perception allows the parsed layout to provide feedback for region-specific intensity calibration. Extensive experiments on two public datasets demonstrate that LiftXR consistently outperforms recent X-ray-to-CT reconstruction methods, establishing a new state of the art. Moreover, the reconstructed CT achieves superior performance in external downstream segmentation, indicating improved anatomical fidelity. Code will be released.

0.22

Shape-guided Gaussian Splatting for Sparse-View X-ray 3D Reconstruction

cs.CV ·2026-09-09 ·Pranav Poudel, Florence Dell'Aniello Picard, Nairouz Shehata, Frédéric Lavoie, Herve Lombaert
publishedcode/data similarity 0.63
Abstract · Accepted at: Off-Grid: 1st Workshop on Continuous Representations and Grid-Free Methods in Medical Imaging, MICCAI 2026

Sparse-view X-ray 3D reconstruction is essential for reducing radiation exposure, but recovering a density field from a handful of X-ray projections is severely ill-posed. Recently, 3D Gaussian Splatting has achieved state-of-the-art performance in sparse-view reconstruction by representing the volume using explicit, optimized primitives, but it requires dozens of projected views. With fewer views, reconstruction quality degrades severely since the explicit primitives are optimized freely without any anatomical information. Anatomical structures, in contrast, share similar geometry and density across a population. Their variations are bounded within a limited range that statistical shape models can capture. This paper proposes a shape-guided Gaussian splatting framework for sparse-view X-ray 3D reconstructions. Our contribution lies in driving Gaussian positions toward anatomically valid configurations, alongside atlas-based density regularization. Our method ensures anatomically consistent reconstruction and improves PSNR by 2.83 dB over a state-of-the-art Gaussian splatting baseline with as few as 5 views. Code Available: https://github.com/polyshape-lab/ShapeGuidedGaussian

0.46

SpectralCTGaussians: Projection-Domain Reconstruction and Basis Material Decomposition for Spectral CT using 3D Gaussian Splatting

cs.CV ·2026-08-29 ·Reinout Vos, Saptarshi Neil Sinha, Michael Weinmann
similarity 0.62
Abstract

Spectral computed tomography (CT) extends conventional CT by measuring attenuation across multiple energy channels, allowing improved modeling of physical X-ray interactions and energy-dependent material behavior and leading to richer scene understanding. We present a novel method for spectral CT reconstruction and basis material decomposition using 3D Gaussian Splatting by adding per-Gaussian basis material fractions to the set of learnable parameters, which together with a set of energy-dependent basis functions define the attenuation across the full spectral range. The basis functions represent various physical attenuation models such as photoelectric absorption and Compton scattering, and are jointly optimized across all energy channels through a differentiable polychromatic forward model, with material decomposition performed via mean-shift clustering of the resulting coefficients. We evaluate our method on a baseline real-world dataset as well as a synthetic dataset that we introduce, comparing against traditional reconstruction algorithms and state-of-the-art learning-based CT reconstruction methods. Our approach outperforms all traditional baselines in novel view synthesis and achieves the best PSNR among all compared methods for spectral CT volume reconstruction, while describing all energy channels with a single shared representation that requires a number of Gaussians comparable to single-channel Gaussian splatting-based CT reconstruction approaches. For basis material decomposition, no traditional or learning-based baseline offers one-step decomposition with direct RGB material segmentation, and our method additionally recovers the photoelectric basis with higher PSNR than traditional pipelines.

0.25