CS Paper Radar

Uncertainty-Aware 3D Residual Wavelet Diffusion for Ultra Low-Field MRI Super-Resolution

Rui W. Yeow, Millie Beament, Fred Dick, Raha Razin, Martina Bocchetta, David L. Thomas, Henry F. J. Tregidgo, Daniel C. Alexander, James H. Cole

cs.CV ·submitted 2026-09-21 19:10 UTC · v1
published

Abstract

Ultra low-field MRI expands global access to neuroimaging but produces scans with low signal-to-noise ratio, reduced contrast, and thick slices. While regression-based super-resolution can recover anatomical detail for segmentation, it returns a single deterministic estimate that gives no indication of regions where the low-field input leaves anatomy underdetermined. Generative diffusion models offer an alternative by sampling the posterior distribution of plausible high-field images, quantifying this anatomical ambiguity. However, applying them to 3D whole-brain MRI is restricted by memory bottlenecks, slow sampling, and scanner domain shifts. We propose a 3D residual wavelet diffusion model that combines three ideas to overcome these hurdles. A lossless wavelet reparameterisation shrinks the spatial grid to fit a whole brain on a single GPU, residual shifting accelerates sampling by starting from the low-field input, and domain randomisation promotes scanner generalisation without paired training data. As the high-field reference is not a voxel-aligned ground truth, we evaluate downstream volumetric agreement. On a healthy cohort (n=19) imaged at 0.064T and 3T, our method matches a leading general-purpose regression approach in volumetric accuracy while additionally generating per-voxel uncertainty maps highlighting underdetermined regions. Furthermore, on a pilot dataset (n=11) of participants with cognitive impairment, disease-relevant atrophy is preserved rather than normalised towards a healthy prior. Our framework brings whole-brain posterior sampling to low-field super-resolution without sacrificing volumetric accuracy.

Comment
11 pages, 3 figures, 1 table. Accepted at SASHIMI 2026 (MICCAI 2026 workshop). This is the version submitted for peer review

Closest papers

Nearest neighbours by meaning across the whole index.

Prior-Guided Implicit Neural Representations for Single-Subject Diffusion MRI Super-Resolution

eess.IV cs.CV ·2026-09-01 ·Abdulkader Ghandoura, Marsil Zakour, William Consagra, Yogesh Rathi
publishedcode/data similarity 0.72
Abstract · Accepted at the British Machine Vision Conference (BMVC) 2026. 16 pages, 5 figures, 2 tables. Project page: https://abdulkaderghandoura.gith…

Resolving complex fiber geometries in brain white matter requires high-resolution diffusion MRI at the cost of long acquisition times. This leads many clinical protocols to opt for low-resolution scans, making downstream microstructure estimation and tractography challenging. Implicit neural representations (INRs) can model the diffusion signal continuously, enabling native single-subject super-resolution by querying the network at arbitrary spatial coordinates, yet existing methods often suffer from long training times and lack a mechanism to incorporate anatomical priors to regularize super-resolution by constraining the space of plausible reconstructions. To address these limitations, we propose a novel transfer-learning framework that pre-trains an INR on a high-resolution template and then adapts it to subject-specific scans via registration and fine-tuning. For $4\times$ through-plane super-resolution from 5 mm to 1.25 mm on Human Connectome Project (HCP) data, our method reduces NRMSE by 36-49% and increases FSIM by 24-43% over a recent baseline with $6\times$ faster training, outperforming competing INR-based methods across both image quality and domain-specific metrics. Code is available on the project page at https://abdulkaderghandoura.github.io/research/msc-thesis/ .

0.81

Cascaded Posterior Sampling With Diffusion Priors for highly Accelerated MRI

eess.IV ·2026-10-25 ·Jyothi Rikhab Chand, Sahil Murtaza, Patrick Nicholas Nowak, Mathews Jacob
similarity 0.70
Abstract

Diffusion models are powerful priors for inverse problems, including accelerated MRI. However, modeling the distribution of high-resolution images requires large networks with high computational cost. We propose a posterior sampling framework that uses cascaded diffusion models as multiscale priors. Conditioned on a coarse image, the distribution of fine-scale detail is local and well conditioned, and it can therefore be captured by a small network. Similarly, a small unconditional network is sufficient to represent low-resolution images, and it is used to recover the coarse image from the k-space center. This estimate then conditions the high-resolution prior, which is combined with all measurements to recover the final image. Both priors are trained on images alone, so they apply to any sampling pattern, and data consistency remains linear at every scale. In multi-coil brain MRI, the proposed method improves on the best single-scale diffusion baseline by 4-6 dB in PSNR at 15x acceleration, while each of its separately trained networks is about 10x smaller. The gain grows as the problem becomes more ill-posed, and ablations show that it arises from informative low-resolution conditioning.

