CS Paper Radar

Raysemble: Metric 3D Bone Reconstruction from a Single X-ray

Xiaoyang Li, Xinghao Yan, Yuan Chai

cs.CV ·submitted 2026-11-12 14:38 UTC · v2

Abstract

Raysemble reconstructs eight lumbar and pelvic bones from a single X-ray by separating shape and placement. Each 3D query samples regional and global features at its image projection. A shared decoder predicts normalized bone shapes. Predicted depth and camera geometry determine 3D centers and scales for resampling these shapes onto a common grid in millimeters. Evaluation uses 23 held-out patients with 43 CT scans, each generating one simulated anteroposterior radiograph. Without rigid alignment to CT,Raysemble leads 15 evaluated methods, averaging 65.24% Dice, 9.09 mm HD95, and 3.32 mm ASSD over three random seeds. With identical inputs, it improves Dice over VolumeNeRF by 5.86 percentage points.

Closest papers

Nearest neighbours by meaning across the whole index.

Shape-guided Gaussian Splatting for Sparse-View X-ray 3D Reconstruction

cs.CV ·2026-09-09 ·Pranav Poudel, Florence Dell'Aniello Picard, Nairouz Shehata, Frédéric Lavoie, Herve Lombaert
publishedcode/data similarity 0.64
Abstract · Accepted at: Off-Grid: 1st Workshop on Continuous Representations and Grid-Free Methods in Medical Imaging, MICCAI 2026

Sparse-view X-ray 3D reconstruction is essential for reducing radiation exposure, but recovering a density field from a handful of X-ray projections is severely ill-posed. Recently, 3D Gaussian Splatting has achieved state-of-the-art performance in sparse-view reconstruction by representing the volume using explicit, optimized primitives, but it requires dozens of projected views. With fewer views, reconstruction quality degrades severely since the explicit primitives are optimized freely without any anatomical information. Anatomical structures, in contrast, share similar geometry and density across a population. Their variations are bounded within a limited range that statistical shape models can capture. This paper proposes a shape-guided Gaussian splatting framework for sparse-view X-ray 3D reconstructions. Our contribution lies in driving Gaussian positions toward anatomically valid configurations, alongside atlas-based density regularization. Our method ensures anatomically consistent reconstruction and improves PSNR by 2.83 dB over a state-of-the-art Gaussian splatting baseline with as few as 5 views. Code Available: https://github.com/polyshape-lab/ShapeGuidedGaussian

0.46

Learning Where and What to Lift for Bi-planar X-ray-to-CT Reconstruction

cs.CV cs.AI ·2026-08-18 ·Yifei Wu, Yicheng Wu, Qiang Ma, Qi Chen, Renyang Gu +3 more
similarity 0.61
Abstract

X-ray imaging can be approximately modeled as the projection of an underlying volumetric attenuation field, with each measurement recording the accumulated attenuation along a corresponding ray path. Reconstructing a CT volume from only a few X-ray views is therefore severely ill-posed, as the projections collapse depth information and leave 3D locations of anatomical regions and their corresponding intensity distributions highly entangled and ambiguous. We observe that once the spatial organization of anatomical regions is established, estimating their CT intensities becomes substantially more tractable. Motivated by this, we propose LiftXR, an interleaved, geometry-guided framework that explicitly incorporates spatial layout recovery into CT reconstruction. Specifically, a layout lifter first generates a 3D anatomical layout from bi-planar X-rays, providing spatial guidance for an intensity renderer to reconstruct a CT volume. An anatomical parser then performs volumetric perception on the reconstruction, exploiting its spatially resolved boundary and intensity cues to recover a refined anatomical layout. This transition from projection-conditioned layout generation to reconstruction-conditioned anatomical perception allows the parsed layout to provide feedback for region-specific intensity calibration. Extensive experiments on two public datasets demonstrate that LiftXR consistently outperforms recent X-ray-to-CT reconstruction methods, establishing a new state of the art. Moreover, the reconstructed CT achieves superior performance in external downstream segmentation, indicating improved anatomical fidelity. Code will be released.

0.22

ARNAI: Artifact Removal Network based on Autoencoding and Inpainting for Robust Spinal Image Segmentation and Measurement

cs.CV cs.AI ·2026-09-07 ·Sang-Jin Park, Jinyoung Choi, Seokwon Kim, Seungeon Song, Insu Park +11 more
top venue similarity 0.61
Abstract · 12 pages 4 figures

