CS Paper Radar

Gaussian Material Fields for Volumetric Multi-Energy CT Decomposition

Jian Lin, Jiancheng Fang, Hongming Shan, Shaoyu Wang, Yang Chen, Qiegen Liu

cs.CV ·submitted 2026-10-07 05:47 UTC · v1

Abstract

Volumetric material decomposition in multi-energy computed tomography requires a representation that organizes multiple three-dimensional material fields in a common spatial domain while retaining differences in composition and local structure. We observe that spatial primitives can be shared across materials without tying their coefficients, but their local capacity must respond to material-specific reconstruction needs. We introduce Gaussian material fields, which represent multiple material distributions with shared anisotropic 3D Gaussian primitives and independent nonnegative material coefficients. The shared geometry defines a continuous spatial basis, while the coefficients determine each primitive's contribution to the individual material fields. To reconstruct this representation from multi-energy projections, a differentiable spectral forward model combines Gaussian material path integrals with a calibrated basis matrix, enabling joint optimization of spatial geometry and material composition. Material-aware adaptive density control retains material-specific refinement evidence before aggregation and adjusts local representation capacity to accommodate both spatially extensive components and sparse details. Experiments use synthesized multi-energy projections generated from pseudo-reference material maps constructed by conventional methods from publicly available CT data. Across 15 cases, our approach improves average PSNR by 4.03 dB and SSIM by 4.96% over the strongest baseline, while reducing NRMSE by 33.45%. Material-wise comparisons and component ablations support improved recovery of localized structures, while runtime and memory measurements show favorable computational scaling. These results establish Gaussian material fields as an explicit, adaptive representation for volumetric multi-material reconstruction.

Comment
13 pages, 12 figures

Closest papers

Nearest neighbours by meaning across the whole index.

SpectralCTGaussians: Projection-Domain Reconstruction and Basis Material Decomposition for Spectral CT using 3D Gaussian Splatting

cs.CV ·2026-08-29 ·Reinout Vos, Saptarshi Neil Sinha, Michael Weinmann
similarity 0.74
Abstract

Spectral computed tomography (CT) extends conventional CT by measuring attenuation across multiple energy channels, allowing improved modeling of physical X-ray interactions and energy-dependent material behavior and leading to richer scene understanding. We present a novel method for spectral CT reconstruction and basis material decomposition using 3D Gaussian Splatting by adding per-Gaussian basis material fractions to the set of learnable parameters, which together with a set of energy-dependent basis functions define the attenuation across the full spectral range. The basis functions represent various physical attenuation models such as photoelectric absorption and Compton scattering, and are jointly optimized across all energy channels through a differentiable polychromatic forward model, with material decomposition performed via mean-shift clustering of the resulting coefficients. We evaluate our method on a baseline real-world dataset as well as a synthetic dataset that we introduce, comparing against traditional reconstruction algorithms and state-of-the-art learning-based CT reconstruction methods. Our approach outperforms all traditional baselines in novel view synthesis and achieves the best PSNR among all compared methods for spectral CT volume reconstruction, while describing all energy channels with a single shared representation that requires a number of Gaussians comparable to single-channel Gaussian splatting-based CT reconstruction approaches. For basis material decomposition, no traditional or learning-based baseline offers one-step decomposition with direct RGB material segmentation, and our method additionally recovers the photoelectric basis with higher PSNR than traditional pipelines.

0.25

Feed-Forward Hierarchical Gaussian Diffusion for Extreme CT Reconstruction

cs.CV ·2026-08-15 ·Yuezhe Yang, Li Cheng
benchmarkcode/data similarity 0.66
Abstract

Reconstructing three-dimensional computed tomography (CT) from severely constrained projections is highly ill-posed. Sparse angular sampling, restricted angular coverage, and low photon counts can occur individually or jointly, obscuring global anatomy and local tissue detail. Many learned CT reconstruction methods are tailored to a single dominant degradation. Existing diffusion and Gaussian approaches commonly recover global structure and local detail within a shared representation. We propose HiGDiff, a feed-forward hierarchical Gaussian diffusion framework that decomposes reconstruction both spatially and from structure to detail. Physics-conditioned anatomical anchors and a foreground capacity field allocate learnable Gaussian primitives to informative regions. A structure diffusion stage first recovers global attenuation geometry, and its learned representation conditions a detail diffusion stage for residual boundaries and tissue transitions. The resulting Gaussian banks are rendered as attenuation fields and further refined by a gradient-isolated residual module. Experiments on three distinct CT benchmark datasets demonstrate state-of-the-art reconstruction performance across isolated, paired, and joint degradation settings, including improvements of 5.81 dB in macro-average peak signal-to-noise ratio (PSNR) and 0.113 in structural similarity index measure (SSIM) on the Low Dose CT Image and Projection Data (LDCT-PD) collection. Code and experimental configurations are openly available at https://github.com/Bean-Young/HiGDiff.

