CS Paper Radar

Learning Where and How Much to Sample: Volume-Adaptive k-Space Acquisition for Accelerated MRI

Reyhaneh Neshatavar, Mohsen Yavartanoo, Kyoung Mu Lee

cs.CV ·submitted 2026-11-18 09:08 UTC · v1

Abstract

Magnetic resonance imaging (MRI) is an essential medical imaging technique, but its high costs and long acquisition times can limit accessibility. Accelerated MRI reduces acquisition time through k-space undersampling, yet conventional methods often rely on predefined sampling patterns and uniform slice budgets, overlooking anatomical variations and inter-slice relationships. In this paper, we propose a volume-adaptive k-space acquisition framework that jointly learns where and how much to sample across an entire MRI volume. Using only acquired auto-calibration signal (ACS) measurements, our method exploits volume-wide anatomical information to adaptively allocate sampling budgets across slices while identifying informative k-space lines. A learned joint slice--frequency refinement module coordinates sampling decisions while preserving an exact total volume-level acquisition budget. To reconstruct the acquired measurements, we design a sensitivity-aware synchronous cross-slice reconstruction network that estimates coil sensitivities from ACS measurements and progressively refines neighboring-slice reconstructions while enforcing hard k-space data consistency. Both networks are jointly optimized using reconstruction-based supervision without requiring fully sampled k-space at inference. Experiments on knee and brain MRI across multiple contrasts and acceleration factors demonstrate the adaptive behavior of our acquisition framework and evaluate its reconstruction performance.

Closest papers

Nearest neighbours by meaning across the whole index.

Coarse-to-Fine 3D MRI Reconstruction via Resolution-Agnostic Neural Operators

eess.IV cs.CV ·2026-11-11 ·Jiayun Wang, Ram Daftari, Weijie Gan, Valentin Duruisseaux, Ruibo Wang +3 more
published similarity 0.69
Abstract · NeurIPS 2026

Deep-learning-based 3D MRI reconstruction is limited in practice by the GPU memory and compute cost of full-volume training; 3D acquisitions are thus most often reconstructed by 2D models applied slice-by-slice and then stacked, which ignores through-plane (stacking-axis) structure. We reconstruct in full 3D and ask whether a model can be trained at low resolution (fast and memory-feasible) yet deployed at higher resolution. This coarse-to-fine strategy needs reliable cross-resolution performance, but standard networks are resolution-specific and degrade substantially when evaluated outside the training setting. We therefore use resolution-agnostic neural operators (NOs) and propose KIR-NO (k-space-to-Image Reconstruction Neural Operator), a discretization-agnostic framework for accelerated 3D MRI reconstruction. KIR-NO is trained with full backpropagation on low-resolution volumes and applied zero-shot to higher-resolution volumes at inference. Its core building block is a 3D neural operator based on discrete-continuous convolutions: convolutional filters are parameterized in a continuous basis and sampled at arbitrary voxel resolutions while preserving the local inductive bias of convolution. KIR-NO integrates these learned operators with physics-based consistency: a k-space neural-operator head first refines the undersampled Fourier measurements, and image-space neural-operator cascades then refine the reconstruction through interleaved data-consistency updates. Across 3D knee and brain MRI benchmarks, KIR-NO improves over classical and CNN baselines: it improves over a state-of-the-art 3D CNN by 2.2 dB PSNR at half resolution under 4x acceleration on SKM-TEA, with gains persisting at 8x and 16x. These results show that resolution-agnostic operators make coarse-to-fine 3D MRI reconstruction - cheap low-resolution training with high-resolution deployment - practical across anatomies.

