Abstract

Spectral computed tomography (CT) extends conventional CT by measuring attenuation across multiple energy channels, allowing improved modeling of physical X-ray interactions and energy-dependent material behavior and leading to richer scene understanding. We present a novel method for spectral CT reconstruction and basis material decomposition using 3D Gaussian Splatting by adding per-Gaussian basis material fractions to the set of learnable parameters, which together with a set of energy-dependent basis functions define the attenuation across the full spectral range. The basis functions represent various physical attenuation models such as photoelectric absorption and Compton scattering, and are jointly optimized across all energy channels through a differentiable polychromatic forward model, with material decomposition performed via mean-shift clustering of the resulting coefficients. We evaluate our method on a baseline real-world dataset as well as a synthetic dataset that we introduce, comparing against traditional reconstruction algorithms and state-of-the-art learning-based CT reconstruction methods. Our approach outperforms all traditional baselines in novel view synthesis and achieves the best PSNR among all compared methods for spectral CT volume reconstruction, while describing all energy channels with a single shared representation that requires a number of Gaussians comparable to single-channel Gaussian splatting-based CT reconstruction approaches. For basis material decomposition, no traditional or learning-based baseline offers one-step decomposition with direct RGB material segmentation, and our method additionally recovers the photoelectric basis with higher PSNR than traditional pipelines.

Closest papers

Nearest neighbours by meaning across the whole index.

Shared-Structure 4D Spectral Gaussian Representation for Sparse-View Spectral CT Reconstruction

cs.CV ·2026-08-17 ·Jiancheng Fang, Shaoyu Wang, Wenjun Xia, Yang Chen, Qiegen Liu
similarity 0.74
Abstract

Sparse-view spectral computed tomography (CT) reconstructs energy-resolved attenuation volumes from limited projection views, requiring simultaneous handling of angular undersampling and spectral coupling. We propose a SharedStructure 4D Spectral Gaussian Representation (4D-SG) that learns shared Gaussian geometry from full spectrum structural projections and uses a Gaussian-wise Spectral Density Curve Network (GSC-Net) to predict Gaussian raw density transformations. This factorization separates shared spatial structure from spectral attenuation variation, avoids independent channel geometry optimization, and establishes a continuous 4D-SG representation from discrete spectral measurements for unobserved spectral channel queries. Experiments on six synthesized, simulated projection, and real projection datasets with 50 views demonstrate the best average performance. Compared with the strongest Gaussian baseline, 4D-SG improves PSNR from 35.56 dB to 36.61 dB, increases SSIM from 0.909 to 0.914, and reduces LPIPS from 0.208 to 0.194, demonstrating its effectiveness for sparse-view spectral CT reconstruction.

0.15

Gaussian Material Fields for Volumetric Multi-Energy CT Decomposition

cs.CV ·2026-10-07 ·Jian Lin, Jiancheng Fang, Hongming Shan, Shaoyu Wang, Yang Chen +1 more
similarity 0.74
Abstract · 13 pages, 12 figures

Volumetric material decomposition in multi-energy computed tomography requires a representation that organizes multiple three-dimensional material fields in a common spatial domain while retaining differences in composition and local structure. We observe that spatial primitives can be shared across materials without tying their coefficients, but their local capacity must respond to material-specific reconstruction needs. We introduce Gaussian material fields, which represent multiple material distributions with shared anisotropic 3D Gaussian primitives and independent nonnegative material coefficients. The shared geometry defines a continuous spatial basis, while the coefficients determine each primitive's contribution to the individual material fields. To reconstruct this representation from multi-energy projections, a differentiable spectral forward model combines Gaussian material path integrals with a calibrated basis matrix, enabling joint optimization of spatial geometry and material composition. Material-aware adaptive density control retains material-specific refinement evidence before aggregation and adjusts local representation capacity to accommodate both spatially extensive components and sparse details. Experiments use synthesized multi-energy projections generated from pseudo-reference material maps constructed by conventional methods from publicly available CT data. Across 15 cases, our approach improves average PSNR by 4.03 dB and SSIM by 4.96% over the strongest baseline, while reducing NRMSE by 33.45%. Material-wise comparisons and component ablations support improved recovery of localized structures, while runtime and memory measurements show favorable computational scaling. These results establish Gaussian material fields as an explicit, adaptive representation for volumetric multi-material reconstruction.