0.06

Revolutionizing Diffusion MRI Microstructure Mapping via Global Inversion

eess.IV eess.SP ·2026-09-24 ·Yuxiang Wan, Hamza Farooq, Wenjie Zhang, Qiaozhi Huang, Lingjie Su +2 more
similarity 0.69
Abstract

Diffusion MRI microstructure mapping (MM) is conventionally solved voxel by voxel, ignoring the fact that tissue microstructure forms a spatially organized field. This isolation leaves each estimation problem ill-posed and nonconvex. We instead cast MM as a single global inverse problem, reconstructing the entire parameter field jointly from all measurements of a subject. An untrained neural representation supplies implicit spatial priors and eases the nonconvex optimization, requiring no training data, while coregistered T1-weighted anatomy contributes structural guidance that is freely available in standard protocols. On both synthetic and in-vivo data, our method compares favorably with established voxel-wise and learning-based baselines, suggesting global inversion is a promising alternative.

0.18

Generalizable field of view extension for diffusion MRI via conditional flow matching

cs.AI ·2026-10-12 ·Gaurav Rudravaram, Lianrui Zuo, Ema Topolnjak, Michael E. Kim, Adam M. Saunders +20 more
similarity 0.69
Abstract

Incomplete field-of-view (FOV) diffusion MRI (dMRI) acquisitions compromise whole-brain white matter analysis by excluding brain regions from tractography and connectivity studies. While deep generative models for dMRI FOV extension have been proposed, their generalizability remains limited by the acquisition-dependent nature of dMRI, where signal intensity varies with b-value, gradient direction, and scanner protocol, and the inherent 4D complexity of the data, making it difficult to train models that transfer across sites or acquisition schemes without retraining. We propose a flow-matching generative model that extends the dMRI FOV in both the superior and inferior directions by predicting apparent diffusion coefficients (ADC) in six directions, conditioned on the two nearest acquired slices and the full-FOV T1w image to enforce both local diffusion continuity and anatomical consistency. The ADC representation decouples the model from acquisition-specific b-values and gradient directions, providing a middle-ground across protocols. The model was trained on 3,103 subjects (5,105 sessions) across five different datasets spanning diverse acquisition schemes (b = 500 and 1000 s/mm$^2$; 21--192 gradient directions), four single-shell (b = 1000) and one multi-shell (b = 500/1000). Evaluated on 299 subjects across five independent datasets spanning b = 750--1500 s/mm$^2$ and 32--90 gradient directions, with single- and multi-shell schemes unseen during training, the proposed method achieves significantly improved bundle Dice score on downstream tractography (p < 0.01).

0.16

MRI Super-Resolution with RCDM/WaveMix and Task-Aware Segmentation

cs.CV ·2026-09-30 ·Kavitha Viswanathan, Harsh Choudhary, Amit Sethi
similarity 0.69
Abstract

Super-resolution and quality enhancement of 1.5\,T brain MRI are normally validated with image-fidelity metrics, although their purpose is to improve downstream analysis. We study whether enhancement improves tissue segmentation, and for which segmenters. We propose an unpaired, physics-guided training pipeline for a lightweight ($\le$2.5\,M parameter) recurrent convolutional enhancer: a six-module stochastic 1.5\,T degradation operator, a residual adversarial network that adds scanner-specific texture without moving anatomy, and a cycle-consistent objective with an anti-identity penalty that rules out the copy solution. We then train U-Net, Swin-UNet and wavelet token-mixing segmenters \citep{jeevan2023wavemix} from scratch on either raw or enhanced 1.5\,T images of the same subjects, using identical labels and subject-level splits, for three enhancer variants and two datasets. On ABIDE (41 held-out subjects, FreeSurfer labels) enhancement significantly improves the wavelet segmenter (mean Dice $+0.014$, Wilcoxon $p=3.5\times10^{-5}$; CSF $+0.018$, grey matter $+0.013$), significantly degrades the U-Net ($-0.008$, $p=5.1\times10^{-4}$) and leaves Swin-UNet unchanged. On IXI, whose labels come from FSL-FAST, enhancement lowers Dice for all nine pairings, almost entirely through CSF; we trace this to spatially implausible CSF voxels in the labels that penalise smoother predictions. Enhancement of low-field MRI should therefore be validated per downstream model and against reliable labels.

