CS Paper Radar

Daily listing

2026-10-12 · eess.IV

3 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 3

Hybrid Context Forests and Bilateral Viterbi Matching for 3D Rib Centerline Tracing in CT

eess.IV cs.CVq-bio.TO ·2026-10-12 ·Quan Wang
benchmarkcode/data
Abstract

Automatic extraction and anatomical numbering (R01-R12, L01-L12) of all 24 rib centerlines in thoracic CT is essential for unfolded rib visualization, fracture detection, and surgical navigation, but remains challenging due to adjacent-bone confluence, calcified costal cartilage bridges, kyphotic pose variation, and partial visibility of terminal ribs. We present ribline, an open-source three-stage framework combining: (1) an automatically detected lung-apex and vertebral-midline coordinate frame with a kyphosis-aware azimuthal angle for point ordering along each rib; (2) a hybrid voxel detector fusing an anatomically anchored Semantic Context Forest (SCF) with a lightweight 3D U-Net; and (3) a global stage that decomposes the probability skeleton into candidate curves, assigns rib indices via a bilateral Viterbi dynamic program coupled across both hemithoraces, and refines curves via template recovery and normal-plane centering (RibSnake). On the Siemens Corporate Research 2 mm thoracic CT benchmark (47 training and 12 evaluation scans), our pipeline achieves a labeled Chamfer distance of 2.05 mm, labeled clDice of 0.886 (3 mm) and 0.945 (4 mm), 97.2% labeling accuracy (278/286 ribs), and zero false-positive curves on the evaluation split, and 3.64 mm (median 2.39 mm) with 91.8% labeling accuracy across all 59 annotated scans (1,402 ribs) in 5-fold cross-validation. Code: https://github.com/wq2012/ribline Pretrained Models: https://huggingface.co/collections/wq2012/ribline

0.37

Calibrating Generative Flows through Regional Probability Matching

eess.IV ·2026-10-12 ·Yubo Huang, Xiongyu Hu, Xin Lai, Zixi Wang, Liao Jian +2 more
benchmarkhot direction
Abstract

Generative models offer a powerful route to scientific simulation and discovery by enabling the study of complex populations and rare phenomena. Flow matching can generate realistic samples, yet inaccurate occurrence frequencies can distort population statistics and compromise inferences about rare events. Here we developed generalized mass-preserving coupled flow matching (G-MPCF), which matches the probability masses of Gaussian source regions to those of weighted data regions. This construction encodes the desired regional frequencies in the correspondence between noise and observations, shaping the learned dynamics while preserving the prescribed target distribution. On a rare-mode benchmark, G-MPCF reduces relative score error by 95.0% and numerical integration error by 89.9% compared with independent flow matching. On CIFAR-10 with a 100:1 class-probability ratio, it reduces corrected class-mass error by 44.6% compared with minibatch optimal transport, while improving mean image fidelity with matched computational budgets. We envision that incorporating regional probability calibration into generative modelling will support more reliable scientific simulation and inference, enabling the study of systems in which rare events and their occurrence frequencies are central to understanding the underlying mechanisms.

0.32

Uncertainty-Aware Cortical Surface Reconstruction and Spherical Registration for Heterogeneous Brain MRI

eess.IV cs.CV ·2026-10-12 ·Jesper Duemose Nielsen, Karthik Gopinath, Andrew Hoopes, Adrian Dalca, Axel Thielscher +2 more
Abstract

Surface-based cortical analysis is useful in many applications as it is a natural way to model the highly folded structure of the cerebral cortex, allowing quantities such as curvature and thickness to be easily calculated. Existing deep learning (DL) methods have focused on 1x1x1 mm3 T1-weighted (T1w) scans, thus replicating classical pipelines. Here we present a neural network that is trained exclusively on synthetic scans with random contrast and resolution. Consequently, it can be applied to almost any kind of magnetic resonance imaging (MRI) scan. In addition, our model provides vertex-wise uncertainty estimates of the predicted surface as well as a spherical registration to fsaverage space. Our model performs on par with other state-of-the-art DL methods on 1x1x1 mm3 T1w scans and outperforms the only other method capable of estimating cortical surfaces from low resolution, non-T1w scans. The predicted uncertainty, moreover, correlates with overall scan quality on low resolution scans and highlights areas of poor surface reconstruction on 1x1x1 mm3 T1w scans, suggesting that it can be used for quality control. Finally, the predicted spherical registrations prove comparable to other DL and classical registration methods. These qualities, when combined with the fast inference time, will provide the ability to analyze large, existing databases of clinical MRI scans, with the potential for finding disease-specific patterns that would otherwise be infeasible in a research setting.

0.29