CS Paper Radar

Awaken, Then Scale: Tiny Adaptation for MRI Reconstruction

Mohammed Wattad, Tamir Shor, Alexander M. Bronstein

eess.IV cs.CV ·submitted 2026-09-25 13:54 UTC · v1

Abstract

Dormant Awakening (DA) specializes a magnetic resonance imaging (MRI) reconstruction model by fitting a small set of zero weights to one labeled slice. Across fourteen U-shaped convolutional network (U-Net) and vision transformer (ViT) sources, fitting 1,004 or 10,560 weights gives mean peak signal-to-noise ratio (PSNR) gains of .430 and .509 dB. We analyze how scaling the fitted output correction changes evaluation PSNR, then use the calibration correction size to cap changes on new images. The cap bounds changes in root mean squared error (RMSE) relative to the source without an evaluation reference. At 10\% adaptation budget, we compare fixed halving and dynamic capping for DA, unrestricted sparse adaptation and low-rank adaptation (LoRA). The controls increase both measured calibration-evaluation correlations across all six tested architecture-adapter settings. Experiments concern one constructed fastMRI-to-M4Raw shift with fixed source checkpoints and participant panels.

Closest papers

Nearest neighbours by meaning across the whole index.

Beyond Sparsity: Weight Location and Network Context in Pruned MRI Reconstruction

eess.IV cs.CV ·2026-09-25 ·Mohammed Wattad, Tamir Shor, Alexander M. Bronstein
similarity 0.69
Abstract

Pruning reduces the number of weights in magnetic resonance imaging (MRI) reconstruction networks. Equal sparsity, however, can retain weights with different computational roles and different compatibility with the trained network. We study these effects across 120 convolutional U-Net and vision transformer models using controlled edits evaluated before retraining. In U-Net, preserving high-resolution computation improves reconstruction at equal deletion counts across all tested sparsity levels. Equal-operation controls reveal additional sensitivity of the first convolution, which operation count alone cannot explain. In transformers, retained pretrained weight energy correlates with quality within sparsity levels, yet the same masks reverse their reconstruction ranking when the surrounding trained weights change. At 90\% sparsity, matching intermediate output scales largely removes a high-energy-mask penalty while retaining an advantage for the network's original mask. Thus sparsity alone does not characterize reconstruction quality: architecture-specific descriptors are informative, but mask quality can still depend on the surrounding trained network.

0.28

Unified Residual Translation for Paired Image Restoration

cs.CV ·2026-11-17 ·Joyanta Jyoti Mondal, Mridul Banik, Ibne Farabi Shihab, Md. Shifatul Ahsan Apurba
similarity 0.68
Abstract · 10 pages, 2 figures

Paired image restoration spans changes in imaging contrast, sensor modality, and spatial resolution. These settings differ in their input channels and target grids, raising the question of how much of the prediction pipeline must be specialized to each task. We present the Unified Residual Translator (URT), which separates fixed channel and scale mapping from learned residual prediction. A deterministic reference uses channel averaging, replication, or bicubic interpolation to match the target dimensions, while a NAFNet encoder-decoder predicts an additive correction from the complete input. Separately trained instances share the prediction rule, $\ell_1$ objective, and optimizer across MRI contrast synthesis, visible-to-infrared translation, SAR-to-optical translation, and real-camera super-resolution. Across six task and scale settings, URT achieves the highest PSNR and SSIM among the evaluated baselines on IXI, SEN1-2, and RealSR $\times3$ and $\times4$. It reaches 30.774dB on IXI and 13.478dB on SEN1-2, with luminance PSNR of 33.596, 28.742, and 27.342dB at the three RealSR scales. On LLVIP, it ranks second in PSNR and SSIM. A study of four spectral alternatives identifies complementary benefits of fitted references and bandwise residual gains. Together, these results support explicit dimensional alignment and learned residual correction as a common formulation for heterogeneous paired imaging tasks.