Purpose: This study aims to develop an AI framework applicable for postoperative imaging for automated measurement of spinopelvic parameters on radiographs with robustness to the presence of spinal implants. Materials and Methods: We retrospectively reviewed lateral lumbar spine radiographs from two institutions (Internal: January 2017--December 2024; External: October 2021--September 2025). We developed the Restore, Segment, and Measure (RSM) framework, incorporating a novel Artifact Removal Network based on Autoencoding and Inpainting (ARNAI) to mitigate implant-related artifacts in postoperative radiographs. Segmentation and spinopelvic parameter (PT, LL, SS, SCA) measurement performance were assessed using Wilcoxon signed-rank tests and intraclass correlation coefficients. Results: When ARNAI was added to a recent Transformer-based segmentation model, FCBFormer, the mean DSC increased to 0.870 from 0.814, with marked gains at L3--L5 and smaller improvements at L1--L2. On 91 radiographs with implants, the mean L4--L5 segmental Cobb angle error decreased to 4.7 ° from 15.6--16.2 °, an average error reduction of 70%. The ICC for L4--L5 segmental Cobb angle improved to 0.54 (Rater 1) and 0.59 (Rater 2) from 0.18, and ICCs for pelvic tilt, lumbar lordosis, and sacral slope all exceeded 0.70. The improvement in L4--L5 segmental Cobb angle error was statistically significant in the internal implant-containing cohort after correction for multiple comparisons. Conclusion: The proposed RSM framework improved automated spinopelvic parameter measurement in implant-containing postoperative radiographs. By mitigating implant-related artifacts, ARNAI improved segmentation and downstream measurement accuracy, with the greatest benefit observed for L4--L5 segmental Cobb angle estimation, where the mean error was reduced by approximately 70%.

0.51

FleXray: Universal Clinical X-ray Segmentation

cs.CV cs.AI ·2026-09-22 ·Victor Ion Butoi, Vivek Gopalakrishnan, John V. Guttag, Adrian V. Dalca, Neel Dey
similarity 0.60
Abstract · 35 pages, 12 figures, 10 tables. Code, models, data, and a browser-based demo at https://flexray.csail.mit.edu

X-ray is medicine's most widely used imaging modality, yet remains among its least quantitative. Unlike volumetric modalities like CT or MRI, X-ray collapses 3D anatomy into a 2D projection, causing structures to overlap and anatomical boundaries to be ambiguous, even to experts. As a result, labeling X-ray databases for training general-purpose segmentation systems is impractical, leaving morphometric and functional X-ray analysis confined to narrow anatomical regions and applications. To this end, we present FleXray, a generalist model for anatomical segmentation across the entire body in clinical X-rays. Instead of curating large, manually annotated X-ray datasets, we build a scalable, physics-based generative X-ray data engine. Using existing 3D whole-body CT segmentation datasets and generative image-editing models, we simulate fully-annotated 2D X-rays with diverse appearances, physiological properties, and imaging geometries. Trained on these simulations, FleXray accurately segments 60 anatomical structures across unseen research datasets and in-the-wild X-rays. We further show that FleXray makes X-rays directly amenable to quantitative analysis, enabling automated measurements for disease grading, robust navigation during X-ray-guided interventions, and data-efficient learning of pathological targets. We release the model, code, a full-body X-ray segmentation dataset, and a local, easy-to-use browser-based tool at https://flexray.csail.mit.edu .

0.27

MRI-to-CT Translation of Spinal Images via Anatomy-Guided Pseudo-Pairing and Adversarial Diffusion

cs.CV cs.AI ·2026-10-27 ·Eduardo Nieto, Ibai Genua, Davide Scorza, Karen López-Linares
similarity 0.60
Abstract

Magnetic Resonance Imaging (MRI) is routinely used to diagnose spinal disorders, but surgical planning often requires Computed Tomography (CT) for better visualization of vertebral bone anatomy. Synthesizing CT from MRI could avoid additional radiation exposure and streamline preoperative assessment. We propose a three-stage framework for spine MRI-to-CT synthesis. First, an anatomy-guided vertebral matching system identifies similar sagittal MRI and CT slices using spine segmentations and aligns them through rigid registration, creating pseudo-paired data from unpaired scans. Second, these pairs train an adversarial diffusion model for MRI-to-CT translation. Third, synthesized slices are assembled into 3D volumes and refined by a network that improves inter-slice continuity and structural coherence. The framework was trained on over 10,000 unpaired sagittal MRI and CT slices and evaluated on 1,911 slices from 83 MRI volumes spanning all spinal regions. Assessment combined distribution-based measures with vertebral segmentation metrics. Compared with diffusion alone, the proposed approach increased binary 3D vertebral Dice from 0.666 to 0.739. Volumetric post-processing reduced visible discontinuities between stacked slices and improved vertebral coherence in axial and coronal views. Combining anatomy-guided pseudo-pairing, adversarial diffusion and 3D refinement improves spine MRI-to-CT synthesis. Vertebral matching primarily enhanced anatomical alignment and fidelity, while volumetric refinement improved 3D consistency. These findings support further development of MRI-derived CT-like visualization for preoperative planning, particularly to preserve fine intensity details while maintaining volumetric coherence.

