CS Paper Radar

One Shared LoRA Weight for MRI Reconstruction across Acceleration Factors

Zhiwei Zhao, Weikang Gong, Zhongnian Li, Xinzheng Xu

cs.CV cs.LG ·submitted 2026-09-06 02:23 UTC · v1

Abstract

Accelerated MRI reconstruction recovers images from undersampled k-space. However, different acceleration factors produce distinct artifact patterns. Existing methods often train separate models for each factor, leading to poor cross-factor generalization and high training and storage costs. We propose Shared LoRA, a parameter-efficient framework that freezes the pretrained SHFormer backbone and trains a single shared set of LoRA adapters together with a lightweight gating network. During training, undersampled inputs are generated by randomly sampling acceleration factors and their corresponding sampling masks, enabling the shared adapters to learn reconstruction knowledge across factors. Given the acceleration factor, GateNet generates layer-wise coefficients to dynamically modulate the residual strength of each adapter. Experiments show that Shared LoRA achieves the best or competitive PSNR and SSIM across acceleration factors, while its trainable parameters account for only about 5.3% of the total model parameters. Its performance at lower acceleration factors remains largely unaffected as the jointly trained factor set expands, and it generalizes stably to unseen neighboring factors.

Closest papers

Nearest neighbours by meaning across the whole index.

Beyond Training from Scratch: Foundation Models for Data-Efficient and Generalizable Cardiac MRI Reconstruction

cs.CV ·2026-10-06 ·Anam Hashmi, Mayug Maniparambil, Julia Dietlmeier, Kathleen M. Curran, Noel E. O'Connor
publishedcode/data similarity 0.74
Abstract · Accepted at ECCVW 2026

Cardiac magnetic resonance imaging reconstruction aims to recover high-quality images from undersampled acquisitions, enabling faster scans while preserving diagnostic fidelity. Recent reconstruction methods are typically trained from scratch and often require large amounts of task-specific data, limiting their robustness under data scarcity and distribution shifts. In this work, we investigate whether pretrained vision foundation models can serve as effective priors for accelerated cardiac MRI reconstruction. We propose a reconstruction framework that integrates frozen and parameter-efficiently adapted visual encoders, including CLIP, BiomedCLIP, and DINOv2, within a transformer-based reconstruction architecture. Extensive experiments on the CMRxRecon2023 and CMRxRecon2024 benchmarks demonstrate that pretrained representations consistently outperform a transformer trained from scratch across multiple acceleration factors. We further evaluate performance under limited supervision and cross-dataset transfer, showing that foundation models provide superior data efficiency and generalization. While frozen representations are particularly effective in extreme low-data regimes, Low-Rank Adaptation (LoRA) yields additional gains when moderate amounts of training data are available. Among the evaluated backbones, DINOv2 achieves the strongest overall performance. These findings highlight the potential of vision foundation models as robust and transferable priors for cardiac MRI reconstruction.

0.31

One Block Is Enough: LoopMR for Accelerated MRI Reconstruction

eess.IV cs.CV ·2026-11-11 ·Yimeng He, Yibin Xie, Yi Zheng, Yifan Gao, Lixia Wang +5 more
code/data similarity 0.69
Abstract · 10 pages, 7 figures, 6 tables. Code: https://github.com/hym97/LoopMR

Deep-learning unrolled networks are the leading approach to accelerated MRI reconstruction. State-of-the-art models such as PromptMR+ learn a distinct block for every cascade, so their size grows with the number of cascades. Sharing one block across iterations avoids adding parameters, but earlier shared-weight models typically used a tiny block and produced worse images than models with distinct weights. Therefore, it remained unclear whether weight sharing itself or the choice of block was the problem. Recent advances in looped transformers, which reuse the same block across layers, show that they can match or outperform their distinct-weight counterparts on several tasks. Motivated by this, we propose LoopMR, which reuses a single Restormer block at every iteration as its core. Besides the current image estimate, the block receives data-consistency inputs and latent images. On four datasets covering the brain (CC359), knee (fastMRI), heart (CMRxRecon2023) and carotid (in-house), LoopMR significantly outperforms E2E-VarNet, PromptMR and PromptMR+ in PSNR and SSIM at every acceleration factor (p < 0.01), with about 1/9 of PromptMR+'s parameters (10.3M versus 92.9M). It also keeps its lead at unseen acceleration factors and on an unseen dataset. With our transformer block, the shared model matches or outperforms its distinct-weight counterpart at 6, 12 and 24 iterations. At a fixed number of iterations, shared transformer blocks match or outperform their distinct-weight versions, while shared CNN blocks perform worse. These results suggest that looping one well-chosen block can outperform stacking distinct cascades in MRI reconstruction, with a fraction of the parameters.

