CS Paper Radar

MRI Super-Resolution with RCDM/WaveMix and Task-Aware Segmentation

Kavitha Viswanathan, Harsh Choudhary, Amit Sethi

cs.CV ·submitted 2026-09-30 06:23 UTC · v1

Abstract

Super-resolution and quality enhancement of 1.5\,T brain MRI are normally validated with image-fidelity metrics, although their purpose is to improve downstream analysis. We study whether enhancement improves tissue segmentation, and for which segmenters. We propose an unpaired, physics-guided training pipeline for a lightweight ($\le$2.5\,M parameter) recurrent convolutional enhancer: a six-module stochastic 1.5\,T degradation operator, a residual adversarial network that adds scanner-specific texture without moving anatomy, and a cycle-consistent objective with an anti-identity penalty that rules out the copy solution. We then train U-Net, Swin-UNet and wavelet token-mixing segmenters \citep{jeevan2023wavemix} from scratch on either raw or enhanced 1.5\,T images of the same subjects, using identical labels and subject-level splits, for three enhancer variants and two datasets. On ABIDE (41 held-out subjects, FreeSurfer labels) enhancement significantly improves the wavelet segmenter (mean Dice $+0.014$, Wilcoxon $p=3.5\times10^{-5}$; CSF $+0.018$, grey matter $+0.013$), significantly degrades the U-Net ($-0.008$, $p=5.1\times10^{-4}$) and leaves Swin-UNet unchanged. On IXI, whose labels come from FSL-FAST, enhancement lowers Dice for all nine pairings, almost entirely through CSF; we trace this to spatially implausible CSF voxels in the labels that penalise smoother predictions. Enhancement of low-field MRI should therefore be validated per downstream model and against reliable labels.

Closest papers

Nearest neighbours by meaning across the whole index.

CAPS: Clinically-Verifiable Anatomy-Prioritized Synthesis for Missing MRI Imputation in Brain Tumor Segmentation

eess.IV cs.CV ·2026-10-20 ·Cecilia Diana-Albelda, Arthur Longuefosse, Mario Rubén Paz Campos, Álvaro García-Martín, Jesus Bescos
similarity 0.69
Abstract · 20 pages, 6 figures, 8 tables. Cecilia Diana-Albelda and Arthur Longuefosse contributed equally

Multi-parametric MRI is the gold standard for neuro-oncology, yet acquiring complete 4-modality protocols may be unfeasible in real-world clinical practice. When handling missing modalities, existing automated systems force a critical compromise: robust segmenters operate as uninterpretable "black boxes" that bypass image generation, while standard synthesis models often produce blurry reconstructions lacking diagnostic reliability. To address this issue, we propose CAPS, a Clinically-Verifiable Anatomy-Prioritized Synthesis framework that reconciles computational precision with clinical transparency. Our multi-modal generative architecture is driven by a hybrid objective function (L_1 + L_AFP + L_DualDice) that explicitly enforces the preservation of deep anatomical features and strict topological boundaries, rather than relying solely on pixel-wise optimization. Evaluated comprehensively on the BraTS Adult Glioma dataset, the framework achieves superior synthesis fidelity across intensity-based metrics, and demonstrates robust downstream segmentation performance (82.38% mean Dice), successfully restoring verifiable visual context. Furthermore, the framework exhibits exceptional zero-shot cross-domain generalization, maintaining high structural fidelity across completely unseen Meningioma, Pediatric, and Sub-Saharan African cohorts without domain-specific adaptation. Finally, a blinded radiological assessment confirms that our anatomy-aware approach significantly enhances both perceived image quality and clinical utility, providing clinicians with the reliable visual evidence required to trust downstream automated workflows.

0.20

Uncertainty-Aware 3D Residual Wavelet Diffusion for Ultra Low-Field MRI Super-Resolution

cs.CV ·2026-09-21 ·Rui W. Yeow, Millie Beament, Fred Dick, Raha Razin, Martina Bocchetta +4 more
published similarity 0.69
Abstract · 11 pages, 3 figures, 1 table. Accepted at SASHIMI 2026 (MICCAI 2026 workshop). This is the version submitted for peer review

Ultra low-field MRI expands global access to neuroimaging but produces scans with low signal-to-noise ratio, reduced contrast, and thick slices. While regression-based super-resolution can recover anatomical detail for segmentation, it returns a single deterministic estimate that gives no indication of regions where the low-field input leaves anatomy underdetermined. Generative diffusion models offer an alternative by sampling the posterior distribution of plausible high-field images, quantifying this anatomical ambiguity. However, applying them to 3D whole-brain MRI is restricted by memory bottlenecks, slow sampling, and scanner domain shifts. We propose a 3D residual wavelet diffusion model that combines three ideas to overcome these hurdles. A lossless wavelet reparameterisation shrinks the spatial grid to fit a whole brain on a single GPU, residual shifting accelerates sampling by starting from the low-field input, and domain randomisation promotes scanner generalisation without paired training data. As the high-field reference is not a voxel-aligned ground truth, we evaluate downstream volumetric agreement. On a healthy cohort (n=19) imaged at 0.064T and 3T, our method matches a leading general-purpose regression approach in volumetric accuracy while additionally generating per-voxel uncertainty maps highlighting underdetermined regions. Furthermore, on a pilot dataset (n=11) of participants with cognitive impairment, disease-relevant atrophy is preserved rather than normalised towards a healthy prior. Our framework brings whole-brain posterior sampling to low-field super-resolution without sacrificing volumetric accuracy.

