One Evaluation, Any Operating Point: Hypernetwork-Amortized MeanFlow for 3D MRI Reconstruction

Ruibo Wang

cs.CV ·submitted 2026-09-15 01:45 UTC · v1

Abstract

Generative priors reconstruct accelerated 3D MRI well but pay heavily at deployment: tens of network evaluations per volume, and protocol-specific hyperparameter tuning. A third hidden cost is the scanner's fixed sampling pattern. We treat the whole operating point as an input. A 3D MeanFlow patch network (a one-step flow model) is fine-tuned end-to-end through a warm-started, five-iteration differentiable conjugate-gradient projection. A small hypernetwork maps the operating point (data-consistency weight, acceleration, and the Cartesian sampling pattern itself) to the network's per-channel modulation. Three findings follow. (i) Learning the acquisition is worth more than any other operating point: on clinical knee data, the learned mask gains up to +2.34 dB over the protocol's variable-density mask. This gain requires the solver: with a feed-forward reconstructor the same learned mask hurts at 4x (-1.7 dB), but with the data-consistency projection it adds +4.6 dB. (ii) One evaluation is highly effective: it beats a 20-step patch-diffusion prior by up to +3.1 dB on brain and +2.9 dB on knee. Three to five evaluations extend the front to +6 dB while using a quarter of the prior's network calls. (iii) Fully sampled targets are optional: trained self-supervised on a split of acquired samples, the reconstructor matches its supervised twin at 4x on real data. Finally, we report what failed and why: subject-adaptive acquisition from measured energy, combining self-supervision with learned acquisition, and amortising the data-consistency weight.

Comment
38 pages (9-page main text plus appendices)

Closest papers

Nearest neighbours by meaning across the whole index.

Beyond Sparsity: Weight Location and Network Context in Pruned MRI Reconstruction

eess.IV cs.CV ·2026-09-25 ·Mohammed Wattad, Tamir Shor, Alexander M. Bronstein
similarity 0.69
Abstract

Pruning reduces the number of weights in magnetic resonance imaging (MRI) reconstruction networks. Equal sparsity, however, can retain weights with different computational roles and different compatibility with the trained network. We study these effects across 120 convolutional U-Net and vision transformer models using controlled edits evaluated before retraining. In U-Net, preserving high-resolution computation improves reconstruction at equal deletion counts across all tested sparsity levels. Equal-operation controls reveal additional sensitivity of the first convolution, which operation count alone cannot explain. In transformers, retained pretrained weight energy correlates with quality within sparsity levels, yet the same masks reverse their reconstruction ranking when the surrounding trained weights change. At 90\% sparsity, matching intermediate output scales largely removes a high-energy-mask penalty while retaining an advantage for the network's original mask. Thus sparsity alone does not characterize reconstruction quality: architecture-specific descriptors are informative, but mask quality can still depend on the surrounding trained network.

0.28

Scalable Unrolled Chains for MRI Reconstruction

cs.CV ·2026-10-24 ·Emiljo Mëhillaj, Ender Konukoglu
publishedcode/data similarity 0.68
Abstract · 23 pages (including supplementary material), 14 figures. Accepted at WACV 2027

Unrolled variational networks achieve state-of-the-art performance for accelerated MRI reconstruction, but standard end-to-end training becomes prohibitively memory intensive as the number and width of cascades increase. We propose a memory-efficient training framework that updates a randomly sampled cascade while retaining supervision from the final reconstruction loss. The error signal is propagated from the end of the chain to the sampled cascade using an activation-light backward pass that avoids storing full chain activations, thereby decoupling training memory from chain length. A time-conditioned network shared across cascades further keeps the parameter count independent of chain length. The backward pass is approximate only through frozen normalization statistics, and a trained exact gradient control shows the approximation leaves reconstruction quality unchanged. The framework remains trainable at chain lengths and cascade widths where standard end-to-end backpropagation exhausts GPU memory. On fastMRI single-coil knee and multi-coil brain reconstruction, our method consistently outperforms other local training approaches. On high-SNR knee slices, our method surpasses E2E-VarNet at $8\times$ and matches it at $4\times$, while on the complete brain validation set it surpasses E2E-VarNet at $8\times$ and achieves comparable performance at $4\times$, with fewer parameters, lower peak memory, and faster per-iteration training. Code is available at https://github.com/emehillaj/scalable-unrolled-mri.

