CS Paper Radar

Hybrid Context Forests and Bilateral Viterbi Matching for 3D Rib Centerline Tracing in CT

Quan Wang

eess.IV cs.CVq-bio.TO ·submitted 2026-10-12 01:39 UTC · v2
benchmarkcode/data

Abstract

Automatic extraction and anatomical numbering (R01-R12, L01-L12) of all 24 rib centerlines in thoracic CT is essential for unfolded rib visualization, fracture detection, and surgical navigation, but remains challenging due to adjacent-bone confluence, calcified costal cartilage bridges, kyphotic pose variation, and partial visibility of terminal ribs. We present ribline, an open-source three-stage framework combining: (1) an automatically detected lung-apex and vertebral-midline coordinate frame with a kyphosis-aware azimuthal angle for point ordering along each rib; (2) a hybrid voxel detector fusing an anatomically anchored Semantic Context Forest (SCF) with a lightweight 3D U-Net; and (3) a global stage that decomposes the probability skeleton into candidate curves, assigns rib indices via a bilateral Viterbi dynamic program coupled across both hemithoraces, and refines curves via template recovery and normal-plane centering (RibSnake). On the Siemens Corporate Research 2 mm thoracic CT benchmark (47 training and 12 evaluation scans), our pipeline achieves a labeled Chamfer distance of 2.05 mm, labeled clDice of 0.886 (3 mm) and 0.945 (4 mm), 97.2% labeling accuracy (278/286 ribs), and zero false-positive curves on the evaluation split, and 3.64 mm (median 2.39 mm) with 91.8% labeling accuracy across all 59 annotated scans (1,402 ribs) in 5-fold cross-validation. Code: https://github.com/wq2012/ribline Pretrained Models: https://huggingface.co/collections/wq2012/ribline

Closest papers

Nearest neighbours by meaning across the whole index.

Sub-Voxel Displacement and Ipsilateral Territory Decoupling for 3D Bilateral Coronary Artery Tree Reconstruction in Cardiac CT Angiography

cs.CV q-bio.TO ·2026-10-05 ·Zeyu Jia, Xin Ming
similarity 0.64
Abstract · 18 pages, 4 figures, 7 tables; includes combined Supplementary Material (Algorithms A1-A5 and Tables S1-S5)

Reconstructing topologically complete, sub-voxel-accurate 3D bilateral coronary artery trees from cardiac CT angiography (CCTA) requires simultaneously recovering continuous centerline trajectories and separating dense left/right coronary territories without cross-ostial collisions. We present a five-stage tubular drift and ipsilateral territory decoupling framework (M1-M5). Stage M1 pairs a 398,843-parameter multi-scale 3D pyramid encoder with a four-head tubular field network predicting vesselness probability, signed tubular boundary distance, unit tangent vectors, and continuous 3D centripetal displacement vectors. Stage M2 introduces recall-preserving multi-task optimization with 7-group AdamW parameter decoupling, L2-SP backbone regularization, and per-step anchor shrinkage. Stage M3 calibrates cylindrical Valsalva-sinotubular-junction wall coordinates and native-resolution orifice contact expectations for robust left and right ostial rooting. Stage M4 constructs a scalar-potential-weighted minimum-cost arborescence followed by normal-plane cross-sectional pullback and centripetal trajectory pruning. Stage M5 enforces coverage-guarded ipsilateral-field-coupled bilateral collision reduction and subtree handover. Across a 14-case held-out development cohort (Dev-14, 17-arm forward incremental build and 9-arm leave-one-out ablation) and an independent 50-case out-of-sample evaluation cohort (OOS-50) benchmarked against seven external architectures (nnU-Net, 3D UX-Net, Swin-UNETR, MedNeXt, CS2-Net, clDice-UNet, and Point-UNet), M1-M5 reduces bilateral chamfer distance on Dev-14 from 3.4381 mm to 2.2759 mm and achieves 2.7671 mm on OOS-50 with 7.11% bilateral collision rate and 79.7% distal branch completeness.

