Abstract

State-of-the-art bronchoscopy guidance systems and computer-aided diagnosis methods have emerged as important tools for early lung cancer detection. Effective use of these tools depends on being able to accurately link a patient's bronchoscopic airway exam video to their pre-operative 3D chest CT scan. Unfortunately, the derivation of such links, which include bronchoscope depth and camera motion, from the exam video remains an open problem. Building on recently proposed 3D-vision foundation models, we propose DUNEDepth, a hybrid architecture that combines a shared DUNE ViT encoder, a twin MASt3R cross-attention decoder structure, and a prediction head that includes elements of the MASt3R and Reloc3r models. To fine-tune the architecture to our application, we utilize an integrated hybrid synthetic-supervised/self-supervised training strategy that draws on both bronchoscopic video and CT-derived virtual bronchoscopic views. Experiments drawing on bronchoscopic video sequences demonstrate that DUNEDepth more accurately derives depth information and camera motion trajectories than previously proposed self-supervised methods.

Comment
10 pages, 4 figures, 3 tables. Accepted to MICAD 2026 (International Conference on Medical Imaging and Computer-Aided Diagnosis), Edinburgh, UK, Oct. 22-24, 2026. To appear in Springer Lecture Notes

Closest papers

Nearest neighbours by meaning across the whole index.

Dense Endoluminal Mapping and Localisation from Monocular Bronchoscopy

cs.CV ·2026-10-12 ·Salvatore Esposito, Matias Mattamala, Daniel Rebain, Liang Zhao, Kev Dhaliwal +2 more
similarity 0.75
Abstract

Bronchoscopy inserts a camera through the airways to diagnose endoluminal disease. Locating the camera along the airway usually requires additional equipment, such as an electromagnetic tracker and a preoperative CT scan. In this paper, we investigate the use of the monocular camera stream to localise the bronchoscope without requiring additional sensing. We introduce a monocular SLAM system that localises the tip of a bronchoscope and reconstructs the airway surface around it from RGB video alone. A Depth Anything 3 backbone, fine-tuned on over a million photorealistic airway renderings, returns metric per-pixel depth and is the system's only source of scale. DINOv3 features routed through a custom cross-attention matcher supply sub-pixel correspondences on mucosa where classical descriptors fail. Both enter a factor graph alongside a dense constraint from projective iterative closest point (ICP) registration against the system's own running reconstruction, so surface evidence stabilises the directions the visual factors leave weakly observable. On six airways rendered from patient CT scans, the system reaches 26.1 mm mean absolute trajectory error and 77.5% mean surface F-score. Its mean surface accuracy exceeds that of five recent monocular SLAM and feed-forward baselines. MASt3R-SLAM, which fits a free scale to the ground truth, has a lower mean trajectory error (22.0 mm). ORB-SLAM3 completes only two of the six airways, whereas our system completes all six and also reconstructs two ex vivo specimens.

0.16

SCOPE-4D: Endoscopic 4D Geometry Foundation Models

cs.CV ·2026-10-01 ·Chaoyi Zhou, Zhongpai Gao, Anwesa Choudhuri, Meng Zheng, Benjamin Planche +4 more
code/data similarity 0.70
Abstract · Project page: https://chaoyizh.github.io/SCOPE-4D-page/

Geometric understanding supports endoscopic navigation and robotic assistance, but learning reliable endoscopic geometry faces two challenges: scarce geometric annotations and ambiguity between camera motion and tissue deformation. We present SCOPE-4D, an endoscopic 4D geometry foundation model that jointly predicts camera parameters, dense geometry, and 3D tissue trajectories from monocular RGB video in a single forward pass. Our curation and annotation pipeline constructs SCOPE-5K, a collection of approximately 5,000 clips spanning real and synthetic gastrointestinal endoscopy and laparoscopy. The collection provides rich geometric supervision and includes newly collected phantom and real-colonoscopy evaluation sets. Geometric supervised fine-tuning on SCOPE-5K learns endoscopic priors that improve camera and depth estimation. Common--Residual Motion (CRM) further constrains local deformation relative to common tissue movement. Together with geometric supervision, CRM and trajectory supervision further improve camera and depth estimation over geometric fine-tuning alone while enabling dense 3D tissue tracking. Evaluations on public and newly collected benchmarks demonstrate strong in-domain and out-of-domain geometry, superior 3D tracking, and more stable long-sequence colon reconstruction. A blinded user study further supports the perceived reconstruction quality on real clinical video. Together, these results demonstrate the value of large-scale endoscopic supervision and motion constraints for joint geometry estimation and tissue tracking.