0.27

Splat-based Metal Artifact Reduction in Cone-Beam CT via Polychromatic Modeling

cs.CV cs.GR ·2026-08-13 ·Kiseok Choi, Inchul Kim, Jaemin Cho, Hyeongjun Cho, Min H. Kim
published similarity 0.69
Abstract

Cone-beam computed tomography (CBCT) enables volumetric reconstruction from X-ray projections, but suffers from severe artifacts--especially beam hardening--when imaging materials with high attenuation such as metals. These artifacts arise from the polychromatic nature of X-rays and are not properly addressed by conventional monochromatic reconstruction algorithms. While recent neural representation-based methods offer improved reconstruction quality, they are computationally expensive and often impractical for deployment. We propose a novel physics-inspired, self-calibrating metal artifact reduction method that efficiently reconstructs 3D CBCT volumes while correcting beam hardening artifacts. Our method integrates a polychromatic X-ray projection model, material-dependent attenuation profiles, and system response modeling into a Gaussian Splatting framework. Unlike prior work, we eliminate the need for manual metal masks or strong prior assumptions, and we optimize both reconstruction parameters and X-ray spectral characteristics jointly during training. We further introduce a high-fidelity synthetic CBCT dataset generation pipeline validated on Monte-Carlo x-ray simulation toolbox and release new datasets with severe metal-induced artifacts to support the community. This is the first splat-based method for reducing beam hardening in CBCT. Extensive experiments on both synthetic and real-world datasets demonstrate that our method outperforms state-of-the-art approaches in artifact suppression and reconstruction accuracy.

0.54

LINGO: Latent Initialization and Gradient Optimization for Sparse-view X-ray Novel View Synthesis and CT Reconstruction with 3D Gaussian Splatting

cs.CV cs.GR ·2026-09-19 ·Lifeng Xing, Dequan Jin, Kunpeng Bu, Peigeng He, Shihui Ying
similarity 0.68
Abstract

In novel view synthesis and Computed Tomography (CT) reconstruction with sparse-view X-ray imaging, insufficient angular coverage leads to structural ambiguity and accumulated noise. Integrating 3D Gaussian Splatting (3DGS) with X-ray absorption physics can achieve promising results, but it suffers from noisy initialization, positional insensitivity, and weak gradients in low-density regions. In this paper, we propose a unified Latent Initialization and Gradient Optimization (LINGO) framework to address these issues. LINGO combines latent mask-space initialization with dynamic gradient optimization to improve point cloud structural completeness while accelerating training. It constructs voxel-level 3D filters from X-ray masks to robustly suppress background noise and provide reliable geometric priors. By employing an adaptive voxel scaling strategy and dynamically scaling loss, LINGO can adjust spatial resolution and explicitly amplify gradients in low-density structures. To evaluate the quality of initialization, we introduce the Initialization Point Cloud Structural Deviation (IPSD) metric. Experiments on the X3D dataset indicate that for the novel view synthesis task, LINGO improves the Peak Signal-to-Noise Ratio (PSNR) and Structural Similarity Index (SSIM) by an average of 0.72 and 0.0039, respectively, over baselines under identical sparse-view settings, achieving comparable reconstruction quality within 5k steps to state-of-the-art models typically trained with 30k iterations. For the CT reconstruction task, LINGO also demonstrates consistent improvements, with average PSNR and SSIM gains of 0.36 and 0.0134. These results highlight LINGO's effectiveness in both accelerating training and enhancing reconstruction quality across different sparse-view imaging scenarios.

0.37

Feed-Forward Hierarchical Gaussian Diffusion for Extreme CT Reconstruction

cs.CV ·2026-08-15 ·Yuezhe Yang, Li Cheng
benchmarkcode/data similarity 0.67
Abstract

Reconstructing three-dimensional computed tomography (CT) from severely constrained projections is highly ill-posed. Sparse angular sampling, restricted angular coverage, and low photon counts can occur individually or jointly, obscuring global anatomy and local tissue detail. Many learned CT reconstruction methods are tailored to a single dominant degradation. Existing diffusion and Gaussian approaches commonly recover global structure and local detail within a shared representation. We propose HiGDiff, a feed-forward hierarchical Gaussian diffusion framework that decomposes reconstruction both spatially and from structure to detail. Physics-conditioned anatomical anchors and a foreground capacity field allocate learnable Gaussian primitives to informative regions. A structure diffusion stage first recovers global attenuation geometry, and its learned representation conditions a detail diffusion stage for residual boundaries and tissue transitions. The resulting Gaussian banks are rendered as attenuation fields and further refined by a gradient-isolated residual module. Experiments on three distinct CT benchmark datasets demonstrate state-of-the-art reconstruction performance across isolated, paired, and joint degradation settings, including improvements of 5.81 dB in macro-average peak signal-to-noise ratio (PSNR) and 0.113 in structural similarity index measure (SSIM) on the Low Dose CT Image and Projection Data (LDCT-PD) collection. Code and experimental configurations are openly available at https://github.com/Bean-Young/HiGDiff.