0.29

DUNEDepth: Bronchoscopic Depth and Pose Estimation via Hybrid Adaptation of a 3D-Vision Foundation Model

eess.IV cs.CV ·2026-11-02 ·Qi Chang, Austin Kao, Ange Lou, William E. Higgins
published similarity 0.61
Abstract · 10 pages, 4 figures, 3 tables. Accepted to MICAD 2026 (International Conference on Medical Imaging and Computer-Aided Diagnosis), Edinburgh,…

State-of-the-art bronchoscopy guidance systems and computer-aided diagnosis methods have emerged as important tools for early lung cancer detection. Effective use of these tools depends on being able to accurately link a patient's bronchoscopic airway exam video to their pre-operative 3D chest CT scan. Unfortunately, the derivation of such links, which include bronchoscope depth and camera motion, from the exam video remains an open problem. Building on recently proposed 3D-vision foundation models, we propose DUNEDepth, a hybrid architecture that combines a shared DUNE ViT encoder, a twin MASt3R cross-attention decoder structure, and a prediction head that includes elements of the MASt3R and Reloc3r models. To fine-tune the architecture to our application, we utilize an integrated hybrid synthetic-supervised/self-supervised training strategy that draws on both bronchoscopic video and CT-derived virtual bronchoscopic views. Experiments drawing on bronchoscopic video sequences demonstrate that DUNEDepth more accurately derives depth information and camera motion trajectories than previously proposed self-supervised methods.

0.31

ARC-CT: Anatomy-Routed Contrastive Vision-Language Learning for 3D Chest CT

cs.CV cs.AI ·2026-08-28 ·Huseyin Umut Isik, Mehmet Alp Ozaydin, Sila Kurugol, Şeyda Ertekin
publishedcode/data similarity 0.61
Abstract · Accepted to the Thoracic Image Analysis (TIA) Workshop at MICCAI 2026

Contrastive vision-language learning uses paired chest CT volumes and radiology reports to learn abnormality classifiers without manually annotated labels. However, two characteristics of chest CT challenge conventional global contrastive learning. First, many critical abnormalities are small or anatomically localized, and pooling an en- tire volume into a single embedding may dilute their visual evidence. Second, the standard contrastive objective treats every other scan in a batch as a negative. Because many chest CTs share abnormalities, this objective incorrectly pushes co-positive pairs apart. We propose Anatomy-Routed Contrastive Learning for 3D Chest CT (ARC-CT), a region-aware framework that addresses these limitations using only la- bels extracted from reports by an LLM, with no manual annotations or bounding boxes. ARC-CT combines three components: (1) an Anato- myQFormer localizing evidence via queries constrained by automatically generated organ masks; (2) a label-Jaccard soft InfoNCE objective in- tegrating the standard one-hot target with the label-set overlap of each pair, which reduces false-negative penalties between studies that share clinical findings; and (3) an organ-level alignment loss connecting mask- pooled visual features to organ-specific report text extracted offline with a large language model. ARC-CT achieves a 0.86 mask-free macro AUC across 18 abnormalities using a compact 3D ResNet-18 backbone. Over- all, ARC-CT outperforms both comparable efficient baselines and sev- eral larger transformer models. Our code and weights are available at https://github.com/arc-ct/arc-ct.

0.62

OcTreeMamba: Topology-Aware Mamba for 3D Medical Segmentation via Octree Sparsification

cs.CV ·2026-11-05 ·Kaixiang Mai, Jiaqi Yu, Yuzhu Ji, Yiqun Zhang, Zhijie Wang +2 more
publishedbenchmarkcode/data similarity 0.60
Abstract · 8 pages, 5 figures, accepted by IEEE BIBM 2026

Accurate segmentation of 3D anatomical structures is crucial to medical image analysis. Recently, Mamba-based approaches have achieved promising segmentation performance in capturing long-range dependencies with linear-time computational complexity. However, heuristic selective scanning strategies inherently disrupt the intrinsic spatial hierarchy and increase computational redundancy, ignoring the inherent sparsity of 3D anatomical structures. To this end, we propose OcTreeMamba, a hierarchical framework that incorporates Octree structures into SSM, achieving 3D topology-aware long-range context feature propagation and integration. Specifically, a Structure Learner performs anatomy-adaptive structured sparsification through hierarchical gating and Gumbel-Softmax sampling, enabling differentiable selection of anatomical regions. The selected regions are subsequently organized by a Dynamic Octree Builder into a multi-level topology that preserves their hierarchical connectivity. Based on the constructed Octree, a bidirectional Tree-SSM propagates and integrates contextual features along connectivity-aware leaf--parent--root and root--parent--leaf trajectories. Extensive experiments on four benchmark datasets show that our proposed OcTreeMamba achieves competitive performance \wrt topological continuity and computational efficiency, particularly for recovering the complex structure on vascular datasets. The code is available at https://github.com/MikeMak123/OcTreeMamba.