0.21

Surgical Kinematics from Monocular Video with Learned Articulated Motion Constraints

cs.CV cs.RO ·2026-09-23 ·Mehmet Kerem Turkcan, Soham Samal, Zoran Kostic
benchmark similarity 0.69
Abstract

Objective assessment of robotic surgery uses instrument kinematics, which must be reconstructed when only video is available. We introduce a kinematic reconstruction network for estimating instrument position, orientation and jaw angle from monocular video. Our visual representation combines global attention pooling of frozen DINOv3 features with local pooling at instrument landmarks from fine-tuned SAM 3.1 masks. Our shared Transformer encoder and temporal convolutional heads integrate this representation with mask geometry, monocular depth and visual state estimates from arm-specific multilayer regression networks. Our position branch predicts displacement magnitude and direction separately to preserve traveled distance. We fit trajectories to predicted state observations and motion increments by differentiable weighted least squares, expressing quaternion observations relative to cumulative predicted rotations to obtain a quadratic orientation objective. We evaluate reconstruction across 2,802 Open-H episodes. Compared with LiveMAE on the main Open-H benchmark, our method reduces path-length mean absolute error from 0.45 to 0.34\,cm and increases temporal mean average precision for motion segmentation from 44.54\% to 54.44\%.

0.20

XPos3R: Cross-Modal Transformer for Intraoperative 2D/3D Registration

eess.IV ·2026-09-09 ·Shiyan Su, Ruyi Zha, Hongdong Li, Xuelian Cheng, Zongyuan Ge
top venue similarity 0.68
Abstract · Accepted to ECCV 2026

Intraoperative 2D/3D registration, which aligns live X-ray images with preoperative volumes, is essential for image-guided interventions. Previous regression-based methods suffer from limited generalization, thus requiring time-consuming patient-specific retraining. Inspired by recent geometry foundation models such as DUSt3R, we propose XPos3R, a generalizable pose regression method that eliminates preoperative preparation. Unlike existing geometry models designed for homogeneous inputs, XPos3R extends this paradigm to multi-modal inputs, namely 2D X-rays and 3D volumes. Specifically, we introduce an asymmetric encoder-decoder architecture that improves cross-modal feature alignment while maintaining computational efficiency. To scale training under limited medical data, we adopt an anatomy-specific data curation strategy and construct million-scale synthetic datasets. Evaluated on real-world benchmarks, a single pretrained XPos3R surpasses patient-specific methods in both accuracy and robustness. With test-time optimization completed in seconds, it further reduces the 3D error to <4 mm and the reprojection error to <1 mm. The strong generalization, accuracy, and efficiency of XPos3R highlight its clinical potential, while its asymmetric framework may inspire broader cross-modal vision geometry tasks.

0.47

iMED: A Multi-Endoscope Dataset for Surgical 3D Perception

cs.CV cs.RO ·2026-11-03 ·Sierra Bonilla, Fengyi Jiang, Chinedu Nwoye, Jingpei Lu, Kailey Reardon +5 more
top venuebenchmarkcode/data similarity 0.67
Abstract · Published at ECCV 2026. 25 pages, including supplementary material. Code and dataset: https://github.com/surgical-vision/imed

We introduce iMED, the first synchronized multi-endoscope dataset for robot-assisted minimally invasive surgery (RAMIS), designed to address a fundamental limitation in surgical vision benchmarking: the absence of independent held-out viewpoints. Existing surgical datasets capture single-trajectory sequences from a single endoscope, making it impossible to distinguish geometric generalization from photometric interpolation along a narrow forward-facing path. iMED provides 340 sequences ~170K synchronized timepoints with 4 views per timepoint) recorded simultaneously from two independent stereo endoscopes across ex vivo, postmortem, and live surgical settings, spanning 14 specimens with diverse anatomical regions and motion regimes. The dataset includes calibrated camera intrinsics, ArUco-based frame-wise pose estimates with uncertainty quantification, instrument segmentation masks, and rich clinical metadata. Using a train-on-one-endoscope, test-on-another evaluation protocol, we benchmark 23 state-of-the-art methods across rigid and deformable novel view synthesis, pose estimation, feature matching, and monocular depth estimation. Our experiments show that methods relying primarily on photometric supervision degrade substantially under this held-out-endoscope setting, while methods with explicit geometric regularization are more robust across views in our benchmark. Notably, large-scale foundation models transfer surprisingly well to surgical imagery, often outperforming domain-specific models, suggesting pitfalls in current fine-tuning protocols. iMED establishes a new evaluation protocol for geometric generalization in surgical vision.