0.24

PhyDiCT: Plug-and-Play CT Reconstruction from Sparse X-Rays via Differentiable Rendering and Strong Priors

cs.CV ·2026-10-07 ·Weicheng Dai, Shantanu Ghosh, Kayhan Batmanghelich
top venuecode/data similarity 0.63
Abstract · Accepted at MICCAI 2026; to appear in LNCS 16888

Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric information. We propose PhyDiCT, a training-free framework that integrates a differentiable Physics-based forward model, grounded in the Beer-Lambert law, with a text-conditioned Diffusion as a strong prior to reconstruct 3D lung CT images. We refer to our approach as training-free since the prior model is used without fine-tuning, and our goal is to steer the denoising procedure to generate samples consistent with X-ray observations. We guide the diffusion generation using Split Gibbs sampling to jointly optimize for projection fidelity (reward) and consistency with prior knowledge. Also, we introduce a test-time refinement step that enhances image realism and anatomical coherence. We extensively evaluate our method on publicly available 3D CT datasets using both perceptual and semantic metrics, demonstrating that it surpasses existing plug-and-play diffusion and fully trained reconstruction approaches. Our findings highlight that combining a strong generative prior with the underlying physics of image formation substantially improves reconstruction quality, e.g., 7.5\% improvement on SSIM compared to full training methods. Code will be released at https://github.com/batmanlab/PhyDiCT.

0.44

Unified Projection-Domain Material Decomposition for Energy-Integrating and Photon-Counting CT

eess.IV physics.med-ph ·2026-10-21 ·Dale Black, Surya Naidu, Hamidreza Khodajou-Chokami, Sabee Molloi
theory similarity 0.63
Abstract · 27 pages, 10 figures, 6 tables

Objective: To develop a unified and efficient method for projection-domain material decomposition in spectral computed tomography (CT) that incorporates an arbitrary number of spectral measurements, independent of the acquisition mechanism, without reducing the measurements to two effective energies. Approach: A nested optimization method was developed for two-material basis decomposition from K>=2 spectral measurements. It extends an existing two-measurement univariate method by replacing its polynomial approximation with profile minimization of the Poisson negative log-likelihood, reducing the inversion to two one-dimensional searches that use all measurements without spectral rebinning. The method was evaluated in simulation for energy-integrating (GE Revolution Apex Elite, Siemens SOMATOM Flash) and photon-counting (Siemens NAEOTOM Alpha) CT. Main results: The method recovered line integrals with noiseless iodine errors below 3e-6 g/cm^2 and noise within 3% of the Cramer-Rao lower bound (CRLB). Virtual monoenergetic images (VMIs) agreed, at 70 keV and above, with reference CT numbers and, on all three systems, with vendor VMIs of physical scans (mean absolute error 6-22 HU). For photon counting, four measurements instead of two reduced the iodine CRLB by 19% and image noise by 8-16% at every VMI energy, and lowered the regression error at 70 keV and above. Iteration and tolerance settings changed CT numbers by less than 0.04 HU, and decomposition took 0.34-0.67 s per million rays on an A100 GPU. Significance: The method provides fast, accurate decomposition for any spectral CT acquisition mechanism and number of measurements, so one method can serve every scanner in a virtual imaging trial.

0.25

AD-GS: Anatomical Density-guided 3D Gaussian Splatting for Sparse-View Dental CBCT Reconstruction

cs.CV ·2026-10-10 ·Zonglin Li, Kexian Xie, Feiran Li, Chu Zhou, Yixing Huang +3 more
code/data similarity 0.63
Abstract

Sparse-view Cone-Beam Computed Tomography (CBCT) reconstruction is essential for reducing radiation dose and scan effort, but remains underconstrained due to limited projection information. Recent 3D Gaussian Splatting (3DGS)-based CBCT reconstruction methods rely on gradient-driven densification, which becomes unstable under sparse acquisition and often leads to over-smoothed structures. We propose AD-GS, an Anatomical Density-guided 3D Gaussian Splatting framework that formulates Gaussian densification as an attenuation-aware Markov Chain Monte Carlo (MCMC) sampling process. By interpreting Gaussians as samples from an underlying anatomical attenuation distribution, AD-GS adaptively concentrates representation capacity in high-attenuation regions, enabling sharper structural boundaries under sparse projections. To further constrain reconstruction, we incorporate a semantic regularization based on zero-shot features from Segment Anything in Medical Images, enforcing multi-view consistency through semantic priors. Experiments on the ToothFairy3 dental CBCT dataset demonstrate that AD-GS achieves superior structural fidelity and boundary preservation compared with existing 3DGS-based approaches under sparse-view settings within the dental and maxillofacial setting. Code is available at https://github.com/yulinjiaxue/AD-GS-BMVC2026.

0.29