0.27

Stochastic Finite-Transition Learning and Exploration for Accelerated MRI Reconstruction

eess.IV cs.CVeess.SP ·2026-10-09 ·Muhammad Usama Mirza, Esin Öztürk Işık, Tolga Çukur
similarity 0.69
Abstract

Generative MRI reconstruction maps an initial source distribution to the target image distribution along a learned recovery trajectory. Common generative methods, such as diffusion and flow, typically learn fine-grained local dynamics whose integration defines this global mapping, hence requiring many network evaluations at inference. Existing few-step sampling approaches can lower computational burden by approximating large transformations from local dynamics, albeit at the expense of reconstruction fidelity. FLEX-MRI instead partitions recovery into a small number of finite intervals between retained states defined by progressive changes in k-space support, and directly learns the reconstruction change across each interval. Because such finite transitions can admit multiple plausible outcomes, FLEX-MRI combines support-relaxed finite-transition learning with stochastic exploration. During training, randomized k-space sampling masks define finite-transition targets with varying support, while the prediction loss remains unrestricted by each individual mask. At inference, FLEX-MRI perturbs a random subset of currently estimated k-space coefficients, allowing the learned predictor to stochastically explore alternative transition paths. Each predicted state is then reconciled with the acquired measurements through data consistency. We theoretically show that this stochastic exploration induces nonzero transition-level variation through the learned recovery map and data consistency without requiring an auxiliary generative sampler. Experiments on multi-coil MRI datasets show that FLEX-MRI outperforms competing methods while maintaining computational efficiency comparable to few-step baselines.

0.23

OpenMASC: An Open-Source Pipeline for Cross-Trajectory Metal-Aware Sampling and Correction in Accelerated MRI

cs.CV ·2026-09-26 ·Zhengyi Lu, Ming Lu, Chongyu Qu, Junchao Zhu, Junlin Guo +9 more
code/data similarity 0.69
Abstract

Metal implants corrupt MRI measurements throughout $k$-space, yet existing accelerated MRI methods assume clean data and most metal artifact reduction approaches assume fully sampled acquisitions. No public dataset provides paired $k$-space and images with and without metal for the same anatomy, and no framework jointly addresses artifact-aware acquisition and reconstruction across sampling trajectories. We present OpenMASC, an open-source pipeline covering the full workflow from data generation to deployment. A physics-based data generation module converts public CT volumes into paired clean and metal-corrupted MRI data in both Cartesian and radial formats. MA-VarNet, an unrolled reconstruction network with a per-cascade DC Rectifier, corrects artifacts that data-consistency steps reintroduce from corrupted measurements. A reinforcement learning agent actively selects $k$-space readouts and co-trains with the reconstruction network through a decoupled three-stage procedure. The framework is trajectory-agnostic except for the data-consistency operator, supporting both Cartesian and radial acquisition without architectural changes. Experiments on two datasets at $4\times$ and $8\times$ acceleration demonstrate consistent improvements over conventional and learned baselines on both trajectories.

0.31

Hankel Subspace Self-Supervised Learning for Parallel MRI Reconstruction

cs.CV ·2026-10-08 ·Mingyu Hu, Siquan Zhu, Xijun Zhong, Qiegen Liu
similarity 0.69
Abstract

Parallel magnetic resonance imaging reconstruction is an ill-posed inverse problem under undersampling. Multi-coil acquisition and Hankel lifting expose complementary repeated information: observations of the same anatomy across coils and repeated local k-space neighborhoods in overlapping windows. These dependencies guide recovery of missing k-space data. However, splitting lifted Hankel entries for self-supervision can place the original sample in both input and target, causing data leakage. We propose Hankel Subspace Self-Supervised Reconstruction (HSSRecon), a scan-specific reconstruction framework for parallel magnetic resonance imaging. HSSRecon partitions data by physical acquisition units before Hankel lifting and applies multiplicity normalization to repeated Hankel copies in overlapping windows. Rather than learning a mapping that directly predicts missing data, the network learns a compact complex-valued Hankel subspace operator. Reconstruction is performed over the original k-space variables using a conjugategradient solver with hard data consistency. This design separates structural learning in the Hankel domain from data consistency in the physical domain: the former exploits multi-coil and local Hankel correlations, while the latter solves over unacquired degrees of freedom. We provide theoretical analyses of physicalgroup splitting and multiplicity normalization, and establish positive definiteness, uniqueness, hard data consistency, and a finite-step conjugate-gradient error bound for the system. On fastMRI brain data with three contrasts and three sampling masks, HSSRecon achieves competitive peak signal-to-noise ratio, structural similarity, and normalized mean squared error across six aggregated conditions.

