CS Paper Radar

High-Resolution Quantitative MRI Using Contrast-Domain Multiscale Energy (MuSE) Regularization

Rushdi Rusho, Jyothi Rikhab Chand, Steve R. Kecskemeti, James H. Holmes, Mathews Jacob

eess.IV ·submitted 2026-11-03 16:14 UTC · v1

Abstract

Quantitative MRI methods can offer tissue parameter maps (e.g. T1) that are comparable across scanners, sessions and subjects, together with multiple contrast-weighted images from a single scan. However, most data are acquired at 1 mm, which limits their use in neurodegenerative diseases that affect fine brain structures. We introduce, to our knowledge, the first diffusion-model-based reconstruction for quantitative MRI at 0.5 mm isotropic resolution from scans of less than 5 minutes, which has eightfold smaller voxel volume than clinical protocols. The key idea is to apply the prior to the synthesized contrast images rather than to the subspace coefficients. The prior is then independent of the temporal basis and the sequence, which improves generalization and allows a 2-D multiscale energy (MuSE) model trained on grayscale CelebA face images to be used without any MRI training data. The explicit energy makes reconstruction MAP estimation by a step-size-free majorize-minimize algorithm that regularizes a rotating subset of contrasts along different axes, which makes 3-D multi-contrast reconstruction tractable. For 3-D radial MPnRAGE at 7 T in 4.3 min, MuSE reduced the phantom NRMSE from 0.133 (CG-SENSE) and 0.091 (L1-wavelet) to 0.074 and the WM T1 interquartile range from 117 and 47 ms to 38 ms, and it was demonstrated in vivo at 7 T.

Comment
5 pages, 3 figures

Closest papers

Nearest neighbours by meaning across the whole index.

D-MOD: Diffusion mode estimation for accelerated MRI

cs.LG ·2026-10-29 ·Md Kawsar Ahmed, Mathews Jacob
theory similarity 0.73
Abstract

Diffusion models are powerful priors for accelerated MRI reconstruction, but most current methods are posterior samplers, which return a random draw from the posterior. A reproducible and high-quality reconstruction often requires averaging many samples, resulting in a high computational cost. We introduce D-MOD, a fast algorithm that instead provides a posterior mode. It uses a minorize-maximize algorithm on a lower bound of the smoothed log-posterior, which provably increases the objective. Each iteration draws S noisy samples of the current estimate at the current noise level, denoises them with a pretrained diffusion model, and combines their average with the measured k-space through a conjugate-gradient (CG) solve. We anneal the noise levels, as the distance between the bound and its target decays quadratically with noise. On fastMRI brain (T1, T2, FLAIR), a single D-MOD reconstruction exceeds, in PSNR, the 10-sample finite-MMSE estimates of DPS, DAPS and SNORE-P and stays within 0.31 dB of the strongest baselines (DiffPIR, DDS). This approach thus provides a fast deterministic reconstruction algorithm (11-73 times faster than MMSE estimates), which is useful in a clinical setting.

0.36

Unified Multi-plane Autoregressive Diffusion for 3D Multi-contrast MRI Synthesis

cs.CV ·2026-10-07 ·Yejee Shin, Geonhui Son, Jinglu Wang, Minwoo Jung, Yan Lu +1 more
top venue similarity 0.73
Abstract · Accepted to ECCV 2026

Acquiring a complete set of magnetic resonance imaging (MRI) contrasts is time-intensive and uncomfortable for patients, despite the diagnostic value of multi-contrast imaging. This motivates synthesizing missing contrasts from those already acquired, which is an inherently 3D problem requiring anatomical coherence across axial, sagittal, and coronal planes. However, fully 3D generative models are often impracti- cal under computational resources that scale cubically with volume size. We propose a unified Multi-Plane Autoregressive Diffusion (MPAD), a latent diffusion framework that achieves full-volume 3D synthesis using efficient plane-wise 2D operations while preserving volumetric coherence. A 3D autoencoder first compresses MRI scans into an isotropic 3D la- tent representation. A 2D diffusion model is then trained to reconstruct masked latent slices of the target contrast, conditioned on both source- contrast slices and unmasked target-contrast slices. During inference, we introduce plane-wise autoregressive synthesis with inter-plane priors. Slices are generated autoregressively in random order within one plane orientation to maintain intra-plane continuity, then propagated as con- ditioning priors to orthogonal plane orientations to enforce inter-plane consistency. Compared to 3D latent diffusion baselines, MPAD reduces training and inference FLOPs by 7x and 3x, respectively, while also lowering inference time and peak memory consumption. Experiments on multiple datasets demonstrate that MPAD achieves superior perfor- mance, generating high-fidelity 3D volumes and supporting one-to-many translation within a single unified model.