0.22

Scalable Unrolled Chains for MRI Reconstruction

cs.CV ·2026-10-24 ·Emiljo Mëhillaj, Ender Konukoglu
publishedcode/data similarity 0.69
Abstract · 23 pages (including supplementary material), 14 figures. Accepted at WACV 2027

Unrolled variational networks achieve state-of-the-art performance for accelerated MRI reconstruction, but standard end-to-end training becomes prohibitively memory intensive as the number and width of cascades increase. We propose a memory-efficient training framework that updates a randomly sampled cascade while retaining supervision from the final reconstruction loss. The error signal is propagated from the end of the chain to the sampled cascade using an activation-light backward pass that avoids storing full chain activations, thereby decoupling training memory from chain length. A time-conditioned network shared across cascades further keeps the parameter count independent of chain length. The backward pass is approximate only through frozen normalization statistics, and a trained exact gradient control shows the approximation leaves reconstruction quality unchanged. The framework remains trainable at chain lengths and cascade widths where standard end-to-end backpropagation exhausts GPU memory. On fastMRI single-coil knee and multi-coil brain reconstruction, our method consistently outperforms other local training approaches. On high-SNR knee slices, our method surpasses E2E-VarNet at $8\times$ and matches it at $4\times$, while on the complete brain validation set it surpasses E2E-VarNet at $8\times$ and achieves comparable performance at $4\times$, with fewer parameters, lower peak memory, and faster per-iteration training. Code is available at https://github.com/emehillaj/scalable-unrolled-mri.

0.50

Awaken, Then Scale: Tiny Adaptation for MRI Reconstruction

eess.IV cs.CV ·2026-09-25 ·Mohammed Wattad, Tamir Shor, Alexander M. Bronstein
similarity 0.64
Abstract

Dormant Awakening (DA) specializes a magnetic resonance imaging (MRI) reconstruction model by fitting a small set of zero weights to one labeled slice. Across fourteen U-shaped convolutional network (U-Net) and vision transformer (ViT) sources, fitting 1,004 or 10,560 weights gives mean peak signal-to-noise ratio (PSNR) gains of .430 and .509 dB. We analyze how scaling the fitted output correction changes evaluation PSNR, then use the calibration correction size to cap changes on new images. The cap bounds changes in root mean squared error (RMSE) relative to the source without an evaluation reference. At 10\% adaptation budget, we compare fixed halving and dynamic capping for DA, unrestricted sparse adaptation and low-rank adaptation (LoRA). The controls increase both measured calibration-evaluation correlations across all six tested architecture-adapter settings. Experiments concern one constructed fastMRI-to-M4Raw shift with fixed source checkpoints and participant panels.

0.19

Beyond Sparsity: Weight Location and Network Context in Pruned MRI Reconstruction

eess.IV cs.CV ·2026-09-25 ·Mohammed Wattad, Tamir Shor, Alexander M. Bronstein
similarity 0.64
Abstract

Pruning reduces the number of weights in magnetic resonance imaging (MRI) reconstruction networks. Equal sparsity, however, can retain weights with different computational roles and different compatibility with the trained network. We study these effects across 120 convolutional U-Net and vision transformer models using controlled edits evaluated before retraining. In U-Net, preserving high-resolution computation improves reconstruction at equal deletion counts across all tested sparsity levels. Equal-operation controls reveal additional sensitivity of the first convolution, which operation count alone cannot explain. In transformers, retained pretrained weight energy correlates with quality within sparsity levels, yet the same masks reverse their reconstruction ranking when the surrounding trained weights change. At 90\% sparsity, matching intermediate output scales largely removes a high-energy-mask penalty while retaining an advantage for the network's original mask. Thus sparsity alone does not characterize reconstruction quality: architecture-specific descriptors are informative, but mask quality can still depend on the surrounding trained network.