0.31

Beyond Training from Scratch: Foundation Models for Data-Efficient and Generalizable Cardiac MRI Reconstruction

cs.CV ·2026-10-06 ·Anam Hashmi, Mayug Maniparambil, Julia Dietlmeier, Kathleen M. Curran, Noel E. O'Connor
publishedcode/data similarity 0.66
Abstract · Accepted at ECCVW 2026

Cardiac magnetic resonance imaging reconstruction aims to recover high-quality images from undersampled acquisitions, enabling faster scans while preserving diagnostic fidelity. Recent reconstruction methods are typically trained from scratch and often require large amounts of task-specific data, limiting their robustness under data scarcity and distribution shifts. In this work, we investigate whether pretrained vision foundation models can serve as effective priors for accelerated cardiac MRI reconstruction. We propose a reconstruction framework that integrates frozen and parameter-efficiently adapted visual encoders, including CLIP, BiomedCLIP, and DINOv2, within a transformer-based reconstruction architecture. Extensive experiments on the CMRxRecon2023 and CMRxRecon2024 benchmarks demonstrate that pretrained representations consistently outperform a transformer trained from scratch across multiple acceleration factors. We further evaluate performance under limited supervision and cross-dataset transfer, showing that foundation models provide superior data efficiency and generalization. While frozen representations are particularly effective in extreme low-data regimes, Low-Rank Adaptation (LoRA) yields additional gains when moderate amounts of training data are available. Among the evaluated backbones, DINOv2 achieves the strongest overall performance. These findings highlight the potential of vision foundation models as robust and transferable priors for cardiac MRI reconstruction.

0.31

One Shared LoRA Weight for MRI Reconstruction across Acceleration Factors

cs.CV cs.LG ·2026-09-06 ·Zhiwei Zhao, Weikang Gong, Zhongnian Li, Xinzheng Xu
similarity 0.64
Abstract

Accelerated MRI reconstruction recovers images from undersampled k-space. However, different acceleration factors produce distinct artifact patterns. Existing methods often train separate models for each factor, leading to poor cross-factor generalization and high training and storage costs. We propose Shared LoRA, a parameter-efficient framework that freezes the pretrained SHFormer backbone and trains a single shared set of LoRA adapters together with a lightweight gating network. During training, undersampled inputs are generated by randomly sampling acceleration factors and their corresponding sampling masks, enabling the shared adapters to learn reconstruction knowledge across factors. Given the acceleration factor, GateNet generates layer-wise coefficients to dynamically modulate the residual strength of each adapter. Experiments show that Shared LoRA achieves the best or competitive PSNR and SSIM across acceleration factors, while its trainable parameters account for only about 5.3% of the total model parameters. Its performance at lower acceleration factors remains largely unaffected as the jointly trained factor set expands, and it generalizes stably to unseen neighboring factors.

0.31

Anatomically Faithful Artifact Suppression in SENSE Accelerated Brain MRI

eess.IV cs.CV ·2026-09-18 ·Changjing Chai, Bin Huang, Libo Xu, Jian Zhou, Boyang Pan +3 more
similarity 0.62
Abstract · 18 pages of main text, 2 pages of appendix, 6 figures, and 6 tables (including 2 appendix tables)

Background: Four-fold accelerated sensitivity encoding (SENSE4) can shorten brain MRI acquisition time but may amplify noise and result in residual aliasing artifacts after conventional reconstruction. Purpose: To evaluate whether an image-domain refinement framework can improve the quality of SENSE4 brain MRI while preserving anatomical information for quantitative measurements. Methods: In this prospective paired study, 80 participants underwent fully sampled and four-fold accelerated SENSE T1-weighted MRI. We developed an Anatomy-aware Residual Attention Network (ART-Net) to refine accelerated reconstructions through generalized self-attention and correlation-based residual artifact regularization. Participant-level splitting yielded training, validation, and independent test cohort (45/5/30 participants). The independent test cohort underwent quantitative, segmentation-based, and blinded radiologist assessments of image quality and anatomical preservation. Results: ART-Net demonstrated highly competitive reconstruction performance, achieving the highest peak signal-to-noise ratio (31.03 +/- 2.88 dB) and structural similarity index (0.963 +/- 0.022) among evaluated methods. It also demonstrated improved anatomical fidelity, with numerically highest Dice coefficients for medial temporal structures relevant to atrophy assessment (0.8824 +/- 0.0827) and whole-brain regions (0.8857 +/- 0.0885). Moreover, ART-Net improved gradient fidelity, regional contrast preservation, and radiologist-rated structural quality. Conclusion: ART-Net improved agreement between SENSE4 and fully sampled T1-weighted images in a single-center, held-out test cohort while maintaining segmentation-derived anatomical measurements. These findings suggest that ART-Net may support accelerated brain MRI by improving image fidelity and enabling reliable downstream anatomical analysis.