0.14

Implicit Neural Models for Direct Multi-Shell Diffusion MRI Signal Estimation

eess.IV cs.CV ·2026-10-16 ·Sanna Persson, Fabian Leander Sinzinger, Christoffer Olsson, Rodrigo Moreno
similarity 0.69
Abstract · 23 pages (9 pages main text + supplementary material), 9 figures, 18 tables

Diffusion magnetic resonance imaging is a noninvasive technique that is sensitive to the motion of water molecules in human tissue. The image signal is commonly described in q-space; however, a complete coverage of this space is often infeasible due to hardware and acquisition time limitations. In this work, we propose to represent the entire diffusion signal using an implicit neural representation network with wavelet activation functions. The signal space is encoded using Fourier features and spherical harmonics basis functions for a continuous output distribution of the raw diffusion data, enabling both super-resolution and q-space interpolation. Additionally, we introduce a pretraining strategy using a group template, enabling faster per-subject optimisation when combined with nonlinear registrations of subjects into template space. We tested the method with 10 subjects from the Human Connectome Project and 26 subjects from in-house data (multidimensional diffusion MRI from a Parkinson's disease cohort). The results show that the proposed method yields high-fidelity reconstructions with significantly reduced memory requirements compared to raw diffusion-weighted images. The pretraining scheme showed good generalisability properties on data acquired with very different protocols. We further assess the method on downstream metrics relevant to diffusion MRI data from the learned representations.

0.31

A Dual-Stream Regulated Reconstruction and Segmentation Network with Hierarchical Artifact-Prior Modeling for Ultra-Low-Field Pediatric Neuroimaging

cs.CV ·2026-09-17 ·Bahram Jafrasteh, Leo Milecki, Qingyu Zhao
similarity 0.68
Abstract

Automated quality assessment, enhancement, and segmentation of multiple structures in $0.064\,\mathrm{T}$ ultra-low-field pediatric MRI are limited by a low signal-to-noise ratio, weak anatomical boundaries, and frequent artifacts. We present a unified framework for the LISA 2026 Challenge that performs all three tasks together within one inference pipeline. A network with two coupled streams, built on a 3D U-Net, first reconstructs an enhanced uLF volume and then combines the original and enhanced images for subcortical segmentation. To improve boundary stability, we add an auxiliary class covering brain tissue outside the target structures, derived from whole brain masks. A head conditioned on an artifact graph predicts the seven artifact ratings from reconstruction residuals and frozen segmentation features. We address the scarcity of dense annotations using diffeomorphic registration from atlas to target for label propagation and to regularize anatomical reconstruction. We report validation results across all three tasks.

0.12

High-Resolution Quantitative MRI Using Contrast-Domain Multiscale Energy (MuSE) Regularization

eess.IV ·2026-11-03 ·Rushdi Rusho, Jyothi Rikhab Chand, Steve R. Kecskemeti, James H. Holmes, Mathews Jacob
similarity 0.68
Abstract · 5 pages, 3 figures

Quantitative MRI methods can offer tissue parameter maps (e.g. T1) that are comparable across scanners, sessions and subjects, together with multiple contrast-weighted images from a single scan. However, most data are acquired at 1 mm, which limits their use in neurodegenerative diseases that affect fine brain structures. We introduce, to our knowledge, the first diffusion-model-based reconstruction for quantitative MRI at 0.5 mm isotropic resolution from scans of less than 5 minutes, which has eightfold smaller voxel volume than clinical protocols. The key idea is to apply the prior to the synthesized contrast images rather than to the subspace coefficients. The prior is then independent of the temporal basis and the sequence, which improves generalization and allows a 2-D multiscale energy (MuSE) model trained on grayscale CelebA face images to be used without any MRI training data. The explicit energy makes reconstruction MAP estimation by a step-size-free majorize-minimize algorithm that regularizes a rotating subset of contrasts along different axes, which makes 3-D multi-contrast reconstruction tractable. For 3-D radial MPnRAGE at 7 T in 4.3 min, MuSE reduced the phantom NRMSE from 0.133 (CG-SENSE) and 0.091 (L1-wavelet) to 0.074 and the WM T1 interquartile range from 117 and 47 ms to 38 ms, and it was demonstrated in vivo at 7 T.

0.24