0.50

One Block Is Enough: LoopMR for Accelerated MRI Reconstruction

eess.IV cs.CV ·2026-11-11 ·Yimeng He, Yibin Xie, Yi Zheng, Yifan Gao, Lixia Wang +5 more
code/data similarity 0.66
Abstract · 10 pages, 7 figures, 6 tables. Code: https://github.com/hym97/LoopMR

Deep-learning unrolled networks are the leading approach to accelerated MRI reconstruction. State-of-the-art models such as PromptMR+ learn a distinct block for every cascade, so their size grows with the number of cascades. Sharing one block across iterations avoids adding parameters, but earlier shared-weight models typically used a tiny block and produced worse images than models with distinct weights. Therefore, it remained unclear whether weight sharing itself or the choice of block was the problem. Recent advances in looped transformers, which reuse the same block across layers, show that they can match or outperform their distinct-weight counterparts on several tasks. Motivated by this, we propose LoopMR, which reuses a single Restormer block at every iteration as its core. Besides the current image estimate, the block receives data-consistency inputs and latent images. On four datasets covering the brain (CC359), knee (fastMRI), heart (CMRxRecon2023) and carotid (in-house), LoopMR significantly outperforms E2E-VarNet, PromptMR and PromptMR+ in PSNR and SSIM at every acceleration factor (p < 0.01), with about 1/9 of PromptMR+'s parameters (10.3M versus 92.9M). It also keeps its lead at unseen acceleration factors and on an unseen dataset. With our transformer block, the shared model matches or outperforms its distinct-weight counterpart at 6, 12 and 24 iterations. At a fixed number of iterations, shared transformer blocks match or outperform their distinct-weight versions, while shared CNN blocks perform worse. These results suggest that looping one well-chosen block can outperform stacking distinct cascades in MRI reconstruction, with a fraction of the parameters.

0.22

Prior-Guided Physics-Informed Deep Learning for Fast 4D MRI Reconstruction

cs.CV physics.med-ph ·2026-11-01 ·Mojtaba Safari, Parag J. Parikh, Shansong Wang, Mingzhe Hu, Philip Connell +4 more
similarity 0.65
Abstract

Background and purpose: We propose PGPI4MR (prior-guided, physics-informed 4D MRI reconstruction), a deep learning method that leverages information from other respiratory phases or a setup scan, the first 30 s of the same scan, to improve 4D MRI reconstruction without extra scan time. Materials and methods: PGPI4MR is an unrolled network that reconstructs 16 respiratory phases from 60, 30, or 15 s of data, and single 3D volumes, each from 0.29-0.49 s of data, using a setup-scan image. The networks were trained once, on other volunteers, and were not retrained for new volunteers. We evaluated PGPI4MR on measured k-space from three datasets: free-breathing MR-linac (1.5T) and abdominal (3T) scans, and thigh scans with cuff compression (1.5T). All methods, including comparative models, received identical samples and were scored similarly. Results: In vivo, PGPI4MR had the lowest held-out error for 4D MRI at every scan time, and its 16 phases were ready a median of 7.5-13 s after the scan on the 2 GPUs tested. Coupling the 16 respiratory phases reduced the error at 60 s by 9.1% compared with reconstructing each phase alone. For sub-second MRI, the error at 0.49 s was 15.5% lower than that of the best comparison method, classical reconstruction toward the same prior, and on the faster GPU, every 0.29 s window was acquired and reconstructed within 0.5 s. Without retraining, PGPI4MR matched the best methods on the 3T abdominal scans but not on the thigh scans; after retraining on thigh data, it reduced the held-out error by 6.6% relative to the best comparison method. Conclusion: Prior information allowed PGPI4MR to reconstruct 4D and sub-second MRI more accurately than compressed sensing and a published 4D network, within seconds and without extra scan time. This could support 4D MRI for treatment planning and 3D motion monitoring during MR-guided radiotherapy.

0.21

FIRM: Flow-based Imaging via Regularized Minimization

cs.CV ·2026-09-11 ·Shirin Shoushtari, Edward P. Chandler, Xiao Shi, Ulugbek S. Kamilov
similarity 0.64
Abstract

Flow matching methods for imaging inverse problems typically incorporate measurements through network conditioning or guidance during sampling. Neither approach explicitly applies the forward operator within the learned conditional velocity field. We develop a principled measurement-conditional velocity parameterization that does. For a linear interpolation path, we express the optimal velocity through the posterior mean $E[x_1|x_t, y]$ and show that this mean is the unique minimizer of a variational objective with an explicit data-consistency term. The velocity defined by this minimizer provably transports the source distribution to the measurement-conditioned posterior. This result leads to a forward operator-aware velocity field that is trained end-to-end and requires no separate guidance during sampling. Across five imaging tasks, our method achieves leading reconstruction quality with up to $50\times$ fewer network evaluations than competitive flow-based methods. Varying the number of sampling steps also controls the distortion-perception trade-off without retraining.

