LBW-NPS: A Local Band-Weighted Noise Power Spectrum Loss for Texture-Preserving Low-Dose CT Denoising

Fatma Elif Yalçındağ, Mehmet Ozan Ünal, Metin Ertaş, İsa Yıldırım

eess.IV ·submitted 2026-11-19 05:52 UTC · v1
code/data

Abstract

Low-dose CT denoising should suppress noise while retaining the local texture of the reference image. Matching a pooled spectrum can overlook regional discrepancies, whereas pixel losses alone can favor overly smooth outputs. We propose a local band-weighted noise power spectrum loss (LBW-NPS) that compares spectral energies within overlapping Hann-tapered patches, without tissue-specific loss conditioning. Each valid patch contributes a weighted squared log-energy difference across three frequency bands, alongside an $L_1$ reconstruction term. We compare LBW-NPS against $L_1$-only training and five auxiliary-loss baselines using the same U-Net and three seeds on DeepLesion slices with simulated low-dose acquisitions, including patch-scale ablations and lung, soft-tissue, and bone evaluations. On 220 test slices from 31 patients, LBW-NPS reduces a local spectral gap related to the loss, on $64\times64$-pixel evaluation windows, by 31.9% relative to pooled band-weighted NPS, without a statistically significant PSNR change. This improvement is supported by lower errors relative to the reference in average NPS frequency and gray-level co-occurrence matrix (GLCM) measures not used in the loss, evaluated in homogeneous soft tissue. Local band-power matching therefore improves regional texture agreement without changing the denoising architecture.

Comment
5 pages, 3 figures, 2 tables. Submitted to IEEE ISBI 2027. Code: https://github.com/itu-biai/lbw-nps

Closest papers

Nearest neighbours by meaning across the whole index.

RIQE: a NIQE-style reference model for Computed Tomography

eess.IV cs.CV ·2026-09-30 ·Fabio Mattiussi
code/data similarity 0.62
Abstract · 17 pages, 6 figures, 6 tables. Code and model: https://github.com/Metallogik/RIQE, archived at doi:10.5281/zenodo.23055559

The Natural Image Quality Evaluator (NIQE) scores an image by its statistical distance from a model fitted on pristine images, and its distributed model is fitted on photographs. We release the Radiology Image Quality Evaluator (RIQE), a NIQE-style model fitted on 3,792 full-dose slices from 158 patients of the public LDCT-and-Projection-data collection, with a declared intensity mapping, a manifest of every slice and a script that reproduces the fit. On 40 held-out patients, RIQE ranks reduced-dose reconstructions, simulated by projection-domain noise insertion, worse than the full-dose reconstruction of the same slice in 240 of 240 chest and 230 of 240 abdominal pairs, and ranks images with 20% more noise worse than their source in 97.5-100% of cases. Its preferences among filtered images, however, do not follow lesion signal. With a 4 mm, +10 HU lesion inserted in noisy abdominal slices, RIQE prefers bilateral filtering to the unfiltered image in every image up to a 32 HU residual, at which 29% of the lesion's matched-filter signal remains and its detectability index falls from 0.51 to 0.33; it never prefers Gaussian smoothing, which at the same 32 HU residual leaves 70% of the signal and a detectability index of 0.48. Fitted on photographs with the parameters published for NIQE, the same code ranks every simulated reduced-dose abdominal image better than its full-dose counterpart. RIQE is suited to ranking a degraded image against its source; under the conditions tested it should not be the sole criterion for selecting, comparing or tuning denoisers.

0.57

Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising

eess.IV ·2026-09-30 ·Ping Wu, Pengcheng Zheng, Jiahao Zhang, Bohao Chen, Yazhou Ren +1 more
similarity 0.62
Abstract · 10 pages

Low-dose CT (LDCT) reduces radiation exposure but often introduces severe noise and streak artifacts that obscure subtle anatomical structures. Existing diffusion-based denoising methods commonly rely on implicit assumptions about the noise distribution, which may not hold in practical LDCT scenarios and can degrade denoising performance. To address this limitation, we propose a Residual-Guided Diffusion framework that effectively incorporates an explicit difference prior to inform the diffusion process of noise distribution. The difference prior is computed as the residual between the LDCT image and a coarse clean estimate, constraining diffusion sampling to a plausible residual space. We further adopt a coarse-to-fine strategy in which a pre-trained RED-CNN provides the coarse estimate to anchor global anatomy, and the diffusion model refines the remaining details under the prior guidance. For efficiency, we employ accelerated sampling with 20 steps at inference. Experiments on three representative datasets demonstrate that our approach outperforms existing methods in both quantitative and qualitative performance measures.