0.47

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.60
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32

Anatomy-Change-Aware Bidirectional Selective State-Space Memory for Clinically Deployed Thoracic Radiotherapy Auto-Contouring

eess.IV cs.CV ·2026-09-11 ·Galib Ahmed, Istiak Ahmed, Aritra Islam Saswato, Asib Mostakim Fony, Kazi Shahriar Sanjid +13 more
similarity 0.60
Abstract

We developed DAMM-Net++, a 2.5D architecture for thoracic OAR and target volume segmentation that addresses three persistent challenges in radiotherapy auto-contouring: inter-slice surface incoherence, systematic failure on small low-contrast targets, and the absence of per-case reliability signals. The central component is an anatomy-change-aware bidirectional selective state-space memory that models through-plane anatomical change and selectively propagates context along the axial slice sequence. A boundary-aware decoder sharpens near-surface predictions, and an uncertainty head provides calibrated per-voxel confidence for clinical triage. We evaluated 2,146 patients across four centers, an independent external cohort of 112 patients, and a multicenter reader study involving 17 radiation oncologists on 305 cases. The model achieves a mean Dice of 0.955 and HD95 of 3.78 mm, with the largest gains on low-contrast organs-at-risk (OARs) and target volumes where through-plane context is most critical. The uncertainty head is well-calibrated and supports case-level triage. In the reader study, AI assistance reduced contouring time by 75-80% across experience levels and raised junior-reader IoU from 0.861 to 0.925, matching the unedited model. External validation showed a modest internal-to-external drop (< 5%) with calibrated uncertainty transferring without recalibration. The complete deployment pipeline from DICOM ingestion to TPS-compatible RTSTRUCT export has been integrated into the clinical workflow at a partner hospital, where it is used to assist with contouring. These results suggest that anatomically motivated inter-slice memory, paired with uncertainty-guided review, offers a clinically viable path for thoracic auto-contouring.

0.20

Raysemble: Metric 3D Bone Reconstruction from a Single X-ray

cs.CV ·2026-11-12 ·Xiaoyang Li, Xinghao Yan, Yuan Chai
similarity 0.59
Abstract

Raysemble reconstructs eight lumbar and pelvic bones from a single X-ray by separating shape and placement. Each 3D query samples regional and global features at its image projection. A shared decoder predicts normalized bone shapes. Predicted depth and camera geometry determine 3D centers and scales for resampling these shapes onto a common grid in millimeters. Evaluation uses 23 held-out patients with 43 CT scans, each generating one simulated anteroposterior radiograph. Without rigid alignment to CT,Raysemble leads 15 evaluated methods, averaging 65.24% Dice, 9.09 mm HD95, and 3.32 mm ASSD over three random seeds. With identical inputs, it improves Dice over VolumeNeRF by 5.86 percentage points.

0.21

PPCAR-Net: Projection-Refined Parametric 3D Coronary Artery Reconstruction from Sparse X-ray Angiographic Views

cs.CV ·2026-10-07 ·Yu Ren, Hwee Kuan Lee, Tat-Jen Cham, Jonathan Yap, Khung Keong Yeo
code/data similarity 0.59
Abstract · 22 pages, 5 figures, 10 tables, including references and appendix. Code and pretrained models: https://github.com/G2304138H/PPCAR-Net . Proj…

Sparse-view 3D coronary reconstruction commonly relies on cross-view correspondence and triangulation, which are vulnerable to vessel overlap and foreshortening, or on volumetric prediction followed by vascular-graph extraction, which does not directly provide centrelines and radii. We introduce PPCAR-Net, a projection-refined parametric coronary artery reconstruction network that directly predicts a branch-structured centreline-and-radius representation without explicit point matching, triangulation, or an intermediate volume. Given a variable number of segmented views, a coarse predictor combines frozen VGGT features with learned branch queries to estimate branch presence, B-spline centreline trajectories, and dense radius profiles. Projection-guided geometry and radius refiners then sample local evidence from the input views and apply residual corrections learned with 3D supervision. We evaluate representation fidelity and sparse-view reconstruction quantitatively and qualitatively. On simulated angiographic masks generated from CT-derived coronary anatomy, PPCAR-Net produces better connected artery reconstructions and achieves strong centreline accuracy, particularly for RCA, while maintaining competitive volumetric overlap. Coarse-to-fine inference takes 121 ms, enabling real-time reconstruction.

0.29