0.16

STAIRS: Staging the Inverse Problem via Admissible-Support Scheduling for Unrolled MRI Reconstruction

cs.CV ·2026-11-06 ·Xiangjian Hou, Chang Ni, Chao Qin, Zhiwei Tan, Xin Wang +4 more
similarity 0.67
Abstract

Accelerated magnetic resonance imaging (MRI) forms images from incomplete Fourier measurements, shifting acquisition burden to computational reconstruction. Deep unrolled networks interleave learned regularization and data consistency, yet typically estimate the full unmeasured spectrum at every cascade. We propose STAIRS (Staging the Inverse Problem via Admissible-Support Scheduling), which projects intermediate reconstructions onto nested Fourier supports that expand to the full spectrum and conditions each update on its support transition. Conditional increments of a regularized log-determinant score of training covariance define a normalized spectral coordinate, accounting for dependencies between newly and previously admitted frequencies. Dyadic targets allocate larger coordinate increments to earlier cascades and are mapped to fixed supports before training, enabling coarse-to-fine reconstruction with unchanged sampling masks and data consistency. On fastMRI and Stanford2D, STAIRS improves matched Transformer (HUMUSNet) and convolutional (NAFNet) backbones in single- and multi-coil reconstruction, including radiologist-annotated pathology regions. It also outperforms predictor-based progression with lower parameter overhead and inference latency. Stage-wise analysis shows repeated error correction by projection and lower intermediate reconstruction errors than the backbones alone throughout support expansion. Ablations favor dyadic allocation over uniform expansion for square and line-band supports and over manual front-loading for square windows. Support projection alone improves reconstruction, and transition conditioning strengthens the gain. Cross-dataset evaluation shows improvements for both backbones in both directions. Support allocation thus complements regularizer design in unrolled MRI reconstruction.

0.22

Physics-based simulation unlocks scaling laws for generalizable MRI reconstruction

eess.IV cs.CV ·2026-11-11 ·Hong Shang, Zijian Zhan, Sen Jia, Xiang Fan, Jintao Meng +8 more
similarity 0.66
Abstract

Deep-learning-based magnetic resonance imaging (MRI) reconstruction holds great promise for accelerating acquisitions, yet its clinical translation remains bottlenecked by poor generalizability across unseen scanners, populations, anatomies, and protocols. Gathering sufficiently diverse clinical datasets to overcome this bottleneck is hindered by high acquisition costs, privacy restrictions, and institutional biases. Here, we introduce Scalable Inverse Model (SIM), a framework that systematically co-designs physics-simulated training data, model architecture, and learning paradigms around scalability--leveraging compute scaling to overcome historical data bottlenecks and achieve robust zero-shot MRI reconstruction. Across 14 public and in-house datasets--spanning seven international centers, five vendors, field strengths of 0.3-7 T, over ten anatomical regions, more than ten acquisition protocols, downstream quantitative and molecular tasks, and a 150-scan blinded radiologist study--SIM demonstrates robust zero-shot generalizability, recovering fine anatomical details while suppressing aliasing artifacts where conventional deep-learning methods fail. Attention-map analyses confirm that SIM learns physically explainable, dynamically adaptive reconstruction primitives rather than anatomy-specific priors. SIM establishes a scalable, privacy-preserving, and democratized infrastructure for universal MRI reconstruction, providing a blueprint for generalizable AI across inverse problems in medical imaging.