0.33

Consistency Models for Fast MRI Reconstruction Using Regularization by Denoising

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-20 ·Merve Gülle, Junno Yun, Yaşar Utku Alçalar, Mehmet Akçakaya
code/data similarity 0.72
Abstract

Diffusion models (DMs) have emerged as powerful generative priors for MRI reconstruction with promising results. Yet DM-based methods require extensive iterative refinement, limiting their practical deployment. Consistency models (CMs) provide a compelling alternative, aiming to map out the diffusion trajectory in a single pass, enabling faster generation. In this work, we propose CM-RED, a novel MRI reconstruction method that integrates a pretrained CM into the regularization by denoising (RED) scheme. Our method builds on accelerated proximal gradient RED (RED-APG), and further incorporates controlled noise injection during the update steps to enhance generative diversity and accelerate convergence. Extensive experiments on the fastMRI knee and brain datasets demonstrate that CM-RED achieves high-quality reconstructions across multiple anatomies, contrast weights, acceleration factors, and undersampling patterns, using only 4 network function evaluations (NFEs). The proposed method consistently outperforms existing DM- and CM-based approaches in both quantitative metrics and visual fidelity, and exhibits strong robustness to hyperparameter variations, highlighting CM-RED as an efficient and effective generative framework for accelerated MRI reconstruction. The source code and pretrained models are publicly available at https://github.com/MerveGulle/CM-RED.

0.31

Cascaded Posterior Sampling With Diffusion Priors for highly Accelerated MRI

eess.IV ·2026-10-25 ·Jyothi Rikhab Chand, Sahil Murtaza, Patrick Nicholas Nowak, Mathews Jacob
similarity 0.71
Abstract

Diffusion models are powerful priors for inverse problems, including accelerated MRI. However, modeling the distribution of high-resolution images requires large networks with high computational cost. We propose a posterior sampling framework that uses cascaded diffusion models as multiscale priors. Conditioned on a coarse image, the distribution of fine-scale detail is local and well conditioned, and it can therefore be captured by a small network. Similarly, a small unconditional network is sufficient to represent low-resolution images, and it is used to recover the coarse image from the k-space center. This estimate then conditions the high-resolution prior, which is combined with all measurements to recover the final image. Both priors are trained on images alone, so they apply to any sampling pattern, and data consistency remains linear at every scale. In multi-coil brain MRI, the proposed method improves on the best single-scale diffusion baseline by 4-6 dB in PSNR at 15x acceleration, while each of its separately trained networks is about 10x smaller. The gain grows as the problem becomes more ill-posed, and ablations show that it arises from informative low-resolution conditioning.

0.06

Revolutionizing Diffusion MRI Microstructure Mapping via Global Inversion

eess.IV eess.SP ·2026-09-24 ·Yuxiang Wan, Hamza Farooq, Wenjie Zhang, Qiaozhi Huang, Lingjie Su +2 more
similarity 0.70
Abstract

Diffusion MRI microstructure mapping (MM) is conventionally solved voxel by voxel, ignoring the fact that tissue microstructure forms a spatially organized field. This isolation leaves each estimation problem ill-posed and nonconvex. We instead cast MM as a single global inverse problem, reconstructing the entire parameter field jointly from all measurements of a subject. An untrained neural representation supplies implicit spatial priors and eases the nonconvex optimization, requiring no training data, while coregistered T1-weighted anatomy contributes structural guidance that is freely available in standard protocols. On both synthetic and in-vivo data, our method compares favorably with established voxel-wise and learning-based baselines, suggesting global inversion is a promising alternative.

0.18

Arbitrary-Scale Anisotropic 3D MRI Super-Resolution with Gaussian Prototypes

cs.CV ·2026-10-17 ·Aditya Rastogi, Ramon Leiser, Prateek Singh, Martha Foltyn-Dumitru, Martin Bendszus +6 more
similarity 0.69
Abstract · 26 pages, 6 figures, 15 tables (including appendix)