0.70

Colon3R: Cross-Domain 3D Reconstruction from Monocular Colonoscopic Video

cs.CV cs.RO ·2026-09-21 ·Zhihao Xing, Yingyu Wang, Liang Zhao, Shoudong Huang
code/data similarity 0.67
Abstract

Monocular colonoscopic 3D reconstruction is important for surgical robotic colonoscopy, but remains challenging due to weak texture, specular reflections, limited view overlap, and non-rigid tissue motion. Conventional multi-view 3D reconstruction methods rely on stable correspondences and approximate rigidity, which are often violated in colonoscopy. Existing endoscopic methods often rely on domain-specific supervision, whereas there are not enough in-vivo labeled data available to adapt geometry foundation models to clinical colonoscopy. We present Colon3R, a cross-domain semi-supervised framework built on pretrained VGGT that transfers coupled camera, depth, and pointmap geometry from labeled phantom and simulated data to unlabeled in-vivo colonoscopy without requiring target-domain geometric annotations. Unlike source-only fine-tuning, which learns only from phantom and simulated data, Colon3R directly exploits unlabeled in-vivo video through teacher-derived cross-view supervision. Our proposed hierarchical quasi-rigid reliability selects reliable supervision at the sequence, directed-pair, and pixel levels, while source-preserving adaptation retains the learned coupled geometry during target-domain adaptation. Extensive experiments demonstrate that our method achieves superior overall performance over state-of-the-art approaches in depth, pointmap, and camera pose estimation. Qualitative comparisons on real in-vivo colonoscopy further show substantially more complete and geometrically consistent reconstructions than competing methods under clinical domain shift. The code is publicly available at https://github.com/vglx/Colon3R.

0.29

Anatomy-Aware Prediction of Bronchoscopic Accessibility from 3D CT

cs.CV ·2026-09-29 ·Linkai Peng, Cuiling Sun, Bin Wang, Jamie Rowell, Catherine Gao +8 more
top venuebenchmark similarity 0.67
Abstract · Accepted in MICCAI 2026

Pre-operative planning for bronchoscopy is critical for the diagnosis of lung lesions. Current accessibility assessment relies on subjective manual inspection of CT scans, which is time-consuming and prone to inter-observer variability. In this paper, we formalize bronchoscopy accessibility prediction as a novel supervised learning task and present the first end-to-end framework to address it. We propose an Anatomy-Aware Mixture-of-Experts (MoE) model that integrates specialized modules: a CT Expert for local morphological features, a Lobe Expert for anatomical priors, and a Path Geometry Expert that encodes the sequential constraints of the bronchial tree. To support this task, we curated the first clinical dataset of 438 cases with pre-operative CT scans and documented procedural outcomes. Experimental results demonstrate that our method achieves an AUROC of 0.8052, significantly outperforming both state-of-the-art baselines and experienced human experts. This work establishes a new benchmark for computer-aided interventional planning in pulmonary medicine. Our data and code will be publicly available at https://nubagcilab.github.io/BronchoAccess/.

0.37

MV-dVRK: A Multi-Viewpoint Benchmark for Spatial Surgical Perception

cs.CV cs.RO ·2026-09-02 ·Guido Caccianiga, Sergey Prokudin, Yutong Chen, Bernard Javot, Rachael L'Orsa +7 more
benchmark similarity 0.66
Abstract

Large-scale training and refined optimization techniques have greatly improved sparse multi-view 3D reconstruction. Despite their relevance to surgery, such methods have never before been rigorously evaluated on real endoscopic images. Current clinical telerobots deploy a single stereo camera inside the patient, making multi-viewpoint data extremely rare. This paper presents MV-dVRK, the first ex-vivo surgical dataset to combine multiple exposure-synchronized stereo viewpoints with accurate surface geometry and camera poses. The static subset of the benchmark provides dense SfM reference geometry, validated against an industrial 3D scanner, together with ground-truth camera poses and sparse-view test sets. We use MV-dVRK to systematically compare zero-shot monocular, stereo, multi-stereo, and multi-view 3D reconstruction methods as the number of viewpoints increases. With two endoscopes, multi-stereo reconstruction achieves the highest coverage. With a third viewpoint, optimization-based multi-view methods perform best, covering 67% of ground-truth surface points within a 1 mm tolerance and recovering highly accurate relative camera poses. By contrast, feed-forward foundation models cover only 43% of the ground-truth surface in the same setting. MV-dVRK also includes ten dynamic sequences spanning multiple surgical tasks, with increasing kinematic complexity and tissue deformation, providing a basis for future research in multi-viewpoint surgical perception. The project is available at: https://mv-dvrk.is.mpg.de.