CS Paper Radar

Daily listing

2026-09-19 · eess.IV

7 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 7

Scalable SSIM Estimation from PSNR for Per-Title and Context-Adaptive Encoding Workflows

eess.IV cs.MM ·2026-09-19 ·Luc Trudeau, Maria G. Martini
publishedcode/datahot direction
Abstract · Presented at IBC 2026, Amsterdam, The Netherlands. 2026 IBC Technical Paper

Modern streaming pipelines run hundreds of candidate encodes per asset to support per-title encoding, shot-based optimization, and context-adaptive ABR ladder construction. These techniques have moved perceptual quality metrics into the critical path: SSIM and VMAF now guide encoding decisions rather than passively monitor them. We measure that SSIM evaluation accounts for 7-35% of x264 encode time at production speed presets, with the cost ratio rising as encoders run faster. We propose ApproxSSIMate, a low-complexity method for estimating SSIM from PSNR combined with reference-sequence statistics computed once per sequence and reused across every candidate encode. This decouples quality estimation from the encode-decode-compare loop, enabling perceptual quality feedback in live encoding and amortizing quality measurement across candidate encodes in per-title workflows. We validate the approach across H.264/AVC, H.265/HEVC, and AV1 on the Objective-1-fast dataset and release the implementation as free and open-source software.

0.54

SomaNet: Weakly Supervised Learning for Instance Soma Segmentation in 3D Electron Microscopy with Partial Annotations

eess.IV cs.CV ·2026-09-19 ·Mohammad Khateri, Morteza Ghahremani, Jussi Tohka, Alejandra Sierra
code/datahot direction
Abstract · 10 pages, 7 figures, 1 table,

Soma instance segmentation, i.e., identifying and delineating individual cell somas as distinct instances, is crucial for cellular analysis and connectomic reconstruction. Three-dimensional electron microscopy (3D EM) provides nanometer-scale resolution for capturing fine-grained soma morphology. However, dense instance-level manual annotation is prohibitively costly, limiting the scalability of fully supervised methods. To address this challenge, we propose SomaNet, a weakly supervised framework for 3D EM soma instance segmentation under partial annotation constraints. SomaNet adopts a teacher--student learning paradigm tailored to partial labels. The teacher is trained using partially annotated data to generate pseudo-labels, while the student jointly learns from the partial ground-truth annotations and the generated pseudo-labels, progressively recovering dense instance segmentations. To accurately delineate cell somas under limited supervision with varying instance counts, SomaNet incorporates affinity learning, which encourages high similarity within instances and low similarity across instance boundaries. Semantic-guided affinity decoding and 2D-to-3D reconstruction then produce volumetrically consistent 3D soma instances while preserving the large receptive fields of 2D backbones. The framework is architecture-flexible and supports diverse backbones, including vision transformers and foundation models, enabling direct transfer of pretrained visual representations to volumetric EM segmentation. Experiments on 3D EM brain datasets demonstrate that SomaNet achieves accurate and robust soma instance segmentation across regions with diverse soma morphologies under partial annotation. Code is available at https://github.com/mkhateri/SomaNet.

0.51

UQMIA: An Open, Hands-On Tutorial on Uncertainty Quantification in Medical Imaging Analysis with Large Language Model-Based Assessment of Educational Content

eess.IV ·2026-09-19 ·Benyamin Gheiji, Danial Elyassirad, Mahsa Vatanparast, Meysam Tavakoli, Shahriar Faghani
code/data
Abstract

Uncertainty quantification (UQ) is increasingly recognized as an important component of reliable machine learning in medical imaging, yet practical resources connecting UQ theory, implementation, and evaluation remain limited. We developed Uncertainty Quantification in Medical Imaging Analysis (UQMIA), an open-access, hands-on tutorial comprising 19 sessions covering major UQ approaches, including variational inference, Monte Carlo dropout, deep ensembles, evidential deep learning, and conformal prediction, together with methods for evaluating uncertainty reliability. The tutorial is designed for researchers and practitioners with experience in medical imaging, progressing from foundational concepts to implementation and evaluation, with notebooks executable through Kaggle. Beyond presenting the tutorial, we introduce a framework using large language models (LLMs) to evaluate whether technical educational resources contain retrievable and usable knowledge. Using 100 four-option multiple-choice questions derived from primary methodological literature, we evaluated 20 instruction-tuned LLMs from six model families with and without retrieved tutorial context. Retrieval of UQMIA improved accuracy in 18 of 20 models, increasing mean accuracy from 0.680 to 0.742 (+0.062; Holm-adjusted P=0.00032), and improved area under the receiver operating characteristic curve (AUROC) in 18 of 20 models, increasing from 0.725 to 0.788 (+0.063; Holm-adjusted P=0.00032). UQMIA provides an accessible resource for learning UQ in medical imaging and demonstrates an LLM-based approach for evaluating technical educational material. The tutorial is available at https://benyamin-gheiji.github.io/Uncertainty-Quantification-Medical-Imaging-Analysis/ and its source code and notebooks at https://github.com/benyamin-gheiji/Uncertainty-Quantification-Medical-Imaging-Analysis/.