0.23

When Online Adaptation Hurts: Parameter-Frozen Test-Time Ensembling for Continual Medical Image Segmentation

cs.CV ·2026-09-18 ·Ruijie Huang
similarity 0.61
Abstract · 7 pages, 2 figures

Medical image segmenters often get worse when sites, scanner vendors, or protocols change. Continual test-time adaptation (CTTA) addresses this problem without target labels, but it can be impossible to update a model on a non-stationary stream and can lead to a lot of errors. We examine a more reasonable and meaningful alternative: parameter-frozen inference enhancement(PIE). We use a source-trained segmenter that learns about anatomy-preserving scale and flip views, maps their predictions back to the native location, and averages the probabilities. We do not modify the weights of the model or the normalization statistics. On a cardiac MRI stream from M\&Ms, which is trained on vendor A and evaluated sequentially on vendors B, C, and D, PIE has 0.7786 mean Dice, compared to 0.7680 for source-only inference and 0.7388--0.7416 for five other online-adaptation baselines. The controlled ablations show that performance saturates at 28 views, and confidence weighting, class-prior correction, connected-component filtering, morphological refinement, and inter-slice smoothing have no effect or cause negative transfer. Qualitative results on cardiac MRI and fundus images are also consistent with the frozen ensemble keeping thinner and nested anatomical structures. These results provide a strong, stable baseline for medical CTTA and expose an important failure mode: adaptation and handcrafted refinement can be less reliable than carefully designed inference.

0.20

Reduce, Then Encode: Multiscale Volumetric Reduction for 2D Foundation Models in Brain MRI

cs.CV ·2026-09-28 ·Dexuan Ding, Yuankai Qi, Bogong Wang, Luping Zhou, Amin Beheshti
similarity 0.61
Abstract

Pretrained 2D foundation models offer a practical alternative to dedicated 3D pretraining for brain structural magnetic resonance imaging (sMRI), but their use on volumetric data requires bridging the mismatch between a 2D encoder and a 3D volume input. Existing methods typically encode slices independently and integrate their features afterwards. We introduce Multiscale Volumetric Reduction (MVR), a reduce-then-encode approach that compresses each anatomical view from (D) slices into (M << D) complementary 2D components before foundation-model encoding. MVR combines an uncentered-PCA base component derived from the original through-plane intensities with residual detail components constructed from multiscale spatial descriptors. The reduction is estimated from the training volumes without diagnostic labels or gradient-based optimization and remains fixed thereafter. The resulting components are independently processed by a shared frozen 2D foundation model and concatenated for linear probing. Under this frozen-encoder setting, MVR achieves strong overall performance across ADNI, OASIS, and ABIDE relative to the evaluated 2D-to-3D adaptation methods and simple input-reduction baselines, while also generalizing strongly from ADNI to AIBL.

0.13

BaT-SAM: Introducing Inductive Bias into SAM via a Mixture of Convolutional Experts for Brain Tumor Segmentation

cs.CV ·2026-10-11 ·Sumiaya Jannat, Md Mahedi Hasan, Md Shamimul Islam, Md Nur Hossain
benchmark similarity 0.60
Abstract

Accurate brain tumor segmentation from magnetic resonance imaging (MRI) is essential for diagnosis and treatment planning; however, manual delineation is labor-intensive and time-consuming. Existing approaches are either task-specific with limited generalization or rely on user-provided prompts during inference. We present BaT-SAM, a parameter-efficient adaptation framework that enables fully automatic brain tumor segmentation with the Segment Anything Model (SAM). BaT-SAM injects local inductive bias into SAM's frozen Vision Transformer (ViT) encoder via Conv-LoRA, where image features are processed by a sparsely gated mixture of multi-scale convolutional experts. This design compensates for the limited translation-equivariant inductive bias of vanilla ViTs while fine-tuning fewer than 5M parameters (less than 1% of the full model). To remove the need for user prompts, we further introduce a lightweight self-prompting box regressor that is jointly optimized with the adapter using scheduled sampling and predicts tumor locations directly from image embeddings. On the BRISC2025 benchmark, BaT-SAM achieves a weighted mean IoU of 0.832 while outperforming state-of-the-art benchmarks. It further demonstrates strong cross-dataset generalization, achieving Dice scores of 0.702 on Figshare and 0.784 on the LGG MRI Segmentation dataset.

0.07