CS Paper Radar

Consistency Models for Fast MRI Reconstruction Using Regularization by Denoising

Merve Gülle, Junno Yun, Yaşar Utku Alçalar, Mehmet Akçakaya

eess.IV cs.AIcs.CVcs.LGphysics.med-ph ·submitted 2026-08-20 20:49 UTC · v1
code/data

Abstract

Diffusion models (DMs) have emerged as powerful generative priors for MRI reconstruction with promising results. Yet DM-based methods require extensive iterative refinement, limiting their practical deployment. Consistency models (CMs) provide a compelling alternative, aiming to map out the diffusion trajectory in a single pass, enabling faster generation. In this work, we propose CM-RED, a novel MRI reconstruction method that integrates a pretrained CM into the regularization by denoising (RED) scheme. Our method builds on accelerated proximal gradient RED (RED-APG), and further incorporates controlled noise injection during the update steps to enhance generative diversity and accelerate convergence. Extensive experiments on the fastMRI knee and brain datasets demonstrate that CM-RED achieves high-quality reconstructions across multiple anatomies, contrast weights, acceleration factors, and undersampling patterns, using only 4 network function evaluations (NFEs). The proposed method consistently outperforms existing DM- and CM-based approaches in both quantitative metrics and visual fidelity, and exhibits strong robustness to hyperparameter variations, highlighting CM-RED as an efficient and effective generative framework for accelerated MRI reconstruction. The source code and pretrained models are publicly available at https://github.com/MerveGulle/CM-RED.

Closest papers

Nearest neighbours by meaning across the whole index.

D-MOD: Diffusion mode estimation for accelerated MRI

cs.LG ·2026-10-29 ·Md Kawsar Ahmed, Mathews Jacob
theory similarity 0.74
Abstract

Diffusion models are powerful priors for accelerated MRI reconstruction, but most current methods are posterior samplers, which return a random draw from the posterior. A reproducible and high-quality reconstruction often requires averaging many samples, resulting in a high computational cost. We introduce D-MOD, a fast algorithm that instead provides a posterior mode. It uses a minorize-maximize algorithm on a lower bound of the smoothed log-posterior, which provably increases the objective. Each iteration draws S noisy samples of the current estimate at the current noise level, denoises them with a pretrained diffusion model, and combines their average with the measured k-space through a conjugate-gradient (CG) solve. We anneal the noise levels, as the distance between the bound and its target decays quadratically with noise. On fastMRI brain (T1, T2, FLAIR), a single D-MOD reconstruction exceeds, in PSNR, the 10-sample finite-MMSE estimates of DPS, DAPS and SNORE-P and stays within 0.31 dB of the strongest baselines (DiffPIR, DDS). This approach thus provides a fast deterministic reconstruction algorithm (11-73 times faster than MMSE estimates), which is useful in a clinical setting.

0.36

FlowMoDL: Model-Based Deep Learning with Conjugate-Gradient Data Consistency for Highly Accelerated 4D Flow MRI Reconstruction

cs.CV cs.LG ·2026-08-26 ·Tristan Gottwald, Michelle Bruch, Mubashir-Ul Hassan, Fatma Alickovic, Milan Kloiber +4 more
similarity 0.74
Abstract

We present FlowMoDL, an unrolled neural network for highly accelerated 4D flow MRI reconstruction that directly optimizes for both anatomical magnitude and phase-derived velocity accuracy. Building on the MoDL framework, FlowMoDL alternates a learned (3+1)D spatiotemporal denoiser with conjugate-gradient data-consistency updates based on the SENSE forward model. A novel dual-pathway conditioning scheme adapts the denoiser features and data-consistency weighting, enabling a single model to handle varying acceleration factors ($10\times$ to $50\times$). To ensure physiological accuracy, the network is trained using a deep-supervision composite loss that explicitly penalizes velocity magnitude and angular errors, stabilized by a curriculum schedule. We evaluate FlowMoDL on the multi-center CMRx4DFlow dataset against classical and deep-learning baselines (CG-SENSE, MoDL, FlowVN, and FlowMRI-Net). A key advantage of FlowMoDL is its superior gradient step efficiency. When evaluated under an equivalent, limited budget of gradient steps, competing flow-specific networks degrade significantly. In contrast, FlowMoDL robustly converges and strictly outperforms all competitors across all acceleration factors in magnitude SSIM, nRMSE, relative velocity error, and angular error, successfully recovering sharp structural details and temporally coherent velocity fields.