0.14

Conditioning noise is a free regularizer for LoRA fine-tuning: no pathology encoder required for diffusion-based artifact detection in histopathology

eess.IV cs.CV ·2026-09-11 ·Konstantinos Moutselos, Ilias Maglogiannis
code/data similarity 0.61
Abstract · 23 pages, 3 figures. Code and laboratory record: https://github.com/kmouts/condnoise-histoqc (doi:10.5281/zenodo.22702198). Data: doi:10.528…

Diffusion-based artifact detectors score whole-slide image patches by reconstruction error under a model fine-tuned on clean tissue. We show that conditioning this fine-tuning on random Gaussian embeddings -- resampled at every step from approx. 200 KB of precomputed embedding statistics, with no encoder, no cache, and no change to inference -- consistently widens the clean/artifact separation. A four-step ablation chain shows the benefit requires neither content (shuffled real embeddings), provenance (synthetic Gaussians), a tuned intensity (flat across an 8x variance range), nor per-patch identity (fresh per-step noise); a LoRA-dropout control shows the conditioning pathway specifically, not generic weight perturbation, carries the effect. Patch-level gains of +0.25-0.48 Cohen's d replicate across nine trainings; honest leave-one-slide-out evaluation clears a pre-registered bar in 2/2 seeds; and two pre-registered external endpoints on a 281-case set confirm pooled Delta F1 = +0.0073 (95% CI) and +0.0129 (97.5% CI, two-look corrected). We release the full evaluation protocol, including measured seed noise and selection-optimism pricing.

0.50

DoseBridge: Denoising Diffusion Bridge Model for Dose Prediction in Lung Intensity-Modulated Proton Therapy

cs.CV ·2026-08-10 ·Zerun Zhang, Xiaoda Cong, Xiangkun Xu, Peter Y. Chen, Xuanfeng Ding
similarity 0.60
Abstract

Most radiotherapy dose-prediction models use only CT images and anatomical structures, although intensity-modulated proton therapy (IMPT) dose also depends strongly on beam geometry and available clinical datasets are often small. We present DoseBridge, a denoising diffusion bridge model that uses the patient CT as a structured bridge endpoint and encodes plan-specific beam geometry in a spatially aligned beam mask. Multiscale fusion combines CT, target, organ-at-risk, and beam-mask representations with 1.95% additional parameters. DoseBridge was retrospectively evaluated on single-institution CT images and treatment plans from 52 patients with advanced-stage lung cancer treated with 60 Gy in 30 fractions; 42 cases were used for training and 10 for testing. Performance was assessed using image-similarity, dose-volume, and Lyman-Kutcher-Burman normal-tissue complication probability (NTCP) metrics and compared with two deep-learning models. On the test cohort, DoseBridge achieved a mean absolute error of 4.170 Gy, peak signal-to-noise ratio of 23.06 dB, and structural similarity index of 0.798, outperforming both comparison models on these metrics. Clinical target volume D95 differed from the reference dose by 0.62 +/- 1.6 Gy; signed organ-at-risk mean-dose differences ranged from -0.32 to 0.24 Gy, and NTCP differences were -0.40 +/- 2.2 and 0.52 +/- 3.4 percentage points for acute esophagitis and radiation pneumonitis, respectively. Changing only the beam mask redirected predicted low-dose entrance regions while preserving the high-dose target region. To our knowledge, DoseBridge is the first denoising diffusion bridge model for radiotherapy dose prediction. These results support its feasibility as a beam-aware planning prior for lung IMPT, pending evaluation in larger external cohorts.

0.04

Noise2Match: Self-Supervised Low-Dose CT Denoising via Adaptive Inter-Slice Matching

cs.CV ·2026-10-13 ·Langrui Zhou, Guang Li, Xinyu Huang, Ziteng Zhou, Zuyang Huang +3 more
top venue similarity 0.60
Abstract

With the rapid development of deep learning, supervised convolutional neural network methods have greatly improved the performance of low-dose computed tomography (CT) denoising. However, they require paired noisy-clean training data, which is difficult to obtain in practice. Some classic self-supervised denoising methods rely on the assumption of pixel-wise independent noise, making them ineffective for correlated noise in low-dose CT (LDCT) images. Considering the high similarity and weaker noise correlation between adjacent CT slices, several recently proposed self-supervised methods use adjacent LDCT slices for training. Nevertheless, these approaches fail to effectively account for the non-rigid misalignment between slices caused by anatomical variation, hindering them from satisfying the equal-mean condition required by the classic Noise2Noise framework. In this paper, we propose Noise2Match, a self-supervised LDCT denoising method based on adaptive inter-slice matching. Noise2Match introduces an inter-slice matching network to model the label transition process between adjacent slices, and then applies correction to the denoiser's outputs to better satisfy the equal-mean condition. We theoretically prove that, under idealized conditions, training Noise2Match using adjacent LDCT slices is equivalent to supervised training with paired noisy-clean images. We further find that Noise2Match can also effectively perform low-dose conebeam CT (CBCT) denoising, which could be attributed to its correction operation that reduces inter-slice noise correlation. To the best of our knowledge, Noise2Match is the first effective image-domain self-supervised method for low-dose CBCT. Extensive experiments demonstrate that Noise2Match outperforms existing image-domain selfsupervised methods, offering broader applicability and higher practical value.

