CS Paper Radar

Beyond Sparsity: Weight Location and Network Context in Pruned MRI Reconstruction

Mohammed Wattad, Tamir Shor, Alexander M. Bronstein

eess.IV cs.CV ·submitted 2026-09-25 13:46 UTC · v1

Abstract

Pruning reduces the number of weights in magnetic resonance imaging (MRI) reconstruction networks. Equal sparsity, however, can retain weights with different computational roles and different compatibility with the trained network. We study these effects across 120 convolutional U-Net and vision transformer models using controlled edits evaluated before retraining. In U-Net, preserving high-resolution computation improves reconstruction at equal deletion counts across all tested sparsity levels. Equal-operation controls reveal additional sensitivity of the first convolution, which operation count alone cannot explain. In transformers, retained pretrained weight energy correlates with quality within sparsity levels, yet the same masks reverse their reconstruction ranking when the surrounding trained weights change. At 90\% sparsity, matching intermediate output scales largely removes a high-energy-mask penalty while retaining an advantage for the network's original mask. Thus sparsity alone does not characterize reconstruction quality: architecture-specific descriptors are informative, but mask quality can still depend on the surrounding trained network.

Closest papers

Nearest neighbours by meaning across the whole index.

One Block Is Enough: LoopMR for Accelerated MRI Reconstruction

eess.IV cs.CV ·2026-11-11 ·Yimeng He, Yibin Xie, Yi Zheng, Yifan Gao, Lixia Wang +5 more
code/data similarity 0.74
Abstract · 10 pages, 7 figures, 6 tables. Code: https://github.com/hym97/LoopMR

Deep-learning unrolled networks are the leading approach to accelerated MRI reconstruction. State-of-the-art models such as PromptMR+ learn a distinct block for every cascade, so their size grows with the number of cascades. Sharing one block across iterations avoids adding parameters, but earlier shared-weight models typically used a tiny block and produced worse images than models with distinct weights. Therefore, it remained unclear whether weight sharing itself or the choice of block was the problem. Recent advances in looped transformers, which reuse the same block across layers, show that they can match or outperform their distinct-weight counterparts on several tasks. Motivated by this, we propose LoopMR, which reuses a single Restormer block at every iteration as its core. Besides the current image estimate, the block receives data-consistency inputs and latent images. On four datasets covering the brain (CC359), knee (fastMRI), heart (CMRxRecon2023) and carotid (in-house), LoopMR significantly outperforms E2E-VarNet, PromptMR and PromptMR+ in PSNR and SSIM at every acceleration factor (p < 0.01), with about 1/9 of PromptMR+'s parameters (10.3M versus 92.9M). It also keeps its lead at unseen acceleration factors and on an unseen dataset. With our transformer block, the shared model matches or outperforms its distinct-weight counterpart at 6, 12 and 24 iterations. At a fixed number of iterations, shared transformer blocks match or outperform their distinct-weight versions, while shared CNN blocks perform worse. These results suggest that looping one well-chosen block can outperform stacking distinct cascades in MRI reconstruction, with a fraction of the parameters.

0.24

Beyond Training from Scratch: Foundation Models for Data-Efficient and Generalizable Cardiac MRI Reconstruction

cs.CV ·2026-10-06 ·Anam Hashmi, Mayug Maniparambil, Julia Dietlmeier, Kathleen M. Curran, Noel E. O'Connor
publishedcode/data similarity 0.71
Abstract · Accepted at ECCVW 2026

Cardiac magnetic resonance imaging reconstruction aims to recover high-quality images from undersampled acquisitions, enabling faster scans while preserving diagnostic fidelity. Recent reconstruction methods are typically trained from scratch and often require large amounts of task-specific data, limiting their robustness under data scarcity and distribution shifts. In this work, we investigate whether pretrained vision foundation models can serve as effective priors for accelerated cardiac MRI reconstruction. We propose a reconstruction framework that integrates frozen and parameter-efficiently adapted visual encoders, including CLIP, BiomedCLIP, and DINOv2, within a transformer-based reconstruction architecture. Extensive experiments on the CMRxRecon2023 and CMRxRecon2024 benchmarks demonstrate that pretrained representations consistently outperform a transformer trained from scratch across multiple acceleration factors. We further evaluate performance under limited supervision and cross-dataset transfer, showing that foundation models provide superior data efficiency and generalization. While frozen representations are particularly effective in extreme low-data regimes, Low-Rank Adaptation (LoRA) yields additional gains when moderate amounts of training data are available. Among the evaluated backbones, DINOv2 achieves the strongest overall performance. These findings highlight the potential of vision foundation models as robust and transferable priors for cardiac MRI reconstruction.