0.09

Scalable Unrolled Chains for MRI Reconstruction

cs.CV ·2026-10-24 ·Emiljo Mëhillaj, Ender Konukoglu
publishedcode/data similarity 0.72
Abstract · 23 pages (including supplementary material), 14 figures. Accepted at WACV 2027

Unrolled variational networks achieve state-of-the-art performance for accelerated MRI reconstruction, but standard end-to-end training becomes prohibitively memory intensive as the number and width of cascades increase. We propose a memory-efficient training framework that updates a randomly sampled cascade while retaining supervision from the final reconstruction loss. The error signal is propagated from the end of the chain to the sampled cascade using an activation-light backward pass that avoids storing full chain activations, thereby decoupling training memory from chain length. A time-conditioned network shared across cascades further keeps the parameter count independent of chain length. The backward pass is approximate only through frozen normalization statistics, and a trained exact gradient control shows the approximation leaves reconstruction quality unchanged. The framework remains trainable at chain lengths and cascade widths where standard end-to-end backpropagation exhausts GPU memory. On fastMRI single-coil knee and multi-coil brain reconstruction, our method consistently outperforms other local training approaches. On high-SNR knee slices, our method surpasses E2E-VarNet at $8\times$ and matches it at $4\times$, while on the complete brain validation set it surpasses E2E-VarNet at $8\times$ and achieves comparable performance at $4\times$, with fewer parameters, lower peak memory, and faster per-iteration training. Code is available at https://github.com/emehillaj/scalable-unrolled-mri.

0.50

High-Resolution Quantitative MRI Using Contrast-Domain Multiscale Energy (MuSE) Regularization

eess.IV ·2026-11-03 ·Rushdi Rusho, Jyothi Rikhab Chand, Steve R. Kecskemeti, James H. Holmes, Mathews Jacob
similarity 0.72
Abstract · 5 pages, 3 figures

Quantitative MRI methods can offer tissue parameter maps (e.g. T1) that are comparable across scanners, sessions and subjects, together with multiple contrast-weighted images from a single scan. However, most data are acquired at 1 mm, which limits their use in neurodegenerative diseases that affect fine brain structures. We introduce, to our knowledge, the first diffusion-model-based reconstruction for quantitative MRI at 0.5 mm isotropic resolution from scans of less than 5 minutes, which has eightfold smaller voxel volume than clinical protocols. The key idea is to apply the prior to the synthesized contrast images rather than to the subspace coefficients. The prior is then independent of the temporal basis and the sequence, which improves generalization and allows a 2-D multiscale energy (MuSE) model trained on grayscale CelebA face images to be used without any MRI training data. The explicit energy makes reconstruction MAP estimation by a step-size-free majorize-minimize algorithm that regularizes a rotating subset of contrasts along different axes, which makes 3-D multi-contrast reconstruction tractable. For 3-D radial MPnRAGE at 7 T in 4.3 min, MuSE reduced the phantom NRMSE from 0.133 (CG-SENSE) and 0.091 (L1-wavelet) to 0.074 and the WM T1 interquartile range from 117 and 47 ms to 38 ms, and it was demonstrated in vivo at 7 T.

0.24

3D Diffusion Models for Medical Imaging

cs.CV ·2026-10-19 ·Frank-Peter Schilling, Daniel Barco, Philipp Denzel, Marc Stadelmann
publishedsurvey similarity 0.71
Abstract · 27 pages, accepted for publication in Informatics in Medicine Unlocked

Generative deep learning methods such as Variational Autoencoders, Generative Adversarial Networks or Diffusion Models have achieved remarkable results in image synthesis. In particular, Diffusion Models have demonstrated superior image fidelity and sample diversity compared to other approaches on standard benchmarks, while also offering more flexible training dynamics as evidenced both in natural image domains and in medical applications. In medical imaging including Computed Tomography, Magnetic Resonance Imaging or Positron Emission Tomography, such models have various important use-cases including data augmentation, domain transfer, image reconstruction, inpainting, image augmentation and artifact correction. Further, generated images can be conditioned on patient characteristics, medical reports, segmentation masks or other images. Specific challenges arise due to the 3D volumetric nature of medical images, which translate to substantial demands in terms of memory, compute, and training data. This article provides a comparative overview of 3D Diffusion Models which have been developed for medical images, with a focus on current performance, limitations, and an outlook for future work.