0.28

STAIRS: Staging the Inverse Problem via Admissible-Support Scheduling for Unrolled MRI Reconstruction

cs.CV ·2026-11-06 ·Xiangjian Hou, Chang Ni, Chao Qin, Zhiwei Tan, Xin Wang +4 more
similarity 0.64
Abstract

Accelerated magnetic resonance imaging (MRI) forms images from incomplete Fourier measurements, shifting acquisition burden to computational reconstruction. Deep unrolled networks interleave learned regularization and data consistency, yet typically estimate the full unmeasured spectrum at every cascade. We propose STAIRS (Staging the Inverse Problem via Admissible-Support Scheduling), which projects intermediate reconstructions onto nested Fourier supports that expand to the full spectrum and conditions each update on its support transition. Conditional increments of a regularized log-determinant score of training covariance define a normalized spectral coordinate, accounting for dependencies between newly and previously admitted frequencies. Dyadic targets allocate larger coordinate increments to earlier cascades and are mapped to fixed supports before training, enabling coarse-to-fine reconstruction with unchanged sampling masks and data consistency. On fastMRI and Stanford2D, STAIRS improves matched Transformer (HUMUSNet) and convolutional (NAFNet) backbones in single- and multi-coil reconstruction, including radiologist-annotated pathology regions. It also outperforms predictor-based progression with lower parameter overhead and inference latency. Stage-wise analysis shows repeated error correction by projection and lower intermediate reconstruction errors than the backbones alone throughout support expansion. Ablations favor dyadic allocation over uniform expansion for square and line-band supports and over manual front-loading for square windows. Support projection alone improves reconstruction, and transition conditioning strengthens the gain. Cross-dataset evaluation shows improvements for both backbones in both directions. Support allocation thus complements regularizer design in unrolled MRI reconstruction.

0.22

PE-CSNet: An equivariant network architecture with learnable patch-based sparse representation

cs.CV ·2026-08-11 ·Kai Li, Haitao Long, Bo Zhang, Haiwen Zhang, Zhi Zhou
similarity 0.62
Abstract · 35 pages, 10 figures. Under review

Compressive sensing (CS) enables accurate signal reconstruction from sparse measurements and is widely applied in medical imaging, remote sensing, and image compression. However, designing an effective, task-specific sparse transform and the corresponding optimization procedure for high-quality CS remains challenging. This process typically requires expert domain knowledge and laborious parameter tuning. To address this issue, we present a Patch-based Equivariant deep unrolling architecture, termed PE-CSNet, for accurate CS recovery. While traditional CS methods generally use predefined patch-based transform sparsity, we generalize this idea by incorporating learnable transform sparsity that adapts to the specific CS task through an optimization-driven process. Specifically, we first establish a generalized patch-based CS model, which we solve via a block coordinate descent (BCD) algorithm. The BCD solver is then unrolled into a deep neural network, where all parameters of both the CS model and solver are learned through end-to-end training. To improve data efficiency, we introduce a stochastic equivariant training strategy that exploits the patch-wise structure of the network, enabling PE-CSNet to learn effectively even from limited data. We further provide a simpler, parameter-shared version of PE-CSNet and briefly discuss its convergence as an iterative solver. For practical applications, the network uses stage-specific (non-shared) parameters to enhance its expressive power and thereby improve its performance. On the tasks of CS magnetic resonance imaging (CS-MRI) and CS coded diffraction patterns (CS-CDP), PE-CSNet achieves state-of-the-art accuracy with fast computational speed, outperforming traditional methods and existing deep unrolling methods.

0.12

FM-Recon: Exploring Foundation Model Features for Accelerated Cardiac Cine MRI Reconstruction

cs.CV cs.AI ·2026-11-16 ·Donghang Lyu, Marius Staring, Ruochen Gao, Jochen Keupp, Hildo J. Lamb +1 more
similarity 0.62
Abstract

Foundation models have demonstrated strong feature extraction capabilities across various medical imaging tasks, yet their potential for MRI reconstruction remains largely unexplored, particularly within unrolled reconstruction networks and under artifact-corrupted inputs. In this work, we explore whether and how features from pretrained foundation models can benefit accelerated cardiac cine MRI reconstruction. To this end, we propose FM-Recon, a framework that refines and integrates extracted features from frozen image encoder of foundation models into an unrolled reconstruction network. Through extensive experiments on the CMRxRecon2023 dataset, we systematically evaluate foundation model features across different reconstruction settings. Our results show that foundation models can extract informative representations from artifact-corrupted inputs and improve reconstruction performance, particularly at moderate acceleration factors. These findings demonstrate the potential of foundation model features for accelerated MRI reconstruction and provide insights into their effective integration into unrolled reconstruction networks.

0.07