0.35

A Dual-Stream Regulated Reconstruction and Segmentation Network with Hierarchical Artifact-Prior Modeling for Ultra-Low-Field Pediatric Neuroimaging

cs.CV ·2026-09-17 ·Bahram Jafrasteh, Leo Milecki, Qingyu Zhao
similarity 0.69
Abstract

Automated quality assessment, enhancement, and segmentation of multiple structures in $0.064\,\mathrm{T}$ ultra-low-field pediatric MRI are limited by a low signal-to-noise ratio, weak anatomical boundaries, and frequent artifacts. We present a unified framework for the LISA 2026 Challenge that performs all three tasks together within one inference pipeline. A network with two coupled streams, built on a 3D U-Net, first reconstructs an enhanced uLF volume and then combines the original and enhanced images for subcortical segmentation. To improve boundary stability, we add an auxiliary class covering brain tissue outside the target structures, derived from whole brain masks. A head conditioned on an artifact graph predicts the seven artifact ratings from reconstruction residuals and frozen segmentation features. We address the scarcity of dense annotations using diffeomorphic registration from atlas to target for label propagation and to regularize anatomical reconstruction. We report validation results across all three tasks.

0.12

Multi-Resolution Feature Fusion U-Net for Magnetic Resonance Imaging Segmentation

cs.CV cs.LG ·2026-09-24 ·Eirini Cholopoulou, Dimitrios E. Diamantis, Dimitris K. Iakovidis
publishedbenchmark similarity 0.68
Abstract

The segmentation of anatomical structures in medical images and particularly in MRI scans, is essential for clinical diagnosis and monitoring disease progression. While Deep Learning (DL) architectures, such as U-Net and its extensions are very effective in medical image segmentation tasks, they often struggle with preserving fine-grained details and global contextual information. This is especially challenging for MRI data segmentation, where anatomical structures are characterized by irregular boundaries and variations in shape, contrast, and scale. To address this challenge, we propose a novel DL architecture for MRI segmentation across different anatomical structures. Specifically, the architecture introduces a module, named Multi-Resolution Feature Fusion (MRFF), that can be easily integrated into any U-Net-like architecture. The MRFF is integrated in all levels of an encode-decoder structure, along with attention mechanisms and skip connections to extract features at multiple resolutions, enabling the model to capture both fine-grained details and global contextual information. We evaluate the MRFFU-Net on two publicly available benchmark MRI datasets of different anatomical targets; one for Cerebrospinal Fluid (CSF) segmentation in spinal MR scans, and one for left atrium cardiac segmentation, from the Medical Segmentation Decathlon (MSD) challenge. Experimental results indicate that MRFFU-Net outperforms state-of-the-art models across multiple evaluation metrics, demonstrating its effectiveness in MRI segmentation.

0.44

Motion Artifact-Aware Self-Supervised Representation Learning for 3D Brain MRI Motion Artifact Reduction

cs.CV physics.med-ph ·2026-08-10 ·Mojtaba Safari, Shansong Wang, Zach Eidex, Matthew Goette, Tonghe Wang +2 more
top venue similarity 0.68
Abstract

Patient motion remains a source of image degradation in brain MRI, leading to signal loss, blurring, and geometric distortion that compromise quantitative analysis. Existing deep learning methods for motion correction typically rely on paired clean-corrupted data or k-space acquisitions, which are rarely available in clinical settings. We propose SSRL-MAR, a motion artifact-aware unpaired representation learning framework for motion artifact reduction that requires neither paired training data nor explicit motion labels. SSRL-MAR employed a three-stage training strategy: (1) contrastive learning on 3D patches to extract motion representations by contrasting clean and synthetically corrupted images, (2) a motion artifact-aware synthesis network to generate motion artifacts from clean scans, and (3) a motion artifact-aware generator to restore clean volumes using the learned degrader for self-supervised supervision. On in-silico dataset, SSRL-MAR achieved PSNR 23.81dB, SSIM 91.55%, and NMSE 0.79%. On in-vivo MR-ART dataset, the pretrained model reduced motion distortion, and unsupervised domain adaptation further improved anatomical fidelity. Against a source-only supervised model trained on the same simulated pairs, SSRL-MAR improved PSNR by up to 2.0 dB on MR-ART after unsupervised domain adaptation, and remained within 0.25-0.47 dB of an oracle supervised model that requires real paired data unavailable in practice. At the milder motion level, volumetric error in structures such as the corpus callosum and ventricular system decreased by more than 50%, confirming improved neuroanatomical consistency. These results indicate that SSRL-MAR provides a robust and scalable image-domain solution for 3D brain MRI motion correction, enabling reliable structural quantification in large-scale neuroimaging studies without requiring prospectively acquired pairs or acquisition-specific calibration.