0.23

Cascaded Posterior Sampling With Diffusion Priors for highly Accelerated MRI

eess.IV ·2026-10-25 ·Jyothi Rikhab Chand, Sahil Murtaza, Patrick Nicholas Nowak, Mathews Jacob
similarity 0.71
Abstract

Diffusion models are powerful priors for inverse problems, including accelerated MRI. However, modeling the distribution of high-resolution images requires large networks with high computational cost. We propose a posterior sampling framework that uses cascaded diffusion models as multiscale priors. Conditioned on a coarse image, the distribution of fine-scale detail is local and well conditioned, and it can therefore be captured by a small network. Similarly, a small unconditional network is sufficient to represent low-resolution images, and it is used to recover the coarse image from the k-space center. This estimate then conditions the high-resolution prior, which is combined with all measurements to recover the final image. Both priors are trained on images alone, so they apply to any sampling pattern, and data consistency remains linear at every scale. In multi-coil brain MRI, the proposed method improves on the best single-scale diffusion baseline by 4-6 dB in PSNR at 15x acceleration, while each of its separately trained networks is about 10x smaller. The gain grows as the problem becomes more ill-posed, and ablations show that it arises from informative low-resolution conditioning.

0.06

Learning spatially varying regularisation parameters of low regularity for image reconstruction

eess.IV cs.CVmath.OC ·2026-08-25 ·Kostas Papafitsoros, Luca Calatroni, Andreas Kofler
similarity 0.69
Abstract

In this chapter, we review and discuss the regularity properties of spatially adaptive regularisation weight functions used in variational image reconstruction. Incorporating such weights into classical model-based regularisers, such as Total Variation (TV) and Total Generalised Variation (TGV), allows the regularisation strength to vary across the image and adapt to local image content. When appropriately estimated, these weights can thus significantly improve edge and detail preservation in the reconstructions. We review the existing theoretical literature on this topic for different regularity classes, including constant, continuous, and piecewise constant functions. Our discussion is motivated by recent work on hybrid image reconstruction methods that combine model-based regularisation with deep neural networks to learn highly adaptive regularisation weights. In particular, we discuss how the structural properties of these weights influence the reconstruction from both theoretical and practical perspectives. Through representative examples in image denoising and magnetic resonance imaging (MRI) reconstruction, we demonstrate that the learned weights are often of low regularity and can adapt not only to the image structure but also to the specific noise realisation. We conclude by highlighting several directions for future research on this topic.

0.46

Beyond Sparsity: Weight Location and Network Context in Pruned MRI Reconstruction

eess.IV cs.CV ·2026-09-25 ·Mohammed Wattad, Tamir Shor, Alexander M. Bronstein
similarity 0.69
Abstract

Pruning reduces the number of weights in magnetic resonance imaging (MRI) reconstruction networks. Equal sparsity, however, can retain weights with different computational roles and different compatibility with the trained network. We study these effects across 120 convolutional U-Net and vision transformer models using controlled edits evaluated before retraining. In U-Net, preserving high-resolution computation improves reconstruction at equal deletion counts across all tested sparsity levels. Equal-operation controls reveal additional sensitivity of the first convolution, which operation count alone cannot explain. In transformers, retained pretrained weight energy correlates with quality within sparsity levels, yet the same masks reverse their reconstruction ranking when the surrounding trained weights change. At 90\% sparsity, matching intermediate output scales largely removes a high-energy-mask penalty while retaining an advantage for the network's original mask. Thus sparsity alone does not characterize reconstruction quality: architecture-specific descriptors are informative, but mask quality can still depend on the surrounding trained network.

0.28