Reducing MRI acquisition time improves patient comfort, reduces motion artefacts, and increases scanner throughput. Clinical protocols often shorten acquisitions by sacrificing spatial resolution, particularly along the slice axis. Super-resolution can recover higher-resolution images, but existing methods are typically specialised to one scale or acquisition geometry, limiting their use across heterogeneous clinical protocols. We present GSMR3D, a continuous volumetric model that reconstructs arbitrary isotropic and anisotropic resolutions with a single checkpoint per MRI contrast. It combines a learned dictionary of anisotropic 3D Gaussian prototypes with scale-conditioned frequency encoding and an exact measurement-consistency projection, keeping reconstructions consistent with the acquired low-resolution data. We train separate models on 3,731 contrast-enhanced T1-weighted and 30,254 T1-weighted brain MRI volumes from clinical and population-based cohorts. We evaluate GSMR3D against geometry-specific specialists for isotropic, in-plane, and through-plane super-resolution using reconstruction quality and downstream tasks: brain tumour segmentation, brain-metastasis detection, and brain parcellation. GSMR3D outperforms specialists at isotropic $2\times$ and achieves better LPIPS, DISTS, and FID across all geometries, although specialists retain higher PSNR in anisotropic settings. It more faithfully preserves glioma segmentations across all geometries, achieves the highest lesion sensitivity on an independent brain-metastasis cohort, and the highest brain-parcellation agreement for isotropic and in-plane reconstruction. Reconstruction takes about 6s per volume, adding little overhead relative to acquisition-time savings. GSMR3D offers a flexible approach to MRI scan-time reduction with one model per contrast across geometries while preserving information relevant to downstream tasks.

0.17

Multimodal-Conditioned Latent Diffusion Models for Spatiotemporal Brain MRI Forecasting

cs.CV cs.AI ·2026-10-18 ·Antonio Scardace, Silvia Ingala, Sebastiano Battiato, Daniele Ravì
publishedcode/data similarity 0.68
Abstract · Accepted to WACV 2027

Spatiotemporal forecasting of 3D anatomical changes is a critical generative vision challenge for modeling Alzheimer's Disease (AD) progression. While brain MRI forecasting from single-modality data has advanced, other key complementary multimodal biomarkers remain underutilized. In this work, we propose the Multimodal-Conditioned Latent Diffusion Model (MC-LDM), a novel framework for patient-specific brain MRI synthesis. MC-LDM leverages multimodal biomarkers---MRI, tau-PET, Clinical Dementia Rating (CDR), and APOE4---during training, but relies only on baseline MRI, APOE4, and patient metadata at inference, reflecting realistic clinical availability. Our contributions are threefold: (1) a Latent Diffusion Model (LDM) fine-tuned via Low-Rank Adaptation (LoRA) for data-efficient learning; (2) a multimodal conditioning that integrates molecular and clinical signals to model heterogeneous disease trajectories; and (3) auxiliary predictors estimating unobserved multimodal biomarkers from MRI features and patient covariates to condition the diffusion model, removing the need for these assessments at inference. Trained on 1,355 visits from 852 subjects in the Alzheimer's Disease Neuroimaging Initiative (ADNI), MC-LDM reduces average regional volumetric MAE by 18% over the second-best baseline on an independent test set of 664 visits. To our knowledge, MC-LDM represents the first diffusion-based framework to leverage multimodal priors for MRI forecasting. This conceptual advancement enables patient-specific trajectory generation that captures aspects of AD heterogeneity not observable from structural anatomy alone, bridging the gap between rich multimodal supervision and the strict constraints of routine clinical deployment. Code is available at: https://github.com/antonioscardace/MC-LDM.

0.43

Uncertainty-Aware 3D Residual Wavelet Diffusion for Ultra Low-Field MRI Super-Resolution

cs.CV ·2026-09-21 ·Rui W. Yeow, Millie Beament, Fred Dick, Raha Razin, Martina Bocchetta +4 more
published similarity 0.68
Abstract · 11 pages, 3 figures, 1 table. Accepted at SASHIMI 2026 (MICCAI 2026 workshop). This is the version submitted for peer review

Ultra low-field MRI expands global access to neuroimaging but produces scans with low signal-to-noise ratio, reduced contrast, and thick slices. While regression-based super-resolution can recover anatomical detail for segmentation, it returns a single deterministic estimate that gives no indication of regions where the low-field input leaves anatomy underdetermined. Generative diffusion models offer an alternative by sampling the posterior distribution of plausible high-field images, quantifying this anatomical ambiguity. However, applying them to 3D whole-brain MRI is restricted by memory bottlenecks, slow sampling, and scanner domain shifts. We propose a 3D residual wavelet diffusion model that combines three ideas to overcome these hurdles. A lossless wavelet reparameterisation shrinks the spatial grid to fit a whole brain on a single GPU, residual shifting accelerates sampling by starting from the low-field input, and domain randomisation promotes scanner generalisation without paired training data. As the high-field reference is not a voxel-aligned ground truth, we evaluate downstream volumetric agreement. On a healthy cohort (n=19) imaged at 0.064T and 3T, our method matches a leading general-purpose regression approach in volumetric accuracy while additionally generating per-voxel uncertainty maps highlighting underdetermined regions. Furthermore, on a pilot dataset (n=11) of participants with cognitive impairment, disease-relevant atrophy is preserved rather than normalised towards a healthy prior. Our framework brings whole-brain posterior sampling to low-field super-resolution without sacrificing volumetric accuracy.

0.35