0.29

MRIComp4Flow: Compression of 3D Brain MRI for Training Multi-Modal Generative Models

cs.CV cs.AIcs.LG ·2026-08-10 ·Lisa K. Fischer, Mykhailo Riabets, Daniel Rueckert, Benedikt Wiestler, Anke Meyer-Baese +1 more
publishedcode/data similarity 0.68
Abstract · Accepted: MICCAI 2026 SASHIMI workshop

Large-scale multi-modal MRI datasets impose substantial storage and I/O costs, limiting the training of 3D generative models on commodity infrastructure. While lossy compression is known to preserve accuracy for discriminative segmentation networks, its effect on generative models, which must learn the full data distribution rather than a decision boundary, is unexplored. We study whether standard image codecs can effectively compress semantically rich brain tumor MRI while preserving the fidelity required to train and deploy a 3D MRI generative model. Each 3D volume is compressed with JPEG2000 or a near-lossless JPEG-LS pipeline. Next, a Wavelet Flow Matching model, conditioned on BraTS image sequences (T1n, T1c, T2, T2f), is trained on compressed data, and the resulting models are evaluated on the validation set. At a 20:1 compression ratio, synthesis quality is statistically equivalent to a model trained on uncompressed data within a pre-specified margin ($Δ$PSNR $<1$,dB, $Δ$SSIM $<0.02$; paired TOST $p=[[p]]$): mean PSNR is 27.3,dB vs. 27.0,dB and mean SSIM is 0.95 vs. 0.96 across modalities. Our results indicate that JPEG2000 compression is a practical step toward scalable 3D MRI generative modeling without degrading synthesis quality. The codebase is available at https://github.com/lisafis/MRIComp4Flow .

0.38

Mixture of Multi-Sequence Feature Difference for Contrast-Enhanced MRI Synthesis

cs.CV ·2026-10-15 ·Jonghun Kim, Junmo Kwon, Hyunjin Park
similarity 0.67
Abstract · ACCV 2026

Contrast-enhanced magnetic resonance imaging (CE-MRI) is crucial for accurately diagnosing and segmenting brain tumors. However, the acquisition of CE-MRI requires injecting contrast agents, which poses potential health risks and increases scan costs. Here, we propose a CE-MRI synthesis method from non-contrast sequences, reducing both risk and cost. Unlike existing methods that rely on channel-wise concatenation to fuse multi-sequence information for synthesis, we introduce a Mixture of Feature Difference (MoFD) module. The proposed module uses a dynamic weighting strategy to adaptively select and aggregate informative features from both individual source sequences and explicit differences among them. Quantitative and qualitative evaluations demonstrate that our proposed method outperforms baselines in terms of image fidelity and perceptual quality on the UCSF-PDGM and UPenn-GBM datasets. Our method successfully reconstructs tumor regions and achieves segmentation performance comparable to that obtained with real CE-MRI. Our ablation studies show that although adversarial learning improves perceptual quality, a regression-based variant of our method achieves higher structural fidelity.

0.24

EA-LiteUNet: An Edge-Adaptive and Resource-Efficient U-Net for Boundary-Sensitive Dermoscopic Image Segmentation

cs.CV cs.AI ·2026-08-16 ·Wang Jiangtao, Nur Intan Raihana Ruhaiyem, Fu Panpan, Yang Yu, Huang Yan
similarity 0.67
Abstract · 29 Pages,13 figures, 8 tables

Accurate boundary delineation remains a persistent challenge in dermoscopic image segmentation because of blurred lesion margins, heterogeneous textures, and complex background artifacts. From a signal-processing perspective, lesion boundaries represent high-frequency components that are highly susceptible to aliasing, noise amplification, and information loss. Consequently, repeated downsampling and feature transformations in conventional convolutional architectures often lead to severely degraded boundary representations. To address these limitations, we propose EA-LiteUNet, an edge-adaptive and computationally efficient U-Net variant specifically designed for boundary-sensitive medical image segmentation. The architecture integrates three core mechanisms: (1) boundary-aware representation learning to suppress aliasing and preserve high-frequency structural details; (2) attention-guided feature modulation to selectively enhance boundary-relevant responses across multi-scale features; and (3) a resource-adaptive inference strategy to dynamically balance segmentation accuracy and computational efficiency. Extensive evaluations across three public dermoscopic datasets demonstrate that EA-LiteUNet consistently achieves superior boundary precision. Specifically, on the ISIC 2018 dataset, the method significantly reduces the 95% Hausdorff Distance (HD95) to 12.89 pixels while maintaining a robust Dice score of 92.08%. Notably, this strong performance is achieved with an ultralightweight configuration of merely 0.29M parameters and 1.17 GFLOPs. Ablation studies further validate the complementary effects of these components, confirming their contribution to enhanced boundary fidelity and stable optimization.

0.10