0.31

Awaken, Then Scale: Tiny Adaptation for MRI Reconstruction

eess.IV cs.CV ·2026-09-25 ·Mohammed Wattad, Tamir Shor, Alexander M. Bronstein
similarity 0.69
Abstract

Dormant Awakening (DA) specializes a magnetic resonance imaging (MRI) reconstruction model by fitting a small set of zero weights to one labeled slice. Across fourteen U-shaped convolutional network (U-Net) and vision transformer (ViT) sources, fitting 1,004 or 10,560 weights gives mean peak signal-to-noise ratio (PSNR) gains of .430 and .509 dB. We analyze how scaling the fitted output correction changes evaluation PSNR, then use the calibration correction size to cap changes on new images. The cap bounds changes in root mean squared error (RMSE) relative to the source without an evaluation reference. At 10\% adaptation budget, we compare fixed halving and dynamic capping for DA, unrestricted sparse adaptation and low-rank adaptation (LoRA). The controls increase both measured calibration-evaluation correlations across all six tested architecture-adapter settings. Experiments concern one constructed fastMRI-to-M4Raw shift with fixed source checkpoints and participant panels.

0.19

One Evaluation, Any Operating Point: Hypernetwork-Amortized MeanFlow for 3D MRI Reconstruction

cs.CV ·2026-09-15 ·Ruibo Wang
similarity 0.69
Abstract · 38 pages (9-page main text plus appendices)

Generative priors reconstruct accelerated 3D MRI well but pay heavily at deployment: tens of network evaluations per volume, and protocol-specific hyperparameter tuning. A third hidden cost is the scanner's fixed sampling pattern. We treat the whole operating point as an input. A 3D MeanFlow patch network (a one-step flow model) is fine-tuned end-to-end through a warm-started, five-iteration differentiable conjugate-gradient projection. A small hypernetwork maps the operating point (data-consistency weight, acceleration, and the Cartesian sampling pattern itself) to the network's per-channel modulation. Three findings follow. (i) Learning the acquisition is worth more than any other operating point: on clinical knee data, the learned mask gains up to +2.34 dB over the protocol's variable-density mask. This gain requires the solver: with a feed-forward reconstructor the same learned mask hurts at 4x (-1.7 dB), but with the data-consistency projection it adds +4.6 dB. (ii) One evaluation is highly effective: it beats a 20-step patch-diffusion prior by up to +3.1 dB on brain and +2.9 dB on knee. Three to five evaluations extend the front to +6 dB while using a quarter of the prior's network calls. (iii) Fully sampled targets are optional: trained self-supervised on a split of acquired samples, the reconstructor matches its supervised twin at 4x on real data. Finally, we report what failed and why: subject-adaptive acquisition from measured energy, combining self-supervision with learned acquisition, and amortising the data-consistency weight.

0.23

Consistency Models for Fast MRI Reconstruction Using Regularization by Denoising

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-20 ·Merve Gülle, Junno Yun, Yaşar Utku Alçalar, Mehmet Akçakaya
code/data similarity 0.69
Abstract

Diffusion models (DMs) have emerged as powerful generative priors for MRI reconstruction with promising results. Yet DM-based methods require extensive iterative refinement, limiting their practical deployment. Consistency models (CMs) provide a compelling alternative, aiming to map out the diffusion trajectory in a single pass, enabling faster generation. In this work, we propose CM-RED, a novel MRI reconstruction method that integrates a pretrained CM into the regularization by denoising (RED) scheme. Our method builds on accelerated proximal gradient RED (RED-APG), and further incorporates controlled noise injection during the update steps to enhance generative diversity and accelerate convergence. Extensive experiments on the fastMRI knee and brain datasets demonstrate that CM-RED achieves high-quality reconstructions across multiple anatomies, contrast weights, acceleration factors, and undersampling patterns, using only 4 network function evaluations (NFEs). The proposed method consistently outperforms existing DM- and CM-based approaches in both quantitative metrics and visual fidelity, and exhibits strong robustness to hyperparameter variations, highlighting CM-RED as an efficient and effective generative framework for accelerated MRI reconstruction. The source code and pretrained models are publicly available at https://github.com/MerveGulle/CM-RED.