0.24

Shared-Structure 4D Spectral Gaussian Representation for Sparse-View Spectral CT Reconstruction

cs.CV ·2026-08-17 ·Jiancheng Fang, Shaoyu Wang, Wenjun Xia, Yang Chen, Qiegen Liu
similarity 0.65
Abstract

Sparse-view spectral computed tomography (CT) reconstructs energy-resolved attenuation volumes from limited projection views, requiring simultaneous handling of angular undersampling and spectral coupling. We propose a SharedStructure 4D Spectral Gaussian Representation (4D-SG) that learns shared Gaussian geometry from full spectrum structural projections and uses a Gaussian-wise Spectral Density Curve Network (GSC-Net) to predict Gaussian raw density transformations. This factorization separates shared spatial structure from spectral attenuation variation, avoids independent channel geometry optimization, and establishes a continuous 4D-SG representation from discrete spectral measurements for unobserved spectral channel queries. Experiments on six synthesized, simulated projection, and real projection datasets with 50 views demonstrate the best average performance. Compared with the strongest Gaussian baseline, 4D-SG improves PSNR from 35.56 dB to 36.61 dB, increases SSIM from 0.909 to 0.914, and reduces LPIPS from 0.208 to 0.194, demonstrating its effectiveness for sparse-view spectral CT reconstruction.

0.15

EPC-RawDC: Equivariant Physics Constrained 3D Diffusion with Raw Data Consistency for CBCT to CT Image Synthesis

cs.CV cs.AIphysics.med-ph ·2026-10-29 ·Alzahra Altalib, Chunhui Li, Alessandro Perelli
code/datahot direction similarity 0.62
Abstract · 10 pages, 4 figures, 8 tables

Cone beam computed tomography (CBCT) is widely used for image guided and adaptive radiotherapy, but scatter, noise, reconstruction artifacts, and inaccurate Hounsfield units limit its quantitative use. Recent diffusion approaches for CBCT to CT synthesis remain largely image driven, with limited use of the underlying acquisition physics. We propose EPC-RawDC, a conditional 3D latent diffusion framework that combines volumetric generative modeling with two complementary constraints derived from the same scanner specific CBCT forward model. First, geometry equivariant projection constraint exploits the rotational equivariance of the CBCT forward operator by supervising the synthesized CT through correspondingly transformed reference projections. Second, raw data consistency uses noisy projection measurements of the individual acquisition as scan specific supervision during training. The framework was evaluated on two independent clinical cohorts with distinct scanner geometries and projection sources. For JUST, the physics constraints used measured clinical raw CBCT projections acquired with an Elekta system, whereas for SynthRAD2025 the projection data were simulated from the reference CT using a Varian geometry with Poisson photon statistics. EPC-RawDC achieved an SSIM of 0.97 in both cohorts and improved PSNR over DDPM by 2.66 dB on SynthRAD2025 and 2.10 dB on JUST, while reducing mean MAE by 20.3% and 19.0%, respectively. On SynthRAD2025, projection consistency and equivariant errors were reduced by 55.0% and 41.4% relative to DDPM. These results demonstrate that combining a volumetric diffusion prior with scanner geometry and scan specific projection measurements improves quantitative CBCT to CT synthesis across both simulated and measured projection domains. Code available after publication at https://github.com/ALZAHRAALTALIB/EPC-RawDC.

0.37

MedGSSR: Generalizable Medical Image Super-Resolution 3D Reconstruction via Hierarchical Feed-forward Gaussian Splatting

eess.IV cs.CEcs.CVq-bio.QM ·2026-09-06 ·Chengkai Wang, Luoyu Hong, Yiting Zhao, Jiamin Wang, Xiang Feng +5 more
top venue similarity 0.62
Abstract · ECCV 2026

High-resolution volumetric medical imaging is critical for clinical diagnosis, yet acquisition is often limited by scanner hardware, scan time, and for CT, radiation dose. Medical 3D Super-Resolution (Med3DSR) offers a computational alternative, but existing methods commonly rely on per-subject optimization, pretrained priors, or coordinate-based implicit representations, which compromise anatomical fidelity and limit efficiency. To address these limitations, we present MedGSSR, a fully end-to-end feed-forward framework that represents volumes as an explicit 3D Gaussian field for Med3DSR. Unlike coordinate-based implicit functions, our explicit 3D Gaussian representation naturally enhances signal continuity and local high-frequency fidelity. Specifically, MedGSSR explicitly decouples the reconstruction process into coarse-grained structural preservation and fine-grained textural refinement through the proposed Pyramid Anatomical Encoder and a Hierarchical Gaussian Projector. To support arbitrary-scale super-resolution, we introduce sub-voxel Gaussian decomposition and a Differentiable Gaussian Voxelizer that directly queries the continuous 3D intensity field, reducing discretization artifacts. Extensive experiments on MRI and CT benchmarks demonstrate that MedGSSR significantly outperforms state-of-the-art methods. Notably, our framework exhibits robust generalizability across unseen datasets without requiring per-subject optimization, enabling fast inference and high-fidelity volumetric super-resolution in practical clinical settings. Our project webpage, including code, is at https://william2ai.github.io/medgssr