0.46

DA-Lion: Efficient Neural Video Representation via Direction-Aware Optimization

eess.IV ·2026-09-19 ·Qingyu Mao, Jiacong Chen, Shuai Liu, Yongsheng Liang, Youneng Bao
code/data
Abstract · PRCV2026

Implicit neural video representation (NVR) encodes a video as the parameters of an overfitted neural network, where training and testing data are identical and the objective is instance-specific signal fitting. In this deterministic regime, optimization dynamics directly determine reconstruction quality under a fixed budget, yet existing methods universally adopt general-purpose optimizers designed for stochastic gradient training. Adam-family optimizers descend steadily but converge slowly, while Lion achieves faster early progress but oscillates markedly in later stages when gradient directions become unstable. We trace this instability to the insensitivity of the sign-based update to gradient--momentum alignment. To address this, we propose Direction-Aware Lion (DA-Lion), a task-driven optimizer tailored for NVR. DA-Lion introduces (i) a direction-consistency criterion that switches between sign update and momentum update based on gradient--momentum alignment, and (ii) a learning-rate-aware magnitude modulation that stabilizes effective step sizes across training phases. DA-Lion modifies only the parameter update rule, preserving model architecture, parameter count, FLOPs, and decoding throughput. Experiments on three datasets with four NeRV-family backbones show that DA-Lion improves convergence stability and boosts PSNR/MS-SSIM across all backbones. The source code will be made available at https://github.com/maoqingyu1996/DA-Lion.

0.41

Signal recovery in the polychromatic computed tomography model: Injectivity and complexity

eess.IV cs.ITeess.SPphysics.med-ph ·2026-09-19 ·Xuanzhou Chen, Ashwin Pananjady
Abstract · 9 pages

We consider a nonlinear model motivated by polychromatic computed tomography (CT). Here, $W$ distinct $d$-dimensional signals $x^*_1, \ldots, x^*_W \in \mathbb{R}^d$ must be recovered from $n$ measurements $(a_i, y_i)_{i = 1}^n$ that obey the nonlinear model $\mathbb{E}[y_i|a_i] = h(\langle a_i, x^*_1 \rangle, \ldots, \langle a_i, x^*_W \rangle)$, where $h: \mathbb{R}^W \to \mathbb{R}$ is a known nonlinearity that models a certain type of exponential attenuation law. Even when there is no noise in the measurements, the sample size $n$ (for any measurement ensemble $\{a_i\}_{i = 1}^n$) must exceed the number of unknowns $Wd$ to guarantee that the underlying signals are identifiable. We construct a measurement ensemble that ensures perfect signal recovery almost surely provided $n \geq Wd + W - 1$, thereby isolating the injectivity threshold up to an additive factor $W - 1$. We also study computational complexity of signal recovery in this model with a general measurement ensemble $\{a_i\}$. We show that if $W \geq 2$, then there is a measurement ensemble for which deciding whether there exist signals consistent with the measurements is NP-hard. In particular, this implies that polychromatic, multimaterial CT reconstruction is NP-hard in general. This finding stands in sharp contrast to the single-material setting, for which a polynomial-time algorithm can provably perform signal recovery for any measurement ensemble.

0.32

Quality Assessment of 3D Gaussian Splatting: Distortions, Benchmarks, and Open Challenges

eess.IV ·2026-09-19 ·Shuai Liu, Binqiang Liu, Qingyu Mao, Jiacong Chen, Yongsheng Liang +1 more
publishedsurvey
Abstract · Published in: 2026 11th International Conference on Image, Vision and Computing (ICIVC)

3D Gaussian Splatting (3DGS) has become a practical scene representation for real-time novel-view rendering, compression, and immersive content delivery. However, its quality assessment still largely follows rendered-view proxy protocols that sample camera poses, render images or videos, and apply inherited image and video quality metrics. While convenient, this practice does not fully capture 3DGS-native degradations that originate from Gaussian primitive distributions, splatting and visibility behavior, and trajectory-dependent artifacts. This survey reviews recent 3DGS quality assessment studies from four perspectives, covering distortion characteristics, subjective benchmarks, objective metric reliability, and emerging directions for native 3DGS evaluation. Across the literature, we find that different benchmarks construct different notions of quality, and that metric effectiveness is highly protocol dependent, varying with distortion sources, stimulus formats, and view and trajectory sampling. Finally, we summarize open challenges and outline practical guidelines for building more comparable and representative 3DGS-QA evaluations.

0.31

A Controlled Evaluation of Quantum Correlation Refinement for Few-Shot Semantic Segmentation: Resource Cost and IBM Quantum Hardware Validation

eess.IV ·2026-09-19 ·Hina Shakir, Muhammad Irfan Memon, Asia Samreen, Javeed Hussain, Syed Rizwan Ali +2 more
Abstract

PQCs are increasingly proposed as trainable components in classical ML pipelines, but rarely characterized alongside a controlled measurement of task-level benefit. We report such an evaluation, using few shot segmentation as testbed. We integrate a Quantum Correlation Refiner (QCR), a six-qubit variational circuit with amplitude embedding and a gated residual connection into a classical correlation-based architecture, under the four fold PASCAL 5i protocol, three seeds per fold, against an unrefined baseline and a matched MLP refiner. Across 12 fold-seed comparisons, QCR changes mIoU by only +0.0001 (t(11)=0.10, p=0.92, dz=0.03); the MLP control and an expanded Pauli-measurement variant show similarly no improvement. QCR adds just 473 parameters but roughly doubles per epoch training time. A trained circuit on IBM hardware (18 patches) agrees closely with the noiseless simulator (r=0.954, MAE=0.101), a fidelity check, not an accuracy gain. The module is functional, trainable, and hardware deployable, yet shows no task-level advantage over a matched classical alternative under this regime, a template for evaluating quantum components jointly via matched controls, repeated seeds, resource measurement, and hardware validation, rather than any one alone.

0.24