0.17

STAIRS: Staging the Inverse Problem via Admissible-Support Scheduling for Unrolled MRI Reconstruction

cs.CV ·2026-11-06 ·Xiangjian Hou, Chang Ni, Chao Qin, Zhiwei Tan, Xin Wang +4 more
similarity 0.63
Abstract

Accelerated magnetic resonance imaging (MRI) forms images from incomplete Fourier measurements, shifting acquisition burden to computational reconstruction. Deep unrolled networks interleave learned regularization and data consistency, yet typically estimate the full unmeasured spectrum at every cascade. We propose STAIRS (Staging the Inverse Problem via Admissible-Support Scheduling), which projects intermediate reconstructions onto nested Fourier supports that expand to the full spectrum and conditions each update on its support transition. Conditional increments of a regularized log-determinant score of training covariance define a normalized spectral coordinate, accounting for dependencies between newly and previously admitted frequencies. Dyadic targets allocate larger coordinate increments to earlier cascades and are mapped to fixed supports before training, enabling coarse-to-fine reconstruction with unchanged sampling masks and data consistency. On fastMRI and Stanford2D, STAIRS improves matched Transformer (HUMUSNet) and convolutional (NAFNet) backbones in single- and multi-coil reconstruction, including radiologist-annotated pathology regions. It also outperforms predictor-based progression with lower parameter overhead and inference latency. Stage-wise analysis shows repeated error correction by projection and lower intermediate reconstruction errors than the backbones alone throughout support expansion. Ablations favor dyadic allocation over uniform expansion for square and line-band supports and over manual front-loading for square windows. Support projection alone improves reconstruction, and transition conditioning strengthens the gain. Cross-dataset evaluation shows improvements for both backbones in both directions. Support allocation thus complements regularizer design in unrolled MRI reconstruction.

0.22

Coarse-to-Fine 3D MRI Reconstruction via Resolution-Agnostic Neural Operators

eess.IV cs.CV ·2026-11-11 ·Jiayun Wang, Ram Daftari, Weijie Gan, Valentin Duruisseaux, Ruibo Wang +3 more
published similarity 0.63
Abstract · NeurIPS 2026

Deep-learning-based 3D MRI reconstruction is limited in practice by the GPU memory and compute cost of full-volume training; 3D acquisitions are thus most often reconstructed by 2D models applied slice-by-slice and then stacked, which ignores through-plane (stacking-axis) structure. We reconstruct in full 3D and ask whether a model can be trained at low resolution (fast and memory-feasible) yet deployed at higher resolution. This coarse-to-fine strategy needs reliable cross-resolution performance, but standard networks are resolution-specific and degrade substantially when evaluated outside the training setting. We therefore use resolution-agnostic neural operators (NOs) and propose KIR-NO (k-space-to-Image Reconstruction Neural Operator), a discretization-agnostic framework for accelerated 3D MRI reconstruction. KIR-NO is trained with full backpropagation on low-resolution volumes and applied zero-shot to higher-resolution volumes at inference. Its core building block is a 3D neural operator based on discrete-continuous convolutions: convolutional filters are parameterized in a continuous basis and sampled at arbitrary voxel resolutions while preserving the local inductive bias of convolution. KIR-NO integrates these learned operators with physics-based consistency: a k-space neural-operator head first refines the undersampled Fourier measurements, and image-space neural-operator cascades then refine the reconstruction through interleaved data-consistency updates. Across 3D knee and brain MRI benchmarks, KIR-NO improves over classical and CNN baselines: it improves over a state-of-the-art 3D CNN by 2.2 dB PSNR at half resolution under 4x acceleration on SKM-TEA, with gains persisting at 8x and 16x. These results show that resolution-agnostic operators make coarse-to-fine 3D MRI reconstruction - cheap low-resolution training with high-resolution deployment - practical across anatomies.

0.27

Joint Supervised and Self-Supervised Training with Acquisition-Robust Techniques for Accelerated 4D Flow MRI Reconstruction

eess.IV cs.CV ·2026-09-29 ·Mengyuan Xue, Bochun Mei
similarity 0.63
Abstract

4D flow MRI measures time-resolved, three-directional blood velocity but requires long acquisition times, and its diagnostic signal is carried by the phase difference \emph{between} velocity encodings, not by image magnitude. Recent work has developed a per-encoding variational network to address image reconstruction in this field. In this work, we incorporate a joint supervised and self-supervised training regime and utilize both magnitude and velocity data during supervision. At the same time, we add multiple acquisition-robust and conditioning strategies based on the acceleration factors. On the CMRx4DFlow~2026 aortic dataset (1.5 and 3T), our model lowers RelErr by $38$--$50\%$ and AngErr by $7.0$--$8.7^\circ$ against a training-matched baseline across $R{=}10$--$50$, improving on every held-out subject at every acceleration. Our model also shows strong generalization ability to transfer on out-of-distribution data by employing the joint training scheme, with an increase of $7.2\%$ in SSIM and decrease of $38\%$ and $31\%$ in AngErr and RelErr respectively.

0.12