0.16

XPos3R: Cross-Modal Transformer for Intraoperative 2D/3D Registration

eess.IV ·2026-09-09 ·Shiyan Su, Ruyi Zha, Hongdong Li, Xuelian Cheng, Zongyuan Ge
top venue similarity 0.60
Abstract · Accepted to ECCV 2026

Intraoperative 2D/3D registration, which aligns live X-ray images with preoperative volumes, is essential for image-guided interventions. Previous regression-based methods suffer from limited generalization, thus requiring time-consuming patient-specific retraining. Inspired by recent geometry foundation models such as DUSt3R, we propose XPos3R, a generalizable pose regression method that eliminates preoperative preparation. Unlike existing geometry models designed for homogeneous inputs, XPos3R extends this paradigm to multi-modal inputs, namely 2D X-rays and 3D volumes. Specifically, we introduce an asymmetric encoder-decoder architecture that improves cross-modal feature alignment while maintaining computational efficiency. To scale training under limited medical data, we adopt an anatomy-specific data curation strategy and construct million-scale synthetic datasets. Evaluated on real-world benchmarks, a single pretrained XPos3R surpasses patient-specific methods in both accuracy and robustness. With test-time optimization completed in seconds, it further reduces the 3D error to <4 mm and the reprojection error to <1 mm. The strong generalization, accuracy, and efficiency of XPos3R highlight its clinical potential, while its asymmetric framework may inspire broader cross-modal vision geometry tasks.

0.47

Hybrid Context Forests and Bilateral Viterbi Matching for 3D Rib Centerline Tracing in CT

eess.IV cs.CVq-bio.TO ·2026-10-12 ·Quan Wang
benchmarkcode/data similarity 0.59
Abstract

Automatic extraction and anatomical numbering (R01-R12, L01-L12) of all 24 rib centerlines in thoracic CT is essential for unfolded rib visualization, fracture detection, and surgical navigation, but remains challenging due to adjacent-bone confluence, calcified costal cartilage bridges, kyphotic pose variation, and partial visibility of terminal ribs. We present ribline, an open-source three-stage framework combining: (1) an automatically detected lung-apex and vertebral-midline coordinate frame with a kyphosis-aware azimuthal angle for point ordering along each rib; (2) a hybrid voxel detector fusing an anatomically anchored Semantic Context Forest (SCF) with a lightweight 3D U-Net; and (3) a global stage that decomposes the probability skeleton into candidate curves, assigns rib indices via a bilateral Viterbi dynamic program coupled across both hemithoraces, and refines curves via template recovery and normal-plane centering (RibSnake). On the Siemens Corporate Research 2 mm thoracic CT benchmark (47 training and 12 evaluation scans), our pipeline achieves a labeled Chamfer distance of 2.05 mm, labeled clDice of 0.886 (3 mm) and 0.945 (4 mm), 97.2% labeling accuracy (278/286 ribs), and zero false-positive curves on the evaluation split, and 3.64 mm (median 2.39 mm) with 91.8% labeling accuracy across all 59 annotated scans (1,402 ribs) in 5-fold cross-validation. Code: https://github.com/wq2012/ribline Pretrained Models: https://huggingface.co/collections/wq2012/ribline

0.37

Bridging the Markerless Tracking Validation Gap: Intraoperative X-ray Workflow Integration

cs.CV ·2026-10-15 ·Connor Daly, Salvatore Russo, Jinendra Ekanayake, Daniel S. Elson, Ferdinando Rodriguez y Baena
top venue similarity 0.59
Abstract · This version was submitted to MICCAI 2026 for review, see journal reference for published version

Markerless intraoperative tracking of spinal anatomy via RGB-D sensors is a promising alternative to invasive bone-anchored fiducials, yet no existing clinical dataset provides independent subsurface ground truth for validating these methods. We address this gap with a clinically viable pipeline that derives per-vertebra 6-DoF pose from routine intraoperative C-arm fluoroscopy, co-registered to the RGB-D camera frame through a multimodal fiducial array detectable in both imaging modalities. Critically, the pipeline requires no additional radiation, instrumentation, or deviation from standard surgical workflows, relying solely on the fluoroscopic images already acquired during routine level checks. A calibrated transform chain links the vertebral pose recovered via multi-view 2D-3D CT-to-fluoroscopy registration to the RGB-D coordinate frame, enabling direct comparison of any markerless registration estimate against a subsurface reference. Ex vivo validation against optically tracked ovine vertebrae confirms end-to-end accuracy of 2.06 +- 0.29 mm and 3.35 +- 0.93 degrees, sufficient to serve as independent ground truth for methods with substantially larger errors. We demonstrate the pipeline's utility by evaluating two markerless registration strategies on clinical data spanning 11 vertebrae across 1,500 frames from three surgical sequences: the first such evaluation against an independent subsurface reference in a clinical setting. The proposed framework provides reusable infrastructure for benchmarking emerging markerless tracking methods on real surgical data.

0.42