0.31

Scalable Unrolled Chains for MRI Reconstruction

cs.CV ·2026-10-24 ·Emiljo Mëhillaj, Ender Konukoglu
publishedcode/data similarity 0.67
Abstract · 23 pages (including supplementary material), 14 figures. Accepted at WACV 2027

Unrolled variational networks achieve state-of-the-art performance for accelerated MRI reconstruction, but standard end-to-end training becomes prohibitively memory intensive as the number and width of cascades increase. We propose a memory-efficient training framework that updates a randomly sampled cascade while retaining supervision from the final reconstruction loss. The error signal is propagated from the end of the chain to the sampled cascade using an activation-light backward pass that avoids storing full chain activations, thereby decoupling training memory from chain length. A time-conditioned network shared across cascades further keeps the parameter count independent of chain length. The backward pass is approximate only through frozen normalization statistics, and a trained exact gradient control shows the approximation leaves reconstruction quality unchanged. The framework remains trainable at chain lengths and cascade widths where standard end-to-end backpropagation exhausts GPU memory. On fastMRI single-coil knee and multi-coil brain reconstruction, our method consistently outperforms other local training approaches. On high-SNR knee slices, our method surpasses E2E-VarNet at $8\times$ and matches it at $4\times$, while on the complete brain validation set it surpasses E2E-VarNet at $8\times$ and achieves comparable performance at $4\times$, with fewer parameters, lower peak memory, and faster per-iteration training. Code is available at https://github.com/emehillaj/scalable-unrolled-mri.

0.50

Anatomically Faithful Artifact Suppression in SENSE Accelerated Brain MRI

eess.IV cs.CV ·2026-09-18 ·Changjing Chai, Bin Huang, Libo Xu, Jian Zhou, Boyang Pan +3 more
similarity 0.67
Abstract · 18 pages of main text, 2 pages of appendix, 6 figures, and 6 tables (including 2 appendix tables)

Background: Four-fold accelerated sensitivity encoding (SENSE4) can shorten brain MRI acquisition time but may amplify noise and result in residual aliasing artifacts after conventional reconstruction. Purpose: To evaluate whether an image-domain refinement framework can improve the quality of SENSE4 brain MRI while preserving anatomical information for quantitative measurements. Methods: In this prospective paired study, 80 participants underwent fully sampled and four-fold accelerated SENSE T1-weighted MRI. We developed an Anatomy-aware Residual Attention Network (ART-Net) to refine accelerated reconstructions through generalized self-attention and correlation-based residual artifact regularization. Participant-level splitting yielded training, validation, and independent test cohort (45/5/30 participants). The independent test cohort underwent quantitative, segmentation-based, and blinded radiologist assessments of image quality and anatomical preservation. Results: ART-Net demonstrated highly competitive reconstruction performance, achieving the highest peak signal-to-noise ratio (31.03 +/- 2.88 dB) and structural similarity index (0.963 +/- 0.022) among evaluated methods. It also demonstrated improved anatomical fidelity, with numerically highest Dice coefficients for medial temporal structures relevant to atrophy assessment (0.8824 +/- 0.0827) and whole-brain regions (0.8857 +/- 0.0885). Moreover, ART-Net improved gradient fidelity, regional contrast preservation, and radiologist-rated structural quality. Conclusion: ART-Net improved agreement between SENSE4 and fully sampled T1-weighted images in a single-center, held-out test cohort while maintaining segmentation-derived anatomical measurements. These findings suggest that ART-Net may support accelerated brain MRI by improving image fidelity and enabling reliable downstream anatomical analysis.

0.23

Unified Residual Translation for Paired Image Restoration

cs.CV ·2026-11-17 ·Joyanta Jyoti Mondal, Mridul Banik, Ibne Farabi Shihab, Md. Shifatul Ahsan Apurba
similarity 0.67
Abstract · 10 pages, 2 figures

Paired image restoration spans changes in imaging contrast, sensor modality, and spatial resolution. These settings differ in their input channels and target grids, raising the question of how much of the prediction pipeline must be specialized to each task. We present the Unified Residual Translator (URT), which separates fixed channel and scale mapping from learned residual prediction. A deterministic reference uses channel averaging, replication, or bicubic interpolation to match the target dimensions, while a NAFNet encoder-decoder predicts an additive correction from the complete input. Separately trained instances share the prediction rule, $\ell_1$ objective, and optimizer across MRI contrast synthesis, visible-to-infrared translation, SAR-to-optical translation, and real-camera super-resolution. Across six task and scale settings, URT achieves the highest PSNR and SSIM among the evaluated baselines on IXI, SEN1-2, and RealSR $\times3$ and $\times4$. It reaches 30.774dB on IXI and 13.478dB on SEN1-2, with luminance PSNR of 33.596, 28.742, and 27.342dB at the three RealSR scales. On LLVIP, it ranks second in PSNR and SSIM. A study of four spectral alternatives identifies complementary benefits of fitted references and bandwise residual gains. Together, these results support explicit dimensional alignment and learned residual correction as a common formulation for heterogeneous paired imaging tasks.

0.31