0.22

Learning Subject-Specific Anatomical Representations via Manifold Expansion: Application to Accelerated Multi-Contrast MRI

cs.CV cs.IR ·2026-10-02 ·Ruimin Feng, Wanyu Bian, Albert Jang, Zachary Stewart, Fang Liu
similarity 0.65
Abstract

Clinical MRI routinely acquires multiple contrast-weighted images of the same anatomy for complementary tissue characterization. However, current accelerated MRI methods typically reconstruct each contrast independently, without fully exploiting shared anatomical information. This work aims to learn anatomical representations invariant to contrast-dependent appearance for reconstruction of accelerated multi-contrast MRI. We propose MAX (MAnifold eXpansion), a subject-specific framework that learns anatomical representations from a single fully sampled reference contrast. To address the under-constrained separation of shared anatomy and contrast-dependent components from a single image, MAX expands the multi-contrast manifold using anatomy-preserving intensity augmentations. A disentangled implicit neural representation models augmented samples using shared spatial coordinates for anatomy and spatially invariant coordinates for contrast appearance. The learned anatomical representation is then fixed, with the contrast representation adapted to the undersampled target data, followed by unrolled refinement. Theoretical analyses further provide insight into the disentangled representation learning and explain how the learned anatomical representation improves the target contrast reconstruction. At R = 8 for brain MRI and R = 6 for knee MRI, MAX achieves the highest mean PSNR and SSIM across all tasks, improving PSNR by more than 1 dB over the strongest baseline for both brain contrasts. MAX more faithfully recovers subtle anatomical and pathological structures and remains robust to inter-contrast motion, structural heterogeneity between reference and target contrasts, and measurement noise. Therefore, MAX provides a general strategy for leveraging high-quality reference scans in accelerated MRI and has the potential to be extended to other reference-assisted MRI inverse problems.

0.12

Arbitrary-Scale Anisotropic 3D MRI Super-Resolution with Gaussian Prototypes

cs.CV ·2026-10-17 ·Aditya Rastogi, Ramon Leiser, Prateek Singh, Martha Foltyn-Dumitru, Martin Bendszus +6 more
similarity 0.65
Abstract · 26 pages, 6 figures, 15 tables (including appendix)

Reducing MRI acquisition time improves patient comfort, reduces motion artefacts, and increases scanner throughput. Clinical protocols often shorten acquisitions by sacrificing spatial resolution, particularly along the slice axis. Super-resolution can recover higher-resolution images, but existing methods are typically specialised to one scale or acquisition geometry, limiting their use across heterogeneous clinical protocols. We present GSMR3D, a continuous volumetric model that reconstructs arbitrary isotropic and anisotropic resolutions with a single checkpoint per MRI contrast. It combines a learned dictionary of anisotropic 3D Gaussian prototypes with scale-conditioned frequency encoding and an exact measurement-consistency projection, keeping reconstructions consistent with the acquired low-resolution data. We train separate models on 3,731 contrast-enhanced T1-weighted and 30,254 T1-weighted brain MRI volumes from clinical and population-based cohorts. We evaluate GSMR3D against geometry-specific specialists for isotropic, in-plane, and through-plane super-resolution using reconstruction quality and downstream tasks: brain tumour segmentation, brain-metastasis detection, and brain parcellation. GSMR3D outperforms specialists at isotropic $2\times$ and achieves better LPIPS, DISTS, and FID across all geometries, although specialists retain higher PSNR in anisotropic settings. It more faithfully preserves glioma segmentations across all geometries, achieves the highest lesion sensitivity on an independent brain-metastasis cohort, and the highest brain-parcellation agreement for isotropic and in-plane reconstruction. Reconstruction takes about 6s per volume, adding little overhead relative to acquisition-time savings. GSMR3D offers a flexible approach to MRI scan-time reduction with one model per contrast across geometries while preserving information relevant to downstream tasks.

0.17