0.47

Unified Projection-Domain Material Decomposition for Energy-Integrating and Photon-Counting CT

eess.IV physics.med-ph ·2026-10-21 ·Dale Black, Surya Naidu, Hamidreza Khodajou-Chokami, Sabee Molloi
theory similarity 0.62
Abstract · 27 pages, 10 figures, 6 tables

Objective: To develop a unified and efficient method for projection-domain material decomposition in spectral computed tomography (CT) that incorporates an arbitrary number of spectral measurements, independent of the acquisition mechanism, without reducing the measurements to two effective energies. Approach: A nested optimization method was developed for two-material basis decomposition from K>=2 spectral measurements. It extends an existing two-measurement univariate method by replacing its polynomial approximation with profile minimization of the Poisson negative log-likelihood, reducing the inversion to two one-dimensional searches that use all measurements without spectral rebinning. The method was evaluated in simulation for energy-integrating (GE Revolution Apex Elite, Siemens SOMATOM Flash) and photon-counting (Siemens NAEOTOM Alpha) CT. Main results: The method recovered line integrals with noiseless iodine errors below 3e-6 g/cm^2 and noise within 3% of the Cramer-Rao lower bound (CRLB). Virtual monoenergetic images (VMIs) agreed, at 70 keV and above, with reference CT numbers and, on all three systems, with vendor VMIs of physical scans (mean absolute error 6-22 HU). For photon counting, four measurements instead of two reduced the iodine CRLB by 19% and image noise by 8-16% at every VMI energy, and lowered the regression error at 70 keV and above. Iteration and tolerance settings changed CT numbers by less than 0.04 HU, and decomposition took 0.34-0.67 s per million rays on an A100 GPU. Significance: The method provides fast, accurate decomposition for any spectral CT acquisition mechanism and number of measurements, so one method can serve every scanner in a virtual imaging trial.

0.25

TR-GS: High-Fidelity Sparse-View CT Volumetric Rendering via t-Distribution Gaussian Splatting and Ray-Confidence Modeling

cs.CV ·2026-08-17 ·Zedong Xiao, Yiren Wang, Zhou Liu, Xiaolin Liu, Zhangji Lu
top venue similarity 0.61
Abstract

High-fidelity 3D medical visualization supports applications such as clinical assessment and surgical planning. Sparse-view computed tomography (CT) can reduce projection requirements and associated radiation exposure, but limited observations may introduce structural artifacts and reconstruction uncertainty. Although 3D Gaussian Splatting (3DGS) provides an efficient explicit representation for volumetric rendering, existing CT methods based on standard Gaussian primitives may be sensitive to unreliable observations under sparse-view acquisition. We present TR-GS, a Gaussian-splatting framework for sparse view CT volumetric rendering. TR-GS replaces standard Gaussian primitives with projectable Student's t-distribution primitives and introduces a ray-confidence model that regulates their degrees of freedom according to local ray observability. Confidence-guided 3D wavelet regularization is further used to balance high-frequency detail preservation and noise suppression. This work is licensed under a Creative Commons Attribution 4.0 International License. Experiments on synthetic and real-world datasets show that TR-GS improves over representative baselines in most evaluated settings and remains competitive in the remaining cases. The resulting volumetric representations may support downstream medical multimedia applications, including XR-based visualization and interactive clinical rendering.

0.51

PhyDiCT: Plug-and-Play CT Reconstruction from Sparse X-Rays via Differentiable Rendering and Strong Priors

cs.CV ·2026-10-07 ·Weicheng Dai, Shantanu Ghosh, Kayhan Batmanghelich
top venuecode/data similarity 0.60
Abstract · Accepted at MICCAI 2026; to appear in LNCS 16888

Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric information. We propose PhyDiCT, a training-free framework that integrates a differentiable Physics-based forward model, grounded in the Beer-Lambert law, with a text-conditioned Diffusion as a strong prior to reconstruct 3D lung CT images. We refer to our approach as training-free since the prior model is used without fine-tuning, and our goal is to steer the denoising procedure to generate samples consistent with X-ray observations. We guide the diffusion generation using Split Gibbs sampling to jointly optimize for projection fidelity (reward) and consistency with prior knowledge. Also, we introduce a test-time refinement step that enhances image realism and anatomical coherence. We extensively evaluate our method on publicly available 3D CT datasets using both perceptual and semantic metrics, demonstrating that it surpasses existing plug-and-play diffusion and fully trained reconstruction approaches. Our findings highlight that combining a strong generative prior with the underlying physics of image formation substantially improves reconstruction quality, e.g., 7.5\% improvement on SSIM compared to full training methods. Code will be released at https://github.com/batmanlab/PhyDiCT.

0.44