0.33

One Step Is Optimal: Unconditional Rectified Flows as Noise2Noise Denoisers for Low-Dose CT

cs.CV ·2026-09-15 ·Timothy Sereda, Debesh Jha
benchmark similarity 0.59
Abstract · 15 pages, 3 figures

We study rectified flows for denoising without clean training targets. For an unconditional rectified flow trained on Noise2Noise pairs, the optimal velocity field yields the minimum mean squared error (MMSE) denoiser in one step. In a jointly Gaussian model, we show that integrating the flow before applying its denoising readout increases error with integration time. The flow transports between noisy distributions, so its endpoint is not a clean-image estimate. Experiments on low-dose CT and Gaussian-corrupted natural images follow this pattern: one-step flow performs similarly to direct regression on the same pairs, whereas additional Euler steps reduce PSNR. A direct regressor using spatially separated, similar patches gives our best label-free CT result, a $1.99$\,dB gain over the noisy input. We report these results in CTDenoiser, a benchmark covering five architectures, supervised and self-supervised training, and two per-image methods. Supervised CNNs gain about $4$\,dB, while label-free performance depends strongly on how training pairs account for correlated CT noise. A channelized Hotelling observer also shows that fidelity gains need not improve lesion detectability: detectability falls at $160$\,HU despite higher PSNR and SSIM, while changes at $40$--$80$\,HU are small. Code, model definitions, and data-loading utilities will be released publicly; the repository link is withheld for anonymous review.

0.31

Beyond Sparsity: Weight Location and Network Context in Pruned MRI Reconstruction

eess.IV cs.CV ·2026-09-25 ·Mohammed Wattad, Tamir Shor, Alexander M. Bronstein
similarity 0.59
Abstract

Pruning reduces the number of weights in magnetic resonance imaging (MRI) reconstruction networks. Equal sparsity, however, can retain weights with different computational roles and different compatibility with the trained network. We study these effects across 120 convolutional U-Net and vision transformer models using controlled edits evaluated before retraining. In U-Net, preserving high-resolution computation improves reconstruction at equal deletion counts across all tested sparsity levels. Equal-operation controls reveal additional sensitivity of the first convolution, which operation count alone cannot explain. In transformers, retained pretrained weight energy correlates with quality within sparsity levels, yet the same masks reverse their reconstruction ranking when the surrounding trained weights change. At 90\% sparsity, matching intermediate output scales largely removes a high-energy-mask penalty while retaining an advantage for the network's original mask. Thus sparsity alone does not characterize reconstruction quality: architecture-specific descriptors are informative, but mask quality can still depend on the surrounding trained network.

0.28

VoxelSynth3D: Interpretable Volumetric Image-Domain Metal Artifact Reduction with a Paired Synthetic CLINIC Benchmark

cs.CV ·2026-10-01 ·Amritesh Banerjee, Abdul Basit, Renil Renji Joseph, Nouhaila Innan, Muhammad Shafique
publishedbenchmark similarity 0.59
Abstract · 7 pages, 7 figures. Accepted for publication at BHI 2026

Metal artifacts in postoperative musculoskeletal CT obscure bone-implant and adjacent soft-tissue interfaces. Many metal artifact reduction (MAR) methods require unavailable raw projections or learned models that may shift across scanners and implants. We present VoxelSynth3D, a training-free 3D image-domain framework for reconstructed CT. The framework combines support masking, normalized tissue synthesis, deviation gating, and restricted edge refinement. Detected implant voxels are preserved in the output, while correction targets metal-induced artifacts in the surrounding tissue. We also construct Synthetic CLINIC-Metal, a controlled paired synthetic evaluation resource, from no-metal CTPelvic1K volumes with clean targets, metal/artifact masks, fixed seeds, and patient-level splits; 75 unpaired real metal cases receive qualitative/no-reference evaluation only. The operating point was fixed in a near-flat validation basin. With exact-mask oracle localization, all methods share a metal-excluded tissue ROI. On 40 held-out cases, VoxelSynth3D reduced RMSE from 801.48 to 786.18 HU (paired gain 15.30 HU, 95% CI 11.68-19.23), improving every case and exceeding the evaluated 3D Gaussian smoother by 13.58 HU. Clean-edge agreement decreased next to metal but exceeded input beyond 5 mm. Thus, VoxelSynth3D provides case-consistent within-distribution tissue-error reduction with a localized structural tradeoff. Spacing-aware sensitivity retained aggregate broad-region improvement and identified near-metal calibration as a target.

0.28